Effect of Te Inclusions in CdZnTe Crystals at Different Temperatures

CdZnTe crystals often exhibit nonuniformities due to the presence of Te inclusions and dislocations. High concentrations of such defects in these crystals generally entail severe charge-trapping, a major problem in ensuring the device's satisfactory performance. In this study, we employed a high-intensity, high-spatial-resolution synchrotron x-ray beam as the ideal tool to generate charges by focusing it over the large Te inclusions, and then observing the carrier's response at room- and at low-temperatures. A high spatial 5-{micro}m resolution raster scan revealed the fine details of the presence of extended defects, like Te inclusions and dislocations in the CdZnTe crystals. A noticeable change was observed in the efficiency of electron charge collection at low temperature (1 C), but it was hardly altered at room-temperature.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Technical Note: Building a combined cyclotron and MRI facility: Implications for interference

Purpose: With the introduction of hybrid PET/MRI systems, it has become more likely that the cyclotron and MRI systems will be located close to each other. This study considered the interference between a cyclotron and a superconducting MRI system. Methods: Interactions between cyclotrons and MRIs are theoretically considered. The main interference is expected to be the perturbation of the magnetic field in the MRI due to switching on or off the magnetic field of the cyclotron. MR imaging is distorted by a dynamic spatial gradient of an external inplane magnetic field larger than 0.5-0.04 {mu}T/m, depending on the specific MR application. From the design of a cyclotron, it is expected that the magnetic fringe field at large distances behaves as a magnetic dipolar field. This allows estimation of the full dipolar field and its spatial gradients from a single measurement. Around an 18 MeV cyclotron (Cyclone, IBA), magnetic field measurements were performed on 5 locations and compared with calculations based upon a dipolar field model. Results: At the measurement locations the estimated and measured values of the magnetic field component and its spatial gradients of the inplane component were compared, and found to agree within a factor 1.1 for the magnetic field and within a factor of 1.5 for the spatial gradients of the field. In the specific case of the 18 MeV cyclotron with a vertical magnetic field and a 3T superconducting whole body MR system, a minimum distance of 20 m has to be considered to prevent interference. Conclusions: This study showed that a dipole model is sufficiently accurate to predict the interference of a cyclotron on a MRI scanner, for site planning purposes. The cyclotron and a whole body MRI system considered in this study need to be placed more than 20 m apart, or magnetic shielding should be utilized.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The coastal streamflow flux in the Regional Arctic System Model

The coastal streamflow flux from the Arctic drainage basin is an important driver of dynamics in the coupled ice-ocean system. Comprising more than one third of the total freshwater flux into the Arctic Ocean, streamflow is a key component of the regional and global freshwater cycle. To better represent the coupling of the streamflow flux to the ocean, we have developed and applied the RVIC streamflow routing model within the Regional Arctic System Model (RASM). The RASM is a high-resolution regional Earth System Model whose domain includes all of the Arctic drainage basin. Here in this paper, we introduce the RVIC streamflow routing model, detailing its application within RASM and its advancements in terms of representing high-resolution streamflow processes. We evaluate model simulated streamflow relative to in situ observations and demonstrate a method for improving model performance using a simple optimization procedure. We also present a new, spatially and temporally consistent, high-resolution data set of coastal freshwater fluxes for the Arctic drainage basin and surrounding areas that is based on a fully coupled RASM simulation and intended for use in Arctic Ocean modeling applications. This data set is evaluated relative to other coastal streamflow data sets commonly used by the ocean modeling community. We demonstrate that the RASM-simulated streamflow flux better represents the annual cycle than existing data sets, especially in ungauged areas. Finally, we assess the impact that streamflow has on the coupled ice-ocean system, finding that the presence of streamflow leads to reduced sea surface salinity, increased sea surface temperatures, and decreased sea ice thickness.

54 ENVIRONMENTAL SCIENCES↗

Filling in the GAPS: evaluating completeness and coverage of open-access biodiversity databases in the United States

