Search NASA⌕ Search

SEARCH · Search NASA

Results for “system parameters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,081 records · Page 60

Comment on 'Superluminal solitons in a {lambda}-type atomic system with two-folded levels'

We show that the analysis of the optical solitons in a resonant, lifetime-broadened {lambda}-type atomic system with two-folded lower levels, given recently by D. Han et al. [J. Opt. Soc. Am. B 24, 2244 (2007)], is incorrect. Although in the anomalous dispersion regime near resonance one may obtain a superluminal optical soliton, such a soliton suffers serious absorption and hence cannot propagate a significant distance. However, by choosing appropriate system parameters to work in the normal dispersion regime and hence inside the transparency windows of double dark resonance, an ultraslow optical soliton with very low light intensity can form and propagate stably for a fairly long distance.

74 ATOMIC AND MOLECULAR PHYSICS↗

DOE EV Data Collection - Facility Data

Facility data includes information on electricity consumption by larger-scale infrastructure, including buildings, solar arrays, and energy storage systems. Parameter definitions can be found in the data dictionary. If a connection between specific vehicle information and facility data exists, it will be available in the vehicle attributes table. Vehicle ID can be used as a key between vehicle data and vehicle attribute tables. Data is being uploaded quarterly through 2023 and subject to change until the conclusion of the project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Under-Sodium Viewing: A Review of Ultrasonic Imaging Technology for Liquid Metal Fast Reactors

This current report is a summary of information obtained in the "Information Capture" task of the U.S. DOE-funded "Under Sodium Viewing (USV) Project." The goal of the multi-year USV project is to design, build, and demonstrate a state-of-the-art prototype ultrasonic viewing system tailored for periodic reactor core in-service monitoring and maintenance inspections. The study seeks to optimize system parameters, improve performance, and re-establish this key technology area which will be required to support any new U.S. liquid-metal cooled fast reactors.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Novel Separation of Actinides

The separation of actinides and other elements of interest for nuclear forensics and threat reduction is currently performed using decades-old chemistries and ion-exchange columns. We propose to determine the technical feasibility of a novel method for separating actinide ions in solution. This method is based upon isotachophoresis (ITP), which has been applied in the purification of pharmaceuticals and other biochemical applications. This technique has the potential to separate inorganic ions more effectively than existing methods, which is key to analyzing very small samples. We will perform a quantitative assessment of the effectiveness of specific isotachophoretic approaches including predicting the physical and chemical properties, such as ion mobility, of inorganic ions under specific solvent conditions using a combination of ab initio calculations and semi-empirical methods. We expect to obtain a thorough understanding of the analytical systems parameters under which ITP is most effective for the separation of inorganic samples, including the influence of the double layer surrounding actinide ions, the Debye length for different ions and ion complexes, and Debye-Hueckel limits. Inorganic separations are key to nuclear forensics for countering terrorism and nuclear proliferation. If found to be feasible and potentially superior to currently used separation approaches, ITP could provide the conceptual basis for an improved means to separate samples of nuclear explosion debris for nuclear forensic analysis, in support of the Laboratory's missions in homeland and national security.

42 ENGINEERING↗

Analysis of Dose Consequences Arising from the Release of Spent Nuclear Fuel from Dry Storage Casks

The resulting dose consequences from releases of spent nuclear fuel (SNF) residing in a dry storage casks are examined parametrically. The dose consequences are characterized by developing dose versus distance curves using simplified bounding assumptions. The dispersion calculations are performed using the MELCOR Accident Consequence Code System (MACCS2) code. Constant weather and generic system parameters were chosen to ensure that the results in this report are comparable with each other and to determine the relative impact on dose of each variable. Actual analyses of site releases would need to accommodate local weather and geographic data. These calculations assume a range of fuel burnups, release fractions (RFs), three exposure scenarios (2 hrs and evacuate, 2 hrs and shelter, and 24 hrs exposure), two meteorological conditions (D-4 and F-2), and three release heights (ground level – 1 meter (m), 10 m, and 100 m). This information was developed to support a policy paper being developed by U.S. Nuclear Regulatory Commission (NRC) staff on an independent spent fuel storage installation (ISFSI) and monitored retrievable storage installation (MRS) security rulemaking.

