Search NASA⌕ Search

SEARCH · Search NASA

Results for “reliability data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Achieving Lights-Out Operation of SMAP Using Ground Data System Automation

The approach used in the SMAP ground data system to provide reliable, automated capabilities to conduct unattended operations has been presented. The impacts of automation on the ground data system architecture were discussed, including the three major automation patterns identified for SMAP and how these patterns address the operations use cases. The architecture and approaches used by SMAP will set the baseline for future JPL Earth Science missions.

Soil Moisture Active Passive (SMAP)↗

Measuring the effects of distributed database models on transaction availability measures

Data distribution, data replication, and system reliability are key factors in determining the availability measures for transactions in distributed database systems. In order to simplify the evaluation of these measures, database designers and researchers tend to make unrealistic assumptions about these factors. Here, the effect of such assumptions on the computational complexity and accuracy of such evaluations is investigated. A database system is represented with five parameters related to the above factors. Probabilistic analysis is employed to evaluate the availability of read-one and read-write transactions. Both the read-one/write-all and the majority-read/majority-write replication control policies are considered. It is concluded that transaction availability is more sensitive to variations in degrees of replication, less sensitive to data distribution, and insensitive to reliability variations in a heterogeneous system. The computational complexity of the evaluations is found to be mainly determined by the chosen distributed database model, while the accuracy of the results are not so much dependent on the models.

Mukkamala, Ravi↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Results of software error-data experiments

In order to evaluate existing software reliability models and proposed modeling approaches, a search was conducted for data on the software failure process. This search revealed that the data necessary for this evaluation were not available. As a result, a research effort was initiated by NASA to generate data on which to base the development of credible methods for assessing the reliability of software targeted for flight-crucial applications. Two sets of software error-data experiments were conducted by different research groups. The results of the experiments were consistent: errors caused by different faults in a program occurred at widely varying rates; program failure rates exhibited a log-linear trend with respect to the number of faults corrected; some faults were found to interact in either concealing or revealing ways; and contiguous regions of the input space which cause a program to generate errors, called error crystals, were found and characterized for some faults. Collectively, these experiments have produced information on software failure which must be accounted for in software reliability modeling approaches.

Finelli, George B.↗

Fracture Toughness Evaluation for Spent Nuclear Fuel Clad Systems Using Spiral Notch Torsion Fracture Toughness Test

