The 23-GEV/C Beam Transfer and Absorber Lines for the Superconducting Super Collider
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
A facility will be built in Padova (Italy) to develop, commission, and optimize the neutral beam injection system for ITER. The full scale prototype negative ion radio frequency source SPIDER, featuring up to 100 kV acceleration voltage, includes a full set of diagnostics, required for safe operation and to measure and optimize the beam performance. Among them, beam emission spectroscopy (BES) will be used to measure the line integrated beam uniformity, divergence, and neutralization losses inside the accelerator (stripping losses). In the absence of the neutralization stage, SPIDER beam is mainly composed by H{sup -} or D{sup -} particles, according to the source filling gas. The capability of a spectroscopic diagnostic of an H{sup -} (D{sup -}) beam relies on the interaction of the beam particles with the background gas particles. The BES diagnostic will be able to acquire the H{sub {alpha}} (D{sub {alpha}}) spectrum from up to 40 lines of sight. The system is capable to resolve stripping losses down to 2 keV and to measure beam divergence with an accuracy of about 10%. The design of this diagnostic is reported, with discussion of the layout and its components, together with simulations of the expected performance.
The charge exchange recombination spectroscopy (CXRS) diagnostics on the T-10 tokamak is described. The system is based on a diagnostic neutral beam and includes three high etendue spectrometers designed for the ITER edge CXRS system. A combined two-channel spectrometer is developed for simultaneous measurements of two beam-induced spectral lines using the same lines of sight. A basic element of the combined spectrometer is a transmitting holographic grating designed for the narrow spectral region 5291 ± 100 Å. The whole CXRS system provides simultaneous measurements of two CXRS impurity spectra and H{sub α} beam line. Ion temperature measurements are routinely provided using the C{sup 6+} CXRS spectral line 5291 Å. Simultaneous measurements of carbon densities and one more impurity (oxygen, helium, lithium etc.) are carried out. Two light collecting systems with 9 lines of sight in each system are used in the diagnostics. Spatial resolution is up to 2.5 cm and temporal resolution of 1 ms is defined by the diagnostic neutral beam diameter and pulse duration, respectively. Experimental results are shown to demonstrate a wide range of the CXRS diagnostic capabilities on T-10 for investigation of impurity transport processes in tokamak plasma. Developed diagnostics provides necessary experimental data for studying of plasma electric fields, heat and particle transport processes, and for investigation of geodesic acoustic modes.
European effort on charge breeders is mainly dedicated to present and future Radioactive Ion Beam facilities. The main projects are High Intensity and Energy-ISOLDE at CERN, SPIRAL2 at GANIL, and EURISOL. Most of the experimental developments are funded by the European programs EURONS (European Nuclear Structure) and EURISOL (European Isotope Separation On-Line Radioactive Ion Beam Facility). Two ion source types (electron beam ion source and electron cyclotron resonance ion source) have been adapted to accept the injection and the capture of an ion beam, in order to increase its charge with the highest efficiency within the shortest time. Both charge breeders have advantages and disadvantages with regard to their use in a Radioactive Ion Beam facility. The most important parameters studied are acceptance (in emittance and intensity) of the charge breeder, efficiency, and charge breeding time of a specific n+ charge state, emittance of the extracted n+ beam. The charge breeder parameters are studied with different 1+ ion sources dedicated to 1+ radioactive ion beam production, and the tuning procedure of the charge breeder as a beam line section of a specific accelerator is established and measured too.
Simulations of slow extraction and transport of charged particle beams from synchrotrons requires careful modeling and experimentation. In this paper, we outline how the Bmad modeling software was adapted and developed to run third-integer resonant extraction simulations of beams at Brookhaven National Laboratory’s Booster synchrotron. Further, we show experimental comparisons of the slowly extracted beams transferred to the NASA Space Radiation Laboratory (NSRL) transport line. In this process, beam passes through a stripping foil element at the extraction point, which, along with stripping remaining electrons from the beam ions, acts as a scatterer to modify the phase space, moving to a more Gaussian-like distribution. This modification to the beam helps generate a uniform beam at the beam line’s target location; which is necessary for the variety of experiments performed at the facility. During this work, beam energy loss and multiple scattering by foil routines were built in conjunction with the Bmad code developers and are now integrated into the software.
We present polarization measurements of the $2{{\rm{p}}}^{5}3{\rm{d}}$ 1 P 1 → 2p 6 1 S 0 resonance line of Ne-like Mo 32+ , commonly known as 3C, as well as the $2{{\rm{p}}}^{5}3{\rm{d}}$ 3 D 1 → 2p 6 1 S 0 intercombination line, commonly known as 3D, as a function of the electron impact energy ranging from near threshold to 6 times threshold (2.75–15 keV). In addition, the x-ray line polarization of the $2{{\rm{p}}}^{5}3{\rm{p}}$ 3 D 2 → 2p 6 1 S 0 electric quadrupole forbidden line was measured at 3 and 4 keV. Excitation of these lines was achieved with the LLNL EBIT-I electron beam ion trap. The degree of polarization of the emission lines was derived by comparing spectra recorded with a flat Ge (111) crystal spectrometer, which is sensitive to polarization, to the spectra recorded by an x-ray calorimeter, which is insensitive to polarization. Here, the experimental measurements were compared to theoretical predictions produced using the Flexible Atomic Code, and good agreement was found.
