Search NASA⌕ Search

SEARCH · Search NASA

Results for “study protocol”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

An On-Line Technology Information System (OTIS) for Advanced Life Support

An On-line Technology Information System (OTIS) is currently being developed for the Advanced Life Support (ALS) Program. This paper describes the preliminary development of OTIS, which is a system designed to provide centralized collection and organization of technology information. The lack of thorough, reliable and easily understood technology information is a major obstacle in effective assessment of technology development progress, trade studies, metric calculations, and technology selection for integrated testing. OTIS will provide a formalized, well-organized protocol to communicate thorough, accurate, current and relevant technology information between the hands-on technology developer and the ALS Community. The need for this type of information transfer system within the Solid Waste Management (SWM) element was recently identified and addressed. A SWM Technology Information Form (TIF) was developed specifically for collecting detailed technology information in the area of SWM. In the TIF, information is requested from SWM technology developers, based upon the Technology Readiness Level (TRL). Basic information is requested for low-TRL technologies, and more detailed information is requested as the TRL of the technology increases. A comparable form is also being developed for the wastewater processing element. In the future, similar forms will also be developed for the ALS elements of air revitalization, food processing, biomass production and thermal control. These ALS element-specific forms will be implemented in OTIS via a web-accessible interface,with the data stored in an object-oriented relational database (created in MySQLTM) located on a secure server at NASA Ames Research Center. With OTIS, ALS element leads and managers will be able to carry out informed research and development investment, thereby promoting technology through the TRL scale. OTIS will also allow analysts to make accurate evaluations of technology options. Additionally, the range and specificity of information solicited will help educate technology developers of programmatic needs.

Levri, Julie A.↗

Isokinetic Strength and Endurance Tests used Pre- and Post-Spaceflight: Test-Retest Reliability

To assess changes in muscular strength and endurance after microgravity exposure, NASA measures isokinetic strength and endurance across multiple sessions before and after long-duration space flight. Accurate interpretation of pre- and post-flight measures depends upon the reliability of each measure. The purpose of this study was to evaluate the test-retest reliability of the NASA International Space Station (ISS) isokinetic protocol. Twenty-four healthy subjects (12 M/12 F, 32.0 +/- 5.6 years) volunteered to participate. Isokinetic knee, ankle, and trunk flexion and extension strength as well as endurance of the knee flexors and extensors were measured using a Cybex NORM isokinetic dynamometer. The first weekly session was considered a familiarization session. Data were collected and analyzed for weeks 2-4. Repeated measures analysis of variance (alpha=0.05) was used to identify weekly differences in isokinetic measures. Test-retest reliability was evaluated by intraclass correlation coefficients (ICC) (3,1). No significant differences were found between weeks in any of the strength measures and the reliability of the strength measures were all considered excellent (ICC greater than 0.9), except for concentric ankle dorsi-flexion (ICC=0.67). Although a significant difference was noted in weekly endurance measures of knee extension (p less than 0.01), the reliability of endurance measure by week were considered excellent for knee flexion (ICC=0.97) and knee extension (ICC=0.96). Except for concentric ankle dorsi-flexion, the isokinetic strength and endurance measures are highly reliable when following the NASA ISS protocol. This protocol should allow accurate interpretation isokinetic data even with a small number of crew members.

Laughlin, Mitzi S.↗

On-Orbit Prospective Echocardiography on International Space Station

A number of echocardiographic research projects and experiments have been flown on almost every space vehicle since 1970, but validation of standard methods and the determination of Space Normal cardiac function has not been reported to date. Advanced Diagnostics in Microgravity (ADUM) -remote guided echocardiographic technique provides a novel and effective approach to on-board assessment of cardiac physiology and structure using a just-in-time training algorithm and real-time remote guidance aboard the International Space Station (ISS). The validation of remotely guided echocardiographic techniques provides the procedures and protocols to perform scientific and clinical echocardiography on the ISS and the Moon. The objectives of this study were: 1.To confirm the ability of non-physician astronaut/cosmonaut crewmembers to perform clinically relevant remotely guided echocardiography using the Human Research Facility on board the ISS. 2.To compare the preflight, postflight and in-flight echocardiographic parameters commonly used in clinical medicine.