Durbin, Samuel G.↗

Enhanced Micellar Catalysis LDRD.

The primary goals of the Enhanced Micellar Catalysis project were to gain an understanding of the micellar environment of DF-200, or similar liquid CBW surfactant-based decontaminants, as well as characterize the aerosolized DF-200 droplet distribution and droplet chemistry under baseline ITW rotary atomization conditions. Micellar characterization of limited surfactant solutions was performed externally through the collection and measurement of Small Angle X-Ray Scattering (SAXS) images and Cryo-Transmission Electron Microscopy (cryo-TEM) images. Micellar characterization was performed externally at the University of Minnesota s Characterization Facility Center, and at the Argonne National Laboratory Advanced Photon Source facility. A micellar diffusion study was conducted internally at Sandia to measure diffusion constants of surfactants over a concentration range, to estimate the effective micelle diameter, to determine the impact of individual components to the micellar environment in solution, and the impact of combined components to surfactant phase behavior. Aerosolized DF-200 sprays were characterized for particle size and distribution and limited chemical composition. Evaporation rates of aerosolized DF-200 sprays were estimated under a set of baseline ITW nozzle test system parameters.

Betty, Rita G.↗

Evaluation of RTV as a Moldable Matrix When Combined With Molecular Sieve and Organic Hydrogen Getter

This work was undertaken in an effort to develop a combined RTV 615/3Å molecular sieve/DEB molded component. A molded RTV 615/3Å molecular sieve component is currently in production, and an RTV 615/DEB component was produced in the past. However, all three materials have never before been combined in a single production part, and this is an opportunity to create a new component capable of being molded to shape, performing desiccation, and hydrogen gettering. This analysis looked at weapons system parameters and how they might influence part design. It also looked at material processing and how it related to mixing, activating a dessicant, and hydrogen uptake testing.

36 MATERIALS SCIENCE↗

Direct Measurement of Plutonium in Spent Fuel with X-ray Fluoresence

Currently, the only NDA technique that directly measures Pu in SNF involves XRF measurements. Measurements and simulations were used to demonstrate that with a properly - 15 - configured detector system, it is feasible to measure the Pu/U atom ratio at the surface of a fuel pin using measurements of the 103.7 keV K X-ray from Pu. Since the Pu/U atom ratio at the surface of the pin is directly related to the average Pu/U concentration for the pin, the technique might be applicable to measuring the Pu/U concentration in an LWR spent fuel pin. However, the technique requires knowledge of the fuel pin design and operating history to properly correlate surface Pu to average Pu for a pin. Fuel history information is available from operator declarations and can be verified by complementary measurements including gamma spectroscopy and passive gross neutron counts. While the count times of 4 to 12 hours used in these measurements were longer than would be acceptable in most applications, efforts are being made to improve counting time. These include the use of a segmented HPGe detector and reduction of Compton scattering background. These measurements are useful for individual fuel pins and provide a complementary, validating measurement for full assembly techniques. For future work, optimized detector systems and measurement approaches will be explored with the goal of measuring the Pu/U X-ray ratio with shorter count times. Measurements will be compared with the results of destructive analysis, which is to be completed this year, to provide a correlation between the measured Pu/U ratio and the total Pu/U ratio in the fuel. In addition, the sensitivity of this method to variations in system parameters will be studied to determine the expected accuracy of the technique.

Romano, Catherine E.↗

Carbon Dioxide, Hydrographic, and Chemical Data Obtained During the R/V Knorr Repeat Hydrography Cruise in the Atlantic Ocean: CLIVAR CO 2 Sections A20_2003 (22 September-20 October 2003) and A22_2003 (23 October-13 November, 2003)

