Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Dual-Zone Solar Control Indoor Shade: Demonstration at the Ronald V. Dellums Federal Building and U.S. Courthouse, 1301 Clay Street, Oakland, California and the Lawrence Berkeley National Laboratory Advanced Windows Testbed, Berkeley, California

Standard window shades are used to control sunlight, glare, window heat gains, and daylight. The challenge with conventional shades is that once the shades are lowered to reduce discomfort, daylight is reduced, which, in turn, increases the need for electric lighting. View is also obstructed, reducing the occupants’ connection to the outdoors. The strategy of subdividing the window wall and admitting daylight from above and controlling sunlight and view through the lower aperture can yield significant energy and peak demand savings over conventional shading systems, and improve the daylight quality of the indoor environment. This study evaluated a dual zone solar control (DZSC) shade with an upper, automated, horizontal, venetian blind with concave-up, matte white slats and a lower, manually operated, roller shade made of a transparent, reflective film. The automatic controls were designed to adjust the upper slat angle to maximize daylight to the room interior. The lower shade, when lowered, provided an unobstructed view to the outdoors. For the qualitative analysis, the DZSC shades were installed on windows in the southeast half of one floor in the Ronald V. Dellums Federal Building and U.S. Courthouse or hereafter referred to as the Oakland Federal Building (OFB) in Oakland, California. The position of the DZSC shades were observed and recorded periodically. Surveys were issued to occupants in the private offices and open plan workstations affected by the shades. For the quantitative analysis, the DZSC shades were installed in the south-facing windows of thermally isolated, fully instrumented, test chambers in the Advanced Windows Testbed at the Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California. Measurements of window heat loads, daylight illuminance and environmental conditions related to visual and thermal comfort were collected over a six-month, solstice-to-solstice period. The performance of the DZSC shade was compared to fabric roller shades and venetian blinds since these are the two most common types of shades used in both commercial and Federal buildings. Several DZSC design permutations were evaluated: 1) manual or automated control of the upper louver system (“man” or “auto”) and 2) tinted or silvered reflective film for the lower shade (“Gray-Gray (GG)” or “Gray-Silver (GS)”1). The automated, reflective shade (auto-GS) reduced dimmable fluorescent lighting energy use by 51% and window cooling load by 13-15% compared to a conventional fabric roller shade with dual-pane, spectrally selective, low-e windows during the summer period (winter period was not measured). Qualitative analysis revealed that the auto-GS shade was preferred by 80% of the survey respondents compared to the existing vertical fabric blinds with single-pane, tinted windows in the occupied building. Survey results indicated that visual discomfort was reduced and thermal discomfort was also reduced during warm or hot weather. Occupants expressed greater satisfaction with the unobstructed view. Installation and commissioning of the DZSC shades was fairly straightforward with some minor problems due to inadequate installation instructions and improper wiring. A few occupants expressed dissatisfaction with the automatic controls for the upper louvers due to visual discomfort, erroneous control, and motor noise.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Advancement for Active Remote Sensing of Carbon Dioxide from Space Using the ASCENDS CarbonHawk Experiment Simulator: First Results

