Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample minimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

A Multi-Chamber System for Analyzing the Outgassing, Deposition,and Associated Optical Degradation Properties of Materials in a Vacuum

We report on the Camera Materials Test Chamber, a multi-vessel apparatus which analyzes the outgassing consequences of candidate materials for use in the vacuum cryostat of a new telescope camera. The system measures the outgassing products and rates of samples of materials at different temperatures, and collects films of outgassing products to measure the effects on light transmission in six optical bands. The design of the apparatus minimizes potential measurement errors introduced by background contamination.

47 OTHER INSTRUMENTATION↗

Constraint energy minimizing generalized multiscale finite element method for multi-continuum Richards equations

In fluid flow simulation, the multi-continuum model is a useful strategy. When the heterogeneity and contrast of coefficients are high, the system becomes multiscale, and some kinds of reduced order methods are demanded. Combining these techniques with nonlinearity, we will consider in this paper a dual-continuum model which is generalized as a multi-continuum model for a coupled system of nonlinear Richards equations as unsaturated flows, in complex heterogeneous fractured porous media; and we will solve it by a novel multiscale approach utilizing the constraint energy minimizing generalized multiscale finite element method (CEM-GMsFEM). In particular, such a nonlinear system will be discretized in time and then linearized by Picard iteration (whose global convergence is proved theoretically). Subsequently, we tackle the resulting linearized equations by the CEM-GMsFEM and obtain proper offline multiscale basis functions to span the multiscale space (which contains the pressure solution). More specifically, we first introduce two new sources of samples, and the GMsFEM is used over each coarse block to build local auxiliary multiscale basis functions via solving local spectral problems, that are crucial for detecting high-contrast channels. Second, per oversampled coarse region, local multiscale basis functions are created through the CEM as constrainedly minimizing an energy functional. Various numerical tests for our approach reveal that the error converges with the coarse-grid size and that only few oversampling layers as well as basis functions are needed.

97 MATHEMATICS AND COMPUTING↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Elucidating and contrasting the mechanisms for Mg and Ca sulfate ion-pair formation with multi-level embedded quantum mechanics/molecular dynamics simulations

Here, solutions and minerals containing sulfate (SO 4 2- ), and Ca 2+ and Mg 2+ cations, are ubiquitous throughout the lithosphere and are significant components of seawater, thus presenting a prototypical system for the study of strong electrolytes and crystal nucleation mechanisms. However, despite their relative abundance, key questions remain unanswered about the most fundamental atomic-level steps of their mineralization pathways and aqueous dynamics. Here, we carry out enhanced sampling multi-level molecular dynamics (MD) embedded correlated wavefunction theory simulations to elucidate ion-pairing mechanisms for Mg–SO 4 and Ca–SO 4 in concentrated aqueous solution, accurately capturing effects arising from both structural dynamics and electron exchange–correlation. We predict contact-ion-pair formation to be barrierless and highly exoergic for Ca–SO 4 , in agreement with its minimal solubility, whereas for Mg–SO 4 , solvent-shared and contact ion pairs have similar free energies, qualitatively consistent with its higher solubility. Finally, we demonstrate that brief high-temperature pre-equilibration may be utilized to accelerate convergence of free energies in blue-moon-ensemble enhanced-sampling MD.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Samoa Updater: An Application of the Levenberg-Marquardt Method to Update DELFIC Predictions Using Field Measurements

The US Department of Energy (DOE) Forensics Operations (DFO) is a member of the Ground Collections Task Force (GCTF), which is responsible for sample collection of radiological debris for attribution should a nuclear detonation ever occur in the United States. The DFO runs the Defense Land Fallout Interpretive Code (DELFIC) Fallout Planning Tool to predict the deposition of fallout from a nuclear detonation. This prediction is refined using the DELFIC Updater tool, which takes ground measurements and adjusts DELFIC inputs to minimize the difference between prediction and observation, yielding improved predictions of fallout in locations both measured and not yet measured. Samoa, a framework for uncertainty analysis and optimization, is used to improve DELFIC predictive fallout modeling. This new capability using Samoa, dubbed “Samoa Updater,” is compared with the current DELFIC Updater, a brute-force sampling approach. Samoa Updater uses the Levenberg– Marquardt (LM) method, a gradient-based nonlinear least squares approach that uses the functional shape of the input space to increase optimization speed. In simulated test cases Samoa Updater yields faster and more accurate solutions than the current Updater.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

