At least 1,081 records · Page 60

NEON AOP Survey of Upper East River CO Watersheds: LAZ Files, LiDAR Surface Elevation, Terrain Elevation, and Canopy Height Rasters

Lawrence Berkeley National Laboratory (LBNL) contracted the National Ecological Observatory Network Airborne Observation Platform (NEON AOP) to observe watersheds of interest surrounding Crested Butte, CO with remotely sensed data, including LiDAR. The flight box design encompassed the watersheds, surveying a total area of 334 km2 across 72 lines. The instrument used was an Optech Gemini, with a pulse density of 2-9 pulses m-2 across the study area (see final report document for detailed information (Goulden and Musinsky 2020). These LiDAR data are the primary data that were provided by NEON, and include both LiDAR source data and derived surface products. The source data are contained in 'crbu_laz.zip' and 'classified_point_cloud.zip. 'classified_point_cloud.zip' represents an additional processing level on 'crbu_laz.zip'. The derived products are 'dsm_mosaic_min_phase_me.tif', 'dtm_mosaic_min_phase_me.tif', and 'tch_mosaic_min_phase_me.tif'. These files are raster mosaics of a digital surface elevation model (DSM), digital terrain elevation model (DTM), and a canopy height model (CHM) at 1 m resolution with a height threshold of > 2 m, respectively, in geotiff (.tif) format. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. [UPDATE] On 06/26/2026 the files 'crbu_laz.zip' and 'classified_point_cloud.zip' were replaced with original output files from NEON to address zip file corruption and naming errors. No changes were made to the underlying data. (See Methods Step 2 for details).

2018 NEON and 2025 CHESS Campaigns↗

NPFTURBULENCE: Turbulent Parameters by airborne measurements

The original data were collected during the field campaign of “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence) over the Atmospheric Radiation Measurement (ARM) user facility's Southern Great Plains (SGP) atmospheric observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IR temperature and imagery, and aerosol number concentration and size distribution. The current data set presents a comprehensive collection of turbulent parameters in the atmospheric boundary layer or lower free troposphere based on airborne measurement throughout the field campaign. The primary instruments used to create the current data set were the Aircraft Integrated Meteorological Measurement System (AIMMS-30) and the fine-wire thermocouple probe. For user convenience, the current data set includes several parameters commonly used in turbulent research for normalization and/or scaling: atmospheric boundary-layer height, surface conditions, convective scales for temperature, and velocity, etc.

54 ENVIRONMENTAL SCIENCES↗

Comparison of fluid-fluid interfacial areas measured with X-ray microtomography and interfacial partitioning tracer tests for the same samples

Two different methods are currently used for measuring interfacial areas between immiscible fluids within 3-D porous media, high-resolution microtomographic imaging and interfacial partitioning tracer tests (IPTT). Both methods were used in this study to measure nonwetting/wetting interfacial areas for a natural sand. The microtomographic imaging was conducted on the same packed columns that were used for the IPTTs. This is in contrast to prior studies comparing the two methods, for which in all cases different samples were used for the two methods. In addition, the columns were imaged before and after the IPTTs to evaluate the potential impacts of the tracer solution on fluid configuration and attendant interfacial area. The interfacial areas measured using IPTT are ~5 times larger than the microtomographic-measured values, which is consistent with previous work. Analysis of the image data revealed no significant impact of the tracer solution on NAPL configuration or interfacial area. Furthermore, other potential sources of error were evaluated, and all were demonstrated to be insignificant. The disparity in measured interfacial areas between the two methods is attributed to the limitation of the microtomography method to characterize interfacial area associated with microscopic surface roughness due to resolution constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigation of Corrosion Behavior of Carbide Phase Strengthened Nickel‐Based Alloy in Molten Fluoride Salt

The corrosion behavior of a high creep strength carbide-phase strengthened Ni-based alloy in molten FLiNaK (LiF-NaF-KF: 46.5-11.5-42 mol%) salt in the temperature range of 700°C–750°C has been investigated as a part of the development of structural alloys for fluoride salt-based molten salt reactors (MSRs). The alloy composition was designed based on Hastelloy-N, but with the goal of improving creep strength. Cr depletion depth, a measure of corrosion, was observed to be single micrometers after several hundred hours of corrosion testing. Sequential corrosion testing involving testing of pre-tested samples in fresh salt coupled with SEM-EDS, scanning transmission electron microscopy (STEM) examinations and thermodynamic and kinetic modeling, suggest that the corrosion rate at the alloy-salt interface is governed by diffusion of elements from the alloy bulk to the surface. The carbide phases in the corrosion-tested sample microstructure were identified to be largely M 6 C-type Mo-rich carbides and MC-type mixed carbides. Atom probe tomography (APT) showed some partitioning of Cr and Ti to the carbide phase and showed the carbide phases to be stable at the salt-facing surface.