The ASCENDS CarbonHawk Experiment Simulator (ACES) is a newly developed lidar developed at NASA Langley Research Center and funded by NASA's Earth Science Technology Office (ESTO) Instrument Incubator Program (IIP) that seeks to advance technologies critical to measuring atmospheric column carbon dioxide (CO2) mixing ratios in support of the NASA Active Sensing of CO2 Emissions over Nights, Days, and Seasons (ASCENDS) mission. The technology advancements targeted include: (1) increasing the power-aperture product to approach ASCENDS mission requirements by implementing multi-aperture telescopes and multiple co-aligned laser transmitters; (2) incorporating high-efficiency, high-power Erbium-Doped Fiber Amplifiers (EDFAs); (3) developing and incorporating a high-bandwidth, low-noise HgCdTe detector and transimpedence amplifier (TIA) subsystem capable of long-duration autonomous operation on Global Hawk aircraft, and (4) advancing algorithms for cloud and aerosol discrimination. The ACES instrument architecture is being developed for operation on high-altitude aircraft and will be directly scalable to meet the ASCENDS mission requirements. These technologies are critical towards developing not only spaceborne instruments but also their airborne simulators, with lower platform requirements for size, mass, and power, and with improved instrument performance for the ASCENDS mission. ACES transmits five laser beams: three from commercial EDFAs operating near 1.57 microns, and two from the Exelis oxygen (O2) Raman fiber laser amplifier system operating near 1.26 microns. The three EDFAs are capable of transmitting up to 10 watts average optical output power each and are seeded by compact, low noise, stable, narrow-linewidth laser sources stabilized with respect to a CO2 absorption line using a multi-pass gas absorption cell. The Integrated-Path Differential Absorption (IPDA) lidar approach is used at both wavelengths to independently measure the CO2 and O2 column number densities and retrieve the average column CO2 mixing ratio. The ACES receiver uses three fiber-coupled 17.8-cm diameter athermal telescopes. The transmitter assembly consists of five fiber-coupled laser collimators and an associated Risley prism pair for each laser to co-align the outgoing laser beams and to align them with the telescope field of view. The backscattered return signals collected by the three telescopes are combined in a fiber bundle and sent to a single low noise detector. The detector/TIA development has improved the existing detector subsystem by increasing its bandwidth to 4.7 MHz from 500 kHz and increasing the duration of autonomous, service-free operation periods from 4 hours to >24 hours. The new detector subsystem enables the utilization of higher laser modulation rates, which provides greater flexibility for implementing advanced thin-cloud discrimination algorithms as well as improving range-determination resolution and error reduction. The cloud/aerosol discrimination algorithm development by Langley and Exelis features a new suite of algorithms for the minimization/elimination of bias errors in the return signal induced by the presence of intervening thin clouds. Multiple laser modulation schemes are being tested in an effort to significantly mitigate the effects of thin clouds on the retrieved CO2 column amounts. Full instrument development concluded in the spring of 2014. After ground range tests of the instrument, ACES successfully completed six test flights on the Langley Hu-25 aircraft in July, 2014, and recorded data at multiple altitudes over land and ocean surfaces with and without intervening clouds. Preliminary results from these test flights will be presented in this paper.

Obland, Michael D.↗

Beyond the cockpit: The visual world as a flight instrument

The use of cockpit instruments to guide flight control is not always an option (e.g., low level rotorcraft flight). Under such circumstances the pilot must use out-the-window information for control and navigation. Thus it is important to determine the basis of visually guided flight for several reasons: (1) to guide the design and construction of the visual displays used in training simulators; (2) to allow modeling of visibility restrictions brought about by weather, cockpit constraints, or distortions introduced by sensor systems; and (3) to aid in the development of displays that augment the cockpit window scene and are compatible with the pilot's visual extraction of information from the visual scene. The authors are actively pursuing these questions. We have on-going studies using both low-cost, lower fidelity flight simulators, and state-of-the-art helicopter simulation research facilities. Research results will be presented on: (1) the important visual scene information used in altitude and speed control; (2) the utility of monocular, stereo, and hyperstereo cues for the control of flight; (3) perceptual effects due to the differences between normal unaided daylight vision, and that made available by various night vision devices (e.g., light intensifying goggles and infra-red sensor displays); and (4) the utility of advanced contact displays in which instrument information is made part of the visual scene, as on a 'scene linked' head-up display (e.g., displaying altimeter information on a virtual billboard located on the ground).

Johnson, W. W.↗

Problems and advances in monitoring horizontal strain

The modern instrumentation is described for use in geodesy for the detection of the deformations of the crust of the earth. Problems are listed. Needs are discussed for the survey of the physical quantities of interest in geodesy, geology, geophysics, and engineering such as the strain invariants, the optimal network of baselines and the accuracy. An analytic method is also given for the computation of the effect of a source of dilatation in a spherical earth.