Primary biodiversity data constitute observations of particular species at given points in time and space. Open-access electronic databases provide unprecedented access to these data, but their usefulness in characterizing species distributions and patterns in biodiversity depend on how complete species inventories are at a given survey location and how uniformly distributed survey locations are along dimensions of time, space, and environment. Our aim was to compare completeness and coverage among three open-access databases representing ten taxonomic groups (amphibians, birds, freshwater bivalves, crayfish, freshwater fish, fungi, insects, mammals, plants, and reptiles) in the contiguous United States. We compiled occurrence records from the Global Biodiversity Information Facility (GBIF), the North American Breeding Bird Survey (BBS), and federally administered fish surveys (FFS). In this study, we aggregated occurrence records by 0.1° × 0.1° grid cells and computed three completeness metrics to classify each grid cell as well-surveyed or not. Next, we compared frequency distributions of surveyed grid cells to background environmental conditions in a GIS and performed Kolmogorov–Smirnov tests to quantify coverage through time, along two spatial gradients, and along eight environmental gradients. The three databases contributed >13.6 million reliable occurrence records distributed among >190,000 grid cells. The percent of well-surveyed grid cells was substantially lower for GBIF (5.2%) than for systematic surveys (BBS and FFS; 82.5%). Still, the large number of GBIF occurrence records produced at least 250 well-surveyed grid cells for six of nine taxonomic groups. Coverages of systematic surveys were less biased across spatial and environmental dimensions but were more biased in temporal coverage compared to GBIF data. GBIF coverages also varied among taxonomic groups, consistent with commonly recognized geographic, environmental, and institutional sampling biases. Lastly, this comprehensive assessment of biodiversity data across the contiguous United States provides a prioritization scheme to fill in the gaps by contributing existing occurrence records to the public domain and planning future surveys.

59 BASIC BIOLOGICAL SCIENCES↗

Multiscale design of nonlinear materials using a Eulerian shape optimization scheme

Motivated by recent advances in manufacturing, the design of materials is the focal point of interest in the material research community. One of the critical challenges in this field is finding optimal material microstructure for a desired macroscopic response. This work presents a computational method for the mesoscale-level design of particulate composites for an optimal macroscale-level response. The method relies on a custom shape optimization scheme to find the extrema of a nonlinear cost function subject to a set of constraints. Three key “modules” constitute the method: multiscale modeling, sensitivity analysis, and optimization. Multiscale modeling relies on a classical homogenization method and a nonlinear NURBS-based generalized finite element scheme to efficiently and accurately compute the structural response of particulate composites using a nonconformal discretization. A three-parameter isotropic damage law is used to model microstructure-level failure. An analytical sensitivity method is developed to compute the derivatives of the cost/constraint functions with respect to the design variables that control the microstructure's geometry. The derivation uncovers subtle but essential new terms contributing to the sensitivity of finite element shape functions and their spatial derivatives. Several structural problems are solved to demonstrate the applicability, performance, and accuracy of the method for the design of particulate composites with a desired macroscopic nonlinear stress-strain response.

42 ENGINEERING↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of spatiodemographic estimates produced through data fusion of small area census records and household microdata

Techniques such as Iterative Proportional Fitting have been previously suggested as a means to generate new data with the demographic granularity of individual surveys and the spatial granularity of small area tabulations of censuses and surveys. This article explores internal and external validation approaches for synthetic, small area, household- and individual-level microdata using a case study for Bangladesh. Using data from the Bangladesh Census 2011 and the Demographic and Health Survey, we produce estimates of infant mortality rate and other household attributes for small areas using a variation of an iterative proportional fitting method called P-MEDM. We conduct an internal validation to determine: whether the model accurately recreates the spatial variation of the input data, how each of the variables performed overall, and how the estimates compare to the published population totals. We conduct an external validation by comparing the estimates with indicators from the 2009 Multiple Indicator Cluster Survey (MICS) for Bangladesh to benchmark how well the estimates compared to a known dataset which was not used in the original model. The results indicate that the estimation process is viable for regions that are better represented in the microdata sample, but also revealed the possibility of strong overfitting in sparsely sampled sub-populations.

42 ENGINEERING↗

Three-dimensional direct numerical simulation of a turbulent lifted hydrogen jet flame in heated coflow: flame stabilization and structure

Direct numerical simulation (DNS) of the near field of a three-dimensional spatially developing turbulent lifted hydrogen jet flame in heated coflow is performed with a detailed mechanism to determine the stabilization mechanism and the flame structure. The DNS was performed at a jet Reynolds number of 11,000 with over 940 million grid points. The results show that auto-ignition in a fuel-lean mixture at the flame base is the main source of stabilization of the lifted jet flame. A chemical flux analysis shows the occurrence of near-isothermal chemical chain branching preceding thermal runaway upstream of the stabilization point, indicative of hydrogen auto-ignition in the second limit. The Damköhler number and key intermediate-species behaviour near the leading edge of the lifted flame also verify that auto-ignition occurs at the flame base. At the lifted-flame base, it is found that heat release occurs predominantly through ignition in which the gradients of reactants are opposed. Downstream of the flame base, both rich-premixed and non-premixed flames develop and coexist with auto-ignition. In addition to auto-ignition, Lagrangian tracking of the flame base reveals the passage of large-scale flow structures and their correlation with the fluctuations of the flame base. In particular, the relative position of the flame base and the coherent flow structure induces a cyclic motion of the flame base in the transverse and axial directions about a mean lift-off height. This is confirmed by Lagrangian tracking of key scalars, heat release rate and velocity at the stabilization point.

