Search NASA⌕ Search

SEARCH · Search NASA

Results for “sample size”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Chaos: Understanding and Controlling Laser Instability

In order to characterize the behavior of tunable diode lasers (TDL), the first step in the project involved the redesign of the TDL system here at the University of Tennessee Molecular Systems Laboratory (UTMSL). Having made these changes it was next necessary to optimize the new optical system. This involved the fine adjustments to the optical components, particularly in the monochromator, to minimize the aberrations of coma and astigmatism and to assure that the energy from the beam is focused properly on the detector element. The next step involved the taking of preliminary data. We were then ready for the analysis of the preliminary data. This required the development of computer programs that use mathematical techniques to look for signatures of chaos. Commercial programs were also employed. We discovered some indication of high dimensional chaos, but were hampered by the low sample rate of 200 KSPS (kilosamples/sec) and even more by our sample size of 1024 (1K) data points. These limitations were expected and we added a high speed data acquisition board. We incorporated into the system a computer with a 40 MSPS (million samples/sec) data acquisition board. This board can also capture 64K of data points so that were then able to perform the more accurate tests for chaos. The results were dramatic and compelling, we had demonstrated that the lead salt diode laser had a chaotic frequency output. Having identified the chaotic character in our TDL data, we proceeded to stage two as outlined in our original proposal. This required the use of an Occasional Proportional Feedback (OPF) controller to facilitate the control and stabilization of the TDL system output. The controller was designed and fabricated at GSFC and debugged in our laboratories. After some trial and error efforts, we achieved chaos control of the frequency emissions of the laser. The two publications appended to this introduction detail the entire project and its results.

Blass, William E.↗

Summary of Proton Test on the Actel A1280A at Indiana University

A summary of tests performed at the Indiana University Cycl,oltron Facility, on the Actel A1280A circuit device is described. The intent of the study was to investigate the proton response of the hard-wired S-Module flip-flops with a large sample size. This device is sensitive to protons for S-Modules. The device's performance in the test is shown in graphs, and was typical for devices of this class.

Katz, Richard↗

Evaluation of Various Depainting Processes on Mechanical Properties of 2024-T3 Aluminum Substrate

Alternate alkaline and neutral chemical paint strippers have been identified that, with respect to corrosion requirements, perform as well as or better than a methylene chloride baseline. These chemicals also, in general, meet corrosion acceptance criteria as specified in SAE MA 4872. Alternate acid chemical paint strippers have been identified that, with respect to corrosion requirements, perform as well as or better than a methylene chloride baseline. However, these chemicals do not generally meet corrosion acceptance criteria as specified in SAE MA 4872, especially in the areas of non-clad material performance and hydrogen embrittlement. Media blast methods reviewed in the study do not, in general, adversely affect fatigue performance or crack detectability of 2024-T3 substrate. Sodium bicarbonate stripping exhibited a tendency towards inhibiting crack detectability. These generalizations are based on a limited sample size and additional testing should be performed to characterize the response of specific substrates to specific processes.

McGill, P.↗

Evaluation of the 29-km Eta Model: Objective Verification at Three Selected Stations - Part 1

This paper describes an objective verification of the National Centers for Environmental Prediction (NCEP) 29-km eta model from May 1996 through January 1998. The evaluation was designed to assess the model's surface and upper-air point forecast accuracy at three selected locations during separate warm (May - August) and cool (October - January) season periods. In order to enhance sample sizes available for statistical calculations, the objective verification includes two consecutive warm and cool season periods. Systematic model deficiencies comprise the larger portion of the total error in most of the surface forecast variables that were evaluated. The error characteristics for both surface and upper-air forecasts vary widely by parameter, season, and station location. At upper levels, a few characteristic biases are identified. Overall however, the upper-level errors are more nonsystematic in nature and could be explained partly by observational measurement uncertainty. With a few exceptions, the upper-air results also indicate that 24-h model error growth is not statistically significant. In February and August 1997, NCEP implemented upgrades to the eta model's physical parameterizations that were designed to change some of the model's error characteristics near the surface. The results shown in this paper indicate that these upgrades led to identifiable and statistically significant changes in forecast accuracy for selected surface parameters. While some of the changes were expected, others were not consistent with the intent of the model updates and further emphasize the need for ongoing sensitivity studies and localized statistical verification efforts. Objective verification of point forecasts is a stringent measure of model performance, but when used alone, is not enough to quantify the overall value that model guidance may add to the forecast process. Therefore, results from a subjective verification of the meso-eta model over the Florida peninsula are discussed in the companion paper by Manobianco and Nutter. Overall verification results presented here and in part two should establish a reasonable benchmark from which model users and developers may pursue the ongoing eta model verification strategies in the future.

