Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Photon Source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

HIGH PRECISION K-SHELL PHOTOABSORPTION CROSS SECTIONS FOR ATOMIC OXYGEN: EXPERIMENT AND THEORY

Photoabsorption of atomic oxygen in the energy region below the 1s {sup -1} threshold in X-ray spectroscopy from Chandra and XMM-Newton is observed in a variety of X-ray binary spectra. Photoabsorption cross sections determined from an R-matrix method with pseudo-states and new, high precision measurements from the Advanced Light Source (ALS) are presented. High-resolution spectroscopy with E/{Delta}E Almost-Equal-To 4250 {+-} 400 was obtained for photon energies from 520 eV to 555 eV at an energy resolution of 124 {+-} 12 meV FWHM. K-shell photoabsorption cross section measurements were made with a re-analysis of previous experimental data on atomic oxygen at the ALS. Natural line widths {Gamma} are extracted for the 1s {sup -1}2s {sup 2}2p {sup 4}({sup 4} P)np {sup 3} P Degree-Sign and 1s {sup -1}2s {sup 2}2p {sup 4}({sup 2} P)np {sup 3} P Degree-Sign Rydberg resonances series and compared with theoretical predictions. Accurate cross sections and line widths are obtained for applications in X-ray astronomy. Excellent agreement between theory and the ALS measurements is shown which will have profound implications for the modeling of X-ray spectra and spectral diagnostics.

79 ASTRONOMY AND ASTROPHYSICS↗

Nanocrystal‐Enabled Perovskite Heterojunctions in Photovoltaic Applications and Beyond

Abstract Heterojunctions are used to tailor the properties of semiconductors in optoelectronic devices, yet for emerging devices composed of metal halide perovskites, fabricating perovskite/perovskite heterojunctions has proved challenging due to solvent incompatibilities and rapid homogenization due to ion migration. Recent studies have demonstrated various strategies for using perovskite nanocrystals as a component to fabricate perovskite/perovskite heterojunctions, either with a perovskite thin film or a second nanocrystal layer. Heterojunctions such as these can impart many advantages of both bulk and nanocrystalline perovskite morphologies. This perspective focuses on recent developments of solution‐processed perovskite heterojunctions for solar cells and novel optoelectronic devices, in particular, highlighting the demonstrated and potential advantages of nanocrystal‐enabled fabrication strategies. A central tenet of this perspective is that the synthesis and dispersion of perovskite nanocrystals in non‐polar organic solvents offers a key processing advantage over traditional perovskite precursor solutions in polar solvents since the former allows for layer‐by‐layer deposition without dissolving an underlying perovskite film or crystal. This processing advantage, coupled with nanocrystal size control and ligand chemistry, enables perovskite heterojunctions with highly tunable optical and electrical properties. Such heterojunctions may enable disruptive technological advances in broad classes of devices such as solar cells, photodetectors, sensors, and (in)coherent photon sources with tunable polarization.

14 SOLAR ENERGY↗

Photoselective isotope fractionation dynamics of N 2 with cosmo and atmospheric chemistry perspectives

Stable isotope ratio measurements provide valuable insights into a broad range of natural processes, from planetary atmospheres and climate to interstellar chemistry. Nitrogen, which has two stable isotopes, exhibits varying isotope ratios across the solar system. To model these observations, the isotope fraction as a function of energy is essential. At the Advanced Light Source (ALS), we measured the photodissociation of molecular nitrogen (N 2 ) with vacuum UV photons where a single photon is sufficiently energetic to dissociate the strong bond. The nitrogen atoms produced are scavenged with H 2 to form ammonia, whose isotopic makeup is determined. Blending the experiments with dynamical computations that include the shielding of light, we examine the isotopic composition and electronic atomic states produced. The measured photodissociation of N 2 at a natural isotopic composition with a frequency broad light beam exceptionally strongly favors the formation of the heavier nitrogen isotope, 15 N. Computations concur and suggest that the maximum in the quantum yield reflects significant variations in the specific electronic quantum states of the product N atoms that have quite different reactivities. Our quantum computations show that at similar energies, photodissociation of 14 N 14 N and 15 N 14 N can lead to different product channels. The computed dynamics include extensive state-selective spin–orbit and nonadiabatic couplings affecting the light absorption and dissociation pathways that proceed via the triplet manifold of states. Our results are relevant for future exploration missions, both in situ and sample-return and for other molecules such as O 2 and CO.