This report presents methods, and analytical and quality control procedures for salinity, oxygen, nutrient, inorganic carbon, organic carbon, chlorofluorocarbon (CFC), and bomb carbon-14 system parameters performed during the A20_2003 and A22_2003 cruises, which took place between September 22 and November 13, 2003, aboard research vessel (R/V) Knorr under the auspices of the National Oceanic and Atmospheric Administration (NOAA) and National Science Foundation (NSF). The R/V Knorr departed Woods Hole, Massachusetts, on September 22 for the Repeat Section A20, and ended this line in Port of Spain, Trinidad, on October 20. The Repeat Section A22 started on October 23 in Port of Spain, Trinidad, and finished on November 13, 2003, in Woods Hole, Massachusetts. The research conducted was one of a series of repeat hydrography sections jointly funded by NOAA and NSF as part of the Climate Variability Program (CLIVAR)/CO2/repeat hydrography/tracer program. Samples were taken from 36 depths at 88 stations on section A20 and 82 stations on section A22. The data presented in this report include the analyses of water samples for total inorganic carbon (TCO 2 ), total alkalinity (TALK), dissolved organic carbon (DOC), CFC, carbon-14, hydrographic, and other chemical measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shadow Probability of Detection and False Alarm for Median-Filtered SAR Imagery

Median filtering reduces speckle in synthetic aperture radar (SAR) imagery while preserving edges, at the expense of coarsening the resolution, by replacing the center pixel of a sliding window by the median value. For shadow detection, this approach helps distinguish shadows from clutter more easily, while preserving shadow shape delineations. However, the nonlinear operation alters the shadow and clutter distributions and statistics, which must be taken into consideration when computing probability of detection and false alarm metrics. Depending on system parameters, median filtering can improve probability of detection and false alarm by orders of magnitude. Herein, we examine shadow probability of detection and false alarm in a homogeneous, ideal clutter background after median filter post-processing. Some comments on multi-look processing effects with and without median filtering are also made.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

City of Hoboken Energy Surety Analysis: Preliminary Design Summary

In 2012, Hurricane Sandy devastated much of the U.S. northeast coastal areas. Among those hardest hit was the small community of Hoboken, New Jersey, located on the banks of the Hudson River across from Manhattan. This report describes a city-wide electrical infrastructure design that uses microgrids and other infrastructure to ensure the city retains functionality should such an event occur in the future. The designs ensure that up to 55 critical buildings will retain power during blackout or flooded conditions and include analysis for microgrid architectures, performance parameters, system control, renewable energy integration, and financial opportunities (while grid connected). The results presented here are not binding and are subject to change based on input from the Hoboken stakeholders, the integrator selected to manage and implement the microgrid, or other subject matter experts during the detailed (final) phase of the design effort.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Scalable Analysis Methods and In Situ Infrastructure for Extreme Scale Knowledge Discovery

High performance computers have for many years been on a trajectory that gives them extraordinary compute power with the addition of more and more compute cores. At the same time, other system parameters such as the amount of memory per core and bandwidth to storage have remained constant or have barely increased. This creates an imbalance in the computer, giving it the ability to compute a lot of data that it cannot reasonably save out due to time and storage constraints. While technologies have been invented to mitigate this problem (burst buffers, etc.), software has been adapting to employ in situ libraries which perform data analysis and visualization on simulation data while it is still resident in memory. This avoids the need to ever have to pay the costs of writing many terabytes of data files. Instead, in situ enables the creation of more concentrated data products such as statistics, plots, and data extracts, which are all far smaller than the full-sized volume data. With the increasing popularity of in situ, multiple in situ infrastructures have been created, each with its own mechanism for integrating with a simulation. To make it easier to instrument a simulation with multiple in situ infrastructures and include custom analysis algorithms, this project created the SENSEI framework.

