Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative visualization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The generation of arbitrary order, non-classical, Gauss-type quadrature for transport applications

A method is presented, based upon the Stieltjes method (1884), for the determination of non-classical Gauss-type quadrature rules, and the associated sets of abscissae and weights. The method is then used to generate a number of quadrature sets, to arbitrary order, which are primarily aimed at deterministic transport calculations. The quadrature rules and sets detailed include arbitrary order reproductions of those presented by Abu-Shumays in [4,8] (known as the QR sets, but labelled QRA here), in addition to a number of new rules and associated sets; these are generated in a similar way, and we label them the QRS quadrature sets. The method presented here shifts the inherent difficulty (encountered by Abu-Shumays) associated with solving the non-linear moment equations, particular to the required quadrature rule, to one of the determination of non-classical weight functions and the subsequent calculation of various associated inner products. Once a quadrature rule has been written in a standard form, with an associated weight function having been identified, the calculation of the required inner products is achieved using specific variable transformations, in addition to the use of rapid, highly accurate quadrature suited to this purpose. The associated non-classical Gauss quadrature sets can then be determined, and this can be done to any order very rapidly. In this paper, instead of listing weights and abscissae for the different quadrature sets detailed (of which there are a number), the MATLAB code written to generate them is included as Appendix D. The accuracy and efficacy (in a transport setting) of the quadrature sets presented is not tested in this paper (although the accuracy of the QRA quadrature sets has been studied in [12,13]), but comparisons to tabulated results listed in [8] are made. When comparisons are made with one of the azimuthal QRA sets detailed in [8], the inherent difficulty in the method of generation, used there, becomes apparent, with the highest order tabulated sets showing unexpected anomalies. Although not in an actual transport setting, the accuracy of the sets presented here is assessed to some extent, by using them to approximate integrals (over an octant of the unit sphere) of various high order spherical harmonics. When this is done, errors in the tabulated QRA sets present themselves at the highest tabulated orders, whilst combinations of the new QRS quadrature sets offer some improvements in accuracy over the original QRA sets. Finally, in order to offer a quick, visual understanding of the various quadrature sets presented, when combined to give product sets for the purposes of integrating functions confined to the surface of a sphere, three-dimensional representations of points located on an octant of the unit sphere (as in [8,12]) are shown.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of a video image-based QA system for the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system

Purpose: To develop and evaluate a new video image-based QA system, including in-house software, that can display a tracking state visually and quantify the positional accuracy of dynamic tumor tracking irradiation in the Vero4DRT system. Methods: Sixteen trajectories in six patients with pulmonary cancer were obtained with the ExacTrac in the Vero4DRT system. Motion data in the cranio–caudal direction (Y direction) were used as the input for a programmable motion table (Quasar). A target phantom was placed on the motion table, which was placed on the 2D ionization chamber array (MatriXX). Then, the 4D modeling procedure was performed on the target phantom during a reproduction of the patient’s tumor motion. A substitute target with the patient’s tumor motion was irradiated with 6-MV x-rays under the surrogate infrared system. The 2D dose images obtained from the MatriXX (33 frames/s; 40 s) were exported to in-house video-image analyzing software. The absolute differences in the Y direction between the center of the exposed target and the center of the exposed field were calculated. Positional errors were observed. The authors’ QA results were compared to 4D modeling function errors and gimbal motion errors obtained from log analyses in the ExacTrac to verify the accuracy of their QA system. The patients’ tumor motions were evaluated in the wave forms, and the peak-to-peak distances were also measured to verify their reproducibility. Results: Thirteen of sixteen trajectories (81.3%) were successfully reproduced with Quasar. The peak-to-peak distances ranged from 2.7 to 29.0 mm. Three trajectories (18.7%) were not successfully reproduced due to the limited motions of the Quasar. Thus, 13 of 16 trajectories were summarized. The mean number of video images used for analysis was 1156. The positional errors (absolute mean difference + 2 standard deviation) ranged from 0.54 to 1.55 mm. The error values differed by less than 1 mm from 4D modeling function errors and gimbal motion errors in the ExacTrac log analyses (n = 13). Conclusions: The newly developed video image-based QA system, including in-house software, can analyze more than a thousand images (33 frames/s). Positional errors are approximately equivalent to those in ExacTrac log analyses. This system is useful for the visual illustration of the progress of the tracking state and for the quantification of positional accuracy during dynamic tumor tracking irradiation in the Vero4DRT system.