Caputo, M.↗

High Resolution Imaging Spectrometer (HIRIS) - A major advance in imaging spectrometry

HIRIS, a facility instrument on the Earth Observing System Platform, will enable scientists to both identify and interpret changes, in the global environment, at a level of detail unavailable with previous instrumentation. This instrument will make localized measurements of biological, ecological, climatological, hydrological, and geological properties, and, with its finer wavelength sampling and full spectral coverage over the wavelength region of interest, will allow these properties to be identified and studied quantitatively from space. The data obtained will be downlinked from space, processed, catalogued, stored in active archives for easy access, and distributed to users.

Rockey, Donald E.↗

Performance of the Advanced Thin Ionization Calorimeter (ATIC)

The ATIC instrument is a balloon-borne experiment capable of measuring cosmic ray elemental spectra from 50 GeV to 100 TeV for nuclei from H to Fe with a fully active Bismuth Germanate calorimeter. Several Long Duration Balloon flights from McMurdo station, Antarctica are scheduled. The detector was tested with high energy electron, proton, and pion beams at CERN. We present results for 150 and 375 GeV protons, and 150 GeV pions and comparison with a GEANT Monte Carlo.

Case, G.↗

PACE UV-VIS Polarimetric Remote Sensing of Atmosphere-Ocean Systems: Sensitivity to Variations in Brown Carbon

The NASA Plankton, Aerosol, Cloud, and ocean Ecosystem (PACE) mission, scheduled for launch in 2024, will carry two instruments that measure ultraviolet (UV) radiance emerging from the top of the atmosphere: the Ocean Color Instrument (OCI) and the Spectro-Polarimeter for Planetary Exploration (SPEXone) instrument. OCI will provide single-view, hyperspectral radiometric data, whereas SPEXone will provide multi-angle, multispectral polarimetric data. Together, these instruments will be the most advanced in NASA’s history for the combined observation of ocean color and atmospheric aerosols in the UV, and they will therefore provide unprecedented research opportunities for the ocean color and atmospheric aerosol communities. In particular, UV observations are best suited to retrieve properties of Colored Dissolved Organic Matter (CDOM) in the ocean, and of Brown Carbon (BrC) aerosols in the atmosphere. However, both CDOM and BrC exhibit very similar absorption spectra in the UV and the visible (VIS) spectrum; hence, care must be taken in accurately modeling these spectra for analyses of OCI and SPEXone measurements. In this presentation, we summarize a simple but highly accurate three-parameter model for complex refractive index spectra of BrC in the UV and VIS. We apply this model to simulations of PACE-like total and polarized multiangle radiance in the UV, and demonstrate that the impact of BrC and CDOM variations can be similar in total radiance, but is easy to distinguish in polarized radiance.

PACE↗

Laser Wakefield Acceleration: Structural and Dynamic Studies. Final Technical Report ER40954