A New Method for Polishing Laminated Dissimilar Metals

Here, this paper presents a novel method for preparing metallographic samples of laminated dissimilar metals, specifically a layered structure of zirconium (Zr), vanadium (V), and tungsten (W), which pose a challenge due to their differing crystal structures and hardness levels. The work was motivated by the need to develop a cladding for tungsten targets in spallation neutron sources, where a zirconium face is applied over an interlayer of either vanadium or titanium to prevent the formation of brittle intermetallic compounds such as ZrW 2 . Traditional polishing techniques prove inadequate because each constituent metal requires a different polishing approach based on its unique material properties. The methodology outlined includes a sequential process involving conductive epoxy mounting, successive grinding and polishing with specific abrasives, and a final chemical-mechanical polish using a colloidal silica-based solution. Optical microscopy confirmed that this multi-step process successfully produced scratch-free surfaces and minimized surface relief across the different metal interfaces. Although developed for refractory metals, this approach shows promise for other layered structures comprised of transition metals, offering a meticulous yet effective technique for high-quality metallographic sample preparation.

Newberry, Daniel [Oak Ridge National Laboratory (O↗

Clustering of LRGs in the DECaLS DR8 Footprint: Distance Constraints from Baryon Acoustic Oscillations Using Photometric Redshifts

A photometric redshift sample of luminous red galaxies (LRGs) obtained from the DECam Legacy Survey (DECaLS) is analyzed to probe cosmic distances by exploiting the wedge approach of the two-point correlation function. Although the cosmological information is highly contaminated by the uncertainties existing in the photometric redshifts from the galaxy map, an angular diameter distance can be probed at the perpendicular configuration in which the measured correlation function is minimally contaminated. An ensemble of wedged correlation functions selected up to a given threshold based on having the least contamination was studied in previous work (Sridhar & Song 2019) using simulations, and the extracted cosmological information was unbiased within this threshold. Furthermore, we apply the same methodology for analyzing the LRG sample from DECaLS, which will provide the optical imaging for targeting two-thirds of the Dark Energy Spectroscopic Instrument footprint and measure the angular diameter distances at z = 0.69 and z = 0.87 to be D A (0.697) = (1529 ± 73 Mpe)(r d /r d.fid ) and D A (0.874) = (1674 ± 102 Mpe)(r d /r d.fid ) with a fractional error of 4.77% and 6.09%, respectively. We obtain a value of H 0 = 66.58 ± 5.31 km s -1 Mpc -1 , which supports the H 0 measured by all other baryon acoustic oscillation results and is consistent with the ΛCDM model.

79 ASTRONOMY AND ASTROPHYSICS↗

Use of ruthenium dyes for subnanosecond detector fidelity testing in real time transient absorption