Nutter, Paul A.↗

Smoldering, Transition and Flaming in Microgravity

A research project is underway to study smolder and the transition to flaming in microgravity. The Microgravity Smoldering Combustion (MSC) flight project is an ongoing research project to provide a better understanding of the controlling mechanisms of smoldering combustion. The Smoldering Transition and Flaming (STAF) project is a recently established research program that will utilize the Fluids and Combustion Facility (FCF) of the ISS to examine the transition from smolder to flaming in microgravity. In forced flow smolder experiments ambient pressure in the MSC chamber rises, thus motivating the need to understand the effects of pressure on smoldering combustion. Further, the STAF experiment has constraints on experimental scale and testing at elevated pressure may be a mechanism to reduce the sample size by enhancing the smolder reaction. In the work we are reporting here, a series of ground-based tests determine the effects of pressure on smoldering combustion. These tests are compared with data obtained from experiments conducted aboard the Space Shuttle in flights STS-69 and STS-77. Measurements of one-dimensional smolder propagation velocity are made by thermocouple probing and a non-intrusive Ultrasound Imaging System (UIS)]. Thermocouples are also used to obtain reaction temperatures and the UIS is used to determine permeabilities of the fuel in real-time.

Fernandez-Pello, A. C.↗

Application of Fe Isotopes to the Search for Life and Habitable Planets

The relatively new field of Fe isotope geochemistry can make important contributions to tracing the geochemical cycling of Fe, which bears on issues such as metabolic processing of Fe, surface redox conditions, and development of planetary atmospheres and biospheres. It appears that Fe isotope fractionation in nature and the lab spans about 4 per mil (%) in Fe-56/Fe-54, and although this range is small, our new analytical methods produce a precision of +/- 0.05% on sample sizes as small as 100 ng (10(exp -7) g); this now provides us with a sufficient "signal-to-noise" ratio to make this isotope system useful. We review our work in three areas: 1) the terrestrial and lunar rock record, 2) experiments on inorganic fractionation, and 3) experiments involving biological processing of Fe. Additional information is contained in the original extended abstract.

Johnson, Clark M.↗

An Experimental Study of the Effects of Automation on Pilot Situational Awareness in the Datalink ATC Environment

An experiment to study how automation, when used in conjunction with datalink for the delivery of air traffic control (ATC) clearance amendments, affects the situational awareness of aircrews was conducted. The study was focused on the relationship of situational awareness to automated Flight Management System (FMS) programming and the readback of ATC clearances. Situational awareness was tested by issuing nominally unacceptable ATC clearances and measuring whether the error was detected by the subject pilots. The experiment also varied the mode of clearance delivery: Verbal, Textual, and Graphical. The error detection performance and pilot preference results indicate that the automated programming of the FMS may be superior to manual programming. It is believed that automated FMS programming may relieve some of the cognitive load, allowing pilots to concentrate on the strategic implications of a clearance amendment. Also, readback appears to have value, but the small sample size precludes a definite conclusion. Furthermore, because textual and graphical modes of delivery offer different but complementary advantages for cognitive processing, a combination of these modes of delivery may be advantageous in a datalink presentation.

Hahn, Edward C.↗

Probabilistic Life and Reliability Analysis of Model Gas Turbine Disk

In 1939, W. Weibull developed what is now commonly known as the "Weibull Distribution Function" primarily to determine the cumulative strength distribution of small sample sizes of elemental fracture specimens. In 1947, G. Lundberg and A. Palmgren, using the Weibull Distribution Function developed a probabilistic lifing protocol for ball and roller bearings. In 1987, E. V. Zaretsky using the Weibull Distribution Function modified the Lundberg and Palmgren approach to life prediction. His method incorporates the results of coupon fatigue testing to compute the life of elemental stress volumes of a complex machine element to predict system life and reliability. This paper examines the Zaretsky method to determine the probabilistic life and reliability of a model gas turbine disk using experimental data from coupon specimens. The predicted results are compared to experimental disk endurance data.

