Search NASA⌕ Search

SEARCH · Search NASA

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Combined iterative reconstruction and image-domain decomposition for dual energy CT using total-variation regularization

Purpose: Dual-energy CT (DECT) is being increasingly used for its capability of material decomposition and energy-selective imaging. A generic problem of DECT, however, is that the decomposition process is unstable in the sense that the relative magnitude of decomposed signals is reduced due to signal cancellation while the image noise is accumulating from the two CT images of independent scans. Direct image decomposition, therefore, leads to severe degradation of signal-to-noise ratio on the resultant images. Existing noise suppression techniques are typically implemented in DECT with the procedures of reconstruction and decomposition performed independently, which do not explore the statistical properties of decomposed images during the reconstruction for noise reduction. In this work, the authors propose an iterative approach that combines the reconstruction and the signal decomposition procedures to minimize the DECT image noise without noticeable loss of resolution. Methods: The proposed algorithm is formulated as an optimization problem, which balances the data fidelity and total variation of decomposed images in one framework, and the decomposition step is carried out iteratively together with reconstruction. The noise in the CT images from the proposed algorithm becomes well correlated even though the noise of the raw projections is independent on the two CT scans. Due to this feature, the proposed algorithm avoids noise accumulation during the decomposition process. The authors evaluate the method performance on noise suppression and spatial resolution using phantom studies and compare the algorithm with conventional denoising approaches as well as combined iterative reconstruction methods with different forms of regularization. Results: On the Catphan©600 phantom, the proposed method outperforms the existing denoising methods on preserving spatial resolution at the same level of noise suppression, i.e., a reduction of noise standard deviation by one order of magnitude. This improvement is mainly attributed to the high noise correlation in the CT images reconstructed by the proposed algorithm. Iterative reconstruction using different regularization, including quadratic orq-generalized Gaussian Markov random field regularization, achieves similar noise suppression from high noise correlation. However, the proposed TV regularization obtains a better edge preserving performance. Studies of electron density measurement also show that our method reduces the average estimation error from 9.5% to 7.1%. On the anthropomorphic head phantom, the proposed method suppresses the noise standard deviation of the decomposed images by a factor of ∼14 without blurring the fine structures in the sinus area. Conclusions: The authors propose a practical method for DECT imaging reconstruction, which combines the image reconstruction and material decomposition into one optimization framework. Compared to the existing approaches, our method achieves a superior performance on DECT imaging with respect to decomposition accuracy, noise reduction, and spatial resolution.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-207-06: Clinical Validations of Shading Correction for Cone-Beam CT Using Planning CT as a Prior

Purpose: Current cone-beam CT (CBCT) images contain severe shading artifacts mainly due to scatter, hindering their quantitative use in current radiation therapy. We have previously proposed an effective shading correction method for CBCT using planning CT (pCT) as prior knowledge. In this work, we investigate the method robustness via statistical analyses on studies of a large patient group and compare the performance with that of a state-of-the-art method implemented on the current commercial radiation therapy machine -- the Varian Truebeam system. Methods: Since radiotherapy patients routinely undergo multiple-detector CT (MDCT) scans in the planning procedure, we use the high-quality pCT as “free” prior knowledge for CBCT image improvement. The CBCT image with no correction is first spatially registered with the pCT. Primary CBCT projections are estimated via forward projections of the registered image. The low frequency errors in the projections, which stem from mainly scatter, are estimated by filtering the difference between original line integral and the estimated scatter projections. The corrected CBCT image is then reconstructed from the scatter corrected projections. The proposed method is evaluated on 40 cancer patients. Results: On all patient images, we compare errors on CT number, spatial non-uniformity (SNU) and image contrast, using pCT as the ground truth. T-tests show that our algorithm improves over the Varian method on CBCT accuracies of CT number and SNU with 90% confident. The average CT number error is reduced from 54.8 HU on the Varian method to 40.9 HU, and the SNU error is reduced from 7.7% to 3.8%. There is no obvious improvement on image contrast. Conclusion: Large-group patient studies show that the proposed pCT-based algorithm outperforms the Varian method of the Truebeam system on CBCT shading correction, by providing CBCT images with higher CT number accuracy and greater image uniformity.