To enhance the performance of Hefei Light Source, which was designed and constructed two decades ago, an upgrade project would be carried out in the near future. The detail upgrade scheme was described in this paper. Firstly, the magnet lattice of storage ring should be reconstructed with 4 DBA cells, whose advantages are lower beam emittance and more straight section available for insertion devices. Secondly, the beam diagnostics, main power supply, transverse and longitudinal multi-bunch feedback, beam control and manipulation system would be upgrade to improve the beam orbit stability. Finally, the injection system of storage ring and injector, which is composed of electron linac and beam transfer line, would be updated in order to assure smooth beam accumulation process under new low emittance lattice. With above improvement, it is hopeful to increase the brilliance of Hefei Light Source by two orders approximately. After three-year upgrade project, the performance of HLS would meet the demands of advanced SR users.
Extracted ion beams from the test laser ion source (LIS) were transported through a test beam transport line which is almost identical to the actual primary beam transport in the current electron beam ion source apparatus. The tested species were C, Al, Si, Cr, Fe, Cu, Ag, Ta, and Au. The all measured beam currents fulfilled the requirements. However, in the case of light mass ions, the recorded emittance shapes have larger aberrations and the RMS values are higher than 0.06 π mm mrad, which is the design goal. Since we have margin to enhance the beam current, if we then allow some beam losses at the injection point, the number of the single charged ions within the acceptance can be supplied. For heaver ions like Ag, Ta, and Au, the LIS showed very good performance.
Purpose: To propose and validate a craniospinal irradiation approach using a proton pencil beam scanning technique that overcomes the complexity of the planning associated with feathering match lines. Methods and Materials: Ten craniospinal irradiation patients had treatment planned with gradient dose optimization using the proton pencil beam scanning technique. The robustness of the plans was evaluated by shifting the isocenter of each treatment field by ±3 mm in the longitudinal direction and was compared with the original nonshifted plan with metrics of conformity number, homogeneity index, and maximal cord doses. An anthropomorphic phantom study using film measurements was carried out on a plan with 5-cm junction length. To mimic setup errors in the phantom study, fields were recalculated with isocenter shifts of 1, 3, 5, and 10 mm longitudinally, and compared with the original plans and measurements. Results: Uniform dose coverage to the entire target volumes was achieved using the gradient optimization approach with averaged junction lengths of 6.7 ± 0.5 cm. The average conformity number and homogeneity index equaled 0.78 ± 0.03 and 1.09 ± 0.01, respectively. Setup errors of 3 mm per field (6 mm in worst-case scenario) caused on average 4.6% lower conformity number 2.5% higher homogeneity index and maximal cord dose of 4216.1 ± 98.2 cGy. When the junction length was 5 cm or longer, setup errors of 6 mm resulted in up to 12% dosimetric deviation. Consistent results were reached between film measurements and planned dose profiles in the junction area. Conclusions: Longitudinal setup errors directly reduce the dosimetric accuracy of the proton craniospinal irradiation treatment with matched proton pencil beam scanning fields. The reported technique creates a slow dose gradient in the junction area, which makes the treatment more robust to longitudinal setup errors compared to conventional feathering methods.
The current LHC transfer line collimation system will not be able to provide enough protection for the high brightness beams in the high-luminosity LHC era. The new collimation system will have to attenuate more and be more robust than its predecessor. The active jaw length of the new transfer line collimators will therefore be 2.1 m instead of currently 1.2 m. The transfer line optics will have to be adjusted for the new collimator locations and larger beta functions at the collimators for absorber robustness reasons. In this paper the new design of the transfer line collimation system will be presented with its implications on transfer line optics and powering, maintainability, protection of transfer line magnets in case of beam loss on a collimator and protection of the LHC aperture.
This paper describes the dynamics of space charge dominated beam through a Glaser magnet which is often used to focus charged particle beams in the low energy section of accelerators and in many other devices. Various beam optical properties of the magnet and emittance evolution that results from the coupling between the two transverse planes are studied. We have derived ten independent first order differential equations for the beam sigma matrix elements assuming the linear space-charge force consistent with the assumption of the canonically transformed KV like distribution. In addition, the feasibility of using a Glaser magnet doublet in a low energy beam injection line to match an initial non-axisymmetric high intensity beam with net angular momentum to an axisymmetric system to suppress effective emittance growth after transition back to an uncoupled system, has also been studied.