Hamilton, Douglas R.↗

Molecular Technique to Reduce PCR Bias for Deeper Understanding of Microbial Diversity

Current planetary protection policies require that spacecraft targeted to sensitive solar system bodies be assembled and readied for launch in controlled cleanroom environments. A better understanding of the distribution and frequency at which high-risk contaminant microbes are encountered on spacecraft surfaces would significantly aid in assessing the threat of forward contamination. However, despite a growing understanding of the diverse microbial populations present in cleanrooms, less abundant microbial populations are probably not adequately taken into account due to technological limitations. This novel approach encompasses a wide spectrum of microbial species and will represent the true picture of spacecraft cleanroom-associated microbial diversity. All of the current microbial diversity assessment techniques are based on an initial PCR amplification step. However, a number of factors are known to bias PCR amplification and jeopardize the true representation of bacterial diversity. PCR amplification of a minor template appears to be suppressed by the amplification of a more abundant template. It is widely acknowledged among environmental molecular microbiologists that genetic biosignatures identified from an environment only represent the most dominant populations. The technological bottleneck overlooks the presence of the less abundant minority population and may underestimate their role in the ecosystem maintenance. DNA intercalating agents such as propidium monoazide (PMA) covalently bind with DNA molecules upon photolysis using visible light, and make it unavailable for DNA polymerase enzyme during polymerase chain reaction (PCR). Environmental DNA samples will be treated with suboptimum PMA concentration, enough to intercalate with 90 99% of the total DNA. The probability of PMA binding with DNA from abundant bacterial species will be much higher than binding with DNA from less abundant species. This will increase the relative DNA concentration of previously "shadowed" less abundant species available for PCR amplification. These PCR products obtained with and without PMA treatment will then be subjected to downstream diversity analyses such as sequencing and DNA microarray. It is expected that PMA-coupled PCR will amplify the "minority population" and help in understanding microbial diversity spectrum of an environmental sample at a much deeper level. This new protocol aims to overcome the major potential biases faced when analyzing microbial 16S rRNA gene diversity. This study will lead to a technological advancement and a commercial product that will aid microbial ecologists in understanding microbial diversity from various environmental niches. Implementation of this technique may lead to discoveries of novel microbes and their functions in sustenance of the ecosystem.

Vaishampayan, Parag A.↗

A planning comparison of 7 irradiation options allowed in RTOG 1005 for early-stage breast cancer

This study compared the 7 treatment plan options in achieving the dose-volume criteria required by the Radiation Therapy Oncology Group (RTOG) 1005 protocol. Dosimetry plans were generated for 15 representative patients with early-stage breast cancer (ESBC) based on the protocol-required dose-volume criteria for each of the following 7 treatment options: 3D conformal radiotherapy (3DCRT), whole-breast irradiation (WBI) plus 3DCRT lumpectomy boost, 3DCRT WBI plus electron boost, 3DCRT WBI plus intensity-modulated radiation therapy (IMRT) boost, IMRT WBI plus 3DCRT boost, IMRT WBI plus electron boost, IMRT WBI plus IMRT boost, and simultaneous integrated boost (SIB) with IMRT. A variety of dose-volume parameters, including target dose conformity and uniformity and normal tissue sparing, were compared for these plans. For the patients studied, all plans met the required acceptable dose-volume criteria, with most of them meeting the ideal criteria. When averaged over patients, most dose-volume goals for all plan options can be achieved with a positive gap of at least a few tenths of standard deviations. The plans for all 7 options are generally comparable. The dose-volume goals required by the protocol can in general be easily achieved. IMRT WBI provides better whole-breast dose uniformity than 3DCRT WBI does, but it causes no significant difference for the dose conformity. All plan options are comparable for lumpectomy dose uniformity and conformity. Patient anatomy is always an important factor when whole-breast dose uniformity and conformity and lumpectomy dose conformity are considered.