Holland, Frederic A.↗

Incorporating Biological Knowledge into Evaluation of Casual Regulatory Hypothesis

Biological data can be scarce and costly to obtain. The small number of samples available typically limits statistical power and makes reliable inference of causal relations extremely difficult. However, we argue that statistical power can be increased substantially by incorporating prior knowledge and data from diverse sources. We present a Bayesian framework that combines information from different sources and we show empirically that this lets one make correct causal inferences with small sample sizes that otherwise would be impossible.

Chrisman, Lonnie↗

An Exploration of Discontinuous Time Synchronous Averaging for Helicopter HUMS Using Cruise and Terminal Area Vibration Data

Recent research using NASA Ames AH-1 and OH-58C helicopters, and NASA Glenn test rigs, has shown that in-flight vibration data are typically non-stationary [l-4]. The nature and extent of this non-stationarity is most likely produced by several factors operating simultaneously. The aerodynamic flight environment and pilot commands provide continuously changing inputs, with a complex dynamic response that includes automatic feedback control from the engine regulator. It would appear that the combined effects operate primarily through an induced torque profile, which causes concomitant stress modulation at the individual internal gear meshes in the transmission. This notion is supported by several analyses, which show that upwards of 93% of the vibration signal s variance can be explained by knowledge of torque alone. That this relationship is stronger in an AH-1 than an OH-58, where measured non-stationarity is greater, suggests that the overall mass of the vehicle is an important consideration. In the lighter aircraft, the unsteady aerodynamic influences transmit relatively greater unsteady dynamic forces on the mechanical components, quite possibly contributing to its greater non-stationarity . In a recent paper using OH-58C pinion data [5], the authors have shown that in computing a time synchronous average (TSA) for various single-value metric computations, an effective trade-off can be obtained between sample size and measured stationarity by using data from only a single mesh cycle. A mesh cycle, which is defined as the number of rotations required for the gear teeth to return to their original mating position, has the property of representing all of the discrete phase angles of the opposing gears exactly once in the average. Measured stationarity is probably maximized because a single mesh cycle of the pinion gear occurs over a very short span of time, during which time-dependent non-stationary effects are kept to a minimum. Clearly, the advantage of local stationarity diminishes as the temporal duration of the cycle increases. This is most evident for a planetary mesh cycle, which can take several minutes to complete.

Huff, Edward M.↗

Analysis of Near Simultaneous Jimsphere and AMPS High Resolution Wind Profiles

The high-resolution wind profile of the Automated Meteorological Profiling System (HRAMPS) is the proposed replacement for the Jimsphere measurement system used to support NASA Shuttle launches from the Eastern Test Range (ETR). Samples of twenty-six ETR near simultaneous Jimsphere and HRAMPS wind profiles were obtained for Shuttle program HRAMPS certification studies. Shuttle systems engineering certification is to ensure that spacecraft and launch vehicle systems performance and safety evaluations for each launch (derived from flight simulations with Jimsphere wind profile data bases) retain their validity when HRAMPS profiles are used on day-of-launch (DOL) in trajectory and loads simulations to support the commit-to-launch decision. This paper describes a statistical analysis of the near simultaneous profiles. In principle the differences between a Jimsphere profile and an HRAMPS profile should be attributed to tracking technology (radar versus GPS tracking of a Jimsphere flight element) and the method for derivation of wind vectors from the raw tracking data. In reality, it is not technically feasible to track the same Jimsphere balloon with the two systems. The aluminized Mylar surface of the standard Jimsphere flight element facilitates radar tracking, but it interferes with HRAMPS during simultaneous tracking. Suspending a radar reflector from an HRAMPS flight element (Jimsphere without aluminized coating) does not produce satisfactory Jimsphere profiles because of intermittent radar returns. Thus, differences between the Jimsphere and HRAMPS profiles are also attributed to differences in the trajectories of separate flight elements. Because of small sample size and a test period limited to one winter season, test measurements during extreme high winds aloft could not have been expected and did not occur. It is during the highest winds that the largest differences between Jimsphere and HRAMPS would occur because the distance between flight elements would be larger. Jimsphere radar tracking noise increases as a function of balloon displacement downrange. The Jimsphere data processing compensates for tracking signal/noise degradation by increasing the smoothing interval. The Jimsphere wind profile effective resolution is a function of downrange distance and altitude, whereas the effective resolution of the HRAMPS should be independent of those variables. The procedure used for editing Jimsphere spikes in Shuttle DOL profiles was not implemented for the Jimsphere profile measurements during the AMPS field tests. For this analysis a code was developed that essentially mimics DOL Jimsphere spike editing. Jimsphere profiles have somewhat more noise in the wavelength range less than 200m defined as the noise floor. No differences between Jimsphere and HRAMPS wind profile pairs have been found that would support denial of HRAMPS certification for application in Shuttle DOL applications. The reliability of the HRAMPS system, which is an important certification issue, is not addressed in this study.