60 APPLIED LIFE SCIENCES↗

SU-E-T-407: Evaluation of the Stopping Power and Imaging Visibility for Iodine Based Contrast in Proton Therapy

Purpose: The purpose of this study was to investigate the difference between calculated and measured relative linear stopping power (RLSP) for contrast medium in proton therapy. Furthermore, the visibility for different concentrations in prostate phantom on orthogonal X-ray system was evaluated Methods and Materials: In prostate cancer patient, rectal balloon along with the contrast media was used to visualize the balloon position, thus facilitating the patient setup during each fraction of the uniform scanning proton treatment. There were no fiducial markers implanted in the prostate for this patient. A blue wax phantom with outer dimensions 10cm(H) x 14.5cm(L) x 10cm(W) was made in house. To hold iodine based contrast solution, a rectangular shaped hole with dimensions 7cm(H) x 8cm(L) x 4cm(W) was made inside the phantom. Organically bound 8.5% iodine based Cystografin Dilute contrast agent with molecular formula C11H9I3N2O4.C7H17NO5 was used in this study. Six solutions were prepared; each mixture of water and iodine based contrast agent at different concentrations as 0%, 5%, 10%, 20%, 30% and 50%. During computed tomographic(CT) simulation, solutions were placed together at the isocenter of CT and scanned at 120kVp using the same protocol as for prostate cancer patients. The treatment planning was done in CMS-XiO system. Multi-layer-ion-chamber (MLIC) was used to measure residual proton range. Results: The 50% concentration contrast solution was used during treatment for better visualization on orthogonal X-ray image. The measured RLSP for 5%, 10%, 20%, 30% & 50% solutions were 1.005, 1.010, 1.018, 1.023 & 1.033; and similarly calculated RLSP from XiO were 1.090, 1.135, 1.222, 1.299 & 1.448 respectively. Conclusion: The treatment planning system could overestimates the relative stopping power of contrast solution with high concentrations. It is recommended to override the contrast with measured RLSP for high atomic number based contrast solution in treatment planning for proton therapy.

60 APPLIED LIFE SCIENCES↗

SU-G-206-01: A Fully Automated CT Tool to Facilitate Phantom Image QA for Quantitative Imaging in Clinical Trials

Purpose: The use of Quantitative Imaging (QI) methods in Clinical Trials requires both verification of adherence to a specified protocol and an assessment of scanner performance under that protocol, which are currently accomplished manually. This work introduces automated phantom identification and image QA measure extraction towards a fully-automated CT phantom QA system to perform these functions and facilitate the use of Quantitative Imaging methods in clinical trials. Methods: This study used a retrospective cohort of CT phantom scans from existing clinical trial protocols - totaling 84 phantoms, across 3 phantom types using various scanners and protocols. The QA system identifies the input phantom scan through an ensemble of threshold-based classifiers. Each classifier - corresponding to a phantom type - contains a template slice, which is compared to the input scan on a slice-by-slice basis, resulting in slice-wise similarity metric values for each slice compared. Pre-trained thresholds (established from a training set of phantom images matching the template type) are used to filter the similarity distribution, and the slice with the most optimal local mean similarity, with local neighboring slices meeting the threshold requirement, is chosen as the classifier’s matched slice (if it existed). The classifier with the matched slice possessing the most optimal local mean similarity is then chosen as the ensemble’s best matching slice. If the best matching slice exists, image QA algorithm and ROIs corresponding to the matching classifier extracted the image QA measures. Results: Automated phantom identification performed with 84.5% accuracy and 88.8% sensitivity on 84 phantoms. Automated image quality measurements (following standard protocol) on identified water phantoms (n=35) matched user QA decisions with 100% accuracy. Conclusion: We provide a fullyautomated CT phantom QA system consistent with manual QA performance. Further work will include parallel component to automatically verify image acquisition parameters and automated adherence to specifications. Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics; NIH Grant support from: U01 CA181156.