61 RADIATION PROTECTION AND DOSIMETRY↗

Test Results and Comparison of Triaxial Strength Testing of Waste Isolation Pilot Plant Clean Salt

This memorandum documents laboratory thermomechanical triaxial strength testing of Waste Isolation Pilot Plant (WIPP) clean salt. The limited study completed independent, adjunct laboratory tests in the United States to assist in validating similar testing results being provided by the German facilities. The testing protocol consisted of completing confined triaxial, constant strain rate strength tests of intact WIPP clean salt at temperatures of 25°C and 100°C and at multiple confining pressures. The stratigraphy at WIPP also includes salt that has been labeled “argillaceous.” The much larger test matrix conducted in Germany included both the so-called clean and argillaceous salts. When combined, the total database of laboratory results will be used to develop input parameters for models, assess adequacy of existing models, and predict material behavior. These laboratory studies are also consistent with the goals of the international salt repository research program. The goal of this study was to complete a subset of a test matrix on clean salt from the WIPP undertaken by German research groups. The work was performed at RESPEC in Rapid City, South Dakota. A rigorous Quality Assurance protocol was applied, such that corroboration provides the potential of qualifying all of the test data gathered by German research groups.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Relative role of motion and PSF compensation in whole-body oncologic PET-MR imaging

Purpose: Respiratory motion and partial-volume effects are the two main sources of image degradation in whole-body PET imaging. Simultaneous PET-MR allows measurement of respiratory motion using MRI while collecting PET events. Improved PET images may be obtained by modeling respiratory motion and point spread function (PSF) within the PET iterative reconstruction process. In this study, the authors assessed the relative impact of PSF modeling and MR-based respiratory motion correction in phantoms and patient studies using a whole-body PET-MR scanner. Methods: An asymmetric exponential PSF model accounting for radially varying and axial detector blurring effects was obtained from point source acquisitions performed in the PET-MR scanner. A dedicated MRI acquisition protocol using single-slice steady state free-precession MR acquisitions interleaved with pencil-beam navigator echoes was developed to track respiratory motion during PET-MR studies. An iterative ordinary Poisson fully 3D OSEM PET reconstruction algorithm modeling all the physical effects of the acquisition (attenuation, scatters, random events, detectors efficiencies, PSF), as well as MR-based nonrigid respiratory deformations of tissues (in both emission and attenuation maps) was developed. Phantom and{sup 18}F-FDG PET-MR patient studies were performed to evaluate the proposed quantitative PET-MR methods. Results: The phantom experiment results showed that PSF modeling significantly improved contrast recovery while limiting noise propagation in the reconstruction process. In patients with soft-tissue static lesions, PSF modeling improved lesion contrast by 19.7%–109%, enhancing the detectability and assessment of small tumor foci. In a patient study with small moving hepatic lesions, the proposed reconstruction technique improved lesion contrast by 54.4%–98.1% and reduced apparent lesion size by 21.8%–34.2%. Improvements were particularly important for the smallest lesion undergoing large motion at the lung-liver interface. Heterogeneous tumor structures delineation was substantially improved. Enhancements offered by PSF modeling were more important when correcting for motion at the same time. Conclusions: The results suggest that the proposed quantitative PET-MR methods can significantly enhance the performance of tumor diagnosis and staging as compared to conventional methods. This approach may enable utilization of the full potential of the scanner in oncologic studies of both the lower abdomen, with moving lesions, as well as other parts of the body unaffected by motion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT

Background: SPECT myocardial perfusion imaging (MPI) is a clinical mainstay that is typically performed with static imaging protocols and visually or semi-quantitatively assessed for perfusion defects based upon the relative intensity of myocardial regions. Dynamic cardiac SPECT presents a new imaging technique based on time-varying information of radiotracer distribution, which permits the evaluation of regional myocardial blood flow (MBF) and coronary flow reserve (CFR). In this work, a preliminary feasibility study was conducted in a small patient sample designed to implement a unique combined static-dynamic single-dose one-day visit imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT for improving the diagnosis of coronary artery disease (CAD). Methods: Fifteen patients (11 males, four females, mean age 71 ± 9 years) were enrolled for a combined dynamic and static SPECT (Infinia Hawkeye 4, GE Healthcare) imaging protocol with a single dose of {sup 99m}Tc-tetrofosmin administered at rest and a single dose administered at stress in a one-day visit. Out of 15 patients, eleven had selective coronary angiography (SCA), 8 within 6 months and the rest within 24 months of SPECT imaging, without intervening symptoms or interventions. The extent and severity of perfusion defects in each myocardial region was graded visually. Dynamically acquired data were also used to estimate the MBF and CFR. Both visually graded images and estimated CFR were tested against SCA as a reference to evaluate the validity of the methods. Results: Overall, conventional static SPECT was normal in ten patients and abnormal in five patients, dynamic SPECT was normal in 12 patients and abnormal in three patients, and CFR from dynamic SPECT was normal in nine patients and abnormal in six patients. Among those 11 patients with SCA, conventional SPECT was normal in 5, 3 with documented CAD on SCA with an overall accuracy of 64%, sensitivity of 40% and specificity of 83%. Dynamic SPECT image analysis also produced a similar accuracy, sensitivity, and specificity. CFR was normal in 6, each with CAD on SCA with an overall accuracy of 91%, sensitivity of 80%, and specificity of 100%. The mean CFR was significantly lower for SCA detected abnormal than for normal patients (3.86±1.06 vs 1.94±0. 0.67, P < 0.001). Conclusions: The visually assessed image findings in static and dynamic SPECT are subjective, and may not reflect direct physiologic measures of coronary lesion based on SCA. The CFR measured with dynamic SPECT is fully objective, with better sensitivity and specificity, available only with the data generated from the dynamic SPECT method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Theoretical modeling of hepatitis C acute infection in liver-humanized mice support pre-clinical assessment of candidate viruses for controlled-human-infection studies

Designing and carrying out a controlled human infection (CHI) model for hepatitis C virus (HCV) is critical for vaccine development. However, key considerations for a CHI model protocol include understanding of the earliest viral-host kinetic events during the acute phase and susceptibility of the viral isolate under consideration for use in the CHI model to antiviral treatment before any infections in human volunteers can take place. Humanized mouse models lack adaptive immune responses but provide a unique opportunity to obtain quantitative understanding of early HCV kinetics and develop mathematical models to further understand viral and innate immune response dynamics during acute HCV infection. We show that the models reproduce the measured HCV kinetics in humanized mice, which are consistent with early acute HCV-host dynamics in immunocompetent chimpanzees. Our findings suggest that humanized mice are well-suited to support development of a CHI model. In-silico and in-vivo modeling estimates provide a starting point to characterize candidate viruses for testing in CHI model studies.

Agent-based modeling↗

MO-B-207B-00: Harmonization & Robustness in Radiomics

Feature extraction for radiomics studies typically comprises the following stages: Imaging, segmentation, image processing, and feature extraction. Each of these stages has associated uncertainties that can affect the quality of a radiomics model created using the resulting image features. For example, the imaging device manufacturer and model have been shown to impact the values of image features, as have pixel size and imaging protocol parameters. Image processing, such as low-pass filtering to reduce noise, also changes calculated image features and should be designed to optimize the information content of the resulting features. The details of certain feature algorithms, such as co-occurrence matrix bin sizes, are also important, and should be optimized for specific radiomics tasks. The volume of the region of interest should be considered as image features can be related to volume and can give unanticipated results when the volumes are too small. In this session we will describe approaches to quantify the variabilities in radiomics studies, including the most recent results quantifying these variabilities for CT, MRI and PET imaging. We will discuss methods to optimize image processing and feature extraction in order to maximize the information content of the image features. Finally, we will describe work to harmonize imaging protocols and feature calculations to help minimize uncertainties in radiomics studies. Learning Objectives: At the end of this session, participants will be able to: Identify the sources of uncertainty in radiomics studies (CT, PET, and MRI imaging) Describe methods for quantifying the magnitude of uncertainties Describe approaches for mitigating the effects of the uncertainties on radiomics models Funding from NIH, CPRIT, Varian, Elekta; L. Court, NCI, CPRIT, Varian, Elekta.