Adelfang, S. I.↗

Microgravity Smoldering Combustion on the USML-1 Space Shuttle Mission

Preliminary results from an experimental study of the smolder characteristics of a porous combustible material (flexible polyurethane foam) in normal and microgravity are presented. The experiments, limited in fuel sample size and power available for ignition, show that the smolder process was primarily controlled by heat losses from the reaction to the surrounding environment. In microgravity, the reduced heat losses due to the absence of natural convection result in only slightly higher temperatures in the quiescent microgravity test than in normal gravity but a dramatically larger production of combustion products in all microgravity tests. Particularly significant is the proportionately larger amount of carbon monoxide and light organic compounds produced in microgravity, despite comparable temperatures and similar char patterns. This excessive production of fuel-rich combustion products may be a generic characteristic of smoldering polyurethane in microgravity, with an associated increase in the toxic hazard of smolder in spacecraft.

Stocker, Dennis P.↗

Mars Data Analysis Program

Grant NAGS12158 addressed a major NASA objective concerning the possibility of a palm ocean or large lake in the northern lowlands of Mars. Our overall approach for this study was an analysis of the graben-bounded giant polygons of Utopia Planitia, but specifically those grabens that define circles rather than open polygons. These circular grabens overlie buried impact craters, and the grabens form because of differential compaction of the overlying material over crater rims and floors. Several years ago, I predicted that the graben circles would bound depressions, and that the depths of these depressions would scale with the diameters of the graben circles. These predictions have been verified by earlier analysis. During this one-year grant (with one-year no-cost extension) we greatly increased the sample size and validated the earlier research robustly. What remained unexplained was why most of the graben circles in Utopia Planitia were double. A new model, involving volumetric compaction rather than simply 2-D compaction, satisfactorily explains the double rings and also provides a measure of relative thickness of the cover material burying the craters as a function of radial distance from the center of the Utopia Basin. Only two materials are likely candidates for the compacting cover material: volcanic ash, or wet sediment. The water in the wet sediment is largely responsible for the volumetric compaction; dry ash will compact vertically but experiences very limited lateral shrinkage. Thus the depressions within the circular grabens and the model explaining the double rings strongly favor wet sediment and thus provide evidence in favor of a past body of standing water in the northern lowlands. Publications supported entirely or in part by this grant are listed below.

McGill, George E.↗

A phase response curve to single bright light pulses in human subjects

The circadian pacemaker is differentially sensitive to the resetting effects of retinal light exposure, depending upon the circadian phase at which the light exposure occurs. Previously reported human phase response curves (PRCs) to single bright light exposures have employed small sample sizes, and were often based on relatively imprecise estimates of circadian phase and phase resetting. In the present study, 21 healthy, entrained subjects underwent pre- and post-stimulus constant routines (CRs) in dim light (approximately 2-7 lx) with maintained wakefulness in a semi-recumbent posture. The 6.7 h bright light exposure stimulus consisted of alternating 6 min fixed gaze (approximately 10 000 lx) and free gaze (approximately 5000-9000 lx) exposures. Light exposures were scheduled across the circadian cycle in different subjects so as to derive a PRC. Plasma melatonin was used to determine the phase of the onset, offset, and midpoint of the melatonin profiles during the CRs. Phase shifts were calculated as the difference in phase between the pre- and post-stimulus CRs. The resultant PRC of the midpoint of the melatonin rhythm revealed a characteristic type 1 PRC with a significant peak-to-trough amplitude of 5.02 h. Phase delays occurred when the light stimulus was centred prior to the critical phase at the core body temperature minimum, phase advances occurred when the light stimulus was centred after the critical phase, and no phase shift occurred at the critical phase. During the subjective day, no prolonged 'dead zone' of photic insensitivity was apparent. Phase shifts derived using the melatonin onsets showed larger magnitudes than those derived from the melatonin offsets. These data provide a comprehensive characterization of the human PRC under highly controlled laboratory conditions.