Particle accelerators enable scientists to study the fundamental structure of the universe, but have become the largest and most expensive of scientific instruments. In this project, we advanced the science and technology of laser-plasma accelerators, which are thousands of times smaller and less expensive than their conventional counterparts. In a laser-plasma accelerator, a powerful laser pulse exerts light pressure on an ionized gas, or plasma, thereby driving an electron density wave, which resembles the wake behind a boat. Electrostatic fields within this plasma wake reach tens of billions of volts per meter, fields far stronger than ordinary non-plasma matter (such as the matter that a conventional accelerator is made of) can withstand. Under the right conditions, stray electrons from the surrounding plasma become trapped within these “wake-fields”, surf them, and acquire energy much faster than is possible in a conventional accelerator. Laser-plasma accelerators thus might herald a new generation of compact, low-cost accelerators for future particle physics, x-ray and medical research. In this project, we made two major advances in the science of laser-plasma accelerators. The first of these was to accelerate electrons beyond 1 gigaelectronvolt (1 GeV) for the first time. In experimental results reported in Nature Communications in 2013, about 1 billion electrons were captured from a tenuous plasma (about 1/100 of atmosphere density) and accelerated to 2 GeV within about one inch, while maintaining less than 5% energy spread, and spreading out less than ½ milliradian (i.e. ½ millimeter per meter of travel). Low energy spread and high beam collimation are important for applications of accelerators as coherent x-ray sources or particle colliders. This advance was made possible by exploiting unique properties of the Texas Petawatt Laser, a powerful laser at the University of Texas at Austin that produces pulses of 150 femtoseconds (1 femtosecond is 10-15 seconds) in duration and 150 Joules in energy (equivalent to the muzzle energy of a small pistol bullet). This duration was well matched to the natural electron density oscillation period of plasma of 1/100 atmospheric density, enabling efficient excitation of a plasma wake, while this energy was sufficient to drive a high-amplitude wake of the right shape to produce an energetic, collimated electron beam. Continuing research is aimed at increasing electron energy even further, increasing the number of electrons captured and accelerated, and developing applications of the compact, multi-GeV accelerator as a coherent, hard x-ray source for materials science, biomedical imaging and homeland security applications. The second major advance under this project was to develop new methods of visualizing the laser-driven plasma wake structures that underlie laser-plasma accelerators. Visualizing these structures is essential to understanding, optimizing and scaling laser-plasma accelerators. Yet prior to work under this project, computer simulations based on estimated initial conditions were the sole source of detailed knowledge of the complex, evolving internal structure of laser-driven plasma wakes. In this project we developed and demonstrated a suite of optical visualization methods based on well-known methods such as holography, streak cameras, and coherence tomography, but adapted to the ultrafast, light-speed, microscopic world of laser-driven plasma wakes. Our methods output images of laser-driven plasma structures in a single laser shot. We first reported snapshots of low-amplitude laser wakes in Nature Physics in 2006. We subsequently reported images of high-amplitude laser-driven plasma “bubbles”, which are important for producing electron beams with low energy spread, in Physical Review Letters in 2010. More recently, we have figured out how to image laser-driven structures that change shape while propagating in a single laser shot. The latter techniques, which use the methods of computerized tomography, were demonstrated on test objects – e.g. laser-driven filaments in air and glass – and reported in Optics Letters in 2013 and Nature Communications in 2014. Their output is a multi-frame movie rather than a snapshot. Continuing research is aimed at applying these tomographic methods directly to evolving laser-driven plasma accelerator structures in our laboratory, then, once perfected, to exporting them to plasma-based accelerator laboratories around the world as standard in-line metrology instruments.

43 PARTICLE ACCELERATORS↗

Cable aging and condition monitoring of radiation resistant nano-dielectrics in advanced reactor applications

Cross-linked polyethylene (XLPE) nanocomposites have been developed in an effort to improve cable insulation lifetime to serve in both instrument cables and auxiliary power systems in advanced reactor applications as well as to provide an alternative for new or retro-fit cable insulation installations. Nano-dielectrics composed of different weight percentages of MgO & SiO 2 have been subjected to radiation at accumulated doses approaching 20 MRad and thermal aging temperatures exceeding 100 C. Depending on the composition, the performance of the nanodielectric insulation was influenced, both positively and negatively, when quantified with respect to its electrical and mechanical properties. For virgin unradiated or thermally aged samples, XLPE nanocomposites with 1wt.% SiO 2 showed improvement in breakdown strength and reduction in its dissipation factor when compared to pure undoped XLPE, while XLPE 3wt.% SiO 2 resulted in lower breakdown strength. When aged in air at 120 C, retention of electrical breakdown strength and dissipation factor was observed for XLPE 3wt.% MgO nanocomposites. Irrespective of the nanoparticle species, XLPE nanocomposites that were gamma irradiated up to the accumulated dose of 18 MRad showed a significant drop in breakdown strength especially for particle concentrations greater than 3 wt.%. Additional attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy measurements suggest changes in the structure of the XLPE SiO 2 nanocomposites associated with the interaction of silicon and oxygen. Discussion on the relevance of property changes with respect to cable aging and condition monitoring is presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Wideband Instrument for Snow Measurements (WISM)