60 APPLIED LIFE SCIENCES↗

MO-B-207B-01: Harmonization & Robustness in Radiomics

Feature extraction for radiomics studies typically comprises the following stages: Imaging, segmentation, image processing, and feature extraction. Each of these stages has associated uncertainties that can affect the quality of a radiomics model created using the resulting image features. For example, the imaging device manufacturer and model have been shown to impact the values of image features, as have pixel size and imaging protocol parameters. Image processing, such as low-pass filtering to reduce noise, also changes calculated image features and should be designed to optimize the information content of the resulting features. The details of certain feature algorithms, such as co-occurrence matrix bin sizes, are also important, and should be optimized for specific radiomics tasks. The volume of the region of interest should be considered as image features can be related to volume and can give unanticipated results when the volumes are too small. In this session we will describe approaches to quantify the variabilities in radiomics studies, including the most recent results quantifying these variabilities for CT, MRI and PET imaging. We will discuss methods to optimize image processing and feature extraction in order to maximize the information content of the image features. Finally, we will describe work to harmonize imaging protocols and feature calculations to help minimize uncertainties in radiomics studies. Learning Objectives: At the end of this session, participants will be able to: Identify the sources of uncertainty in radiomics studies (CT, PET, and MRI imaging) Describe methods for quantifying the magnitude of uncertainties Describe approaches for mitigating the effects of the uncertainties on radiomics models Funding from NIH, CPRIT, Varian, Elekta; L. Court, NCI, CPRIT, Varian, Elekta.

60 APPLIED LIFE SCIENCES↗

High-efficiency, high-fidelity charge initialization of shallow nitrogen-vacancy centers in diamond

Nitrogen-vacancy (N-𝑉) centers in diamond exhibit long spin-coherence times, optical initialization, and optical-spin readout under ambient conditions, making them excellent quantum sensors. However, the conventional scheme for charge-state initialization based on off-resonant green excitation results in significant state-preparation errors, typically around 30%. One method for improving charge-state initialization fidelity is to use multicolor excitation, which has been demonstrated to achieve a near-unity preparation fidelity for bulk N-𝑉 centers by using a few milliseconds of near-infrared (NIR) (5-mW) and green (10-μ⁢W) excitation. The translation of such schemes to N-𝑉 centers near the diamond surface with higher-efficiency optical pumping would enable new applications in nanoscale sensing. Here, we demonstrate a protocol for efficient charge initialization of shallow N-𝑉 centers between 5 nm and 15 nm from the diamond surface. By carefully studying the charge dynamics of shallow N-𝑉 centers, we identify a region of parameter space that allows for near-unity (95%) charge initialization within 300 μ⁢s of NIR (905-nm, 1-mW) and green (520-nm, 10-μ⁢W) excitation. The time to 90% charge initialization can be as fast as 10 μ⁢s for 4 mW of NIR and 39 μ⁢W of green illumination. This fast, efficient charge initialization protocol will especially benefit nanoscale sensing applications in which state-preparation errors currently prohibit scaling, such as measuring higher-order multipoint correlators.

infrared techniques↗

Diagnosing and Destroying Non-Markovian Noise

Nearly every protocol used to analyze the performance of quantum information processors is based on an assumption that the errors experienced by the device during logical operations are constant in time and are insensitive to external contexts. This assumption is pervasive, rarely stated, and almost always wrong. Quantum devices that do behave this way are termed "Markovian:' but nearly every system we have ever probed has displayed drift or crosstalk or memory effects they are all non-Markovian. Strong non-Markovianity introduces spurious effects in characterization protocols and violates assumptions of the fault-tolerance threshold theorems. This SAND report details a three year laboratory-directed research and development (LDRD) project entitled, "Diagnosing and Destroying non-Markovian Noise in Quantum Information Processors." This program was initiated to build tools to study non-Markovian dynamics and quantum systems and develop robust methodologies for eliminating it. The program achieved a number of notable successes, including the first statistically rigorous protocol for identifying and characterizing drift in quantum systems, a formalism for modeling memory effects in quantum devices, and the successful suppression of drift in a Sandia trapped-ion quantum processor.

