Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building performance simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Avoiding symmetry roadblocks and minimizing the measurement overhead of adaptive variational quantum eigensolvers

Quantum simulation of strongly correlated systems is potentially the most feasible useful application of near-term quantum computers. Minimizing quantum computational resources is crucial to achieving this goal. A promising class of algorithms for this purpose consists of variational quantum eigensolvers (VQEs). Among these, problem-tailored versions such as ADAPT-VQE that build variational ansätze step by step from a predefined operator pool perform particularly well in terms of circuit depths and variational parameter counts. However, this improved performance comes at the expense of an additional measurement overhead compared to standard VQEs. Here, we show that this overhead can be reduced to an amount that grows only linearly with the number n of qubits, instead of quartically as in the original ADAPT-VQE. We do this by proving that operator pools of size 2 n − 2 can represent any state in Hilbert space if chosen appropriately. We prove that this is the minimal size of such "complete" pools, discuss their algebraic properties, and present necessary and sufficient conditions for their completeness that allow us to find such pools efficiently. We further show that, if the simulated problem possesses symmetries, then complete pools can fail to yield convergent results, unless the pool is chosen to obey certain symmetry rules. We demonstrate the performance of such symmetry-adapted complete pools by using them in classical simulations of ADAPT-VQE for several strongly correlated molecules. Our findings are relevant for any VQE that uses an ansatz based on Pauli strings.

Shkolnikov, V. O.↗

A Probabilistic Approach to Load Modeling for Central HVAC Systems in Large Commercial Buildings for Retrofit Decisions Under Uncertainty

Retrofitting central HVAC systems in large commercial buildings with advanced technologies like heat recovery chillers (HRCs) offers a significant opportunity to enhance energy efficiency. However, analyzing these retrofits is challenging with traditional whole-building simulation tools, which require intensive calibration and struggle to model innovative system configurations and controls. To overcome these limitations, this study proposes a load profilebased retrofit analysis framework that provides better decisions under uncertainty. The main focus of this paper is the development of a probabilistic load profile model that can be used in the framework by using exploratory data analysis (EDA) of measured building data to properly quantify its inherent variability. A non-parametric Gaussian Process (GP) model was employed to capture the time- and weather-dependent characteristics of the heating load while explicitly modeling its uncertainty. The model's effectiveness is demonstrated through strong predictive performance on unseen data and physically interpretable insights into load behavior. This data-driven, probabilistic load profile serves as a robust and flexible input for subsequent system simulations, enabling a more confident and statistically sound analysis of retrofit potential.

Ham, S W↗

Microreactor Optimization Using Simulation And Economics (mouse)