60 APPLIED LIFE SCIENCES↗

Multifunctionality of chiton biomineralized armor with an integrated visual system

Nature provides a multitude of examples of multifunctional structural materials. There are often trade-offs in these materials because few of them are equally well suited for multiple tasks. One such example is the biomineralized armor of the chiton Acanthopleura granulata, which incorporates an integrated sensory system that includes hundreds of eyes with aragonite-based lens. Here, we used optical experiments to demonstrate directly, for the first time, that these microscopic, mineralized lenses are able to form images. Furthermore, our experiments revealed that the optical performance of these polycrystalline lenses is enhanced by the reduction of spherical aberration through the shape of the lens and that birefringence scattering is minimized by the use of relatively large, co-aligned grains (~10 μm as compared to ~1 μm in the non-eye regions). Additionally, we used multi-scale mechanical testing techniques to show that A. granulata’s lenses are an integral component of its biomineralized armor, but that both the intrinsic and overall mechanical properties of the lenses are compromised as compared to the primary solid regions of the armor plates. Our results demonstrate that as the size, complexity, and functionality of the integrated sensory elements increases, the local mechanical performance of the armor decreases. But, A. granulata has evolved several strategies to compensate for its local mechanical vulnerabilities to form a multifunctional system with co-optimized overall optical and structural functions.

36 MATERIALS SCIENCE↗

Using multiple data sources to investigate foraging niche partitioning in sympatric obligate avian scavengers

As carrion feeders competing for a limited and ephemeral resource, avian scavengers are ideal model organisms to study mechanisms of niche partitioning. Previous work has focused on observations of species’ interactions at carcasses, and although fruitful, the inclusion of behavior beyond that at carcasses, such as movement patterns, could yield a more comprehensive understanding of mechanisms of foraging niche partitioning. Our goal was to assess how differences in physiological, morphological, and social characteristics between sympatric black vultures ( Coragyps atratus ) and turkey vultures ( Cathartes aura ) manifest interspecific variation in movement patterns, foraging habitats, and carcass use to reduce direct competition. Both species are obligate scavengers that co-occur across much of the New World. Turkey vultures are solitary foragers with enhanced olfactory capabilities and wings optimized for energy-efficient low-altitude soaring. Black vultures are aggressive, heavier bodied, and forage socially. We assessed interspecific variation in carcass exploitation using experimental carcass trials encompassing a range of habitats, carcass sizes, and seasons, and used GPS telemetry to compare how soaring conditions influenced daily space use and diurnal patterns of movement activity for each species. Turkey vultures occurred more often at small (i.e., rabbit) carcasses, and those obscured by forest cover than black vultures, and were the first vultures recorded at 94% of carcasses visited by both species. Both species increased movement rates and daily ranges when soaring conditions were favorable; however, turkey vultures had higher travel rates regardless of soaring conditions. Our results suggest the olfactory sense of turkey vultures allows them to locate smaller and visually obscured carcasses more efficiently than black vultures, facilitated by wing morphology that allows them to forage over large areas efficiently. Socially foraging black vultures appear specialized at locating larger carcasses in open habitats, which does not require as much foraging flight as turkey vultures. Our study illustrates how inclusion of movement ecology into niche partitioning studies provides a more complete understanding of the mechanisms of coexistence in avian scavenger guilds. This approach may provide important information to guide conservation efforts, such as supplemental feeding, of imperiled vulture species.