60 APPLIED LIFE SCIENCES↗

Investigation of Computational Corrections to X-Ray Computed Tomography for Dimensional Metrology of Complex Additively Manufactured Parts

X-ray computed tomography (CT) is a nondestructive evaluation technique that may be used to image complex internal features without the line-of-sight restrictions inherent in conventional optical and contact (stylus) metrology instrumentation. Applications of CT metrology include material defects (porosity), dimensions and surface texture. However, scan artifacts, such as streaking, caused primarily by beam hardening and scatter, limit the accuracy of CTbased metrology. Reduction of these artifacts would improve the accuracy material properties and dimensional metrology information. This paper reports on the development of additively manufactured (AM) Ti5553 and 316L measurement phantoms with integral lattice (lattice) structures specifically designed to exhibit these artifacts. The phantoms were scanned in three CT systems and a scanning-probe CMM measurement. Surfaces generated from uncorrected CT data exhibited “dimple” defects that are not present in the CMM measurement. Correction methods were developed in Livermore Tomography Tools (LTT) software and this paper reports on the successful correction of these artifacts. This work is expected to have application in areas where characterization of defects, dimensions and surface texture using CT are critical.

42 ENGINEERING↗

Assessment of Dynamic Fracture in Ultra-High Performance Concrete Using Synchrotron X-ray Source

Ultra-high-performance concretes (UHPCs) retain higher ultimate (compressive) strengths and greater durability relative to traditional concrete materials. As a result, they are enabling construction materials for blast resistant structures, where a higher capacity for energy absorption is required. In past investigations, the strength of UHPCs was shown to retain a dependency on strain rate. Still, the failure mechanisms which govern this rate dependency have yet to be completely elucidated. In the current study, the dynamic fracture behavior of Cor-tuf UHPC was assessed, in-situ, using a Synchrotron X-ray source in phase contrast imaging (PCI) mode. Prior to testing, the material’s morphology was characterized using X-ray computed tomography (CT) and scanning electron microscopy (SEM). A polychromatic pulsed X-ray source, high-speed camera and Kolsky bar apparatus were used in tandem, to observe the transient failure modes. A pin was placed at the end of the incident bar to control the location of damage initiation, and tests were performed at a constant velocity of ~6 m/s. These test conditions were observed to yield cracks with median and/or cone like geometries. Despite the variation in the crack paths, a significant difference in peak load was not observed. The failure mode was also observed to depend on the microstructure of the concrete samples.

Kolsky bar↗

SU-E-T-325: Dosimetric Impact Due to FlexiShield in Electronic Brachytherapy (eBx) of Breast IORT: A Phantom Study

Purpose: To evaluate dosimetric change of eBx plan due to Flexishield. Methods: To simulate a clinically difficult case (skin spacing < 1 cm and touching chest wall), prostheses breast tissue phantom overlaid Xoft spherical balloon applicator. To minimize significant metal streak artifact, megavoltage CT (MVCT) scan was acquired using helical TomoTherapy HiART. Two sets of MVCT images were taken with/without FlexiShield for 15 cases: 4 for small (3–4 cm), 4 for medium (4–5 cm) and 7 for large (5–6 cm) balloon. Total 30 MVCT scans were obtained with 50 % contrast to improve image contrast of balloon relative to breast tissue phantom. Balloon deformation was measured in anterior-posterior (AP) and lateral (LAT) dimensions in the middle of balloon. Skin spacing was also evaluated. Treatment plan was made based on each MVCT scan and two balloon surface doses (AP and LAT directions) and skin dose were compared between plans with/without FlexiShield. Results: The balloon was deformed due to pressure from both FlexiShield (skin side) and FlexiShield mini (chest wall side). Mean ± standard deviation (maximum) value was 1.5 ± 1.0 mm (3.3 mm) for AP compression and 0.4 ± 0.3 mm (1.1 mm) for LAT expansion. Balloon surface dose was increased by 1.8 ± 1.2 Gy (4.9 Gy) at AP point and decreased by 0.4 ± 0.4 Gy (1.3 Gy) at LAT point. Skin spacing was constantly reduced by 1.1 ± 0.8 mm (3 mm). Skin surface dose was increased by 1.5 ± 0.8 Gy (3.3 Gy) and its relative increase was 17.9 ± 9.3% (39.6%). Conclusion: FlexiShield deforms the balloon and reduces skin spacing, thereby resulting in higher dose in AP direction, lower dose in LAT direction, and elevated skin dose compared to the plan without FlexiShield. In the clinic, this balloon deformation and corresponding dose variation should be considered.