Randomized Controlled Trial↗

Measuring sleep habits without using a diary: the sleep timing questionnaire

STUDY OBJECTIVES: To develop a single-administration instrument yielding equivalent measures of sleep to those obtained from a formal (2-week) sleep diary. DESIGN & SETTING: A single-administration Sleep riming Questionnaire (STQ) is described (and reproduced in the Appendix). Test-retest reliability was examined in 40 subjects who were given the STQ on two occasions separated by less than 1 year. Convergent validity was measured both by comparing STO-derived measures with objective measures derived from wrist actigraphy (n=23) and by comparing STQ-derived measures with other subjective measures derived from a detailed 2-week sleep diary in two nonoverlapping samples (n=101, 93). Correlations of STQ measures with age and momingness-eveningness (chronotype) were also examined. SUBJECTS: The analyses used sample sizes of 40, 23, 101, and 93 (both genders, overall age range 20y-89y). Most subjects were healthy volunteers; some Study 4 subjects were patients (enrolled in research protocols). RESULTS: Test-retest reliability for the STQ was demonstrated for estimates of bedtime (r = 0.705, p < 0.001) and waketime (r = 0.826, p < 0.001). Convergent validity using wrist actigraphy was demonstrated by correlations of 0.592 (p < 0.005) for bedtime, and of 0.769 (p < 0.001) for waketime. Diary studies indicated STQ bedtime and waketime data to be highly correlated (at about 0.8) with those obtained from a formal 2-week sleep diary. The STQ also provided data on estimated sleep latency and wake after sleep onset (WASO), which correlated reliably (at about 0.7) with average nightly ratings of these variables from a 2-week sleep diary. Mean estimated values of sleep latency and WASO from the two instruments were within 1 minute of each other. ST-derived bedtimes and waketimes correlated with both age and chronotype in the expected direction (older subjects earlier, morning types earlier). CONCLUSION: The STQ may be a reliable valid measure of sleep timing that could provide a time-efficient alternative to traditional sleep diaries.

Validation Studies↗

A simple way to measure daily lifestyle regularity

A brief diary instrument to quantify daily lifestyle regularity (SRM-5) is developed and compared with a much longer version of the instrument (SRM-17) described and used previously. Three studies are described. In Study 1, SRM-17 scores (2 weeks) were collected from a total of 293 healthy control subjects (both genders) aged between 19 and 92 years. Five items (1) Get out of bed, (2) First contact with another person, (3) Start work, housework or volunteer activities, (4) Have dinner, and (5) Go to bed were then selected from the 17 items and SRM-5 scores calculated as if these five items were the only ones collected. Comparisons were made with SRM-17 scores from the same subject-weeks, looking at correlations between the two SRM measures, and the effects of age and gender on lifestyle regularity as measured by the two instruments. In Study 2 this process was repeated in a group of 27 subjects who were in remission from unipolar depression after treatment with psychotherapy and who completed SRM-17 for at least 20 successive weeks. SRM-5 and SRM-17 scores were then correlated within an individual using time as the random variable, allowing an indication of how successful SRM-5 was in tracking changes in lifestyle regularity (within an individual) over time. In Study 3 an SRM-5 diary instrument was administered to 101 healthy control subjects (both genders, aged 20-59 years) for two successive weeks to obtain normative measures and to test for correlations with age and morningness. Measures of lifestyle regularity from SRM-5 correlated quite well (about 0.8) with those from SRM-17 both between subjects, and within-subjects over time. As a detector of irregularity as defined by SRM-17, the SRM-5 instrument showed acceptable values of kappa (0.69), sensitivity (74%) and specificity (95%). There were, however, differences in mean level, with SRM-5 scores being about 0.9 units [about one standard deviation (SD)] above SRM-17 scores from the same subject-weeks. SRM-5 scores also deviated more from a Gaussian distribution than did SRM-17 ones. In a study with a sample size of 101, the new SRM-5 instrument yielded scores with a mean of 4.11 and an SD of 1.13. Correlations between lifestyle regularity and age, and between lifestyle regularity and morningness appeared similar whether 5-item or 17-item SRM measures were used. When a gender difference in lifestyle regularity appeared, it was detected by both SRM-5 and SRM-17 measures.