54 ENVIRONMENTAL SCIENCES↗

Low Phosphorylated AKT Expression in Laryngeal Cancer: Indications for a Higher Metastatic Risk

Purpose: To validate the association of phosphorylated (p)AKT with lymph node metastasis in an independent, homogeneous cohort of patients with larynx cancer. Methods and Materials: Seventy-eight patients with laryngeal cancer were included. Epidermal growth factor receptor, pAKT, vimentin, E-cadherin, hypoxia, and blood vessels were visualized in biopsy material using immunohistochemistry. Positive tumor areas and spatial relationships between markers were assessed by automated image analysis. In 6 laryngeal cancer cell lines, E-cadherin and vimentin messenger RNA was quantified by real-time polymerase chain reaction and by immunohistochemistry before and after treatment with the pAKT inhibitor MK-2206. Results: A significant correlation was found between low pAKT in the primary tumor and positive lymph node status (P=.0005). Tumors with lymph node metastases had an approximately 10-fold lower median pAKT value compared with tumors without lymph node metastases, albeit with large intertumor variations, validating our previous results. After inhibition of pAKT in laryngeal cancer cells with MK-2206, up-regulation of vimentin and a downregulation of E-cadherin occurred, consistent with epithelial–mesenchymal transition. Conclusion: Low pAKT expression in larynx tumors is associated with lymph node metastases. Further, inhibition of pAKT in laryngeal cancer induces epithelial–mesenchymal transition, predisposing for an increased metastatic risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A GPU based high-resolution multilevel biomechanical head and neck model for validating deformable image registration

Purpose: Validating the usage of deformable image registration (DIR) for daily patient positioning is critical for adaptive radiotherapy (RT) applications pertaining to head and neck (HN) radiotherapy. The authors present a methodology for generating biomechanically realistic ground-truth data for validating DIR algorithms for HN anatomy by (a) developing a high-resolution deformable biomechanical HN model from a planning CT, (b) simulating deformations for a range of interfraction posture changes and physiological regression, and (c) generating subsequent CT images representing the deformed anatomy. Methods: The biomechanical model was developed using HN kVCT datasets and the corresponding structure contours. The voxels inside a given 3D contour boundary were clustered using a graphics processing unit (GPU) based algorithm that accounted for inconsistencies and gaps in the boundary to form a volumetric structure. While the bony anatomy was modeled as rigid body, the muscle and soft tissue structures were modeled as mass–spring-damper models with elastic material properties that corresponded to the underlying contoured anatomies. Within a given muscle structure, the voxels were classified using a uniform grid and a normalized mass was assigned to each voxel based on its Hounsfield number. The soft tissue deformation for a given skeletal actuation was performed using an implicit Euler integration with each iteration split into two substeps: one for the muscle structures and the other for the remaining soft tissues. Posture changes were simulated by articulating the skeletal structure and enabling the soft structures to deform accordingly. Physiological changes representing tumor regression were simulated by reducing the target volume and enabling the surrounding soft structures to deform accordingly. Finally, the authors also discuss a new approach to generate kVCT images representing the deformed anatomy that accounts for gaps and antialiasing artifacts that may be caused by the biomechanical deformation process. Accuracy and stability of the model response were validated using ground-truth simulations representing soft tissue behavior under local and global deformations. Numerical accuracy of the HN deformations was analyzed by applying nonrigid skeletal transformations acquired from interfraction kVCT images to the model’s skeletal structures and comparing the subsequent soft tissue deformations of the model with the clinical anatomy. Results: The GPU based framework enabled the model deformation to be performed at 60 frames/s, facilitating simulations of posture changes and physiological regressions at interactive speeds. The soft tissue response was accurate with a R{sup 2} value of >0.98 when compared to ground-truth global and local force deformation analysis. The deformation of the HN anatomy by the model agreed with the clinically observed deformations with an average correlation coefficient of 0.956. For a clinically relevant range of posture and physiological changes, the model deformations stabilized with an uncertainty of less than 0.01 mm. Conclusions: Documenting dose delivery for HN radiotherapy is essential accounting for posture and physiological changes. The biomechanical model discussed in this paper was able to deform in real-time, allowing interactive simulations and visualization of such changes. The model would allow patient specific validations of the DIR method and has the potential to be a significant aid in adaptive radiotherapy techniques.