60 APPLIED LIFE SCIENCES↗

Neurosensory and Sinus Evolution as Tyrannosauroid Dinosaurs Developed Giant Size: Insight from the Endocranial Anatomy of Bistahieversor sealeyi

Tyrannosaurus rex and other tyrannosaurid dinosaurs were apex predators during the latest Cretaceous, which combined giant size and advanced neurosensory systems. Computed tomography (CT) data have shown that tyrannosaurids had a trademark system of a large brain, large olfactory bulbs, elongate cochlear ducts, and expansive endocranial sinuses surrounding the brain and sense organs. Older, smaller tyrannosauroid relatives of tyrannosaurids developed some, but not all, of these features, raising the hypothesis that tyrannosaurid-style brains evolved before the enlarged tyrannosaurid-style sinuses, which might have developed only with large body size. This has been difficult to test, however, because little is known about the brains and sinuses of the first large-bodied tyrannosauroids, which evolved prior to Tyrannosauridae. Here we present the first CT data for one of these species, Bistahieversor sealeyi from New Mexico. Bistahieversor had a nearly identical brain and sinus system as tyrannosaurids like Tyrannosaurus, including a large brain, large olfactory bulbs, reduced cerebral hemispheres, and optic lobes, a small tab-like flocculus, long and straight cochlear ducts, and voluminous sinuses that include a supraocciptal recess, subcondyar sinus, and an anterior tympanic recess that exits the braincase via a prootic fossa. When characters are plotted onto tyrannosauroid phylogeny, there is a two-stage sequence in which features of the tyrannosaurid-style brain evolved first (in smaller, nontyrannosaurid species like Timurlengia), followed by features of the tyrannosaurid-style sinuses (in the first large-bodied nontyrannosaurid tyrannosauroids like Bistahieversor). This suggests that the signature tyrannosaurid sinus system evolved in concert with large size, whereas the brain did not.

59 BASIC BIOLOGICAL SCIENCES↗

Percutaneous Cryotherapy for Treatment of Chondroblastoma: Early Experience

Surgical curettage is currently the standard of care for the chondroblastoma, but in peri-articular tumors it is limited by its morbidity. In this preliminary report, we evaluate the feasibility of percutaneous cryotherapy as an alternative ablative treatment for chondroblastoma. Three patients with a chondroblastoma treated by CT scan-guided cryotherapy are presented in this article. Pain permanently disappeared 2 days after the procedure. No local tumor recurrence or cartilage damage was observed by MRI performed 1 year after the intervention. This preliminary case report suggests that percutaneous cryotherapy may be a possible alternative to the current standard of care in chondroblastoma. Further studies are needed to evaluate if this technique offers similar anti-tumoral efficacy while providing better pain relief and less morbidity than curettage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Investigation of dynamic fracture behavior of additively manufactured Al-10Si-Mg using high-speed synchrotron X-ray imaging

The dynamic tensile properties of additively manufactured (AM) and cast Al-10Si-Mg alloy were disccused using high-speed synchrotron X-ray imaging coupled with a modified Kolsky bar apparatus. A controlled tensile loading (strain rate &approx; 750 s -1 ) was applied using the Kolsky bar apparatus and the deformation and fracture behavior were recorded using the high-speed X-ray imaging setup. The CT and high-speed imaging results worked together to identify the location of the critical flaw and to capture the dynamics of crack propagation. In all experiments, the critical flaw was located on the surface of each specimen. The AM specimens displayed significantly higher crack propagation speed, yield strength, ultimate tensile strength, strain hardening coefficient, and yet lower ductility compared to the cast specimens under dynamic tension. Although the strength values were higher for the AM specimens, the critical mode I stress intensity factors were comparable for both specimens. The microstructures of the samples were characterized by synchrotron X-ray computed tomography (CT) and scanning electron microcopy. The correlation between the dynamic fracture behavior of the samples and the microstructure of the samples is analyzed and discussed.