Transient absorption spectroscopy is a powerful tool for the study of photoreactions on time scales from femtoseconds to seconds. Typically, reactions slower than {approx}1 ns are recorded by the ''classical'' technique; the reaction is triggered by an excitation flash, and absorption changes accompanying the reaction are recorded in real time using a continuous monitoring light beam and a detection system with sufficiently fast response. The pico- and femtosecond region can be accessed by the more recent ''pump-probe'' technique, which circumvents the difficulties of real time detection on a subnanosecond time scale. This is paid for by accumulation of an excessively large number of shots to sample the reaction kinetics. Hence, it is of interest to extend the classical real time technique as far as possible to the subnanosecond range. In order to identify and minimize detection artifacts common on a subnanosecond scale, like overshoot, ringing, and signal reflections, rigorous testing is required of how the detection system responds to fast changes of the monitoring light intensity. Here, we introduce a novel method to create standard signals for detector fidelity testing on a time scale from a few picoseconds to tens of nanoseconds. The signals result from polarized measurements of absorption changes upon excitation of ruthenium complexes {l_brace}[Ru(bpy){sub 3}]{sup 2+} and a less symmetric derivative{r_brace} by a short laser flash. Two types of signals can be created depending on the polarization of the monitoring light with respect to that of the excitation flash: a fast steplike bleaching at magic angle and a monoexponentially decaying bleaching for parallel polarizations. The lifetime of the decay can be easily varied via temperature and viscosity of the solvent. The method is applied to test the performance of a newly developed real time transient absorption setup with 300 ps time resolution and high sensitivity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Volumetric apparatus for hydrogen adsorption and diffusion measurements: Sources of systematic error and impact of their experimental resolutions

The development of a volumetric apparatus (also known as a Sieverts’ apparatus) for accurate and reliable hydrogen adsorption measurement is shown. The instrument minimizes the sources of systematic errors which are mainly due to inner volume calibration, stability and uniformity of the temperatures, precise evaluation of the skeletal volume of the measured samples, and thermodynamical properties of the gas species. A series of hardware and software solutions were designed and introduced in the apparatus, which we will indicate as f-PcT, in order to deal with these aspects. The results are represented in terms of an accurate evaluation of the equilibrium and dynamical characteristics of the molecular hydrogen adsorption on two well-known porous media. The contribution of each experimental solution to the error propagation of the adsorbed moles is assessed. The developed volumetric apparatus for gas storage capacity measurements allows an accurate evaluation over a 4 order-of-magnitude pressure range (from 1 kPa to 8 MPa) and in temperatures ranging between 77 K and 470 K. The acquired results are in good agreement with the values reported in the literature.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On-axis microscopes for the inelastic x-ray scattering beamline at NSLS-II

A novel on-axis X-ray microscope with 3 µm resolution, 3x magnification, and a working distance of 600 mm for in-situ sample alignment and X-ray beam visualization for the Inelastic X-ray Scattering (IXS) beamline at NSLS-II is presented. The microscope uses reflective optics, which minimizes dispersion, and allows imaging from Ultraviolet (UV) to Infrared (IR) with specifically chosen objective components (coatings, etc.). Additionally, a portable high resolution X-ray microscope for KB mirror alignment and X-ray beam characterization was developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mesoscale structural gradients in human tooth enamel

The outstanding mechanical and chemical properties of dental enamel emerge from its complex hierarchical architecture. An accurate, detailed multiscale model of the structure and composition of enamel is important for understanding lesion formation in tooth decay (dental caries), enamel development (amelogenesis) and associated pathologies (e.g., amelogenesis imperfecta or molar hypomineralization), and minimally invasive dentistry. Although features at length scales smaller than 100 nm (individual crystallites) and greater than 50 µm (multiple rods) are well understood, competing field of view and sampling considerations have hindered exploration of mesoscale features, i.e., at the level of single enamel rods and the interrod enamel (1 to 10 µm). Here, we combine synchrotron X-ray diffraction at submicrometer resolution, analysis of crystallite orientation distribution, and unsupervised machine learning to show that crystallographic parameters differ between rod head and rod tail/interrod enamel. This variation strongly suggests that crystallites in different microarchitectural domains also differ in their composition. Thus, we use a dilute linear model to predict the concentrations of minority ions in hydroxylapatite (Mg 2+ and CO 3 2- /Na + ) that plausibly explain the observed lattice parameter variations. While differences within samples are highly significant and of similar magnitude, absolute values and the sign of the effect for some crystallographic parameters show interindividual variation that warrants further investigation. In conclusion, by revealing additional complexity at the rod/interrod level of human enamel and leaving open the possibility of modulation across larger length scales, these results inform future investigations into mechanisms governing amelogenesis and introduce another feature to consider when modeling the mechanical and chemical performance of enamel.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Distributionally Safe Path Planning: Wasserstein Safe RRT