60 APPLIED LIFE SCIENCES↗

Self‐Healing of Concrete Cracks by Ceramsite‐Loaded Microorganisms

Protective carrier is essential for the self‐healing of concrete cracks by microbially induced CaCO 3 precipitation, owing to the harsh conditions in concrete. In this paper, porous ceramsite particles are used as microbial carrier. Heat treatment and NaOH soaking are first employed to improve the loading content of the ceramsite. The viability of bacterial spores is assessed by urea decomposition measurements. Then, the self‐healing efficiency of concrete cracks by spores is evaluated by a series of tests including compressive strength regain, water uptake, and visual inspection of cracks. Results indicate that heat treatment can improve the loading content of ceramsite while not leading to a reduction of concrete strength by the ceramsite addition. The optimal heating temperature is 750°C. Ceramsite particles act as a shelter and protect spores from high‐pH environment in concrete. When nutrients and spores are incorporated in ceramsite particles at the same time, nutrients are well accessible to the cells. The regain ratio of the compressive strength increases over 20%, and the water absorption ratio decreases about 30% compared with the control. The healing ratio of cracks reaches 86%, and the maximum crack width healed is near 0.3 mm.

Xu, Jing↗

Validation and Verification of Python based Neutron Spectrum Unfolding Software

To validate and verify the python-based code (PySL), designed to replicate the programs used by STAYSL for Beam Correction Factor (BCF) and Self-Shielding Factor (SHIELD), a series of tests were performed. To test BCF a python script was written to generate a random flux history file and both versions of the code processed the data. The test verified matching values up to at least one decimal place, approximately 10,000 tests where run and each one passed. Isotopes began to fail the tests once neutron saturation was reached. To verify this the total time of exposure was varied the isotopes that failed were compared to a list of their half-lives. The test process for SHIELD was very similar but, in this case, the code began by producing an input file with varying thickness and device type/environment for the SHIELD input. The failure condition for this test was if any of the data points for an isotope had a difference above 3%. Approximately 40 of these tests were run and there were only 3 isotopes that had reoccurring failures but only 2% of their points were above the 3% difference. A visual comparison was conducted by plotting the results from both programs. Although the test failed, the differences between their values were minuscule, and the self-shielding factor’s shape was preserved when plotted. Next steps for this project will be validating and verifying the python-based SigPhi code and then reproducing and testing the least squares unfolding performed by STAYSL.

73 - NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Towards Rapid Interactive Machine Learning: Evaluating Tradeoffs of Classification without Representation

Our contribution is the design and evaluation of an interac- tive machine learning interface that rapidly provides the user with model feedback after every interaction. To address visual scalability, this interface communicates with the user via a “tip of the iceberg” approach, where the user interacts with a small set of recommended instances for each class. To address computational scalability, we developed an O(n) classification algorithm that incorporates user feedback incrementally, and without consulting the underlying data’s representation matrix. Our computational evaluation showed that this algorithm has similar accuracy to several off-the-shelf classification algo- rithms with small amounts of labeled data. Empirical evalu- ation revealed that users performed better using our design compared to an equivalent active learning setup.

Arendt, Dustin L.↗

Hypersonic Wake Velocity Measurements Using Acetone Molecular Tagging Velocimetry

A non-intrusive laser diagnostic known as molecular tagging velocimetry was used to find quantitative off-body velocity measurements in the wake of a sphere in the Mach 7 Ludwieg Tube Wind Tunnel located at The University of Texas at San Antonio. Acetone gas seeded in the flow was excited using the 4th harmonic of a pulse-burst Nd:YAG laser. The experimental results were used to validate and compare to simulations using a continuous Galerkin flow solver. Both the experimental and simulated results agreed on negative velocities in the viscous shear layer. Near the centerline of the sphere, average velocities of -200 m/s were observed due to reverse flow in the recirculation region. Outside of the shear layer, velocities of 800 m/s were observed in both the experimental and simulated results. The overall average uncertainty for the strut-mounted and free-flight case was estimated to be ±27 m/s. The flow features of the wake were visualized using schlieren imaging, and the experimental results agreed well with the simulated results.

