Search NASA⌕ Search

SEARCH · Search NASA

Results for “patterned beam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Long Fission Times of Super-Heavy Compound Nuclei

The blocking technique in single crystals is a direct method to investigate the presence of long fission time components. With a lead beam impinging on a germanium single crystal, we tried to produce compound nuclei (CN) with atomic number Z = 114 at high excitation energy. Blocking patterns for reaction products are reconstructed with position sensitive detectors at 20 deg. relative to the beam direction. The Z and the energies of all products are measured with {delta}E-E telescopes of the 4{pi} INDRA array, so that all reaction channels are unambiguously identified. With this setup, we can reach long fission times (>10{sup -18} s) that can be associated with CN fissions. However, in contrast to previous experiments in which such long fission times could be measured for Z = 120 and 124, no hint of long lifetimes within our sensitivity limit for Z = 114 was observed, which may be due to the neutron deficiency of the formed isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cation stoichiometry optimization of SrTiO{sub 3} (110) thin films with atomic precision in homogeneous molecular beam epitaxy

We study the evolution of surface reconstructions on SrTiO{sub 3} (110) determined by cation concentration ratio and find it detectable by high energy electron diffraction (RHEED) even at high temperature up to 800 deg. C. The evaporation rate of Sr and Ti sources can be calibrated precisely by monitoring RHEED patterns in situ and in real time during the extended homogeneous oxide molecule beam epitaxy growth of SrTiO{sub 3} (110) film. High quality film is obtained with deviation of cation stoichiometry less than 0.5%.

36 MATERIALS SCIENCE↗

Design of free patterns of nanocrystals with ad hoc features via templated dewetting

Design of monodisperse ultra-small nanocrystals (NCs) into large scale patterns with ad hoc features is demonstrated. The process makes use of solid state dewetting of a thin film templated through alloy liquid metal ion source focused ion beam (LMIS-FIB) nanopatterning. The solid state dewetting initiated at the edges of the patterns controllably creates the ordering of NCs with ad hoc placement and periodicity. The NC size is tuned by varying the nominal thickness of the film while their position results from the association of film retraction from the edges of the lay out and Rayleigh-like instability. The use of ultra-high resolution LMIS-FIB enables to produce monocrystalline NCs with size, periodicity, and placement tunable as well. It provides routes for the free design of nanostructures for generic applications in nanoelectronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High energy electron diffraction instrument with tunable camera length

Ultrafast electron diffraction (UED) stands as a powerful technique for real-time observation of structural dynamics at the atomic level. In recent years, the use of MeV electrons from radio frequency guns has been widely adopted to take advantage of the relativistic suppression of the space charge effects that otherwise limit the temporal resolution of the technique. Nevertheless, there is not a clear choice for the optimal energy for a UED instrument. Scaling to beam energies higher than a few MeV does pose significant technical challenges, mainly related to the inherent increase in diffraction camera length associated with the smaller Bragg angles. In this study, we report a solution by using a compact post-sample magnetic optical system to magnify the diffraction pattern from a crystal Au sample illuminated by an 8.2 MeV electron beam. Our method employs, as one of the lenses of the optical system, a triplet of compact, high field gradients (>500 T/m), small-gap (3.5 mm) Halbach permanent magnet quadrupoles. Shifting the relative position of the quadrupoles, we demonstrate tuning the magnification by more than a factor of two, a 6× improvement in camera length, and reciprocal space resolution better than 0.1 Å –1 in agreement with beam transport simulations.

47 OTHER INSTRUMENTATION↗

White-light symmetrization by the interaction of multifilamenting beams

We show experimentally that the interaction of two multifilamenting beams in fused silica with incidence angles up to a few degrees results in an increase in the symmetry of the continuum emission from D{sub 2} to C{sub {infinity}} around the axis of symmetry between the two beams. We observe an intense white disk between the locations of the individual conical emission patterns, reducing the conical emission in each of them. We attribute this behavior to an enhanced self-phase modulation in the interference region between the two beams. This frequency conversion depletes by more than 40% the energy initially available in the photon bath to feed filaments.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of a ceramic filled bio-plastic composite sandwich structure

Design and analysis of a ceramic-filled bio-plastic composite sandwich structure is presented. This proposed high-dielectric structure is used as a substrate for patch antennas. A meandered-strip line-fed fractal-shape patch antenna is designed and fabricated on a copper-laminated sandwich-structured substrate. Measurement results of this antenna show 44% and 20% of bandwidths with maximum gains of 3.45 dBi and 5.87 dBi for the lower and upper bands, respectively. The half-power beam widths of 104° and 78° have been observed from the measured radiation pattern at the two resonance frequencies 0.9 GHz and 2.5 GHz.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Visible photoluminescence and room temperature ferromagnetism in high In-content InGaN:Yb nanorods grown by molecular beam epitaxy