Microreactor Optimization Using Simulation and Economics (MOUSE) is a tool that integrates both nuclear microreactor design and reactor economics to provide comprehensive evaluations and optimizations. This tool enables stakeholders to explore the interplay between technical and economic variables, guiding them towards effective and competitive microreactor solutions. For the reactor core simulations, MOUSE leverages the OpenMC Monte Carlo Particle Transport Code to perform detailed core simulations for various microreactor designs. The included OpenMC models are 2D core designs of a Liquid Metal Thermal Microreactor (LMTR), a Gas-Cooled TRISO-Fueled Microreactor (GCMR), and a Heat Pipe Microreactor. Beyond core design, MOUSE includes simplified calculations for: - Calculating the masses of heat exchangers within the system. - Mechanical power of pumps. - Estimating the area occupied by various buildings within the nuclear plant. For the economic analysis, MOUSE provides detailed bottom-up cost estimates, encompassing a wide range of costs including preconstruction costs, direct costs, indirect costs, training costs, financial costs, operation & maintenance (O&M) costs, and fuel costs. These cost estimations are developed using data from the MARVEL project and additional literature sources, enabling the calculation of total capital costs and levelized cost of energy for both first-of-a-kind and nth-of-a-kind microreactors. MOUSE also enables analysis of the cost drivers and competitiveness in the electricity market. MOUSE allows users to modify a wide array of technical and economic parameters to evaluate different scenarios and their impacts. Examples of these parameters include: Fuels, coolants, or reflector materials Enrichment levels Control drum materials and geometry Fuel pin geometry and materials Moderator pin geometry and materials Reactor core and reflector dimensions Packing factor for the TRISO particles Nuclear reactor power and reactor burnup Number of sensors Shielding thickness Reactor vessel and guard vessel dimensions Operational staff requirements Number of emergency shutdowns Levelization period Interest rate Construction duration Since MOUSE is powered by the WATTS toolkit, it supports optimization studies, parametric analyses, and uncertainty calculations/propagation. The optimization techniques enable users to identify optimal design and economic configurations. The parametric analysis tools allow users to explore the sensitivity of various parameters, while uncertainty propagation helps quantify the impact of uncertainties on overall performance and cost. User Interface and Workflow: Currently, MOUSE is a command-line-based tool. Users can input various reactor design or economic parameters, modify the designs, run simulations, and visualize results through comprehensive data visualization and reporting capabilities. The typical workflow involves setting up the reactor model, defining economic parameters, running simulations, and analyzing the results to make informed decisions. By combining advanced design calculations with detailed economic modeling, MOUSE provides a robust framework for optimizing nuclear microreactor technologies, enhancing their competitiveness, and guiding stakeholders towards innovative and cost-effective solutions.

Hanna, Botros [Idaho National Laboratory (INL), Id↗

Technical Highlight: NREL Tests Integrated Heat Pump Water Heater Performance in Different Climates (Fact Sheet)

This technical highlight describes NREL tests to capture information about heat pump performance across a wide range of ambient conditions for five heat pump water heaters (HPWH). These water heaters have the potential to significantly reduce water heater energy use relative to traditional electric resistance water heaters. These tests have provided detailed performance data for these appliances, which have been used to evaluate the cost of saved energy as a function of climate. The performance of HPWHs is dependent on ambient air temperature and humidity and the logic controlling the heat pump and the backup resistance heaters. The laboratory tests were designed to measure each unit's performance across a range of air conditions and determine the specific logic controlling the two heat sources, which has a large effect on the comfort of the users and the energy efficiency of the system. Unlike other types of water heaters, HPWHs are both influenced by and have an effect on their surroundings. Since these effects are complex and different for virtually every house and climate region, creating an accurate HPWH model from the data gathered during the laboratory tests was a main goal of the project. Using the results from NREL's laboratory tests, such as the Coefficient of Performance (COP) curves for different air conditions as shown in Figure 1, an existing HPWH model is being modified to produce more accurate whole-house simulations. This will allow the interactions between the HPWH and the home's heating and cooling system to be evaluated in detail, for any climate region. Once these modeling capabilities are in place, a realistic cost-benefit analysis can be performed for a HPWH installation anywhere in the country. An accurate HPWH model will help to quantify the savings associated with installing a HPWH in the place of a standard electric water heater. In most locations, HPWHs are not yet a cost-effective alternative to natural gas water heaters. The detailed system performance maps that were developed by this testing program will be used to: (1) Target regions of the country that would benefit most from this technology; (2) Identify improvements in current systems to maximize homeowner cost savings; and (3) Explore opportunities for development of advanced hot water heating systems.