Shoemake, Lawton↗

Neutron imaging of diabatic two-phase flows relevant to air conditioning

The design of the evaporator of an air conditioning system relies heavily on heat transfer coefficients and pressure drop correlations that predominantly involve an estimate of the changing void fraction and the underlying two-phase flow regime. These correlations dictate whether the resulting heat exchanger is oversized or not and the amount of refrigerant charge necessary to operate. The latter is particularly important when dealing with flammable or high GWP refrigerants. Traditional techniques to measure the void fraction and visualize the flow are either invasive to the flow or occur downstream of the evaporator, where some of the flow distribution will have changed. Neutron imaging has the potential to visualize two-phase flow in-situ where an aluminium heat exchanger structure becomes essentially transparent to the penetrating neutrons. The subatomic particles are attenuated by the passing refrigerant flow. The resulting image may be directly related to the void fraction and the overall picture provides a clear insight into the flow regime present. This work presents neutron images of the refrigerant Isopentane as it passes through the flow channels of an aluminium evaporator at flowrates relevant to air conditioning. The flow in a 4mm square macro channel is compared to that in a 250 m by 750 m rectangular microchannel in terms of void fraction and regime. All neutron imaging experiments were conducted at the High Flux Isotope Reactor, an Oak Ridge National Laboratory facility

Geoghegan, Patrick J↗

Dynamics of unstably stratified free shear flows: an experimental investigation of coupled Kelvin–Helmholtz and Rayleigh–Taylor instability

The dynamics of the coupled Kelvin–Helmholtz (KH) and Rayleigh–Taylor (RT) instability (referred to as KHRT instability or KHRTI) is studied using statistically steady experiments performed in a multi-layer gas tunnel. Experiments are performed at four density ratios ranging in Atwood number $A_{t}$ from 0.035 to 0.159, with varying amounts of shear and $\unicode[STIX]{x0394}U/U$ ranging from 0 to 0.48, where $\unicode[STIX]{x0394}U$ is the speed difference between the two flow streams being investigated and $U$ is the mean velocity of these two streams. Three types of diagnostics – back-lit visualization, hot-wire anemometry and particle image velocimetry (PIV) – are employed to obtain the mixing widths, velocity field and density field. The flow is found to be governed by KH dynamics at early times and RT dynamics at late times. This transition from KH-instability-like to RT-instability-like behaviour is quantified using the Richardson number. Transitional Richardson number magnitudes obtained for the present KHRT flows are found to be in the range 0.17–0.56 similar to the critical Richardson numbers for stably stratified free shear flows. Comparing the evolution of density and velocity mixing widths, the density mixing layer is found to be approximately two times as thick as the velocity mixing layer. Scaling of velocity fluctuations is attempted using combinations of KH and RT scales. It is found that the proposed KHRT velocity scale, obtained using the combined mixing-layer growth equation, is appropriate for intermediate stages of the flow when both KH and RT dynamics are comparable. Probability density functions (p.d.f.s) for different fluctuating quantities are presented. Multiple peaks in p.d.f.s are qualitatively explained from the development of coherent KH roll-ups and their subsequent transition into turbulent pockets. The evolution of energy spectra indicates that density fluctuations start to show an inertial subrange from earlier times compared to velocity fluctuations. The spectra exhibit a slightly steeper slope than the Kolmogorov–Obukhov five-thirds law.

Mechanics↗

SDSS-IV DR17: final release of MaNGA PyMorph photometric and deep-learning morphological catalogues

ABSTRACT We present the MaNGA PyMorph photometric Value Added Catalogue (MPP-VAC-DR17) and the MaNGA Deep Learning Morphological VAC (MDLM-VAC-DR17) for the final data release of the MaNGA survey, which is part of the SDSS Data Release 17 (DR17). The MPP-VAC-DR17 provides photometric parameters from Sérsic and Sérsic+Exponential fits to the two-dimensional surface brightness profiles of the MaNGA DR17 galaxy sample in the g, r, and i bands (e.g. total fluxes, half-light radii, bulge-disc fractions, ellipticities, position angles, etc.). The MDLM-VAC-DR17 provides deep-learning-based morphological classifications for the same galaxies. The MDLM-VAC-DR17 includes a number of morphological properties, for example, a T-Type, a finer separation between elliptical and S0, as well as the identification of edge-on and barred galaxies. While the MPP-VAC-DR17 simply extends the MaNGA PyMorph photometric VAC published in the SDSS Data Release 15 (MPP-VAC-DR15) to now include galaxies that were added to make the final DR17, the MDLM-VAC-DR17 implements some changes and improvements compared to the previous release (MDLM-VAC-DR15): Namely, the low end of the T-Types is better recovered in this new version. The catalogue also includes a separation between early or late type, which classifies the two populations in a complementary way to the T-Type, especially at the intermediate types (−1 < T-Type < 2), where the T-Type values show a large scatter. In addition, k-fold-based uncertainties on the classifications are also provided. To ensure robustness and reliability, we have also visually inspected all the images. We describe the content of the catalogues and show some interesting ways in which they can be combined.