Gordon, Ryan [Univ. of Wisconsin, Madison, WI (Uni↗

Beam related response of in vivo diode detectors for external radiotherapy

In Vivo Dosimetry (IVD) is a set of methods used in cancer treatment clinics to determine the real dose of radiation absorbed by target volume in a patient’s body. IVD has been widely implemented in radiotherapy treatment centers and is now recommended part of Quality Assurance program by many International health and radiation organizations. Because of cost and lack of specialized personnel, IVD has not been practiced as yet, in Albanian radiotherapy clinics. At Hygeia Hospital Tirana, patients are irradiated with high energy photons generated by Elekta Synergy Accelerators. We have recently started experimenting with the purpose of establishing an IVD practice at this hospital. The first set of experiments was aimed at calibration of diodes that are going to be used for IVD. PMMA, phantoms by PTW were used to calibrate p – type Si, semiconductor diode dosimeters, made by PTW Freiburg for entrance dose. Response of the detectors is affected by energy of the beam, accumulated radiation dose, dose rate, temperature, angle against the beam axis, etc. Here we present the work done for calculating calibration factor and correction factors of source to surface distance, field size, and beam incidence for the entrance dose for both 6 MV photon beam and 18 MV photon beam. Dependence of dosimeter response was found to be more pronounced with source to surface distance as compared to other variables investigated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Steady magnetic-field generation via surface-plasma-wave excitation

The possibility of inducing a magnetic field via surface plasma-wave excitation is investigated with a simple nonrelativistic hydrodynamic model. A static magnetic field is predicted at the plasma surface, scaling with the square of the surface-wave field amplitude, and the influence of the electron plasma density is studied. In the case of resonant surface-wave excitation by laser this result can be applied to low intensities such that the electron quiver velocity in the field of the surface wave is less than its thermal velocity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods and apparatuses for preparing a surface to have catalytic activity

The invention provides methods and apparatuses that utilize mass spectrometry for preparation of a surface to have catalytic activity through molecular soft-landing of mass selected ions. Mass spectrometry is used to generate combinations of atoms in a particular geometrical arrangement, and ion soft-landing selects this molecular entity or combination of entities and gently deposits the entity or combination intact onto a surface.

47 OTHER INSTRUMENTATION↗

Carbon nanotube oscillator surface profiling device and method of use

The proposed device is based on a carbon nanotube oscillator consisting of a finite length outer stationary nanotube and a finite length inner oscillating nanotube. Its main function is to measure changes in the characteristics of the motion of the carbon nanotube oscillating near a sample surface, and profile the roughness of this surface. The device operates in a non-contact mode, thus it can be virtually non-wear and non-fatigued system. It is an alternative to the existing atomic force microscope (AFM) tips used to scan surfaces to determine their roughness.

47 OTHER INSTRUMENTATION↗

Electron tube

An electron tube of the present invention includes: a vacuum vessel including a face plate portion made of synthetic silica and having a surface on which a photoelectric surface is provided, a stem portion arranged facing the photoelectric surface and made of synthetic silica, and a side tube portion having one end connected to the face plate portion and the other end connected to the stem portion and made of synthetic silica; a projection portion arranged in the vacuum vessel, extending from the stem portion toward the photoelectric surface, and made of synthetic silica; and an electron detector arranged on the projection portion, for detecting electrons from the photoelectric surface, and made of silicon.

47 OTHER INSTRUMENTATION↗

Electronic interconnects and devices with topological surface states and methods for fabricating same

An interconnect is disclosed with enhanced immunity of electrical conductivity to defects. The interconnect includes a material with charge carriers having topological surface states. Also disclosed is a method for fabricating such interconnects. Also disclosed is an integrated circuit including such interconnects. Also disclosed is a gated electronic device including a material with charge carriers having topological surface states.

36 MATERIALS SCIENCE↗

Ultra-short wavelength x-ray system

A method and apparatus to generate a beam of coherent light including x-rays or XUV by colliding a high-intensity laser pulse with an electron beam that is accelerated by a synchronized laser pulse. Applications include x-ray and EUV lithography, protein structural analysis, plasma diagnostics, x-ray diffraction, crack analysis, non-destructive testing, surface science and ultrafast science.

47 OTHER INSTRUMENTATION↗

The potential for intensity interferometry with {gamma}-ray telescope arrays

Intensity interferometry exploits a quantum optical effect in order to measure objects with extremely small angular scales. The first experiment to use this technique was the Narrabri intensity interferometer, which was successfully used in the 1970s to measure 32 stellar diameters at optical wavelengths; some as small as 0.4 milli-arcseconds. The advantage of this technique, in comparison with Michelson interferometers, is that it requires only relatively crude, but large, light collectors equipped with fast (nanosecond) photon detectors. Ground-based {gamma}-ray telescope arrays have similar specifications, and a number of these observatories are now operating worldwide, with more extensive installations planned for the future. These future instruments (CTA, AGIS, completion 2015) with 30-90 telescopes will provide 400-4000 different baselines that range in length between 50 m and a kilometre. Intensity interferometry with such arrays of telescopes attains 50 {mu}-arcsecond resolution for a limiting m{sub v}{approx}8.5. Phase information can be extracted from the interferometric measurement with phase closure, allowing image reconstruction. This technique opens the possibility of a wide range of studies amongst others, probing the stellar surface activity and the dynamic AU scale circumstellar environment of stars in various crucial evolutionary stages. Here we focuse on the astrophysical potential of an intensity interferometer utilising planned new {gamma}-ray instrumentation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of Work Functions, Metallicity, Band Bending, Interfacial Dipoles by EUPS for Characterizing High-k/Metal Interfaces