03 NATURAL GAS↗

Effective Kitchen Ventilation for Healthy Zero Net Energy Homes with Natural Gas

Past studies indicate that kitchen ventilation that minimally complies with California’s Residential Building Code is inadequate at controlling combustion pollutants from natural gas burners and particulate matter produced during cooking. Effectiveness is further limited by misperceptions that kitchen ventilation is infrequently needed. This project developed the technical basis for updating kitchen ventilation requirements to protect health in new California homes, especially in smaller homes common among low-income renters. Tasks included (1) a field study of ventilation equipment performance and indoor air quality in 23 low-income apartments at four sites; (2) analysis of range hood use related to cooking time and household parameters using data from 54 houses and 17 low-income apartments; (3)a measurement-based study to quantify performance of over-the-range microwave ovens with integrated exhaust fans;and (4) pollutant exposure simulations to inform capture efficiency standards.The field study found operational deficiencies with mechanical ventilation systems in a substantial fraction of low-income apartments that affected performance, resulting in higher exposures to pollutants generated indoors. Using gas cooking burners produced high short-term and weekly time-averaged nitrogen dioxide in apartments.Range hoods were used more frequently with cooking in houses (36percent) than apartments (28percent); use increased with overall cooking frequency in a home and with duration of cooktop but not oven events; actual use was correlated to, but lower than,self-reported use;and use was more frequent in houses when cooking generated any fine particulate matter (PM2.5)or when high PM2.5resulted from cooking in apartments. Performance of over-the-range microwaves with integrated exhaust fans was similar to that of range hoods of comparable price. Simulation analysis found that performance standards need to be updated to ensure that kitchen exhaust ventilation adequately protects for substantial cooking in new California residences.

03 NATURAL GAS↗

An automated approach to the alignment of compound refractive lenses

Compound refractive lenses (CRLs) are established X-ray focusing optics, and are used to focus the beam or image the sample in many beamlines at X-ray facilities. While CRLs are quite established, the stack of single lens elements affords a very small numerical aperture because of the thick lens profile, making them far more difficult to align than classical optical lenses that obey the thin-lens approximation. This means that the alignment must be very precise and is highly sensitive to changes to the incident beam, often requiring regular readjustments. Some groups circumvent the full realignment procedure by using engineering controls ( e.g. mounting optics) that sacrifice some of the beam's focusing precision, i.e. spot size, or resolution. While these choices minimize setup time, there are clear disadvantages. This work presents a new automated approach to align CRLs using a simple alignment apparatus that is easy to adapt and install at different types of X-ray experiments or facilities. This approach builds on recent CRL modeling efforts, using an approach based on the Stochastic Nelder–Mead (SNM) simplex method. This method is outlined and its efficacy is demonstrated with numerical simulation that is tested in real experiments conducted at the Advanced Photon Source to confirm its performance with a synchrotron beam. This work provides an opportunity to automate key instrumentation at X-ray facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Residual Stress Modeling and Advanced Diffraction Measurements of 347H Steel Weldments

The 347H stainless steel is a primary high-temperature material for many energy and power generation industries. Stress relief cracking (SRC) has been a particular concern in welding of this material. The residual stress induced by welding and its evolution during post-welding heat treatment (PWHT) and subsequent operating and service conditions is one of the primary factors contributing to SRC. The lifetime of welded structure components is also controlled by the precipitation kinetics that accompanies PWHT, stress relaxation process, and long-term aging and complex synergistic factors. Various theories have been proposed in the past to explain SRC. However, a widely accepted approach to predicting the entire damage evolution and the resulting performance reduction is still lacking. This study is to demonstrate a reliable solution for two critical issues that affect the predictions. First, the residual stress distribution obtained from both simulation and neutron diffraction is compared, which increases the accuracy of mechanical analysis simulation model and therefore builds a solid basis for the lifetime prediction model. Second, the generation, evolution, and annihilation of precipitates are monitored by the synchrotron diffraction experiment. Preliminary results demonstrate the critical importance of precipitation kinetics on the residual stress distribution/redistribution during heat treatments.