Many radioactive materials within the nuclear fuel cycle present a significant hazard. Such materials include spent nuclear fuel, high-level waste, legacy waste and other nuclear materials. These materials are often held in long-term storage as an interim stage within their lifecycle, including reuse or disposal. Safety and security of spent nuclear fuel (SNF) interim storage installations and follow-on SNF transportations to its final repository sites are very important, due to a great concentration of fission products, actinides and activation products. Fracture mechanics approach in applying to SNF system reliability investigation, especially for the high burn up (HBU) SNF, during SNF long term dry storage or SNF transportation is necessary due to the inherited flaws and inhomogeneity structures existed in a SNF system from the reactor operation. For instance, such as hydride and oxide formation, surface flaw induced by SNF assembly contact interactions, or internal flaws induced by pellet-clad mechanical interaction (PCMI). However, none of the existing fracture toughness data deal with fuel cladding specific geometry or SNF material conditions, such as cladding structure with the segment fuel pellets configuration and the PCMI mechanism. Consequently, the application of existing fracture toughness data to SNF system reliability investigation can be error prone; thus, the development of an industry-wide consensus fracture mechanics approach is needed. The objective of this research is to develop an in-situ fracture mechanics testing protocol, including the associated analytical procedure, that is suitable for evaluating the SNF fracture toughness. Fracture toughness data was obtained under quasi-static fracture loading using Oak Ridge National Laboratory (ORNL) developed Spiral Notch Torsion Test (SNTT) technology carried out on a biaxial tension/torsion tester. These data will be used to support SNF reliability investigation during long-tern SNF dry storage stage or in the follow-on SNF system transport to the final repository sites. SNTT has been a recent breakthrough in measuring fracture toughness for different materials, including metals, ceramics, concrete and polymers composites. Due to its high geometry constraint and unique loading condition, SNTT can be used to measure the fracture toughness with smaller specimens without concern of size effects. The application of SNTT to brittle materials has been proved to be successful. The micro-cracks induced by original notches in brittle materials could ensure crack growth in SNTT samples. Therefore, no fatigue pre cracks are needed for brittle materials specimens. The application of SNTT to the ductile material to generate valid toughness data will require a test sample with sufficient pre-crack length to increase the sample localized constraint at crack front. Fatigue pre-crack growth techniques with the associated compliance function estimated was developed for estimating the crack penetration depth to monitor the fatigue crack growth evolution. In order to extend SNTT approach to a thin shell cladding structure material, a new testing protocol and the associated analytical procedure for estimating the SNF fracture toughness was developed. The detailed SNTT approach and its estimated fracture toughness for the Zr-4 cladding structure with segment alumina inserts are presented in this report. The SNTT test results indicate that SNTT method is a reliable test approach with good repeatability in applying to Zr-4 cladding material. For the medium and the short crack length, the estimate J Q upon fracture for the baseline Zr-4 cladding is at 285.7 lb/in with 2-sigma uncertainty of 18.59 lb/in., and the associated K Q is at 61.4 Ksi√in. For a long crack length, the crack initialization orientation is apparently deviated from the principle tensile stress contour – 45° spiral crack front (i.e., Mode I + Mode III failure mechanism); and the estimated J Q is at 108 lb/in., the associated K Q is at 37.7 Ksi√in. The estimate Mode I J Q (along the 45° pitch principle tensile stress contour) is at 200 lb/in.; which indicate a significant reduction in the fracture toughness in a tubing structure under mixed mode loading condition, Mode I + Mode III, compared to that of Mode I (tensile stress dominated) alone.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Laboratory evaluation of open source and commercial electrical conductivity sensor precision and accuracy: How do they compare?

Variation in the electrical conductivity (EC) of water can reveal environmental disturbance and natural dynamics, including factors such as anthropogenic salinization. Broader application of open source (OS) EC sensors could provide an inexpensive method to measure water quality. While studies show that other water quality parameters can be robustly measured with sensors, a similar effort is needed to evaluate the performance of OS EC sensors. To address this need, we evaluated the accuracy (mean error, %) and precision (sample standard deviation) of OS EC sensors in the laboratory via comparison to EC calibration standards using three different OS and OS/commercial-hybrid (OS/C) EC sensors and data logger configurations and two commercial (C) EC sensors and data logger configurations. We also evaluated the effect of cable length (7.5 m and 30 m) and sensor calibration on OS sensor accuracy and precision. We found a significant difference between OS sensor mean accuracy (3.08%) and all other sensors combined (9.23%). Our study also found that EC sensor precision decreased across all sensor configurations with increasing calibration standard EC. There was also a significant difference between OS sensor mean precision (2.85 μS/cm) and the mean precision of all other sensors combined (9.12 μS/cm). Cable length did not affect OS sensor precision. Furthermore, our results suggest that future research should include evaluating how performance is impacted by combining OS sensors with commercial data loggers as this study found significantly decreased performance in OS/commercial-hybrid sensor configurations. To increase confidence in the reliability of OS sensor data, more studies such as ours are needed to further quantify OS sensor performance in terms of accuracy and precision across different settings and OS sensor and data collection platform configurations.