79 ASTRONOMY AND ASTROPHYSICS↗

Can we observe the ion-neutral drift velocity in prestellar cores?

Given the low-ionization fraction of molecular clouds, ambipolar diffusion is thought to be an integral process in star formation. However, chemical and radiative-transfer effects, observational challenges, and the fact that the ion-neutral drift velocity is inherently very small render a definite detection of ambipolar diffusion extremely non-trivial. Here, we study the ion-neutral drift velocity in a suite of chemodynamical, non-ideal magnetohydrodynamic (MHD), two-dimensional axisymmetric simulations of prestellar cores where we alter the temperature, cosmic-ray ionization rate, visual extinction, mass-to-flux ratio, and chemical evolution. Subsequently, we perform a number of non-local thermodynamic equilibrium (non-LTE) radiative-transfer calculations considering various idealized and non-idealized scenarios in order to assess which factor (chemistry, radiative transfer, and/or observational difficulties) is the most challenging to overcome in our efforts to detect the ion-neutral drift velocity. We find that temperature has a significant effect in the amplitude of the drift velocity with the coldest modelled cores (T = 6 K) exhibiting drift velocities comparable to the sound speed. Against expectations, we find that in idealized scenarios (where two species are perfectly chemically co-evolving) the drift velocity ‘survives’ radiative-transfer effects and can in principle be observed. However, we find that observational challenges and chemical effects can significantly hinder our view of the ion-neutral drift velocity. Finally, we propose that HCN and HCNH + ⁠, being chemically co-evolving, could be used in future observational studies aiming to measure the ion-neutral drift velocity.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-P-33: Critical Role of T2-Weighted Imaging Combined with Diffusion-Weighted Imaging of MRI in Diagnosis of Loco-Regional Recurrent Esophageal Cancer After Radical Surgery

Purpose: We perform this study to investigate the diagnostic efficacy of T2-weighted MRI (T2WI) and diffusion-weighted MRI (DWI) in confirming local relapses of esophageal cancer in patients highly suspected of recurrence after eradicating surgery. Methods: Forty-two postoperative esophageal cancer patients with clinical suspicions of cancer recurrence underwent 3.0T MRI applying axial, coronal, sagittal T2WI and axial DWI sequences. Two experienced radiologists (R1 and R2) both used two methods (T2WI, T2WI+DWI) to observe the images, and graded the patients ranging from 1 to 5 to represent severity of the disease based on visual signal intensity (patients equal to or more than grade 3 was confirmed as recurrent disease) Results: 27/42patients were verified of recurrent disease by pathologic findings and/or imaging findings during follow-up. The sensitivity, specificity and accuracy of R1 applying T2WI+DWI are 96%, 87% and 93% versus 81%, 80% and 77% on T2WI, these figures by R2 were 96%, 93% and 95% versus 89%, 93% and 90%. The receiver operating curve (ROC) analyses suggest that both of the two readers can obtain better accuracy when adding DWI to T2WI compared with T2WI alone. Kappa test between R1 and R2 indicates excellent inter-observer agreement on T2WI+DWI. Conclusion: Standard T2WI in combination DWI can achieve better accuracy than T2WI alone in diagnosing local recurrence of esophageal cancer, and improve consistency between different readers.