Non-NASA Center↗

Low irradiances affect abscisic acid, indole-3-acidic acid, and cytokinin levels of wheat (Triticum aestivum L.) tissues

Wheat (Triticum aestivum L.) plants were grown under four irradiance levels: 1,400, 400, 200, and 100 micromol m-2 s-1. Leaves and roots were sampled before, during, and after the boot stage, and levels of abscisic acid (ABA), indole-3-acetic acid (IAA), zeatin, zeatin riboside, dihydrozeatin, dihydrozeatin riboside, isopentenyl adenine, and isopentenyl adenosine were quantified using noncompetitive indirect ELISA systems. Levels of IAA in leaves and roots of plants exposed to 100 micromol m-2 s-1 of irradiance were 0.7 and 2.9 micromol kg-1 dry mass (DM), respectively. These levels were 0.2 and 1.0 micromol kg-1 DM, respectively, when plants were exposed to 1,400 micromol m-2 s-1. Levels of ABA in leaves and roots of plants exposed to 100 micromol m-2 s-1 were 0.65 and 0.55 micromol kg-1 DM, respectively. They were 0.24 micromol kg-1 DM (both leaves and roots) when plants were exposed to 1,400 micromol m-2 s-1. Levels of isopentenyl adenosine in leaves (24.3 nmol kg-1 DM) and roots (29.9 nmol kg-1 DM) were not affected by differences in the irradiance regime. Similar values were obtained in a second experiment. Other cytokinins could not be detected (<10 nmol kg 1 DM) in either experiment with the sample sizes used (150-600 mg DM for roots and shoots, respectively).

Non-NASA Center↗

Advanced imaging of the macrostructure and microstructure of bone

Noninvasive and/or nondestructive techniques are capable of providing more macro- or microstructural information about bone than standard bone densitometry. Although the latter provides important information about osteoporotic fracture risk, numerous studies indicate that bone strength is only partially explained by bone mineral density. Quantitative assessment of macro- and microstructural features may improve our ability to estimate bone strength. The methods available for quantitatively assessing macrostructure include (besides conventional radiographs) quantitative computed tomography (QCT) and volumetric quantitative computed tomography (vQCT). Methods for assessing microstructure of trabecular bone noninvasively and/or nondestructively include high-resolution computed tomography (hrCT), micro-computed tomography (muCT), high-resolution magnetic resonance (hrMR), and micromagnetic resonance (muMR). vQCT, hrCT and hrMR are generally applicable in vivo; muCT and muMR are principally applicable in vitro. Although considerable progress has been made in the noninvasive and/or nondestructive imaging of the macro- and microstructure of bone, considerable challenges and dilemmas remain. From a technical perspective, the balance between spatial resolution versus sampling size, or between signal-to-noise versus radiation dose or acquisition time, needs further consideration, as do the trade-offs between the complexity and expense of equipment and the availability and accessibility of the methods. The relative merits of in vitro imaging and its ultrahigh resolution but invasiveness versus those of in vivo imaging and its modest resolution but noninvasiveness also deserve careful attention. From a clinical perspective, the challenges for bone imaging include balancing the relative advantages of simple bone densitometry against the more complex architectural features of bone or, similarly, the deeper research requirements against the broader clinical needs. The considerable potential biological differences between the peripheral appendicular skeleton and the central axial skeleton have to be addressed further. Finally, the relative merits of these sophisticated imaging techniques have to be weighed with respect to their applications as diagnostic procedures requiring high accuracy or reliability on one hand and their monitoring applications requiring high precision or reproducibility on the other. Copyright 2000 S. Karger AG, Basel.

NASA Discipline Musculoskeletal↗