54 ENVIRONMENTAL SCIENCES↗

Thermodynamics of Silicon-Hydroxide Formation in H2O Containing Atmospheres

The formation of volatile silicon-hydroxide species from SiO2 in water containing atmospheres has been identified as a potentially important mode of degradation of Si-based ceramics. Availability of thermodynamic data for these species is a major problem. This study is part of an ongoing effort to obtain reliable, experimentally determined thermodynamic data for these species. The transpiration method was used to measure the pressure of Si-containing vapor in equilibrium with SiO2 (cristobalite) and Ar + H2O(g) with various mole fractions of water vapor, X(sub H2O), at temperatures ranging from 1000 to 1780 K. Enthalpies and entropies for the reaction, SiO2(s) + 2H2O(g) = Si(OH)4(g), were obtained, at X(sub H2O) = 0.15 and 0.37, from the variation of lnK with 1/T according to the 'second law method'. The following data were obtained: delta(H)deg = 52.9 +/- 3.7 kJ/mole and delta(S)deg = -68.6 +/- 2.5 J/mole K at an average temperature of 1550 K, and delta(H)deg = 52.5+/-2.0 kJ/mole and delta(S)deg= -69.7 +/- 1.5 J/moleK at an average temperature of 1384 K, for X(sub H2O)= 0.15 and 0.37, respectively. These data agree with results from the literature obtained at an average temperature of 1600 K, and strongly suggest Si(OH)4(g) is the dominant vapor species. Contradictory results were obtained with the determination of the dependence of Si-containing vapor pressure on the partial pressure of water vapor at 1187 and 1722 K. These results suggested the Si-containing vapor could be a mixture of Si(OH)4 + SiO(OH)2. Further pressure dependent studies are in progress to resolve these issues.

Copland, Evan↗

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

data retention↗

An Evaluation of Flash Cells Used in Critical Applications

Due to the common use of Flash technology in many commercial and industrial Programmable Logic Devices (PLDs) such as FPGAs and mixed-signal microcontrollers, flash technology is being utilized in fuzed munition applications. This presents a long-term reliability issue for both DoD and NASA safety- and mission-critical applications. A thorough understanding of the data retention failure modes and statistics associated with Flash data retention is of vital concern to the fuze safety community. A key retention parameter for a flash cell is the threshold voltage (VTH), which is an indirect indicator of the amount of charge stored on the cells floating gate. Initial test results based on a study of charge loss in flash cells in an FPGA device is presented. Statistical data taken from a small sample set indicates quantifiable charge loss for devices stored at both room temperature and 150 C. Initial evaluation of the distribution of threshold voltage in a large sample set (800 devices) is presented. The magnitude of charge loss from exposure to electrostatic discharge and electromagnetic fields is measured and presented. Simulated data (and measured data as available) resultant from harsh-environment testing (neutron, heavy ion, EMP) is presented.

Data Retention↗

Database Design Strategies for Coordinated Simulation and Testing in Additive Manufacturing

The qualification and certification (Q&C) process presents a significant challenge for widespread adoption of additive manufacturing (AM) materials and processes for aerospace applications. A relational database framework will be presented as a tool for data curation of coordinated experimental and computational materials modeling research activities. A comparison of relational and hierarchical data structures in this domain will be emphasized through the evolution of a database design strategy. This framework’s mission is to support the advancement of computational materials-informed Q&C by providing the necessary data infrastructure to trace reliability and reproducibility measures through unified AM materials simulation and experimental testing. FAIR (findable, accessible, interoperable, and reusable) data will be highlighted as a necessary precursor for automation of specific actions, which ultimately reduces the time and expense burden for Q&C. The discussion will be mostly limited to back-end design elements, though a few front-end user experience examples will also be shared.

Qualification↗

The automated strength-aeroelastic design of aerospace structures program

An ongoing program whose goal is to develop an automated procedure that can assist in the preliminary design of aircraft and space structures is described. The approach and capabilities that are to be included in the final procedures are descussed. By using proven engineering software as a basis for the project, a reliable and interdisciplinary procedure is developed. The use of a control language for module sequencing and execution permits efficient development of the procedure and gives the user significant flexibility in altering or enhancing the procedure. The data base system provides reliable and efficient access to the large amounts of interrelated data required in an enterprise of this sort. In addition, the data base allows interfacing with existing pre- and post-processors in an almost trivial manner. Altogether, the procedure promises to be of considerable utility to preliminary structural design teams.

Johnson, E. H.↗

"PoliMOR: A Policy Engine \"Made-to-Order\" for Automated and Scalable Data Management in Lustre"

Modern supercomputing systems are increasingly reliant on hierarchical, multi-tiered file and storage system architectures due to cost-performance-capacity trade-offs. Within such multi-tiered systems, data management services are required to maintain healthy utilization, performance, and capacity levels. We present PoliMOR, a pragmatic and reliable policy-driven data management framework. PoliMOR is composed of modular, single-purpose agents that gather file system metadata and enforce policies on storage systems. PoliMOR facilitates automated and scalable data management with customizable agents tailored to HPC facility-specific storage systems and policies. Our evaluations demonstrate the scalability and performance of PoliMOR both by its individual agents and as a collective entity. We believe PoliMOR is widely applicable across HPC facilities with large-scale data management challenges and will garner interest from the HPC community, given its flexible and open-source nature.