36 MATERIALS SCIENCE↗

A machine learning approach to determine the elastic properties of printed fiber-reinforced polymers

This work focuses on the simultaneous determination of the elastic constants and the fiber orientation state for a short fiber-reinforced polymer composite by performing a minimum of experimental tests. Here we introduce a methodology that enables the inverse determination of fiber orientation state and the in-situ polymer properties by performing tensile tests at the composite coupon level. We demonstrate the approach for the extrusion deposition additive manufacturing (EDAM) process to illustrate one application of the methodology, but the development is such that it can be applied to short fiber-reinforced polymer (SFRP) systems processed via other methods. Currently, developing composites additive manufacturing digital twins require extensive material characterization. In particular, the mechanical characterization of the orthotropic elastic properties of a composite involves extensive sample preparation and testing, therefore the elasticity tensor is generally populated using a micromechanics model. This, however, requires measuring the fiber orientation state in addition to knowing the constituent material properties. Experimentally measuring the fiber orientation state can be tedious and time consuming. Further, optical methods are limited to resolving the orientation of cylindrical fibers or cluster of non-cylindrical fibers, and computed tomography (CT) methods scan regions of volume that are much smaller than a full printed bead. Therefore, we propose a methodology, accelerated by machine learning, to identify the anisotropic mechanical properties and fiber orientation state at the same time. Early results show that inference of the fiber orientation and composite properties is possible with as few as three tensile tests. Our results show that a combination of the choice of the micromechanics model and reliable set of experiments can yield the nine elastic constants, as well as, the fiber orientation state.

36 MATERIALS SCIENCE↗

Modeling of multi-component precipitation and crystallization for zero-liquid-discharge desalination

This study proposes novel ZLD treatment trains that integrate multi-component chemical precipitation and multi-effect evaporative crystallization for efficient brine management. The methodology emphasizes sustainability by integrating CO₂ for chemical precipitation and reducing environmental impact, exemplified with two case studies: produced water that includes industrial waste heat utilization by adopting the emerging vacuum air-gapped membrane distillation (VAGMD) technology, and brackish groundwater that is abundant in sulphate which undergoes treatment by low-salt-rejection reverse osmosis (LSRRO) with interstage chemical precipitation. Here, this study is the first of its kind to simultaneously account for reducing risk of mineral scaling and effective recovery of valuable solids when incorporating VAGMD and LSRRO in ZLD treatment trains. Using Reaktoro and WaterTAP, both Python-based, open-source platforms, we model the recovery of high-purity magnesium, calcium, and sodium salts while optimizing energy consumption and operational efficiency in proposed ZLD pathways for case studies of produced water and brackish desalination brine management. Validation with experimental and reference data confirms the reliability of the models used. In both case studies, the optimized ZLD process achieves recovery rates of 97%, 99%, and 90% for Mg, Ca, and Na, with purities exceeding 99%, and brine volume reduced to less than 4% of the initial feed flow.

3D CT scans↗

Validating the RTOG-Endorsed Brachial Plexus Contouring Atlas: An Evaluation of Reproducibility Among Patients Treated by Intensity-Modulated Radiotherapy for Head-and-Neck Cancer

Purpose: To evaluate interobserver variability for contouring the brachial plexus as an organ-at-risk (OAR) and to analyze its potential dosimetric consequences in patients treated with intensity-modulated radiotherapy (IMRT) for head-and-neck cancer. Methods and Materials: Using the Radiation Therapy Oncology Group (RTOG)-endorsed brachial plexus contouring atlas, three radiation oncologists independently delineated the OAR on treatment planning computed-tomography (CT) axial scans from 5 representative patients undergoing IMRT to a prescribed dose of 70 Gy for head-and-neck cancer. Dose-volume histograms for the brachial plexus were calculated, and interobserver differences were quantified by comparing various dosimetric statistics. Qualitative analysis was performed by visually assessing the overlapping contours on a single beam's eye view. Results: Brachial plexus volumes for the 5 patients across observers were 26 cc (18-35 cc), 25 cc (21-30 cc), 29 cc (28-32 cc), 29 cc (23-38 cc), and 29 cc (23-34 cc). On qualitative analysis, minimal variability existed except at the inferolateral portion of the OAR, where slight discrepancies were noted among the physicians. Maximum doses to the brachial plexus ranged from 71.6 to 72.6 Gy, 75.2 to 75.8 Gy, 69.1 to 71.0 Gy, 76.4 to 76.9 Gy, and 70.6 to 71.4 Gy. Respective volumes receiving doses greater than 60 Gy (V60) were 8.6 to 10.9 cc, 6.2 to 8.1 cc, 8.2 to 11.6 cc, 8.3 to 10.5 cc, and 5.6 to 9.8 cc. Conclusion: The RTOG-endorsed brachial plexus atlas provides a consistent set of guidelines for contouring this OAR with essentially no learning curve. Adoption of these contouring guidelines in the clinical setting is encouraged.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Field Design and Patterns of Locoregional Recurrence Following Definitive Radiotherapy for Breast Cancer