We report the growth of high indium content InGaN:Yb nanorods grown on c-plane sapphire (0001) substrates using plasma assisted molecular beam epitaxy. The in situ reflection high energy electron diffraction patterns recorded during and after the growth revealed crystalline nature of the nanorods. The nanorods were examined using electron microscopy and atomic force microscopy. The photoluminescence studies of the nanorods showed the visible emissions. The In composition was calculated from x-ray diffraction, x-ray photoelectron spectroscopy, and the photoluminescence spectroscopy. The In-concentration was obtained from photoluminescence using modified Vegard's law and found to be around 37% for InGaN and 38% for Yb (5 ± 1%)-doped InGaN with a bowing parameter b = 1.01 eV. The Yb-doped InGaN showed significant enhancement in photoluminescence properties compared to the undoped InGaN. The Yb-doped InGaN nanorods demonstrated the shifting of the photoluminescence band at room temperature, reducing luminescence amplitude temperature dependent fluctuation, and significant narrowing of excitonic emission band as compared to the undoped InGaN. The magnetic properties measured by superconducting quantum interference devices reveals room temperature ferromagnetism, which can be explained by the double exchange mechanism and magnetostriction.

36 MATERIALS SCIENCE↗

Scattering of Gaussian Beams by Disordered Particulate Media

A frequently observed characteristic of electromagnetic scattering by a disordered particulate medium is the absence of pronounced speckles in angular patterns of the scattered light. It is known that such diffuse speckle-free scattering patterns can be caused by averaging over randomly changing particle positions and/or over a finite spectral range. To get further insight into the possible physical causes of the absence of speckles, we use the numerically exact superposition T-matrix solver of the Maxwell equations and analyze the scattering of plane-wave and Gaussian beams by representative multi-sphere groups. We show that phase and amplitude variations across an incident Gaussian beam do not serve to extinguish the pronounced speckle pattern typical of plane-wave illumination of a fixed multi-particle group. Averaging over random particle positions and/or over a finite spectral range is still required to generate the classical diffuse speckle-free regime.

radiative transfer theory↗

An algorithm to calculate a collapsed arc dose matrix in volumetric modulated arc therapy

Purpose: The delivery of volumetric modulated arc therapy (VMAT) is more complex than other conformal radiotherapy techniques. In this work, the authors present the feasibility of performing routine verification of VMAT delivery using a dose matrix measured by a gantry mounted 2D ion chamber array and corresponding dose matrix calculated by an inhouse developed algorithm.Methods: Pinnacle, v9.0, treatment planning system (TPS) was used in this study to generate VMAT plans for a 6 MV photon beam from an Elekta-Synergy linear accelerator. An algorithm was developed and implemented with inhouse computer code to calculate the dose matrix resulting from a VMAT arc in a plane perpendicular to the beam at isocenter. The algorithm was validated using measurement of standard patterns and clinical VMAT plans with a 2D ion chamber array. The clinical VMAT plans were also validated using ArcCHECK measurements. The measured and calculated dose matrices were compared using gamma ({gamma}) analysis with 3%/3 mm criteria and {gamma} tolerance of 1.Results: The dose matrix comparison of standard patterns has shown excellent agreement with the mean {gamma} pass rate 97.7 ({sigma}= 0.4)%. The validation of clinical VMAT plans using the dose matrix predicted by the algorithm and the corresponding measured dose matrices also showed good agreement with the mean {gamma} pass rate of 97.6 ({sigma}= 1.6)%. The validation of clinical VMAT plans using ArcCHECK measurements showed a mean pass rate of 95.6 ({sigma}= 1.8)%.Conclusions: The developed algorithm was shown to accurately predict the dose matrix, in a plane perpendicular to the beam, by considering all possible leaf trajectories in a VMAT delivery. This enables the verification of VMAT delivery using a 2D array detector mounted on a treatment head.