In this paper, we propose a Wasserstein metric-based random path planning algorithm. Wasserstein Safe RRT (W-Safe RRT) provides finite-sample probabilistic guarantees on the safety of a returned path in an uncertain obstacle environment. Vehicle and obstacle states are modeled as distributions based upon state and model observations. Additionally, we define limits on distributional sampling error so the Wasserstein distance between a vehicle state distribution and obstacle distributions can be bounded. This enables the algorithm to return safe paths with a confidence bound through combining finite sampling error bounds with calculations of the Wasserstein distance between discrete distributions. W-Safe RRT is compared against a baseline minimum encompassing ball algorithm, which ensures balls that minimally encompass discrete state and obstacle distributions do not overlap. The improved performance is verified in a 3D environment using single, multi, and rotating non-convex obstacle cases, with and without forced obstacle error in adversarial directions, showing that W-Safe RRT can handle poorly modeled complex environments.

42 ENGINEERING↗

Development and evaluation of an efficient approach to volumetric arc therapy planning

An efficient method for volumetric intensity modulated arc therapy (VMAT) planning was developed, where a single arc (360 deg. or less) is delivered under continuous variation of multileaf collimator (MLC) segments, dose rate, and gantry speed. Plans can be generated for any current linear accelerator that supports these degrees of freedom. MLC segments are derived from fluence maps at relatively coarsely sampled angular positions. The beam segments, dose rate, and gantry speed are then optimized using direct machine parameter optimization based on dose volume objectives and leaf motion constraints to minimize arc delivery time. The method can vary both dose rate and gantry speed or alternatively determine the optimal plan at constant dose rate and gantry speed. The method was used to retrospectively generate variable dose rate VMAT plans to ten patients (head and neck, prostate, brain, lung, and tonsil). In comparison to step-and-shoot intensity modulated radiation therapy, dosimetric plan quality was comparable or improved, estimated delivery times ranged from 70 to 160 s, and monitor units were consistently reduced in nine out of the ten cases by an average of {approx}6%. Optimization and final dose calculation took between 5 and 35 min depending on plan complexity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lead Slowing-Down Spectrometry for Spent Fuel Assay: FY11 Status Report

Executive Summary Developing a method for the accurate, direct, and independent assay of the fissile isotopes in bulk materials (such as used fuel) from next-generation domestic nuclear fuel cycles is a goal of the Office of Nuclear Energy, Fuel Cycle R&D, Material Protection and Control Technology (MPACT) Campaign. To meet this goal, MPACT supports a multi-institutional collaboration to study the feasibility of Lead Slowing Down Spectroscopy (LSDS). This technique is an active nondestructive assay method that has the potential to provide independent, direct measurement of Pu and U isotopic masses in used fuel with an uncertainty considerably lower than the approximately 10% typical of today’s confirmatory assay methods. This document is a progress report for FY2011 collaboration activities. Progress made by the collaboration in FY2011 continues to indicate the promise of LSDS techniques applied to used fuel. PNNL developed an empirical model based on calibration of the LSDS to responses generated from well-characterized used fuel. The empirical model demonstrated the potential for the direct and independent assay of the sum of the masses of 239Pu and 241Pu to within approximately 3% over a wide used fuel parameter space. Similar results were obtained using a perturbation approach developed by LANL. Benchmark measurements have been successfully conducted at LANL and at RPI using their respective LSDS instruments. The ISU and UNLV collaborative effort is focused on the fabrication and testing of prototype fission chambers lined with ultra-depleted 238U and 232Th, and uranium deposition on a stainless steel disc using spiked U3O8 from room temperature ionic liquid was successful, with improving thickness obtained. In FY2012, the collaboration plans a broad array of activities. PNNL will focus on optimizing its empirical model and minimizing its reliance on calibration data, as well continuing efforts on developing an analytical model. Additional measurements are planned at LANL and RPI. LANL measurements will include a Pu sample, which is expected to provide more counts at longer slowing-down times to help identify discrepancies between experimental data and MCNPX simulations. RPI measurements will include the assay of an entire fresh fuel assembly for the study of self-shielding effects as well as the ability to detect diversion by detecting a missing fuel pin in the fuel assembly. The development of threshold neutron sensors will continue, and UNLV will calibrate existing ultra-depleted uranium deposits at ISU.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Behavior of Mercury During DWPF Chemical Process Cell Processing