Komarova, Ksenia [Hebrew Univ. of Jerusalem (Israe↗

1.54 micron Emission from Erbium implanted GaN for Photonic Applications

The development of efficient and compact light sources operating at 1.54 micron is of enormous importance for the advancement of new optical communication systems. Erbium (1%) doped fiber amplifiers (EDFA's) or semiconductor lasers are currently being employed as near infrared light sources. Both devices, however, have inherent limitations due to their mode of operation. EDFA's employ an elaborate optical pumping scheme, whereas diode lasers have a strongly temperature dependent lasing wavelength. Novel light emitters based on erbium doped III-V semiconductors could overcome these limitations. Er doped semiconductors combine the convenience of electrical excitation with the excellent luminescence properties of Er(3+) ions. Electrically pumped, compact, and temperature stable optoelectronic devices are envisioned from this new class of luminescent materials. In this paper we discuss the potential of Er doped GaN for optoelectronic applications based on temperature dependent photoluminescence excitation studies.

Thaik, Myo↗

Broadband polarization-entangled source for C+L-band flex-grid quantum networks

The rising demand for transmission capacity in optical networks has motivated steady interest in expansion beyond the standard C-band (1530–1565 nm) into the adjacent L-band (1565–1625 nm) for an approximate doubling of capacity in a single stroke. However, in the context of quantum networking, the L-band has yet to be fully leveraged with the suite of advanced tools for characterization and management available from classical lightwave communications. In this work, we demonstrate an ultrabroadband two-photon source integrating both C- and L-band wavelength-selective switches for complete control of spectral routing and allocation across 7.5 THz in a single setup. Polarization state tomography of all 150 pairs of 25-GHz-wide channels reveals an average fidelity of 0.98 and total distillable entanglement greater than 181 kebits/s. This source is explicitly designed for flex-grid optical networks and can facilitate optimal utilization of entanglement resources across the full C+L-band.

42 ENGINEERING↗

Wavefront Preservation in Soft X-Ray Beamlines for the Advanced Light Source Upgrade

In the 4th generation of X-ray light sources, including Free-Electron Lasers (FEL) and Diffraction-Limited Storage Rings (DLSR), the emittance of the electron beam is small or negligible compared to the emittance of the photon beam produced by insertion devices, thus generating coherent beams of light. Over the next few years, several lightsource facilities will be built or upgraded to produce X-ray beams of unprecedented coherent flux. Delivering these exceptional beams to the sample chambers requires beamline optical systems that are designed to preserve the wavefront properties. Our goal in the Advanced Light Source upgrade project (ALS-U) is to create a new class of beamlines that reach diffraction-limited X-ray optical quality through tightly integrated, efficient optical systems, diagnostics, and adaptive mirrors, thus providing users with new scientific capabilities offered by coherent X-ray light interactions with matter. Herein we describe aspects of the beamlines’ design as they enter the project’s final design phase.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A cantilevered liquid-nitrogen-cooled silicon mirror for the Advanced Light Source Upgrade

This paper presents a novel cantilevered liquid-nitrogen-cooled silicon mirror design for the first optic in a new soft X-ray beamline that is being developed as part of the Advanced Light Source Upgrade (ALS-U) (Lawrence Berkeley National Laboratory, USA). The beamline is optimized for photon energies between 400 and 1400 eV with full polarization control. Calculations indicate that, without correction, this design will achieve a Strehl ratio greater than 0.85 for the entire energy and polarization ranges of the beamline. With a correction achieved by moving the focus 7.5 mm upstream, the minimum Strehl ratio is 0.99. This design is currently the baseline plan for all new ALS-U insertion device beamlines.

47 OTHER INSTRUMENTATION↗

Final Technical Report for Award DE-FG02-05ER41389 A New Electrostatically-Focused, UV HPD for Liquid Xenon: A Direct Comparison with APD, PMT, SiPM in an Integrated Database

Within the scope of the project, a LXe detector and associated gas handling and purification system were set up to study the response of various photodetectors to the VUV Xe light. In particular we tested an Advanced Photonix Large Area Avalanche Photodiode (APD), Silicon Photomultipliers (SiPMs) from two different sources and an Hamamtsu Photonics APD. As part of the XENON Dark Matter project, sponsored by the National Science Foundation, we have accumulated independent knowledge of the response of compact metal channel photomultipliers. At this stage, we conclude that the last are far superior in terms of reliability and performance in a LXe detector environment. More studies are needed with APDs and SiPMs in LXe, taking advantage of the improved performance of these sensors with time. We could not test a hybrid PMT (HPD) since the only available unit on loan from one manufacturer lacked the mechanical stability and was packaged in a form not compatible with LXe purity requirements. Meanwhile, within the XENON collaboration, we are developing with Hamamatsu a hybrid PMT which is named QUPID (Quartz Photon Intensifying Detector) which promises to solve the problems of radioactivity and purity encountered with previous HPDs. We attach to this report two papers which summarize in detail the experimental st-ups, procedures and results obtained with different APDs and SiPMs operated in LXe. We continue our investigations of APDs in view of their potential appication in large arrays for LXe detectors. We intend to publish the results once we complete tests of newly acquired Hamamatsu APDs.