EUPS (EUV excited photoelectron spectroscopy) is a novel photoelectron spectroscopy technique, in which a sample is excited with 4.86 nm (255 eV), 3-ns pulse EUV light emitted from a laser-produced plasma and the resulting electron spectrum is analyzed with a time-of-flight (TOF) analyzer. EUPS gives information of the topmost atoms because the escape depth of photo-electrons excited by 4.86 nm light is only 0.5 nm. EUPS can evaluate band-bending because the peak density of the excitation light on the sample is extremely high, so that bent electronic bands in semiconductors can be flattened. Secondary electron spectra, from which the vacuum level of the material surface can be determined, are obtained very quickly owing to the use of a TOF analyzer, The metal gate related issues are one of the most challenging topics facing CMOS technology. This paper demonstrates EUPS as a powerful method for characterizing high-k/metal interfaces by showing data from direct observations of interfacial dipoles.

36 MATERIALS SCIENCE↗

On the accuracy of stratospheric aerosol extinction derived from in situ size distribution measurements and surface area density derived from remote SAGE II and HALOE extinction measurements

In situ stratospheric aerosol measurements, from University of Wyoming optical particle counters (OPCs), are compared with Stratospheric Aerosol Gas Experiment (SAGE) II (versions 6.2 and 7.0) and Halogen Occultation Experiment (HALOE) satellite measurements to investigate differences between SAGE II/HALOE-measured extinction and derived surface area and OPC-derived extinction and surface area. Coincident OPC and SAGE II measurements are compared for a volcanic (1991-1996) and nonvolcanic (1997 2005) period. OPC calculated extinctions agree with SAGE II measurements, within instrumental uncertainty, during the volcanic period, but have been a factor of 2 low during the nonvolcanic period. Three systematic errors associated with the OPC measurements, anisokineticity, inlet particle evaporation, and counting efficiency, were investigated. An overestimation of the OPC counting efficiency is found to be the major source of systematic error. With this correction OPC calculated extinction increases by 15 30% (30 50%) for the volcanic (nonvolcanic) measurements. These changes significantly improve the comparison with SAGE II and HALOE extinctions in the nonvolcanic cases but slightly degrade the agreement in the volcanic period. These corrections have impacts on OPC-derived surface area density, exacerbating the poor agreement between OPC and SAGE II (version 6.2) surface areas. This disparity is reconciled with SAGE II version 7.0 surface areas. For both the volcanic and nonvolcanic cases these changes in OPC counting efficiency and in the operational SAGE II surface area algorithm leave the derived surface areas from both platforms in significantly better agreement and within the 40% precision of the OPC moment calculations.

54 ENVIRONMENTAL SCIENCES↗

A novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography

An experimental study about the anisotropic wetting behavior of a surface patterned with parallel grooves is presented as an application example of a novel technique for investigation of complete and partial anisotropic wetting on structured surface by X-ray microtomography. Shape of glycerin droplets on such surface is investigated by X-ray micro computed tomography (microCT) acting as a non-intrusive, full volume 3D microscope with micrometric spatial resolution. The reconstructed drop volumes enable to estimate the exact volumes of the drops, their base contours, and 3D static contact angles, based on true cross-sections of the drop-surface couple. Droplet base contours are compared to approximate geometrical contour shapes proposed in the literature. Contact angles along slices parallel and perpendicular to the grooves direction are compared with each other. The effect of the sessile drop volume on the wetting behavior is discussed. The proposed technique, which is applicable for any structured surface, enables the direct measure of Wenzel ratio based on the microCT scan in the wetted region usually inapproachable by any others. Comparisons with simplified models are presented and congruence of results with respect to the minimum resolution needed is evaluated and commented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

1D silicon refractive lenses for surface scattering with high energy x-rays

At the high energy X-ray beamline P07 at PETRA III, 1D focusing down to 4 micrometer vertical beam height while preserving a horizontal beam width of 0.5 mm was established by refractive lenses etched into a silicon wafer. A single wafer with 8 different lens structures can cover the full energy range between 50 and 120 keV. For surface diffraction on ultrathin films a factor of 4 in intensity can be achieved compared to the already established Al-compound refractive 2D-lenses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Note: Hollow cathode lamp with integral, high optical efficiency isolation valve: A modular vacuum ultraviolet source

The design and operating conditions of a hollow cathode discharge lamp for the generation of vacuum ultraviolet radiation, suitable for ultrahigh vacuum (UHV) application, are described in detail. The design is easily constructed, and modular, allowing it to be adapted to different experimental requirements. A thin isolation valve is built into one of the differential pumping stages, isolating the discharge section from the UHV section, both for vacuum safety and to allow lamp maintenance without venting the UHV chamber. The lamp has been used both for ultraviolet photoelectron spectroscopy of surfaces and as a “soft” photoionization source for gas-phase mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