The Defense Waste Processing Facility has experienced significant issues with the stripping and recovery of mercury in the Chemical Processing Cell (CPC). The stripping rate has been inconsistent, often resulting in extended processing times to remove mercury to the required endpoint concentration. The recovery of mercury in the Mercury Water Wash Tank has never been high, and has decreased significantly since the Mercury Water Wash Tank was replaced after the seventh batch of Sludge Batch 5. Since this time, essentially no recovery of mercury has been seen. Pertinent literature was reviewed, previous lab-scale data on mercury stripping and recovery was examined, and new lab-scale CPC Sludge Receipt and Adjustment Tank (SRAT) runs were conducted. For previous lab-scale data, many of the runs with sufficient mercury recovery data were examined to determine what factors affect the stripping and recovery of mercury and to improve closure of the mercury material balance. Ten new lab-scale SRAT runs (HG runs) were performed to examine the effects of acid stoichiometry, sludge solids concentration, antifoam concentration, form of mercury added to simulant, presence of a SRAT heel, operation of the SRAT condenser at higher than prototypic temperature, varying noble metals from none to very high concentrations, and higher agitation rate. Data from simulant runs from SB6, SB7a, glycolic/formic, and the HG tests showed that a significant amount of Hg metal was found on the vessel bottom at the end of tests. Material balance closure improved from 12-71% to 48-93% when this segregated Hg was considered. The amount of Hg segregated as elemental Hg on the vessel bottom was 4-77% of the amount added. The highest recovery of mercury in the offgas system generally correlated with the highest retention of Hg in the slurry. Low retention in the slurry (high segregation on the vessel bottom) resulted in low recovery in the offgas system. High agitation rates appear to result in lower retention of mercury in the slurry. Both recovery of mercury in the offgas system and removal (segregation + recovery) from the slurry correlate with slurry consistency. Higher slurry consistency results in better retention of Hg in the slurry (less segregation) and better recovery in the offgas system, but the relationships of recovery and retention with consistency are sludge dependent. Some correlation with slurry yield stress and acid stoichiometry was also found. Better retention of mercury in the slurry results in better recovery in the offgas system because the mercury in the slurry is stripped more easily than the segregated mercury at the bottom of the vessel. Although better retention gives better recovery, the time to reach a particular slurry mercury content (wt%) is longer than if the retention is poorer because the segregation is faster. The segregation of mercury is generally a faster process than stripping. The stripping factor (mass of water evaporated per mass of mercury stripped) of mercury at the start of boiling were found to be less than 1000 compared to the assumed design basis value of 750 (the theoretical factor is 250). However, within two hours, this value increased to at least 2000 lb water per lb Hg. For runs with higher mercury recovery in the offgas system, the stripping factor remained around 2000, but runs with low recovery had stripping factors of 4000 to 40,000. DWPF data shows similar trends with the stripping factor value increasing during boiling. These high values correspond to high segregation and low retention of mercury in the sludge. The stripping factor for a pure Hg metal bead in water was found to be about 10,000 lb/lb. About 10-36% of the total Hg evaporated in a SRAT cycle was refluxed back to the SRAT during formic acid addition and boiling. Mercury is dissolved as a result of nitric acid formation from absorption of NO x . The actual solubility of dissolved mercury in the acidic condensate is about 100 times higher than the actual concentrations measured. Mercury metal present in the MWWT from previous batches could be dissolved by this acidic condensate. The test of the effect of higher SRAT condenser temperature on recovery of mercury in the MWWT and offgas system was inconclusive. The recovery at higher temperature was lower than several low temperature runs, but about the same as other runs. Factors other than temperature appear to affect the mercury recovery. The presence of chloride and iodide in simulants resulted in the formation of mercurous chloride and mercurous iodide, respectively, in the offgas system. Actual waste data shows that the chloride content is much less than the simulant concentrations. Future simulant tests should minimize the addition of chloride. Similarly, iodine addition should be eliminated unless actual waste analyses show it to be present; currently, total iodine is not measured on actual waste samples.