97 MATHEMATICS AND COMPUTING↗

Executive Summary: Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room

Under the United States Department of Energy Light Water Sustainability Program (LWRS), Idaho National Laboratory (INL) is collaborating with Palo Verde Generating Station (PVGS) to support human factors engineering efforts in the modernization of PVNGS’ radiological waste system (LRS) control room. The studies proposed and/or conducted by INL are designed to address the inconsistency between different human factors standards, guidance, and conventions. Guidance such as NUREG-0700 leave much of the information open to interpretation. INL will identify whether maintaining a design that is consistent with population stereotypes actually enhances performance, or whether there are alternative designs that yield performance that is better than the designs that maintain those stereotypes. The overall design concept for the LRS workstation includes system overview displays for the Evaporator system and the Boric Acid Concentrator system. A third display contains overview information for the rest of the LRS. The forth display contains alarm information. Each display will be presented on one of four monitors in the control room. The system overview displays contain embedded controls for valves and pumps, mini-trends, and micro-trends. The mini-trends present data for the controllers and contain alarm set point information as well as trending. All other relevant system parameters are shown on micro-trends. The semi-dull screen approach utilized present dynamic data in green, active components are white (gray when closed or off). The product stream flow paths are indicated by different colors. Alarm states are presented in saturated red and selected components are indicated by bright blue. In addition to the micro task study described below, the INL researchers also conducted an evaluation of the semi-dull screen approach as well as an ergonomic evaluation of the suggested upgrades in the local control room. A detailed report of all INL’s activities related to the modernization of the LRS conducted between October 2016 and September 2017 are found in these two reports; • INL-EXT-17-43226, Prototype Design, Analysis, and Results for a Liquid Radiological Waste Control Room, and • INL-EXT-17-43250, Evaluation of Control Room Interface Designs to Support Modernization in Nuclear Power Plants.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Thermal Test of 29 mm and 12 mm Targets

NorthStar medical isotopes are planning to produce important medical radioisotope molybdenum-99 (Mo-99) through photonuclear reaction on molybdenum-100 (Mo-100). In this approach, multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, we intend to use as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target),which sets challenging requirements for cooling. Together with scientists at Los Alamos National Laboratory, a team at Argonne National Laboratory has developed and demonstrated a cooling approach using pressurized helium, which allows for efficient heat removal. One of the challenges in this approach is the management of the heat load on the target window. The target window separates the high-pressure helium atmosphere inside the target from the vacuum in the beamline so it is constantly under stress from differential pressure. Also, the window is cooled only by the helium gas flow from one side, making the window design challenging. To validate calculation models, the team performed a series of tests at Argonne’s Low Energy Accelerator Facility (LEAF). This report describes additional tests for two target designs: a full-scale target 29 millimeters in diameter and a scaled-down version, 12 millimeters in diameter. We compared the results of the window temperature measurements and cooling system parameters obtained in the experiments with those predicted by analytical calculations and Computation Flow Dynamic (CFD) simulations. Results of the experiments and calculations are presented below.

07 ISOTOPE AND RADIATION SOURCES↗

Human-System Interface Design Review Guidelines

The U.S. Nuclear Regulatory Commission (NRC) staff reviews the human factors engineering (HFE) aspects of nuclear power plants in accordance with the Standard Review Plan (NUREG-0800, Standard Review Plan for the Review of Safety Analysis Reports for Nuclear Power Plants: LWR Edition). The Human Factors Engineering Program Review Model (NUREG-0711, Revision 3, issued November 2012) contains detailed design review procedures. As part of the review process, the interfaces between plant personnel and the plant's systems and components are evaluated for conformance with HFE guidelines. This document, Human-System Interface Design Review Guidelines (NUREG-0700, Revision 3), provides the guidelines necessary to perform this evaluation. The review guidelines address the physical and functional characteristics of human-system interfaces (HSIs). Because these guidelines only address the HFE aspects of design and not other related considerations, such as instrumentation and control and structural design, they are referred to as HFE guidelines. In addition to the review of actual HSIs, the NRC staff can use the NUREG-0700 guidelines to evaluate a design-specific HFE guidelines document or style guide. The HFE guidelines are organized into four basic parts, which are divided into sections. Part I contains guidelines for the basic HSI elements: information displays, user-interface interaction and management, and analog displays and controls. These elements are used as building blocks to develop HSI systems to serve specific functions. Part II contains the guidelines for reviewing the following HSI systems: alarm system, safety parameter display system, group-view display system, soft control system, computer-based procedure system, automation system, and communication system. Part III provides guidelines for the review of workstations and workplaces. Part IV provides guidelines for the review of HSI support (i.e., maintainability of digital systems and degraded HSI and instrumentation and control conditions).