George, Anjus↗

Medical Signal-Conditioning and Data-Interface System

A general-purpose portable, wearable electronic signal-conditioning and data-interface system is being developed for medical applications. The system can acquire multiple physiological signals (e.g., electrocardiographic, electroencephalographic, and electromyographic signals) from sensors on the wearer s body, digitize those signals that are received in analog form, preprocess the resulting data, and transmit the data to one or more remote location(s) via a radiocommunication link and/or the Internet. The system includes a computer running data-object-oriented software that can be programmed to configure the system to accept almost any analog or digital input signals from medical devices. The computing hardware and software implement a general-purpose data-routing-and-encapsulation architecture that supports tagging of input data and routing the data in a standardized way through the Internet and other modern packet-switching networks to one or more computer(s) for review by physicians. The architecture supports multiple-site buffering of data for redundancy and reliability, and supports both real-time and slower-than-real-time collection, routing, and viewing of signal data. Routing and viewing stations support insertion of automated analysis routines to aid in encoding, analysis, viewing, and diagnosis.

Braun, Jeffrey↗

Triboelectric Nanogenerator Repeatability and Reproducibility Study

The development of triboelectric nanogenerators (TENGs) has largely focused on optimizing output performance, often at the expense of other critical research considerations such as the development of reliable technical procedures. In particular, the reliability of reported results—specifically repeatability and reproducibility—remains underexplored and is frequently limited to brief discussion within available literature. Without rigorous validation through repeatability and reproducibility studies, the credibility and broader applicability of reported findings remain uncertain. This study addresses this gap by systematically evaluating the repeatability and reproducibility of TENG performance data. Five polymer materials—Kapton, polyethylene (PE), polyethylene terephthalate (PET), polytetrafluoroethylene (PTFE), and polyvinylidene fluoride (PVDF)—were investigated across all pairwise combinations of 25 total combinations for the reproducibility study and three selected pairs of the 25 samples were selected for the repeatability study. For each TENG pairing, we analyzed the methodology, experimental procedures, and resulting performance data to quantify consistency and reliability. The objective of this work is to assess the validity of the collected dataset and determine whether the observed performance trends are consistent for use in future TENG design and optimization studies. Establishing reliable and reproducible data is essential for advancing the development of high-output TENG systems and ensuring their dependable implementation in practical applications.

36 MATERIALS SCIENCE↗

Poisson vs. Gaussian statistics for sparse X-ray data: Application to the soft X-ray spectrometer

Reliable results when fitting X-ray data require proper consideration of the statistics involved. We probe the impact of Gaussian versus Poisson statistics at low count levels using both the standard χ^(2) method and maximum likelihood based on Poisson (C) statistics. The difference is studied and quantified through simulated spectra with known properties. We then test the results through analysis of Mn Kα calibration data taken with the flight spare microcalorimeter for the Hitomi soft X-ray spectrometer. Through comparison with simulations, our results show that the χ^(2) method tends to give overly optimistic estimates of the detector energy resolution, in particular when there are few counts. Given an energy resolution of ∼5 eV and a line with about 100 photons, the line width becomes ∼10% lower in the χ^(2) method than in Poisson statistics. This is a consequence of the uncertainties being dominated by counting statistics, and therefore highlights the need to choose the appropriate fit statistic.