02 PETROLEUM↗

ILC Positron Source Based on Laser Compton

Positron generation is one of the most difficult technical challenges among the ILC (International Linear Collider) subsystems. A positron source based on Laser Compton back scattering is an attractive and advanced option for the ILC positron source. Here, the positrons are generated, via the pair creation process, from high energy gamma rays which themselves are produced by Compton scattering of laser photons off a high-energy electron beam. Polarized positrons can be generated by employing a circularly polarized laser. The positron polarization is easily controlled and switched by changing the laser polarity. The electron beam can be unpolarized. The required electron energy is only a few GeV (in contrast, the ''undulator scheme'', another advanced option, requires at least 100 GeV or more) and the system can be prototyped and tested prior to the real construction. The laser Compton technology has many other applications like advanced X-ray sources and a good synergy is expected. In addition, this technology can be a powerful driving force for the ILC project attracting many researchers from outside the ILC community. The ILC positron source is a technical challenge and it will be realized only if the latest technologies are integrated seamlessly with the necessary R and D efforts for system specific issues. The latest technologies include high power lasers, high brightness electron beams, high finesse optical cavities for as laser-beam interaction point, etc. We present the design status and the related experimental efforts for the ILC positron source based on Laser Compton scattering. The respective advantages of various options for the electron beam (based on Linac, storage ring, and ERL) are also compared.

43 PARTICLE ACCELERATORS↗

Refractiveindex.info database of optical constants

Abstract We introduce the refractiveindex.info database, a comprehensive open-source repository containing optical constants for a wide array of materials, and describe in detail the underlying dataset. This collection, derived from a meticulous compilation of data sourced from peer-reviewed publications, manufacturers’ datasheets, and authoritative texts, aims to advance research in optics and photonics. The data is stored using a YAML-based format, ensuring integrity, consistency, and ease of access. Each record is accompanied by detailed metadata, facilitating a comprehensive understanding and efficient utilization of the data. In this descriptor, we outline the data curation protocols and the file format used for data records, and briefly demonstrate how the data can be organized in a user-friendly fashion akin to the books in a traditional library.

43 PARTICLE ACCELERATORS↗

Quantum defects in carbon nanotubes as single-photon sources

Single-photon emitters are essential components of emerging quantum technologies, including secure communication and quantum computing. Single-walled carbon nanotubes (SWCNTs) have emerged as a promising platform for quantum light sources due to their quasi-one-dimensional excitonic host structure and compatibility with telecom photonic systems. Recent advances in deterministic defect engineering—most notably the development of organic color centers (OCCs)—have enabled stable, chemically controllable, and spectrally tunable single-photon emission. OCC-based emitters have demonstrated single-photon purity exceeding 99% and, more recently, room-temperature photon indistinguishability, placing them among the few solid-state systems with quantum-grade performance under ambient conditions. This review surveys progress in the field from three complementary perspectives: chemical synthesis and quantum defect engineering, computational studies of structure-property relationships and excitonic behavior, and experimental investigations of quantum optical properties. We also discuss alternative approaches, including air-suspended SWCNTs and hybrid van der Waals heterostructures, highlighting opportunities and open challenges for scalable integration into quantum photonic platforms.

36 MATERIALS SCIENCE↗

High-rate multiplexed entanglement source based on time-bin qubits for advanced quantum networks

Entanglement distribution based on time-bin qubits is an attractive option for emerging quantum networks. We demonstrate a 4.09-GHz repetition rate source of photon pairs entangled across early and late time bins separated by 80 ps. Simultaneous high rates and high visibilities are achieved through frequency multiplexing the spontaneous parametric down conversion output into eight time-bin entangled channel pairs. We demonstrate entanglement visibilities as high as 99.4%, total entanglement rates up to 3.55×10 6 coincidences/s, and predict a straightforward path towards achieving up to an order of magnitude improvement in rates without compromising visibility. Finally, we resolve the density matrices of the entangled states for each multiplexed channel and express distillable entanglement rates in ebit/s, thereby quantifying the trade-off between visibility and coincidence rates that contributes to useful entanglement distribution. This source is a fundamental building block for high-rate entanglement-based quantum key distribution systems or advanced quantum networks.