42 ENGINEERING↗

Feasibility of the LAMMPS SPH Package for Simulating Bubble Motion in Vibrating Containers

The Smoothed Particle Hydrodynamics (SPH) package within LAMMPS is explored as a possible tool for simulating the motion of bubbles in a vibrating liquid-filled container. As an initial test case, the unphysical but computationally less intense situation of a two-dimensional single bubble rising in a quiescent liquid under the influence of gravity is considered herein. Although physically plausible behavior was obtained under certain conditions, this behavior depends strongly on the system parameters. Moreover, the large density ratio between the liquid and bubble requires extremely small timesteps, which make the simulations undesirably computationally expensive. Ultimately, it was determined that this method is not feasible for providing quantitatively accurate results for the desired application.

42 ENGINEERING↗

A Short-Term Solar Forecasting Platform Using a Physics-Based Smart Persistence Model and Data Imputation Method

Electrical energy plays vital role in our socio-economic activity and therefore ensuring the reliability of the electric grid, from the generation, transmission and distribution level is critical. In order to maintain the power system parameter viz., frequency, voltage, etc., optimally, balancing of generation and consumption is very much essential. However, solar energy is infirm power by nature this is due to cloud cover / other local phenomena. Hence, Photovoltaic (PV) power generation brings a significant challenge to the grid operator due to the variability of the solar energy. The complexity of this challenge in terms of planning and dispatch ability of PV resources, aggravates with the high penetration of solar energy into the electric grid. In this setting, reliable solar radiation forecasting models based on accurate and quality input data become essential. In order to develop a suitable model for predicting solar radiation, quality historical / real time measurement is also needed. Under this study NIWE and NREL jointly developed / tested short-term solar forecasting frameworks using a smart persistence and physics-based smart persistence models for intra-hour forecasting of solar radiation (PSPI) and benchmarked 9 different data imputation techniques in 15 Solar Radiation Resource Assessment (SRRA) stations, located at different parts of India. During any measurement campaign, due to various technical reasons, we may miss few observations. However, the missing observation often reduce the performance of any forecasting model. Therefore, suitable data imputation method would assist us to obtain continuous observation of solar radiation. A station-by-station and method-by-method analysis was carried out to understand the performance of each model. Based on our analysis, among all the data imputation methods, the Kalman data imputation method is better for Indian Weather condition. In addition, Kalman StructTS, Linear, Stine and Arima methods yield slightly inferior accuracy compared to Kalman, but outperform the other methods. The extended solar radiation data are used by solar forecasting models to provide the prediction of solar radiation at 15 SRRA stations. As far as short term forecasting model is concerned, the PSPI model outperforms the Smart Persistence model. However, the forecast error is increases with the forecasting horizon.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Microfluidic Uranium Microspheres Production for TRISO and Advanced Fuel Concepts

The purpose of this project was to expand existing internal gelation sol-gel capabilities at PNNL to explore producing uranium dioxide spheres for potential use as fuel kernels in next generation Tri-isotropic (TRISO) particle fuel. This project expands on previous sol-gel efforts at PNNL by (1) increasing the size regime of sphere production from the micro-fluidic range to the milli-fluidic range, and (2) producing uranium spheres. The approach involved first scaling up the channel size of the fluidic system to the millimeter range, with radiation safety considerations in mind; testing and demonstration on non-radioactive surrogate material, cerium oxide; then transitioning to uranium production and finally optimizing system parameters. Commercially available fluidic chips in the desired size range were could not be found, therefore the project designed and fabricated a T-junction with 1mm channels for droplet production. Because the production process is temperature sensitive, prior efforts have involved performing droplet production in a lab freezer. To reduce radiological waste and footprint, two alternative chilling methods were explored using aluminum thermal beads as a chill bath and a custom aluminum block fit to reagent reservoir sizes. Both were successful in the cerium tests, however the aluminum block design outperformed the thermal bead bath and was further adapted for the radiological test and production run in the Radiochemical Processing Laboratory (RPL). Gelation trials were performed to determine an acceptable range of feed solution parameters for the uranium dioxide gels, characterized by R-values, which is determined by the ratio of uranium nitrate to Hexamethylenetetramine (HMTA)/urea in the feed solution. R-values ranging from 1.6-2 were examined in the gelation trials, with only the 1.8 condition being tested in production. The project was successful in demonstrating a proof of concept design for producing uranium dioxide spheres, however further optimization is needed to dial in production parameters and improve sphere quality and homogeneity.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