This presentation discusses current efforts to develop a Wideband Instrument for Snow Measurements (WISM). The objective of the effort are as follows: to advance the utility of a wideband active and passive instrument (8-40 gigahertz) to support the snow science community; improve snow measurements through advanced calibration and expanded frequency of active and passive sensors; demonstrate science utility through airborne retrievals of snow water equivalent (SWE); and advance the technology readiness of broadband current sheet array (CSA) antenna technology for spaceflight applications.

Radiometer↗

Automated single-ion peak fitting as an efficient approach for analyzing complex chromatographic data

Chromatography provides important detail on the composition of environmental samples and their chemical processing. However, the complexity of these samples and their tendency to contain many structurally and chemically similar compounds frequently results in convoluted or poorly resolved data. Data reduction from raw chromatograms of complex environmental data into integrated peak areas consequently often requires substantial operator interaction. This difficulty has led to a bottleneck in analysis that increases analysis time, decreases data quality, and will worsen as advances in field-based instrumentation multiply the quantity and informational density of data produced. In this work, we develop and validate an automated approach to fitting chromatographic data within a target retention time window with a combination of multiple idealized peaks (Gaussian peaks either with or without an exponential decay component). Herein we compare this single-ion peak fitting approach to drawn baseline integration methods of more than 70,000 peaks collected by field-based chromatographs spanning across a wide range of volatilities and functionalities. Accuracy of peak fitting under real-world conditions is found to be within 10%. The quantitative parameters describing the fit (e.g. coefficients, fit residuals, etc.) are found to provide valuable information to increase the efficiency of quality control and provide constraints to accurately integrate peaks that are significantly convoluted with neighboring peaks. Implementation of the peak fitting method is shown to yield accurate integration of peaks otherwise too poorly resolved to separate into individual compounds and improved quantitative metrics to determine the fidelity of the data reduction process, while substantially decreasing the time spent by operators on data reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparative Analysis of Natural Gas Cogeneration Incentives on Electricity Production in Latin America

An analysis to assess the influence of country-dependent variables and incentives on the feasibility of natural gas cogeneration projects in Latin America is presented in this work. The analysis is performed using a hypothetical industrial plant, where the cogeneration solution consists in the recovery of waste heat from the power generation for steam production. The feasibility is evaluated by calculating the Return of Investment (ROI) and the Internal Rate of Return (IRR) of the project. Eight Latin American countries are studied considering their specific natural gas markets, regulation, and macroeconomic variables. Two scenarios, electricity production for self-consumption and electricity production with power surplus sale, are independently analyzed considering the effects of available incentives. In the countries where the project is feasible, the application of incentives leads to a significant reduction in the ROI and, consequently, to an increment in the IRR. The effect of the interest rate and environmental impact were also analyzed. In general terms, along the region, the regulation for cogeneration is incipient while incentives are very standard and similar respect to lowering of import, Value-Added Tax (VAT), and income taxes, which seems to be designed purely to promote capital investment. Following the results from this study, it is of paramount importance to create new policy instruments in the future to advance the regulatory framework for cogeneration in Latin America.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

In situ synthesis and characterization of uranium carbide using high temperature neutron diffraction