Purpose: Locoregional control is associated with breast cancer-specific and overall survival in select women with breast cancer. Although several patient, tumor, and treatment characteristics have been shown to contribute to locoregional recurrence (LRR), studies evaluating factors related to radiotherapy (XRT) technique have been limited. We investigated the relationship between LRR location and XRT fields and dose delivered to the primary breast cancer in women experiencing subsequent locoregional relapse. Methods and Materials: We identified 21 women who were previously treated definitively with surgery and XRT for breast cancer. All patients developed biopsy-result proven LRR and presented to Emory University Hospital between 2004 and 2010 for treatment. Computed tomography (CT) simulation scans with XRT dose files for the initial breast cancer were fused with {sup 18}F-labeled fluorodeoxyglucose positron emission tomography (FDG PET)/CT images in DICOM (Digital Imaging and Communications in Medicine) format identifying the LRR. Each LRR was categorized as in-field, defined as {>=}95% of the LRR volume receiving {>=}95% of the prescribed whole-breast dose; marginal, defined as LRR at the field edge and/or not receiving {>=}95% of the prescribed dose to {>=}95% of the volume; or out-of-field, that is, LRR intentionally not treated with the original XRT plan. Results: Of the 24 identified LRRs (3 patients experienced two LRRs), 3 were in-field, 9 were marginal, and 12 were out-of-field. Two of the 3 in-field LRRs were marginal misses of the additional boost XRT dose. Out-of-field LRRs consisted of six supraclavicular and six internal mammary nodal recurrences. Conclusions: Most LRRs in our study occurred in areas not fully covered by the prescribed XRT dose or were purposely excluded from the original XRT fields. Our data suggest that XRT technique, field design, and dose play a critical role in preventing LRR in women with breast cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Near Real-Time Assessment of Anatomic and Dosimetric Variations for Head and Neck Radiation Therapy via Graphics Processing Unit–based Dose Deformation Framework

Purpose: The purpose of this study was to systematically monitor anatomic variations and their dosimetric consequences during intensity modulated radiation therapy (IMRT) for head and neck (H&N) cancer by using a graphics processing unit (GPU)-based deformable image registration (DIR) framework. Methods and Materials: Eleven IMRT H&N patients undergoing IMRT with daily megavoltage computed tomography (CT) and weekly kilovoltage CT (kVCT) scans were included in this analysis. Pretreatment kVCTs were automatically registered with their corresponding planning CTs through a GPU-based DIR framework. The deformation of each contoured structure in the H&N region was computed to account for nonrigid change in the patient setup. The Jacobian determinant of the planning target volumes and the surrounding critical structures were used to quantify anatomical volume changes. The actual delivered dose was calculated accounting for the organ deformation. The dose distribution uncertainties due to registration errors were estimated using a landmark-based gamma evaluation. Results: Dramatic interfractional anatomic changes were observed. During the treatment course of 6 to 7 weeks, the parotid gland volumes changed up to 34.7%, and the center-of-mass displacement of the 2 parotid glands varied in the range of 0.9 to 8.8 mm. For the primary treatment volume, the cumulative minimum and mean and equivalent uniform doses assessed by the weekly kVCTs were lower than the planned doses by up to 14.9% (P=.14), 2% (P=.39), and 7.3% (P=.05), respectively. The cumulative mean doses were significantly higher than the planned dose for the left parotid (P=.03) and right parotid glands (P=.006). The computation including DIR and dose accumulation was ultrafast (∼45 seconds) with registration accuracy at the subvoxel level. Conclusions: A systematic analysis of anatomic variations in the H&N region and their dosimetric consequences is critical in improving treatment efficacy. Nearly real-time assessment of anatomic and dosimetric variations is feasible using the GPU-based DIR framework. Clinical implementation of this technology may enable timely plan adaptation and improved outcome.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Helical Tomotherapy-Based STAT RT: Dosimetric Evaluation for Clinical Implementation of a Rapid Radiation Palliation Program