61 RADIATION PROTECTION AND DOSIMETRY↗

Reactivity Coefficient Calculation for a Low-Power LEU Research Reactor

Core design studies on a 20-MW thermal power low enriched uranium (LEU) fueled research reactor are underway at the NIST Center for Neutron Research (NCNR) with the primary purpose of providing quality neutron beams for scientific research. The 'tank-in-pool' design pattern is adopted for the new reactor: A compact core composed of two horizontally split halves are surrounded by a cylindrical D{sub 2}O reflector tank, and the tank is itself surrounded by a large H{sub 2}O pool, which functions as thermal and biological shielding. The split core consists of 18 MTR-type fuel elements which are evenly distributed into two regions. The LEU fuel used in the study is the U{sub 3}Si{sub 2}-Al dispersion fuel with U-235 enrichment of 19.75%, the only NRC certified LEU fuel in the U.S. The core is cooled and moderated by H{sub 2}O, and separated from D{sub 2}O by zircaloy core boxes. Hafnium control blades are utilized as both criticality and safety control elements for the reactor. They are controlled by a mechanical driver located at the bottom of the core but with the fully withdrawn positions at the top of the core. In a standard reactor calculation, it is necessary to evaluate the reactivity coefficient with respect to some physical parameters such as fuel or moderator temperature. For nearly all reactor designs, negative reactivity coefficients are required for safety. As a light-water cooled thermal reactor, the new reactor is designed to work in an under-moderated mode with the most achievable reactivity. The core is required to have negative reactivity coefficients under any normal or abnormal circumstances such as over power transient, loss of coolant or reflector, etc. Therefore the reactivity coefficient addresses reactor safety concerns as well as provides valuable quantitative parameters for reactor safety analyses. In this summary, three typical reactivity coefficients for the low-power LEU core are calculated using the Monte-Carlo code MCNP-6: the moderator temperature coefficient (MTC), the fuel temperature coefficient (FTC), and the void coefficient (VC). A direct perturbation methodology is applied to calculate all these coefficients. The perturbed case is produced by manually perturbing a single physical property with respect to the reference case (the one with normal operational conditions), as the multiplication factor (i.e. k{sub eff}) of the perturbed case is calculated by MCNP. The corresponding reactivity coefficient is thereby determined by dividing the reactivity change over the associated parameter changes. Core design studies are underway at NIST to develop a low-power LEU fueled beam reactor to advance the neutron source capability at NCNR for the next century. The reactivity effect caused by moderator temperature, fuel temperature and void is investigated though a direct perturbation approach using the MCNP code. The MTC, FTC, and VC for a representative startup core is obtained and the negative effect characteristics of these coefficients are observed. The reactivity effects under several postulated abnormal scenarios are also investigated. The overall negative feedback to the reactivity at each situation is confirmed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Multi-beam X-ray ptychography for high-throughput coherent diffraction imaging

X-ray ptychography is a rapidly developing coherent diffraction imaging technique that provides nanoscale resolution on extended field-of-view. However, the requirement of coherence and the scanning mechanism limit the throughput of ptychographic imaging. Herein, we propose X-ray ptychography using multiple illuminations instead of single illumination in conventional ptychography. Multiple locations of the sample are simultaneously imaged by spatially separated X-ray beams, therefore, the obtained field-of-view in one scan can be enlarged by a factor equal to the number of illuminations. We have demonstrated this technique experimentally using two X-ray beams focused by a house-made Fresnel zone plate array. Two areas of the object and corresponding double illuminations were successfully reconstructed from diffraction patterns acquired in one scan, with image quality similar with those obtained by conventional single-beam ptychography in sequence. Multi-beam ptychography approach increases the imaging speed, providing an efficient way for high-resolution imaging of large extended specimens.

47 OTHER INSTRUMENTATION↗

Hohlraum Target Alignment from X-ray Detector Images using Starburst Design Patterns

National Ignition Facility (NIF) is a high-energy laser facility comprised of 192 laser beams focused with enough power and precision on a hydrogen-filled spherical, cryogenic target to initiate a fusion reaction. The target container, or hohlraum, must be accurately aligned to an x-ray imaging system to allow careful monitoring of the frozen fuel layer in the target. To achieve alignment, x-ray images are acquired through starburst-shaped windows cut into opposite sides of the hohlraum. When the hohlraum is in alignment, the starburst pattern pairs match nearly exactly and allow a clear view of the ice layer formation on the edge of the target capsule. During the alignment process, x-ray image analysis is applied to determine the direction and magnitude of adjustment required. X-ray detector and source are moved in concert during the alignment process. The automated pointing alignment system described here is both accurate and efficient. In this paper, we describe the control and associated image processing that enables automation of the starburst pointing alignment.