Advances in neutron flux, neutron instrumentation, and sample environments over the past years allowed the development of unique techniques to characterize material synthesis and processing. The available infrastructure at LANL allows to apply these techniques to radioactive materials or materials containing actinides. Here, we present capabilities and results to characterize materials in situ at temperatures above 2000 Celsius degrees such as in loss-of-coolant accidents. Temperatures in excess of 2000 C. degrees are not readily achieved and neutrons are one of a few probes to characterize materials under these conditions. Research in refractory materials, phase diagram studies or accident scenarios for nuclear materials are research areas where such extreme conditions are required. As an example, we present the formation of UC{sub x} from UO{sub 2+x} and graphite in situ using high temperature neutron diffraction with particular focus on resolving the conflicting reports on the crystal structure of non-quenchable cubic UC{sub 2}. The ability to follow the reaction UO{sub 2}+C → UC{sub x}+CO{sub y} in situ with neutron diffraction allows us to conclude that the reaction occurs within minutes over a temperature range of 60 Celsius degrees. The initiation of the reaction is far below the reaction temperature of 2000 C. degrees reported for this reaction in standard text books on actinide chemistry. This may be due to the unusually small ∼100 nm grain size of our UO{sub 2} initial powder. Furthermore, the holding time of several hours reported in the literature would be unnecessary. The neutron diffraction data collected for the cubic high temperature UC{sub 2} phase unambiguously confirmed the disordered C-C dumbbells and excluded structures previously determined by X-ray diffraction.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A holistic approach to the optimization of neutron beam transport at the LANSCE facility

An advanced neutron beam collimation system has been developed as part of an effort to optimize neutron beam transport at the Weapons Neutron Research (WNR) Facility, located within the Los Alamos Neutron Science Center (LANSCE). The goal of this work was to develop and demonstrate techniques to tailor neutron delivery in order to provide maximum available flux on sample with a specific beam profile, while simultaneously reducing unwanted background. A holistic approach was taken, upgrading the facility spallation target, facility metrology infrastructure, and flight path shutter insert to support the implementation of this advanced collimation system. Here, modern instruments and software were employed to conduct facility surveys, characterization of as-built geometry of critical components, 3D ray tracing and neutron transport calculations. Beam images and flux measurements were acquired after installation to evaluate the performance of the collimation system and to demonstrate consistent agreement with MCNP simulations which showed an 87% increase of flux on sample while providing suppression of background neutron impingement on the sample frame by 10 3 .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

mzPeak: Designing a Scalable, Interoperable, and Future-Ready Mass Spectrometry Data Format

Advances in mass spectrometry (MS) instrumentation, such as higher resolution, faster scan speeds, and improved sensitivity, have significantly increased the volume and complexity of data. The growing adoption of imaging and ion mobility further amplifies these challenges across MS-based omics fields, including proteomics, metabolomics, and lipidomics. While these technologies unlock new possibilities, they also present significant challenges in data management, storage, and accessibility. Existing open formats, such as the XML-based community standards mzML and imzML, struggle to meet the demands of modern MS workflows due to their large file sizes, slow data access, and limited metadata support. Vendor-specific formats, while optimized for proprietary instruments, lack interoperability, comprehensive metadata support and long-term archival reliability. This white paper lays the groundwork for mzPeak, a next-generation community data format designed to address these challenges and support high-throughput, multi-dimensional MS workflows. By adopting a hybrid model that combines efficient binary storage for numerical data and both human and machine-readable metadata storage, mzPeak will reduce file sizes, accelerate data access, and offer a scalable, adaptable solution for evolving MS technologies. For researchers, mzPeak will enable enhanced interoperability across platforms, seamless support for complex workflows including ion mobility and MS imaging, and faster data access compared to existing community formats such as mzML. Its design will ensure data is managed in compliance with regulatory standards, essential for applications such as precision medicine and chemical safety, where long-term data integrity and accessibility are critical. For vendors, mzPeak provides a streamlined, open alternative to proprietary formats, reducing the burden of regulatory compliance while aligning with the industry's push for transparency and standardization. By offering a high-performance, interoperable solution, mzPeak positions vendors to meet customer demands for sustainable data management tools which will be able to handle emerging and future data types and workflows. mzPeak aspires to become the cornerstone of MS data management, empowering researchers, vendors, and developers to innovate and collaborate more effectively.

data formats↗

Imaging from Macro to Nanoscale: Multimodal Advances in Chemical and Biomedical Imaging