A high peak-power Q-switched laser has been used to monitor the ion beam profiles in the superconducting linac at the Spallation Neutron Source (SNS). The laser beam suffers from position drift due to movement, vibration, or thermal effects on the optical components in the 250-meter long laser beam transport line. We have designed, bench-tested, and implemented a beam position stabilization system by using an Ethernet CMOS camera, computer image processing and analysis, and a piezo-driven mirror platform. The system can respond at frequencies up to 30 Hz with a high position detection accuracy. With the beam stabilization system, we have achieved a laser beam pointing stability within a range of 2 rad (horizontal) to 4 rad (vertical), corresponding to beam drifts of only 0.5 mm 1 mm at the furthest measurement station located 250 meters away from the light source.
Ion-beam etching and masking techniques fabricate micron-sized gold strip lines. Fabricated by use of argon ion-beam milling.
In this paper, the influence of the absorption shot noise on line edge roughness (LER) of photoresists for extreme ultraviolet (EUV) lithography is studied experimentally through the comparative analysis of LER obtained by EUV (92 eV photons) and 100 keV e-beam lithography. Techniques for performing EUV and e-beam lithography with a matched image log slope for a fair comparison of LER values are described. Measurements of absorption of 100 keV electrons estimated through a transmissive electron energy loss spectroscopy measurement with a 120 keV electron beam showed that despite having access to core levels in the material (e.g., 284 eV edge in carbon), these electrons mostly just excite the energy levels less than 100 eV in the resist, with a mean deposited energy of 35 eV. By combining the incident flux and the absorption probabilities, the absorbed quanta for patterning of 50 nm half-pitch line/space features was found to be similar between the two patterning technologies.
A line spread device capable of yielding direct measure of a laser beam's line spread function (LSF) was developed and employed in propagation tests conducted in a wind tunnel to examine optimal acoustical suppression techniques for laser cavities exposed to simulated aircraft aerodynamic environments. Measurements were made on various aerodynamic fences and cavity air injection techniques that effect the LSF of a propagating laser. Using the quiescent tunnel as a control, the relative effect of each technique on laser beam quality was determined. The optical instrument employed enabled the comparison of relative beam intensity for each fence or mass injection. It was found that fence height had little effect on beam quality but fence porosity had a marked effect, i.e., 58% porosity alleviated cavity resonance and degraded the beam the least. Mass injection had little effect on the beam LSF. The use of a direct LSF measuring device proved to be a viable means of determining aerodynamic seeing qualities of flow fields.
This paper presents calculations of detector solenoid effects on disrupted primary beam in the ILC 14 mrad extraction line. Particle tracking simulations are performed for evaluation of primary beam loss along the line as well as of beam distribution and polarization at Compton Interaction Point. The calculations are done both without and with solenoid compensation. The results are obtained for the baseline ILC energy of 500 GeV center-of-mass and three options of beam parameters.
The beta-decay properties of neutron-rich fission fragments of Cu, Zn, and Ga isotopes were studied at the Holifield Radioactive Ion Beam Facility. Beams of 75-79 Cu, 79-81 Zn, and 83-85 Ga were formed and delivered to two new end-stations at the facility. The Low-energy Radioactive Ion Beam Spectroscopy Station is a traditional on-line low energy (200 keV) beam line with 4 clover Ge detectors, two half-cylindrical plastic beta-detectors, and a moving tape collector. In addition, many of the beams were accelerated to above 2 MeV/u and delivered to a micro-channel plate and transmission ion chamber located just in front of the same detector setup. In both cases, fine adjustment of an isobar separator was used to enhance the isotope of interest. Excited levels in the daughters and beta-delayed neutron branching ratios were measured and used to confirm isotope identification. The decays from 79 Cu and 85 Ga were observed for the first time as was the 84 Ge 2 1 + level populated by beta and beta-n decay channels.
Magnetic reconnection events in the corona release energetic electron beams along open field lines, and the beams generate radio emission at multiples of the electron plasma frequency f{sub p} to produce type III solar radio bursts. Type III bursts often exhibit irregularities in the form of flux modulations with frequency and/or local temporal advances and delays, and a type IIIb burst represents the extreme case where a type III burst is fragmented into a chain of narrowband features called striae. Remote and in situ spacecraft measurements have shown that density turbulence is ubiquitous in the corona and solar wind, and often exhibits a Kolmogorov power spectrum. In this work, we numerically investigate the effects of one-dimensional macroscopic density turbulence (along the beam direction) on the behavior of type III bursts, and find that this turbulence produces stria-like fine structures in the dynamic spectra of both f{sub p} and 2 f{sub p} radiation. Spectral and temporal fine structures in the predicted type III emission are produced by variations in the scattering path lengths and group speeds of radio emission, and in the locations and sizes of emitting volumes. Moderate turbulence levels yield flux enhancements with much broader half-power bandwidths in f{sub p} than 2 f{sub p} emission, possibly explaining the often observed type IIIb-III harmonic pairs as being where intensifications in 2 f{sub p} radiation are not resolved observationally. Larger turbulence levels producing trough-peak regions in the plasma density profile may lead to broader, resolvable intensifications in 2 f{sub p} radiation, which may account for the type IIIb-IIIb pairs that are sometimes observed.