Distributed Control Architecture for an Integrated Accelerator & Experimental System
Abstract not provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided
Explore the source record for details and available documents.
Oak Ridge National Laboratory is working on completing the resonance parameter evaluation of 140,142Ce in the neutron energy range up to 200 keV. Performed with the support of the US Nuclear Criticality Safety Program, this evaluation aims to generate high-fidelity cerium cross-section and covariance data. A point-wise representation of the cross sections derived from the resonance parameters will provide improved calculations of self-shielding factors for nuclear criticality safety applications and additional evaluation support for continuous-energy radiation transport methodologies. The evaluation procedure uses the Reich Moore approximation of the R-matrix theory implemented in the SAMMY code system to fit resonance parameters to high-resolution transmission and neutron capture measurements of natCe performed in 2016 by the JRC-GEEL instrument scientists at the Geel Linear Accelerator facility as well as other experimental data sets on both natural and highly-enriched cerium samples available in the experimental library EXFOR. In the analyzed energy range this work aims to improve and extend the resolved resonance region present in the latest US nuclear data library ENDF/B-VIII.0 for 140,142Ce isotopes. This paper will present the preliminary results of the R-matrix analysis based on recently measured natCe transmission data.
Big discoveries need big detectors, and Fermilab’s Deep Underground Neutrino Experiment is one of the biggest. Fermilab plans to shoot beams of neutrinos and antimatter neutrinos through the Earth from Chicago to western South Dakota. The DUNE experiment will study neutrino interactions in great detail, with special attention on (a) comparing the behaviors of neutrinos vs. antineutrinos, (b) looking for proton decay, and (c) searching for the neutrinos emitted by supernovae. The experiment is being built and should start operations in the mid-to-late 2020s. In this video, Fermilab’s Dr. Don Lincoln gives us the lowdown on this fascinating project.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The LANL 2.5-cell, normal-conducting radio-frequency (NCRF) injector has been fabricated. We present initial results of low-power RF measurements (cavity Q, cavity field map, coupling beta, etc.) of the NCRF injector. The measured cavity Q and relative fields are found to be in good agreement with the design calculations and earlier measurements of Glidcop properties. However, the coupling beta of the ridge-loaded waveguides is found to be significantly higher than the design point. The impact of these low-power measurement results on the planned high-power RF and electron beam tests will be discussed.
This paper presents the results of the 2024 Summer Students Italian program at the Fermi National Accelerator Laboratory completed by participant Lorenzo Unich, which lasted between the 27th of July and the 29th of September. This project, which bears the same title of this paper, was supervised by Marco del Tutto, researcher at the Fermi National Accelerator Laboratory. In the first section, we introduce the instruments used throughout the project, detailing their origins and the goals of the traineeship. The second section presents the hardware work conducted, while the final section focuses on the simulations performed for the experimental apparatus. Unless otherwise cited, all pictures and graphs are original.
This document outlines measurements made by Idaho National Laboratory (INL) staff at the Berkeley Lab Laser Accelerator (BELLA) Center. Measurements of a mono-energetic Thomson photon beam were made with various INL instruments. The photon beam was generated by a laser-plasma accelerator system. This project is referred to by the name Laser Wake. Key Lawrence Berkeley National Laboratory (LBNL) personnel involved include Liona Fan-Chiang, Cameron Geddes, Anthony Gonsalves, Robert Jacob, Tobias Ostermayr, and Hai-En Tsai.
Results for the development of a field ready multi-isotopic analyzer for 12 CO 2 , 13 CO 2 and 14 CO 2 and applications for carbon capture and storage (CCS) containment performance are described. A design goal of the field platform was to provide isotopic data with a high data rate, a standardized reference baseline and acceptable precision (e.g., ~ ±50 per mil D 14 CO 2 ) for detection and quantification of fossil-fuel CO 2 CCS leakage scenarios. The instrument platform was not designed to replace high precision accelerator mass spectrometry. An additional goal was to combine project scale isotopic data and associated fluxes with unique financial instruments linking CCS containment performance to a publicly traded security providing project revenue to stakeholders. While the primary goals of the project were attained additional work is needed for the instrument platform and deployment within a full scale CCS site that was not available during the project timeframe.