60 APPLIED LIFE SCIENCES↗

The Sentinel Lymph Node Biopsy Using Indocyanine Green Fluorescence Plus Radioisotope Method Compared With the Radioisotope-Only Method for Breast Cancer Patients After Neoadjuvant Chemotherapy: A Prospective, Randomized, Open-Label, Single-Center Phase 2 Trial

Background: This study aimed to compare the sentinel lymph node (SLN) identification rates for breast cancer patients after neoadjuvant chemotherapy (NAC) between the dual method (DM) of indocyanine green fluorescence (ICG-F) plus a radioisotope (RI) and RI alone. Methods: This randomized study enrolled 130 patients who received NAC for breast cancer and 122 patients who received SLN biopsy (SLNB) using either DM (n = 58) or RI only (n = 64). The study compared the identification rate, number of SLNs, and detection time of SLNB. Results: Among the 122 patients, 113 (92.6%) were clinically node-positive before NAC. The SLN identification rate was 98.3% in the DM group and 93.8% in the RI group (p = 0.14). The DM group and the RI group were similar in the average number of SLNs (2.2 ± 1.13 vs. 1.9 ± 1.33; p = 0.26) and the time to detection of the first SLN (8.7 ± 4.98 vs. 8.3 ± 4.31 min; p = 0.30). In the DM group, transcutaneous lymphatic drainage was visualized by fluorescence imaging for 65.5% (38 of 58) of the patients. The SLN identification rate was 94.7% using ICG-F and 93% using RI (p = 0.79). During and after the operation, no complications, including allergic reactions or skin necrosis, occurred. Conclusions: This study is the first randomized trial to use ICG-F for SLNB in breast cancer patients after NAC. The DM including ICG-F could be a feasible and safe method for SLNB in initially node-positive breast cancer patients with NAC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Disentangling Ferroelectric Wall Dynamics and Identification of Pinning Mechanisms via Deep Learning

Field-induced domain-wall dynamics in ferroelectric materials underpins multiple applications ranging from actuators to information technology devices and necessitates a quantitative description of the associated mechanisms including giant electromechanical couplings, controlled nonlinearities, or low coercive voltages. While the advances in dynamic piezoresponse force microscopy measurements over the last two decades have rendered visualization of polarization dynamics relatively straightforward, the associated insights into the local mechanisms have been elusive. This work explores the domain dynamics in model polycrystalline materials using a workflow combining deep-learning-based segmentation of the domain structures with nonlinear dimensionality reduction using multilayer rotationally invariant autoencoders (rVAE). The former allows unambiguous identification and classification of the ferroelectric and ferroelastic domain walls. Here, the rVAE discovers the latent representations of the domain wall geometries and their dynamics, consequently providing insight into the intrinsic mechanisms of polarization switching, that can further be compared to simple physical models. The rVAE disentangles the factors affecting the pinning efficiency of ferroelectric walls, offering insights into the correlation of ferroelastic wall distribution and ferroelectric wall pinning.

36 MATERIALS SCIENCE↗

Intra- and inter-observer variability in breast tumour bed contouring and the controversial role of surgical clips

The purpose of this study was to evaluate whether the visualization of surgical clips (SCs) on the same set of planning computed tomography (CT) of breast cancer (BC) patients influences agreement on tumour bed (TB) delineation. Planning CT (CT{sub orig}) of 47 BC patients with SCs to visualize the TB was processed in order to blur SCs and create a virtual CT (CT{sub mod}). Four radiation oncologists (ROs, 2 juniors and 2 seniors) contoured TB on both the CT sets. Centre of mass distance (CMD), percentage overlap as Dice similarity coefficient (DSC), surface distance as average Hausdorff distance (AHD) and TB volume size were analysed. The intra-observer variability when contouring TB with and without SCs was statistically significant (p-values = 0.016, 0.0002 and ≪ 0.001 for CMD, AHD and DSC, respectively). Junior ROs showed worse reproducibility compared to seniors. The median DSC was < 0.7. The inter-observer variability with and without SCs was statistically significant (p < 0.001) for all metrics, with an increase of 48.7% in DSC and decrease of 50.7% and 57.1% in CMD and AHD, respectively, as relative median values, when SCs were visible. Regarding TB volumes, when SCs were visible, the intra-observer analysis revealed that 3/4 ROs delineated larger volumes, especially juniors. The inter-observer analysis showed that, in presence of visible SCs, the difference in TB volume among all the ROs fell from statistically significant to borderline significance (p = 0.052). TB contouring is confirmed to be an observer-dependent task. SCs decreased the intra and inter-observer variability but the overall agreement between ROs remained low.

62 RADIOLOGY AND NUCLEAR MEDICINE↗