Imaging increasingly serves as a multiscale framework for linking molecular mechanisms to cellular behavior, tissue architecture, and organ phenotypes in biology and unraveling fundamental processes in chemistry, physics and materials science. This Perspective highlights recent advances in chemical and biomedical imaging across macro-, micro-, and nanoscales, using representative examples published in Chemical and Biomedical Imaging (CBMI). At the macroscale, we discuss chemically selective MRI, including endogenous and exogenous CEST strategies, together with photoacoustic imaging as a hybrid modality with functional and chemical contrast. At the microscale, we consider fluorescence, label-free optical and vibrational imaging, and selected X-ray approaches that expand sensitivity, specificity, and temporal resolution in biological and materials systems. At the nanoscale, we highlight super-resolution fluorescence microscopy, single-molecule methods, tip-enhanced Raman spectroscopy, and correlative imaging strategies that resolve local heterogeneity and molecular organization. Across scales, a common theme emerges that advances in probes, contrast mechanisms, instrumentation, and sample handling are enabling chemically informed imaging that connects molecular specificity with biological context.

multiscale imaging↗

Bibliometric review and recent advances in total scattering pair distribution function analysis: 21 years in retrospect

Global research activities have been driven by the quest to develop and characterize novel materials for technological advancements. The total scattering pair distribution function (TSPDF) is a powerful and versatile characterization technique for examining the structural details of diverse complex materials including liquid, amorphous, disordered crystalline, and nanostructured materials. Thus, it is critical to keep track of research progress, identify research gaps, and future research directions of the application of the TSPDF technique in materials development and discovery. In this work, a bibliometric analysis of literature regarding the TSPDF technique between 2000 and 2021 was conducted using datasets retrieved from the Web of Science database. The research trends based on publication outputs, research subject distribution, co-authorships among institutions, countries/regions, co-citation of referenced sources, and keyword co-occurrence are evaluated and discussed herein. The impact of the TSPDF technique is projected to increase due to its importance in probing emerging functional materials, and the advances in specialized facilities and instrumentation among the scientific communities engaged with it. Finally, current and emerging research hotspots related to TSPDF technique such as catalysis, computer modeling and simulation, pharmaceutics, machine learning, hydrogen storage, battery materials, and layered structured materials are also identified and discussed.

36 MATERIALS SCIENCE↗

PLUTO AND CHARON WITH THE HUBBLE SPACE TELESCOPE. II. RESOLVING CHANGES ON PLUTO'S SURFACE AND A MAP FOR CHARON

We present new imaging of the surface of Pluto and Charon obtained during 2002-2003 with the Hubble Space Telescope (HST) Advanced Camera for Surveys (ACS) instrument. Using these data, we construct two-color albedo maps for the surfaces of both Pluto and Charon. Similar mapping techniques are used to re-process HST/Faint Object Camera (FOC) images taken in 1994. The FOC data provide information in the ultraviolet and blue wavelengths that show a marked trend of UV-bright material toward the sunlit pole. The ACS data are taken at two optical wavelengths and show widespread albedo and color variegation on the surface of Pluto and hint at a latitudinal albedo trend on Charon. The ACS data also provide evidence for a decreasing albedo for Pluto at blue (435 nm) wavelengths, while the green (555 nm) data are consistent with a static surface over the one-year period of data collection. We use the two maps to synthesize a true visual color map of Pluto's surface and investigate trends in color. The mid- to high-latitude region on the sunlit pole is, on average, more neutral in color and generally higher albedo than the rest of the surface. Brighter surfaces also tend to be more neutral in color and show minimal color variations. The darker regions show considerable color diversity arguing that there must be a range of compositional units in the dark regions. Color variations are weak when sorted by longitude. These data are also used to constrain astrometric corrections that enable more accurate orbit fitting, both for the heliocentric orbit of the barycenter and the orbit of Pluto and Charon about their barycenter.

79 ASTRONOMY AND ASTROPHYSICS↗