Mechanics↗

Boundary Conditions for Diffusion-Mediated Processes within Linear Nanopores: Exact Treatment of Coupling to an Equilibrated External Fluid

In this paper, we consider a variety of diffusion-mediated processes occurring within linear nanopores, but which involve coupling to an equilibrated external fluid through adsorption and desorption. By determining adsorption and desorption rates through a set of tailored simulations, and by exploiting a spatial Markov property of the models, we develop a formulation for performing efficient pore-only simulations of these processes. Coupling to the external fluid is described exactly through appropriate nontrivial boundary conditions at the pore openings. This formalism is applied to analyze the following: (i) tracer counter permeation (TCP) where different labeled particles adsorb into opposite ends of the pore and establish a nonequilibrium steady state; (ii) tracer exchange (TE) with exchange of differently labeled particles within and outside the pore; (iii) catalytic conversion reactions where a reactant in the external fluid adsorbs into the pore and converts to a product which may desorb. The TCP analysis also generates a position-dependent generalized tracer diffusion coefficient, the form of which controls behavior in the TE and catalytic conversion processes. We focus on the regime of single-file diffusion within the pore which produces the strongest correlations and largest deviations from mean-field type behavior. Finally, behavior is quantified precisely via kinetic Monte Carlo simulations but is also captured with appropriate analytic treatments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The design and application of an in-laboratory diffraction-enhanced x-ray imaging instrument

We describe the design and application of a new in-laboratory diffraction-enhanced x-ray imaging (DEXI) instrument that uses a nonsynchrotron, conventional x-ray source to image the internal structure of an object. In the work presented here, a human cadaveric thumb is used as a test-sample to demonstrate the imaging capability of our instrument. A 22 keV monochromatic x-ray beam is prepared using a mismatched, two-crystal monochromator; a silicon analyzer crystal is placed in a parallel crystal geometry with the monochromator allowing both diffraction-enhanced imaging and multiple-imaging radiography to be performed. The DEXI instrument was found to have an experimentally determined spatial resolution of 160{+-}7 {mu}m in the horizontal direction and 153{+-}7 {mu}m in the vertical direction. As applied to biomedical imaging, the DEXI instrument can detect soft tissues, such as tendons and other connective tissues, that are normally difficult or impossible to image via conventional x-ray techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of charmonium-nucleon interaction in lattice QCD

We report preliminary results for charmonium-nucleon potential V{sub cc}-bar{sub N}(r) from quenched lattice QCD, which is calculated from the equal-time Bethe-Salpeter amplitude through the effective Schroedinger equation. Our simulations are performed at a lattice cutoff of 1/a = 2.0 GeV in a spatial volume of (3 fm){sup 3} with the nonperturbatively O(a) improved Wilson action for the light quarks and a relativistic heavy quark action for the charm quark. We have found that the potential V{sub cc}-bar{sub N}(r) is weakly attractive at short distance and exponentially screened at long distance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Direct observation of charge transfer region at interfaces in graphene devices

Nanoscale spectromicroscopic characterizing technique is indispensable for realization of future high-speed graphene transistors. Highly spatially resolved soft X-ray photoelectron microscopy measurements have been performed using our '3D nano-ESCA' (three-dimensional nanoscale electron spectroscopy for chemical analysis) equipment in order to investigate the local electronic states at interfaces in a graphene device structure. We have succeeded in detecting a charge transfer region at the graphene/metal-electrode interface, which extends over {approx}500 nm with the energy difference of 60 meV. Moreover, a nondestructive depth profiling reveals the chemical properties of the graphene/SiO{sub 2}-substrate interface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Non parametric denoising methods based on wavelets: Application to electron microscopy images in low exposure time

The 3D reconstruction of the Cryo-Transmission Electron Microscopy (Cryo-TEM) and Energy Filtering TEM images (EFTEM) hampered by the noisy nature of these images, so that their alignment becomes so difficult. This noise refers to the collision between the frozen hydrated biological samples and the electrons beam, where the specimen is exposed to the radiation with a high exposure time. This sensitivity to the electrons beam led specialists to obtain the specimen projection images at very low exposure time, which resulting the emergence of a new problem, an extremely low signal-to-noise ratio (SNR). This paper investigates the problem of TEM images denoising when they are acquired at very low exposure time. So, our main objective is to enhance the quality of TEM images to improve the alignment process which will in turn improve the three dimensional tomography reconstructions. We have done multiple tests on special TEM images acquired at different exposure time 0.5s, 0.2s, 0.1s and 1s (i.e. with different values of SNR)) and equipped by Golding beads for helping us in the assessment step. We herein, propose a structure to combine multiple noisy copies of the TEM images. The structure is based on four different denoising methods, to combine the multiple noisy TEM images copies. Namely, the four different methods are Soft, the Hard as Wavelet-Thresholding methods, Bilateral Filter as a non-linear technique able to maintain the edges neatly, and the Bayesian approach in the wavelet domain, in which context modeling is used to estimate the parameter for each coefficient. To ensure getting a high signal-to-noise ratio, we have guaranteed that we are using the appropriate wavelet family at the appropriate level. So we have chosen âĂIJsym8âĂİ wavelet at level 3 as the most appropriate parameter. Whereas, for the bilateral filtering many tests are done in order to determine the proper filter parameters represented by the size of the filter, the range parameter and the spatial parameter respectively. The experiments reported in this paper demonstrate the performance of the Bilateral Filtering and the Bayesian approaches in terms of improving the SNRout and the image quality. Taken together, these results suggest that the Bayesian process has a potential to outperform all the used methods, where in the multiple noisy copies structure it gave us the best SNRout without change of the golden beads diameter. The Bayesian approach yielded enhanced average image without needing a huge amount of copies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Nanomechanical and topographical imaging of living cells by atomic force microscopy with colloidal probes