36 MATERIALS SCIENCE↗

Fielding the magnetically applied pressure-shear technique on the Z accelerator (completion report for MRT 4519).

The recently developed Magnetically Applied Pressure-Shear (MAPS) experimental technique to measure material shear strength at high pressures on magneto-hydrodynamic (MHD) drive pulsed power platforms was fielded on August 16, 2013 on shot Z2544 utilizing hardware set A0283A. Several technical and engineering challenges were overcome in the process leading to the attempt to measure the dynamic strength of NNSA Ta at 50 GPa. The MAPS technique relies on the ability to apply an external magnetic field properly aligned and time correlated with the MHD pulse. The load design had to be modified to accommodate the external field coils and additional support was required to manage stresses from the pulsed magnets. Further, this represents the first time transverse velocity interferometry has been applied to diagnose a shot at Z. All subsystems performed well with only minor issues related to the new feed design which can be easily addressed by modifying the current pulse shape. Despite the success of each new component, the experiment failed to measure strength in the samples due to spallation failure, most likely in the diamond anvils. To address this issue, hydrocode simulations are being used to evaluate a modified design using LiF windows to minimize tension in the diamond and prevent spall. Another option to eliminate the diamond material from the experiment is also being investigated.

Alexander, C. Scott↗

Extreme-Scale Distribution-Based Data Analysis

Scientists overview and identify regions of interest by transforming data into compact information descriptors that characterize simulation results and allow detailed analysis on demand. Among many existing feature descriptors, statistical information derived from data samples is a promising approach to taming the big data avalanche because data distributionscomputed from a population can compactly describe the presence and characteristics of salient data features with minimal data movement. The ability to computationally summarize and process data using distributions also provides an efficient and representative capture of information that can adjust to size and resource constraints, with the added benefit that uncertainty associated with results can be quantified and communicated. In this project, we have developed a distribution-based data analysis and visualization framework for optimizing in situ processing and analysis of extreme-scale scientific data.

97 MATHEMATICS AND COMPUTING↗

Gradient-based Optimization for Regression in the Functional Tensor-Train Format

We consider the task of low-multilinear-rank functional regression, i.e., learning a low-rank parametric representation of functions from scattered real-valued data. Our first contribution is the development and analysis of gradient-based optimization procedures, including stochastic gradient descent and quasi-Newton methods, for learning the parameters of a functional tensor-train (FT) that yields improved accuracy over standard alternating least squares methods. The functional tensor-train uses the tensor-train (TT) representation of low-rank arrays as an ansatz for a class of low-multilinear-rank functions. The FT is represented by a set of matrix-valued functions that contain a set of univariate functions, and the regression task is to learn the parameters of these univariate functions. Our second contribution demonstrates that using nonlinearly parameterized univariate functions, e.g., symmetric kernels with moving centers, within each core can outperform the standard approach of using a linear expansion of basis functions. Our final contributions are new rank adaptation and group-sparsity regularization procedures to minimize overfitting. We use several benchmark problems to demonstrate at least an order of magnitude lower accuracy with gradient-based optimization methods than ALS in the low-sample number regime. We also demonstrate an order of magnitude reduction in accuracy on a test problem resulting from nonlinear parameterizations over linear parameterizations. Finally we compare regression performance with 22 other nonparametric and parametric regression methods on 10 real-world data sets. We achieve top-five accuracy for seven of the data sets and best accuracy for two of the data sets. These rankings are the best amongst parametric models and competetive with the best non-parametric methods.

97 MATHEMATICS AND COMPUTING↗