Yang, Yi↗

Heat Pumps with Phase Change Thermal Storage: Flexible, Efficient, and Electrification Friendly

As we continue to electrify space- and water-heating, the electricity demand profile of many buildings will change significantly, and periods of high electricity demand will likely not align with renewable energy generation. We expect electricity demands will increase substantially in the winter, annual maximum electricity demands will increase, and more regions will experience annual peak electrical demands – and higher wholesale electricity prices – in the winter. This is especially important for cold climates where 60% of site energy use in buildings is for heating, and where heat pumps perform least efficiently. This paper focuses on one promising solution among the many paths to electrification: the use of phase change materials (PCM) for compact low-cost thermal energy storage (TES). We present the design and simulation of a combi heat pump and phase change thermal storage system used for space- and water-heating in a multifamily residence in a cold climate. To assess the benefits of this technology, we compare its annual performance to that of a current state-of-the-art air-to-air heat pump and separate heat pump water heater. Simulation results for IECC Climate Zone 6A reveal that the combi heat pump with phase change thermal storage can reduce the design size for heat pumps by 40-60%, reduce maximum electric demand by 30-50%, reduce electricity use during 4-12-hour load shed periods by 50%, and avoid the need for auxiliary electric resistance for both space- and water-heating. Tariff structures are highly varied between different utilities and currently reflect higher wholesale market prices for electricity during summer days. Consequently, although this system design provides large electric demand reductions during hypothetical 4-12-hour load shed periods, it does not provide energy cost reductions with current winter residential time-of-use tariffs.

Helmns, Dre↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Solar-Reflective “Cool” Walls: Benefits, Technologies, and Implementation

Raising the albedo (solar reflectance) of a building’s walls reduces unwanted solar heat gain in the cooling season. This saves electricity and lowers peak power demand by decreasing the need for air conditioning. It can also cool the outside air, which can mitigate the urban heat island effect and also improve air quality by slowing the reactions that produce smog. This project quantified the energy savings, peak demand reduction, urban cooling, and air quality improvements attainable from solar-reflective “cool” walls in California; collaborated with industry to assess the performance of existing cool-wall technologies, and to develop innovative cool-wall solutions; and worked with state and federal government agencies, utilities, and industry to create a cool-wall infrastructure, including application guidelines, a product rating program, incentives, and building code credits. Simulations indicate that cool walls provide annual energy savings, peak demand reduction, annual emission reduction, and summer heat island mitigation benefits comparable to those yielded by cool roofs, and are helpful across California and in most of the southern half of the United States (that is, in U.S. climate zones 1—4). Natural exposure trials conducted at three sites in California and another three sites across the United States indicate that cool-wall materials tend to stay clean and reflective. Significant advances were made in novel cool-wall technologies, such as fluorescent cool pigments that expand the color palette for cool-wall products. We prepared guidelines for the climate- and building-appropriate use of cool walls, convened a stakeholder workshop, and created a working group. Ongoing efforts seek to introduce or expand cool-wall provisions in building energy standards, green building programs, and energy efficiency incentive programs, and to develop a cool-wall product rating system.

utility incentives↗

Improving Monsoon Precipitation Prediction Using Combined Convolutional and Long Short Term Memory Neural Network

Precipitation downscaling is widely employed for enhancing the resolution and accuracy of precipitation products from general circulation models (GCMs). In this study, we propose a novel statistical downscaling method to foster GCMs’ precipitation prediction resolution and accuracy for the monsoon region. We develop a deep neural network composed of a convolution and Long Short Term Memory (LSTM) recurrent module to estimate precipitation based on well-resolved atmospheric dynamical fields. The proposed model is compared against the GCM precipitation product and classical downscaling methods in the Xiangjiang River Basin in South China. Results show considerable improvement compared to the European Centre for Medium-Range Weather Forecasts (ECMWF)-Interim reanalysis precipitation. Also, the model outperforms benchmark downscaling approaches, including (1) quantile mapping, (2) the support vector machine, and (3) the convolutional neural network. To test the robustness of the model and its applicability in practical forecasting, we apply the trained network for precipitation prediction forced by retrospective forecasts from the ECMWF model. Compared to the ECMWF precipitation forecast, our model makes better use of the resolved dynamical field for more accurate precipitation prediction at lead times from 1 day up to 2 weeks. This superiority decreases with the forecast lead time, as the GCM’s skill in predicting atmospheric dynamics is diminished by the chaotic effect. Finally, we build a distributed hydrological model and force it with different sources of precipitation inputs. Hydrological simulation forced with the neural network precipitation estimation shows significant advantage over simulation forced with the original ERA-Interim precipitation (with NSE value increases from 0.06 to 0.64), and the performance is only slightly worse than the observed precipitation forced simulation (NSE = 0.82). This further proves the value of the proposed downscaling method, and suggests its potential for hydrological forecasts.