Shinya Yamada↗

Comparison of Daytime Low-Level Cloud Properties Derived From GOES and ARM SGP Measurements

Large-scale satellite data are critical for both verifying and improving general circulation model parameterizations of clouds and radiation for climate prediction. For reliable application of satellite data sets in cloud processes and climate models, it is important to have a reasonable estimate of the errors in the derived cloud properties. The daytime single-layered low-level cloud properties retrieved by the Geostationary Operational Environmental Satellite system (GOES) are compared with ground-based observations and retrievals over the Department of Energy Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Central Facility from June 1998 to December 2006. The GOES retrievals are made via the Visible-Infrared Solar-infrared Split-window Technique. They are spatially averaged within a 0.15° × 0.15° box centered on the ARM SGP site, and the ARM surface observations are temporally averaged ±15 min around the GOES scans to produce collocated pairs. Comparisons are made for monthly means, diurnal means, and one-to-one GOES and ARM collocated pairs. GOES T eff is highly correlated with ARM T top cloud temperature, having an R 2 value of 0.75, though GOES exhibits a cold bias. GOES-retrieved τ and liquid water path have very good agreement with ARM retrievals with R 2 s of 0.45 and 0.47, while r e (GOES), on average, is about 2 μm greater than ARM r e . An examination of solar and viewing geometry has shown that GOES-retrieved mean r e and τ values are impacted by solar zenith angle and especially scattering angle, which is not unexpected and needs to be accounted for by users.

54 ENVIRONMENTAL SCIENCES↗

Transmission Data-Driven User-Defined Model for Inverter-based and Conventional Power Plants

Recent events in Odessa [1], [2] have shed light on the complexities of integrating large Inverter-Based Resource (IBR) plants with the transmission system, prompting NERC to stress continuous performance monitoring by transmission operators. Challenges such as plant control updates, IBR model revisions, Phase-locked loop loss of synchronism, and protection events have been identified, underscoring the need for enhanced monitoring protocols by regulatory bodies. The recent FERC 901 order underscores the importance of accurate data exchange regarding IBRs for reliability studies. However, limited access to IBR plant-related data hampers effective decision-making for transmission operators (TOP). This paper proposes a method for constructing data-driven User-Defined dynamic Models (UDM) for power plants for validating multiple-event data using field measurements from interconnection bus locations. The problem is formulated as a power plant model identification problem and a multi-task learning approach under partial input observability assumptions is proposed in this work. This approach aims to predict aggregated responses of conventional and IBR power plants during various dynamic physical events which is useful for planning studies under diverse disturbance conditions. Ultimately, this methodology emphasizes the importance of plant visibility to operators in addressing power system challenges, facilitating improved planning and operational studies.

Mahapatra, Kaveri [BATTELLE (PACIFIC NW LAB)]↗

A Demonstration that Correcting for Completeness and Reliability Is Critical for Robust Occurrence Rates

A measurement of planetary occurrence rates based on a planet catalog should be robust against details of how initial detections were classified as planets or false positives. This is accomplished by supplying the catalog’s rate of missed planets (completeness) and rate of non-planets incorrectly called planets (reliability). The final Kepler data release (DR25) includes products that can be used with the DR25 planet candidate catalog to correct for completeness and reliability in occurrence rate estimates. This is made possible by the Kepler Robovetter, which algorithmically and uniformly selects planets based on a variety of metrics and thresholds. Completeness, reliability, and occurrence rates potentially depend on these Robovetter thresholds. We study the impact of varying these vetting thresholds using the techniques of Bryson et al. 2019 (arXiv:1906.03575). We explore sets of thresholds that result in more or fewer planets (trading off completeness for reliability), as well as thresholds tuned to pass DR25 false positives identified as possible planets by the Kepler False Positive Working Group. We find that when correcting only for completeness, and not reliability, the resulting occurrence rates have a strong dependence on these threshold sets. For example, the value of SAG13 eta-Earth varies by over a factor of 4 when not corrected for reliability. However, when correcting for both completeness and reliability, occurrence rates using our threshold sets are statistically indistinguishable, with differences being well inside 1-sigma error bars. We present occurrence rates integrated over several period-radius ranges. For example, SAG13 eta-Earth is consistent with 0.127 (+0.094)(-0.054) (from Bryson et al. 2019) for all the Robovetter threshold sets. This result emphasizes the importance of correcting occurrence rates for both completeness and reliability. This suggests that inconsistent completeness and reliability correction may be a significant contributor to the large variation of occurrence rates in recent literature. We plan to make the Robovetter results for our threshold sets available, and encourage the community to use them to examine whether other occurrence rate methods yield similarly robust results.

Bryson, S.↗