Helical tomotherapy-based STAT radiation therapy (RT) uses an efficient software algorithm for rapid intensity-modulated treatment planning, enabling conformal radiation treatment plans to be generated on megavoltage computed tomography (MVCT) scans for CT simulation, treatment planning, and treatment delivery in one session. We compared helical tomotherapy-based STAT RT dosimetry with standard linac-based 3D conformal plans and standard helical tomotherapy-based intensity-modulated radiation therapy (IMRT) dosimetry for palliative treatments of whole brain, a central obstructive lung mass, multilevel spine disease, and a hip metastasis. Specifically, we compared the conformality, homogeneity, and dose with regional organs at risk (OARs) for each plan as an initial step in the clinical implementation of a STAT RT rapid radiation palliation program. Hypothetical planning target volumes (PTVs) were contoured on an anthropomorphic phantom in the lung, spine, brain, and hip. Treatment plans were created using three planning techniques: 3D conformal on Pinnacle{sup 3}, helical tomotherapy, and helical tomotherapy-based STAT RT. Plan homogeneity, conformality, and dose to OARs were analyzed and compared. STAT RT and tomotherapy improved conformality indices for spine and lung plans (CI spine = 1.21, 1.17; CI lung = 1.20, 1.07, respectively) in comparison with standard palliative anteroposterior/posteroanterior (AP/PA) treatment plans (CI spine = 7.01, CI lung = 7.30), with better sparing of heart, esophagus, and spinal cord. For palliative whole-brain radiotherapy, STAT RT and tomotherapy reduced maximum and mean doses to the orbits and lens (maximum/mean lens dose: STAT RT = 2.94/2.65 Gy, tomotherapy = 3.13/2.80 Gy, Lateral opposed fields = 7.02/3.65 Gy), with an increased dose to the scalp (mean scalp dose: STAT RT = 16.19 Gy, tomotherapy = 15.61 Gy, lateral opposed fields = 14.01 Gy). For bony metastatic hip lesions, conformality with both tomotherapy techniques (CI = 1.01 each) is superior to AP/PA treatments (CI = 1.21), as expected. Helical tomotherapy-based STAT RT treatment planning provides clinically acceptable dosimetry, with conformality and homogeneity that is superior to standard linac-based 3D conformal planning and is only slightly inferior to standard helical tomotherapy IMRT dosimetry. STAT RT facilitates rapid treatment planning and delivery for palliative radiation of patients with metastatic disease, with relative sparing of adjacent OARs compared with standard 3D conformal plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric benefit of adaptive re-planning in pancreatic cancer stereotactic body radiotherapy

Stereotactic body radiotherapy (SBRT) shows promise in unresectable pancreatic cancer, though this treatment modality has high rates of normal tissue toxicity. This study explores the dosimetric utility of daily adaptive re-planning with pancreas SBRT. We used a previously developed supercomputing online re-planning environment (SCORE) to re-plan 10 patients with pancreas SBRT. Tumor and normal tissue contours were deformed from treatment planning computed tomographies (CTs) and transferred to daily cone-beam CT (CBCT) scans before re-optimizing each daily treatment plan. We compared the intended radiation dose, the actual radiation dose, and the optimized radiation dose for the pancreas tumor planning target volume (PTV) and the duodenum. Treatment re-optimization improved coverage of the PTV and reduced dose to the duodenum. Within the PTV, the actual hot spot (volume receiving 110% of the prescription dose) decreased from 4.5% to 0.5% after daily adaptive re-planning. Within the duodenum, the volume receiving the prescription dose decreased from 0.9% to 0.3% after re-planning. It is noteworthy that variation in the amount of air within a patient's stomach substantially changed dose to the PTV. Adaptive re-planning with pancreas SBRT has the ability to improve dose to the tumor and decrease dose to the nearby duodenum, thereby reducing the risk of toxicity.

61 RADIATION PROTECTION AND DOSIMETRY↗