54 ENVIRONMENTAL SCIENCES↗

Lifting the Garage Door on Spawn, An Open-Source BEM-Controls Engine

Spawn is the latest whole-building energy simulation engine developed by the US Department of Energy, National Labs and industry. Whereas EnergyPlus was designed as a successor to DOE-2, Spawn is not a direct successor of–nor is it intended as an imminent replacement for– EnergyPlus. Instead, Spawn reuses parts of EnergyPlus while supporting new use cases in HVAC and controls. Spawn is intended to provide several capabilities that significantly advance beyond EnergyPlus. It is intended to support the evaluation of novel HVAC and district energy systems in a more physically realistic way. Critically, it can model control in a physically realistic way, using portable specifications that can be compiled for execution on control platforms. Spawn is also intended to support co-simulation in an intrinsic way to enable integration with third-party models. This paper describes the software architecture of Spawn from model authoring to compilation and simulation. It explains how Spawn reuses the envelope and daylighting modules of EnergyPlus and couples them to HVAC and control models from the Modelica Buildings Library using the Functional Mockup Interface (FMI) standard. It presents a number of examples that: i) validate Spawn’s coupled simulation approach by comparing its results to those of EnergyPlus, ii) illustrate the Spawn methodology for modeling and simulating HVAC systems, and iii) evaluate the performance of Spawn’s Quantized State System (QSS) time integration algorithms

Wetter, Michael↗

Beam-Based Target Alignment for Mu2e

The Mu2e Experiment is a precision experiment at Fermi National Accelerator Laboratory, searching for charged lepton flavor violation (CLFV) in the conversion of a muon to an electron in the presence of an atomic nucleus. In order to achieve the expected single-event sensitivity of $3\times 10^{-17}$ , Mu2e will require an intense muon beam, generated via pion decay. These pions are the product of a proton beam striking a radiatively-cooled tungsten target. In order to maximize pion production and prevent target failure, the beam will have to be aligned with the target center to within 0.5 mm. The production target monitor (PTM) will ensure this alignment. The PTM consists of a series of proportional wire chambers (PWC’s) upstream and downstream of the production target. In this dissertation, I explain the requirements of this detector system and derive the decisions about which detector model to use and how they should be arranged from these requirements. After this, I describe my e xperience building the detectors and show an early use for them in the Mu2e proton beam. I also performed a study of the sensitivity and time resolution of this model of PWC and its electronics, and give the results here. I then describe a series of simulation campaigns which shed light on the interactions between the beam and the target, and how these interactions manifest on the downstream detectors. Finally, I give the target scanning procedure to be used to align the beam and target during experiment start up.

43 PARTICLE ACCELERATORS↗

Dynamic Building Load Control to Facilitate High Penetration of Solar Photovoltaic Generation (Final Technical Report)