97 MATHEMATICS AND COMPUTING↗

High-Quality T2-Weighted 4-Dimensional Magnetic Resonance Imaging for Radiation Therapy Applications

Purpose: The purpose of this study was to improve triggering efficiency of the prospective respiratory amplitude-triggered 4-dimensional magnetic resonance imaging (4DMRI) method and to develop a 4DMRI imaging protocol that could offer T2 weighting for better tumor visualization, good spatial coverage and spatial resolution, and respiratory motion sampling within a reasonable amount of time for radiation therapy applications. Methods and Materials: The respiratory state splitting (RSS) and multi-shot acquisition (MSA) methods were analytically compared and validated in a simulation study by using the respiratory signals from 10 healthy human subjects. The RSS method was more effective in improving triggering efficiency. It was implemented in prospective respiratory amplitude-triggered 4DMRI. 4DMRI image datasets were acquired from 5 healthy human subjects. Liver motion was estimated using the acquired 4DMRI image datasets. Results: The simulation study showed the RSS method was more effective for improving triggering efficiency than the MSA method. The average reductions in 4DMRI acquisition times were 36% and 10% for the RSS and MSA methods, respectively. The human subject study showed that T2-weighted 4DMRI with 10 respiratory states, 60 slices at a spatial resolution of 1.5 × 1.5 × 3.0 mm{sup 3} could be acquired in 9 to 18 minutes, depending on the individual's breath pattern. Based on the acquired 4DMRI image datasets, the ranges of peak-to-peak liver displacements among 5 human subjects were 9.0 to 12.9 mm, 2.5 to 3.9 mm, and 0.5 to 2.3 mm in superior-inferior, anterior-posterior, and left-right directions, respectively. Conclusions: We demonstrated that with the RSS method, it was feasible to acquire high-quality T2-weighted 4DMRI within a reasonable amount of time for radiation therapy applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Organ doses, effective doses, and risk indices in adult CT: Comparison of four types of reference phantoms across different examination protocols

Purpose: Radiation exposure from computed tomography (CT) to the public has increased the concern among radiation protection professionals. Being able to accurately assess the radiation dose patients receive during CT procedures is a crucial step in the management of CT dose. Currently, various computational anthropomorphic phantoms are used to assess radiation dose by different research groups. It is desirable to better understand how the dose results are affected by different choices of phantoms. In this study, the authors assessed the uncertainties in CT dose and risk estimation associated with different types of computational phantoms for a selected group of representative CT protocols. Methods: Routinely used CT examinations were categorized into ten body and three neurological examination categories. Organ doses, effective doses, risk indices, and conversion coefficients to effective dose and risk index (k and q factors, respectively) were estimated for these examinations for a clinical CT system (LightSpeed VCT, GE Healthcare). Four methods were used, each employing a different type of reference phantoms. The first and second methods employed a Monte Carlo program previously developed and validated in our laboratory. In the first method, the reference male and female extended cardiac-torso (XCAT) phantoms were used, which were initially created from the Visible Human data and later adjusted to match organ masses defined in ICRP publication 89. In the second method, the reference male and female phantoms described in ICRP publication 110 were used, which were initially developed from tomographic data of two patients and later modified to match ICRP 89 organ masses. The third method employed a commercial dosimetry spreadsheet (ImPACT group, London, England) with its own hermaphrodite stylized phantom. In the fourth method, another widely used dosimetry spreadsheet (CT-Expo, Medizinische Hochschule, Hannover, Germany) was employed together with its associated male and female stylized phantoms. Results: For fully irradiated organs, average coefficients of variation (COV) ranged from 0.07 to 0.22 across the four male phantoms and from 0.06 to 0.18 across the four female phantoms; for partially irradiated organs, average COV ranged from 0.13 to 0.30 across the four male phantoms and from 0.15 to 0.30 across the four female phantoms. Doses to the testes, breasts, and esophagus showed large variations between phantoms. COV for gender-averaged effective dose and k factor ranged from 0.03 to 0.23 and from 0.06 to 0.30, respectively. COV for male risk index and q factor ranged from 0.06 to 0.30 and from 0.05 to 0.36, respectively; COV for female risk index and q factor ranged from 0.06 to 0.49 and from 0.07 to 0.54, respectively. Conclusions: Despite closely matched organ mass, total body weight, and height, large differences in organ dose exist due to variation in organ location, spatial distribution, and dose approximation method. Dose differences for fully irradiated radiosensitive organs were much smaller than those for partially irradiated organs. Weighted dosimetry quantities including effective dose, male risk indices, k factors, and male q factors agreed well across phantoms. The female risk indices and q factors varied considerably across phantoms.