Atomic Force Microscopy (AFM) has a great potential as a tool to characterize mechanical and morphological properties of living cells; these properties have been shown to correlate with cells’ fate and patho-physiological state in view of the development of novel early-diagnostic strategies. Although several reports have described experimental and technical approaches for the characterization of cellular elasticity by means of AFM, a robust and commonly accepted methodology is still lacking. Here, we show that micrometric spherical probes (also known as colloidal probes) are well suited for performing a combined topographic and mechanical analysis of living cells, with spatial resolution suitable for a complete and accurate mapping of cell morphological and elastic properties, and superior reliability and accuracy in the mechanical measurements with respect to conventional and widely used sharp AFM tips. We address a number of issues concerning the nanomechanical analysis, including the applicability of contact mechanical models and the impact of a constrained contact geometry on the measured Young’s modulus (the finite-thickness effect). We have tested our protocol by imaging living PC12 and MDA-MB-231 cells, in order to demonstrate the importance of the correction of the finite-thickness effect and the change in Young’s modulus induced by the action of a cytoskeleton-targeting drug.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wavelength-independent constant period spin-echo modulated small angle neutron scattering

Spin-Echo Modulated Small Angle Neutron Scattering (SEMSANS) in Time-of-Flight (ToF) mode has been shown to be a promising technique for measuring (very) small angle neutron scattering (SANS) signals and performing quantitative Dark-Field Imaging (DFI), i.e., SANS with 2D spatial resolution. However, the wavelength dependence of the modulation period in the ToF spin-echo mode has so far limited the useful modulation periods to those resolvable with the limited spatial resolution of the detectors available. Here we present our results of an approach to keep the period of the induced modulation constant for the wavelengths utilised in ToF. This is achieved by ramping the magnetic fields in the coils responsible for creating the spatially modulated beam in synchronisation with the neutron pulse, thus keeping the modulation period constant for all wavelengths. Such a setup enables the decoupling of the spatial detector resolution from the resolution of the modulation period by the use of slits or gratings in analogy to the approach in grating-based neutron DFI.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super-resolution surface slope metrology of x-ray mirrors

We present experimental, analytical, and numerical methods developed for reconstruction (deconvolution) of one-dimensional (1D) surface slope profiles over the spatial frequency range where the raw data are significantly perturbed due to the limited resolution of the measurement instrument. We characterize the spatial resolution properties of a profiler with the instrument's transfer function (ITF). To precisely measure the ITF, we apply a recently developed method utilizing test surfaces with 1D linear chirped height profiles of constant slope amplitude. Based on the results of the ITF calibration, we determine parameters of an analytical model for the ITF that is used in the original reconstruction software. Here, we treat surface slope metrology data obtained with the Optical Surface Measuring System (OSMS), using as a sensor an electronic autocollimator (AC) ELCOMAT-3000. The spatial resolution of the OSMS is limited by the size of the AC light-beam-collimating aperture. For the purposes of this investigation, the OSMS is equipped with a circular aperture with a diameter of 2.5 mm. This is a typical arrangement of most AC-based slope profilers developed for surface slope metrology of state-of-the-art x-ray mirrors. Using the example of surface slope metrology of two state-of-the-art elliptically shaped x-ray focusing mirrors, we demonstrate that the developed data reconstruction procedure allows us to significantly improve the accuracy of surface slope metrology with the OSMS over the spatial wavelength range from ~1.6 mm to 7 mm. Thus, the amplitude of the quasi-periodic error characteristic of the deterministic polishing process used appears to be higher by a factor of~2 than is apparent from the rough metrology data. Underestimation of the surface slope errors in this spatial wavelength range can lead to serious errors in the expected performance of x-ray mirrors in synchrotron beamlines, especially at modern light sources utilizing coherent x rays, where the perturbations can lead to increased speckle-like intensity variation.

47 OTHER INSTRUMENTATION↗