Solar photovoltaic (PV) resources are the most common form of distributed generation in residential and commercial customer premises within electric distribution networks. A higher penetration of PV generation in distribution circuits will impose challenges on maintaining service voltages within the range of industry standards, power quality, and power flow. Buildings consume 74% of the electricity produced in the United States, and a significant portion of the building load is dispatchable, making them responsive to electrical grid needs. Oak Ridge National Laboratory—in collaboration with Southern Company; the University of Tennessee, Knoxville; and the Georgia Institute of Technology—is examining the PV integration issues in distribution-level electrical grids and developing integrated demand-side control and communication systems to enable responsive loads. The proposed responsive loads mechanism performs renewable generation following to increase the penetration of solar PV within each feeder. The specific objectives of this project are to (1) examine distribution-level PV integration scenarios to understand requirements, (2) undertake an end-to-end simulation-based design of a distributed control strategy of loads geographically near the PV generation asset to minimize the effect on the distribution feeder, (3) deploy and demonstrate the control technology developed in partnership with utilities, and (4) perform a scalability analysis at the utility scale. This 3-year integrated project aims to develop, demonstrate, and validate demand-side control technology to enable increased the penetration of renewables while mitigating challenges that arise due to their intermittency. Activities in Budget Period (BP) 1 focused on a literature review and the formal design of a control system for integrating local distribution with generation and loads. The team used modeling and simulation to evaluate the impact of varying buildings loads, variable PV generation, and power flow dynamics on the distribution circuit. The dynamic models developed in BP 1 were used in BP 2 to develop a model-based control design and a test bed. The test bed has enabled the simulation-based testing and comparison of different control designs and formulations applied to different configurations of the distribution grid, PVs, and building loads. The control approaches developed in BP 2 were implemented in BP 3 in the form of hardware deployed at the Central Baptist Church (CBC) in Knoxville, Tennessee, for testing and evaluation. The outcome of this project was the development and demonstration of open-source, low-cost, low-touch sensing and control retrofits to distributed PV generation and building loads that, in a coordinated fashion, provide the load-shaping response needed to integrate high levels of renewable penetration. This research addresses the target metrics by dynamically controlling a load with solar generation variability to minimize the extent of two-way power flow, enhance reliability, facilitate high PV penetration (>100% of peak load in a line segment), and generate scalable software and hardware solutions adaptable to any penetration levels. The research and development activities are focused and designed to be impactful within the relevant 2020 targets time frame.An accurate open-source integration simulation framework for end-to-end control design was developed and deployed at the CBC facility for testing and evaluation. This final report provides a detailed review of the technical results achieved during this 3-year integrated project. A novel spectral analysis of PV data is demonstrated to derive the requirements of the control design. A detailed simulation-based analysis of PV integration at increasing penetration levels is presented using 1 year of PV data to demonstrate the impact on the distribution circuits. Two different control strategies were developed and demonstrated via simulation to track variable PV generation with adaptive load dispatch. The report concludes with a summary of accomplishments and recommendations for a path forward.

14 SOLAR ENERGY↗

Data Assimilation Tools for CO2 Reservoir Model Development – A Review of Key Data Types, Analyses, and Selected Software

Pacific Northwest National Laboratory (PNNL) has embarked on an initiative to develop world-class capabilities for performing experimental and computational analyses associated with geologic sequestration of carbon dioxide. The ultimate goal of this initiative is to provide science-based solutions for helping to mitigate the adverse effects of greenhouse gas emissions. This Laboratory-Directed Research and Development (LDRD) initiative currently has two primary focus areas—advanced experimental methods and computational analysis. The experimental methods focus area involves the development of new experimental capabilities, supported in part by the U.S. Department of Energy’s (DOE) Environmental Molecular Science Laboratory (EMSL) housed at PNNL, for quantifying mineral reaction kinetics with CO2 under high temperature and pressure (supercritical) conditions. The computational analysis focus area involves numerical simulation of coupled, multi-scale processes associated with CO2 sequestration in geologic media, and the development of software to facilitate building and parameterizing conceptual and numerical models of subsurface reservoirs that represent geologic repositories for injected CO2. This report describes work in support of the computational analysis focus area. The computational analysis focus area currently consists of several collaborative research projects. These are all geared towards the development and application of conceptual and numerical models for geologic sequestration of CO2. The software being developed for this focus area is referred to as the Geologic Sequestration Software Suite or GS3. A wiki-based software framework is being developed to support GS3. This report summarizes work performed in FY09 on one of the LDRD projects in the computational analysis focus area. The title of this project is Data Assimilation Tools for CO2 Reservoir Model Development. Some key objectives of this project in FY09 were to assess the current state-of-the-art in reservoir model development, the data types and analyses that need to be performed in order to develop and parameterize credible and robust reservoir simulation models, and to review existing software that is applicable to these analyses. This report describes this effort and highlights areas in which additional software development, wiki application extensions, or related GS3 infrastructure development may be warranted.