61 RADIATION PROTECTION AND DOSIMETRY↗

A progressive electrochemical sensor for food quality control: Reliable determination of theobromine in chocolate products using a miniaturized boron-doped diamond electrode

In the present paper, a miniaturized boron-doped diamond electrode (BDDE) is proposed as a progressive electrochemical sensor for simple, fast and reliable quantification of dimethylxanthine alkaloid, theobromine (TB). Using cyclic voltammetry, the studied xanthine provided one well-shaped, irreversible and diffusion-controlled oxidation peak at relatively high potentials (+1.2 V vs. Ag/AgCl/3 M KCl reference electrode) in the presence of 0.1 M H2SO4. After selection of suitable experimental conditions, the linear calibration curves for TB were obtained in the concentration range from 0.99 up to 54.5 μM with the sensitivity of 0.07 μA/μM providing both differential pulse (DPV) and square-wave voltammetric (SWV) techniques, respectively. The elaborated voltammetric protocol yielded low detection limits of 0.42 and 0.51 μM accompanied by adequate intra-day repeatability (relative standard deviation of 2.5 and 1.7%) using DPV and SWV procedure, respectively. The interference study revealed the reasonable selectivity when taking the target food samples into account. The practical applicability of the voltammetric protocol using a miniaturized BDDE was verified in the analysis of six commercially available brands of chocolate products with the determined mass percentages of TB ranging from 0.75 to 2.24% and from 0.69 to 2.15% using DPV and SWV procedure, respectively. The obtained results were also in a good agreement with those achieved by reference titration method with potentiometric indication. The progressive electrochemical sensor based on a miniaturized BDDE has appeared to be an attractive candidate for practical applications in food quality control. Besides, the proposed voltammetric protocol presents advantages when compared to others techniques (e.g. chromatography), concerning simplicity, cost, speed of analysis, waste generation (environmentally friendly) and samples pretreatment (only dilution in electrolyte solution prior to analysis). © 2018 Elsevier B.V.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of a Fluorescence-Activated Cell Sorting Method Coupled with Whole Genome Amplification To Analyze Minority and Trace Dehalococcoides Genomes in Microbial Communities

Dehalococcoides mccartyi are functionally important bacteria that catalyze the reductive dechlorination of chlorinated ethenes. However, these anaerobic bacteria are fastidious to isolate, making downstream genomic characterization challenging. In order to facilitate genomic analysis, a fluorescence-activated cell sorting (FACS) method was developed in this study to separate D. mccartyi cells from a microbial community, and the DNA of the isolated cells was processed by whole genome amplification (WGA) and hybridized onto a D. mccartyi microarray for comparative genomics against four sequenced strains. First, FACS was successfully applied to a D. mccartyi isolate as positive control, and then microarray results verified that WGA from 10 6 cells or &sim;1 ng of genomic DNA yielded high-quality coverage detecting nearly all genes across the genome. As expected, some inter- and intrasample variability in WGA was observed, but these biases were minimized by performing multiple parallel amplifications. Subsequent application of the FACS and WGA protocols to two enrichment cultures containing &sim;10% and &sim;1% D. mccartyi cells successfully enabled genomic analysis. As proof of concept, this study demonstrates that coupling FACS with WGA and microarrays is a promising tool to expedite genomic characterization of target strains in environmental communities where the relative concentrations are low.

59 BASIC BIOLOGICAL SCIENCES↗

Cell-level reliability testing procedures for CIGS photovoltaics

The reliability of photovoltaics is commonly studied at the module level. Many reliability problems originate from module attributes, such as metal interconnections to cells, junction boxes. However, significant work in reliability can also be done prior to module design. Testing for reliability earlier in the research cycle increases the probability of avoiding common module reliability problems before cell changes are implemented on a large scale. Cell-level reliability studies can thus lower the rates of module failures in the field and provide confidence to investors that new technologies will perform as advertised. This report summarizes how we investigated three reliability concerns in Cu(In,Ga)Se 2 (CIGS) photovoltaics at the cell level: metastability, shading-induced damage, and potential-induced degradation (PID). We find that examining these concerns required developing robust measurement protocols including the fabrication of novel testing structures. This information will allow readers to incorporate sound metrics for investigating reliability phenomena and aid their studies of cell and module reliability improvements.

14 SOLAR ENERGY↗