The Sensor Technologies for Advanced Reactors Virtual Workshop—sponsored by the Gateway for Accelerated Innovation in Nuclear (GAIN), the Electric Power Research Institute, and the Nuclear Energy Institute—was held to exchange information on sensors and sensor technologies of interest to advanced nuclear technology developers, commercial instrument suppliers, and sensor researchers from Department of Energy (DOE) national laboratories, universities, and industry. The workshop objectives were to discuss measurement requirements and sensor needs for advanced reactor concepts, understand current national laboratory capabilities and accelerated development approaches for sensors and instrumentation, and identify gaps so as to inform applicable DOE Office of Nuclear Energy (DOE-NE) research programs. Due to the complexity of holding group discussions on individual gaps, a survey was sent to workshop participants, and personalized one-on-one feedback sessions were held to elicit additional information. Summaries of these sessions are provided in this gap assessment report.
The Spallation Neutron Source facility is a short-pulsed spallation source for condensed matter research using slow neutron scattering. Neutron beams with useful energies ranging from 0.1 meV to 10 eV are brought from a target-moderator-reflector assembly down neutron beamlines to scatter from a variety of materials under study. As of early 2014, SNS routinely provides 1.4 MW (time-averaged) proton power at around 940 MeV to a mercury spallation target at 60 Hz in sub-microsecond pulses. In nearly all cases, the pulsed nature of the neutron source is used, via time-of-flight techniques, to precisely identify the energy of each neutron detected. These neutrons are frequently of such low energy, and consequent slow velocity, that they are not detected until several additional accelerator pulses have taken place. A time-dependent background feature, commonly called the 'prompt pulse,' can contaminate the recorded data. This prompt pulse arises in part from fast and high-energy neutrons and photons produced during the various source reactions, and appears at the same apparent time as the proton pulse striking the target (that is, with negligible time-of-flight delay), often obscuring the data of interest in the individual experiment. We describe here measurements of the fast and high-energy neutron and photon background around the SNS neutron scattering instruments appearing in time with the SNS accelerator pulse structure. Our measurements to date indicate that the liquid scintillator array we have deployed can satisfactorily function in the SNS environment and provide neutron-photon discriminated time/energy spectra of background sources contribution to observed, problematic SNS scattering instrument backgrounds. We will continue measurements and analysis to provide unfolded neutron energy spectra, and through longitudinal studies correlate observed changes in those spectra to external changes at SNS. (authors)
We discuss the physics case for a new experimental setup that consists of the Crystal Ball multiphoton spectrometer and the CLAS12 forward detector installed at the tagged photon beam of Hall-B at JLab. The proposed apparatus will provide nearly 4{pi} sr coverage and good energy and angular resolution for photons and protons allowing a detailed high statistics investigation of the reactions with multiple photons. Such setup can be used to investigate the spectrum of doubly-strange {Xi} via their neutral decays, test C, CP, and T invariance in the neutral and charged decays of {eta} and {eta}' perform precise measurements of the Dalitz and double Dalitz decays of pseudoscaler and vector mesons, etc. Such data may also shed new light on the existence and the properties of the earlier claimed light exotic mesons.
The low-{beta} magnet systems are located in the Large Hadron Collider (LHC) insertion regions around the four interaction points. They are the key elements in the beams focusing/defocusing process allowing proton collisions at luminosity up to 10{sup 34}cm{sup -2}s{sup -1}. Those systems are a contribution of the US-LHC Accelerator project. The systems are mainly composed of the quadrupole magnets (triplets), the separation dipoles and their respective electrical feed-boxes (DFBX). The low-{beta} magnet systems operate in an environment of extreme radiation, high gradient magnetic field and high heat load to the cryogenic system due to the beam dynamic effect. Due to the severe environment, the robustness of the diagnostics is primordial for the operation of the triplets. The hardware commissioning phase of the LHC was completed in February 2010. In the sake of a safer and more user-friendly operation, several consolidations and instrumentation modifications were implemented during this commissioning phase. This paper presents the instrumentation used to optimize the engineering process and operation of the final focusing/defocusing quadrupole magnets for the first years of operation.