54 ENVIRONMENTAL SCIENCES↗

Fast and self-learning indoor airflow simulation based on in situ adaptive tabulation

Fast simulation for stratified indoor airflow distributions is desired for various applications, such as design of advanced indoor environments, emergency management, and coupled annual energy simulation for buildings with stratified air distributions. Reduced order models trained by pre-computed computational fluid dynamics results are fast, but their prediction may be inaccurate when applied for conditions outside the training domain. To overcome this limitation, we propose in this paper a fast and self-learning model based on an in situ adaptive tabulation (ISAT) algorithm, which is trained by a fast fluid dynamics (FFD) model as an example. The idea is that the ISAT will retrieve the solutions from an existing data set if the estimated prediction error is within a pre-defined tolerance. Otherwise, the ISAT will execute the FFD simulation, which is accelerated by running in parallel on a graphics processing unit, for a full-scale simulation. This paper systematically investigates the feasibility of the ISAT for indoor airflow simulations by presenting the ISAT-FFD implementation alongside results related to its overall performance. Using a stratified indoor airflow as an example, we evaluated how the training time of ISAT was impacted by four factors (training methods, error tolerances, number of inputs, and number of outputs). Then we demonstrated that a trained ISAT model can predict the key information for inputs both inside and outside the training domain. The ISAT was able to answer query points both inside and close to training domain using retrieve actions within a time less than 0.001 s for each query. In conclusion, we provided suggestions for using the ISAT for building applications.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Ten new predicted covalent organic frameworks with strong optical response in the visible and near infrared

We use density functional theory to predict and evaluate 10 novel covalent organic frameworks (COFs), labeled (X{sub 4}Y)(BDC){sub 3}, (X = C/Si; Y = C, Si, Ge, Sn, and Pb), with topology based on metal organic framework isoreticular metal-organic framework (IRMOF-1), but with new elements substituted for the corner atoms. We show that these new materials are stable structures using frequency calculations. For two structures, (C{sub 4}C and Si{sub 4}C) molecular dynamics simulations were performed to demonstrate stability of the systems up to 600 K for 10 ps. This demonstrates the remarkable stability of these systems, some of which may be experimentally accessible. For the C{sub 4}C material, we also explored the stability of isolated corners and linkers and vacuum and started to build the structure from these pieces. We discuss the equilibrium lattice parameters, formation enthalpies, electronic structures, chemical bonding, and mechanical and optical properties. The predicted bulk moduli of these COFs range from 18.9 to 23.9 GPa, larger than that of IRMOF-1 (ca. 15.4 GPa), and larger than many existing 3D COF materials. The band gaps range from 1.5 to 2.1 eV, corresponding to 600–830 nm wavelength (orange through near infrared). The negative values of the formation enthalpy suggest that they are stable and should be experimentally accessible under suitable conditions. Seven materials distort the crystal structure to a lower space group symmetry Fm-3, while three materials maintain the original Fm-3m space group symmetry. All of the new materials are highly luminescent. We hope that this work will inspire efforts for experimental synthesis of these new materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes

This meeting was held on October 16, 2012, in Westford, MA, and brought together experts in the field of residential humidity control to address modeling issues for dehumidification. The presentations and discussions centered on computer simulation and field experience with these systems, with the goal of developing foundational information to support the development of a Building America Measure Guideline on this topic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