42 ENGINEERING↗

Nanofabrication on unconventional substrates using transferred hard masks

Here, a major challenge in nanofabrication is to pattern unconventional substrates that cannot be processed for a variety of reasons, such as incompatibility with spin coating, electron beam lithography, optical lithography, or wet chemical steps. Here, we present a versatile nanofabrication method based on re-usable silicon membrane hard masks, patterned using standard lithography and mature silicon processing technology. These masks, transferred precisely onto targeted regions, can be in the millimetre scale. They allow for fabrication on a wide range of substrates, including rough, soft, and non-conductive materials, enabling feature linewidths down to 10 nm. Plasma etching, lift-off, and ion implantation are realized without the need for scanning electron/ion beam processing, UV exposure, or wet etching on target substrates.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Imaging single cells in a beam of live cyanobacteria with an X-ray laser (CXIDB ID 27)

Diffraction pattern of a micron-sized S. elongatus cell at 1,100 eV photon energy (1.13 nm wavelength) with ~10^11 photons per square micron on the sample in ~70 fs. The signal to noise ratio at 4 nm resolution is 3.7 with 0.24 photons per Nyquist pixel. The cell was alive at the time of the exposure. The central region of the pattern (dark red) is saturated and this prevented reliable image reconstruction.

AMO↗

Assessing the manufacturing tolerances and uniformity of CMOS compatible metamaterial fabrication

The manufacturing tolerances of a stencil-lithography variant, membrane projection lithography, were investigated. In the first part of this work, electron beam lithography was used to create stencils with a range of linewidths. These patterns were transferred into the stencil membrane and used to pattern metallic lines on vertical silicon faces. Only the largest lines, with a nominal width of 84 nm, were resolved, resulting in 45 ± 10 nm (average ± standard deviation) as deposited with 135-nm spacing. Although written in the e-beam write software file as 84-nm in width, the lines exhibited linewidth bias. This can largely be attributed to nonvertical sidewalls inherent to dry etching techniques that cause proportionally larger impact with decreasing feature size. The line edge roughness can be significantly attributed to the grain structure of the aluminum nitride stencil membrane. In the second part of this work, the spatial uniformity of optically defined (as opposed to e-beam written) metamaterial structures over large areas was assessed. A Fourier transform infrared spectrometer microscope was used to collect the reflection spectra of samples with optically defined vertical split ring from 25 spatially resolved 300 × 300 μm regions in a 1-cm2 area. The technique is shown to provide a qualitative measure of the uniformity of the inclusions.

36 MATERIALS SCIENCE↗

Investigation on Vibration Response of Aluminum Foam Beams Using Speckle Interferometry

This paper firstly presents a brief review on the representations of speckle fringe pattern in vibration measurement using time-averaged electronic speckle pattern interference (ESPI) method. Based on laser phase noise, a new representation of speckle fringe intensity generated by real-time subtraction ESPI method for vibrating measurement is then proposed. In the experimental performance, the real-time subtraction ESPI method is employed to inspect the vibrating response of a closed-cell aluminum foam cantilever beam. In contract with the results of the finite elemental method simulation, the vibration mode shapes obtained by the ESPI method are well agreed with numerical prediction. The optical vibration analysis is also carried out to determine the effective Young’s modulus of aluminum foam, and the results verify the validation of the ESPI method for investigation on mechanical properties of metal foam materials.

36 MATERIALS SCIENCE↗

Characterization of Charging Control of a Single Wafer High Current Spot Beam Implanter

This paper focuses on the characterization of charging control of an Axcelis Optima HD single wafer high current spot beam implanter using MOS capacitors with attached antennas of different size and shape. Resist patterns are implemented on Infineon Technologies own charging control wafers to investigate the influence of photo resist on charging damage. Compared to batch high current implanters the design of the beamline and the beam shape are comparable to single wafer high current spot beam implanters, however due to the different scanning architecture the dose rate of the single wafer high current spot beam implanters is significantly higher compared to the batch tools. Therefore, the risk of charging damage will be higher. The charging damage was studied as a function of the energy, the beam current and the most important plasma flood gun parameters. The results have shown that for very high antenna ratios the charging damage for single wafer implanters, even spot or ribbon beam implanters, is higher than for high current batch implanters.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Three-dimensional Bragg coherent diffraction imaging of an extended ZnO crystal

A complex three-dimensional quantitative image of an extended zinc oxide (ZnO) crystal has been obtained using Bragg coherent diffraction imaging integrated with ptychography. By scanning a 2.5 µm-long arm of a ZnO tetrapod across a 1.3 µm X-ray beam with fine step sizes while measuring a three-dimensional diffraction pattern at each scan spot, the three-dimensional electron density and projected displacement field of the entire crystal were recovered. The simultaneously reconstructed complex wavefront of the illumination combined with its coherence properties determined by a partial coherence analysis implemented in the reconstruction process provide a comprehensive characterization of the incident X-ray beam.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