Mueller, Andrew (ORCID:0000000265989732)↗

TU-EF-207-03: Advances in Stationary Breast Tomosynthesis Using Distributed X-Ray Sources

Breast imaging technology is advancing on several fronts. In digital mammography, the major technological trend has been on optimization of approaches for performing combined mammography and tomosynthesis using the same system. In parallel, photon-counting slot-scan mammography is now in clinical use and more efforts are directed towards further development of this approach for spectral imaging. Spectral imaging refers to simultaneous acquisition of two or more energy-windowed images. Depending on the detector and associated electronics, there are a number of ways this can be accomplished. Spectral mammography using photon-counting detectors can suppress electronic noise and importantly, it enables decomposition of the image into various material compositions of interest facilitating quantitative imaging. Spectral imaging can be particularly important in intravenously injected contrast mammography and eventually tomosynthesis. The various approaches and applications of spectral mammography are discussed. Digital breast tomosynthesis relies on the mechanical movement of the x-ray tube to acquire a number of projections in a predefined arc, typically from 9 to 25 projections over a scan angle of +/−7.5 to 25 degrees depending on the particular system. The mechanical x-ray tube motion requires relatively long acquisition time, typically between 3.7 to 25 seconds depending on the system. Moreover, mechanical scanning may have an effect on the spatial resolution due to internal x-ray filament or external mechanical vibrations. New x-ray source arrays have been developed and they are aimed at replacing the scanned x-ray tube for improved acquisition time and potentially for higher spatial resolution. The potential advantages and challenges of this approach are described. Combination of digital mammography and tomosynthesis in a single system places increased demands on certain functional aspects of the detector and overall performance, particularly in the tomosynthesis mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

60 APPLIED LIFE SCIENCES↗

Multi-pulse time resolved gamma ray spectroscopy of the advanced radiographic capability using gas Cherenkov diagnostics

The advanced radiographic capability located at the National Ignition Facility (NIF) uses high intensity, short pulse lasers to create bright photon sources for diagnosing high energy density experiments. There are radiographic needs for a multi-frame time-resolved MeV gamma diagnostic for experiments on the NIF with sub-nanosecond resolution. A series of experiments demonstrated measurements of MeV x-ray spectra resolved with a time separation of a few nanoseconds through the use of gas Cherenkov detectors. In this work, a two-pulse radiographic experiment found a 30% reduction in > 2.8 MeV photon flux compared to the first frame exposure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Disordered topological graphs enhancing nonlinear phenomena

Complex networks play a fundamental role in understanding phenomena from the collective behavior of spins, neural networks, and power grids to the spread of diseases. Topological phenomena in such networks have recently been exploited to preserve the response of systems in the presence of disorder. We propose and demonstrate topological structurally disordered systems with a modal structure that enhances nonlinear phenomena in the topological channels by inhibiting the ultrafast leakage of energy from edge modes to bulk modes. We present the construction of the graph and show that its dynamics enhances the topologically protected photon pair generation rate by an order of magnitude. Disordered nonlinear topological graphs will enable advanced quantum interconnects, efficient nonlinear sources, and light-based information processing for artificial intelligence.

42 ENGINEERING↗

Systems and methods for spatiotemporal control of a laser and applications of same

Methods and systems are disclosed for using a chromatic lens system to provide a “flying focus”—i.e., an advanced focusing scheme enabling spatiotemporal control of a focal location. In a method, a photon beam is emitted from a source at a wavelength. The photon beam may have more than one wavelength. The photon beam is focused to a focal location using a chromatic lens system. The focal location is at a first longitudinal distance along an optical axis from the chromatic lens system. The wavelength of the photon beam is changed as a function of time to change the focal location as a function of time. The wavelength may be changed such that the focal location changes with a focal velocity.

Froula, Dustin H.↗

Systems and methods for spatiotemporal control of a laser and applications of same

Methods and systems are disclosed for using a chromatic lens system to provide a “flying focus”—i.e., an advanced focusing scheme enabling spatiotemporal control of a focal location. In a method, a photon beam is emitted from a source at a wavelength. The photon beam may have more than one wavelength. The photon beam is focused to a focal location using a chromatic lens system. The focal location is at a first longitudinal distance along an optical axis from the chromatic lens system. The wavelength of the photon beam is changed as a function of time to change the focal location as a function of time. The wavelength may be changed such that the focal location changes with a focal velocity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