Experimental and numerical evaluations of the energy savings potential of thermally anisotropic composites
Previous numerical studies conducted in FY 17 showed that the application of thermally anisotropic composites (TACs) coupled with a heat sink/source can re-direct and reduce unwanted heat flows through exterior building walls, with associated reductions in envelope-generated heating and cooling loads in buildings. The numerical analyses included two-dimensional finite element models (FEM) of wall assemblies and whole-building modeling to estimate the annual reductions in wall-generated heating and cooling loads, and associated energy consumption. The FY17 study used combined FEM and EnergyPlus (E+) simulations of a typical two-story, single-family DOE prototype residential building model.1 We studied performance of several configurations of walls containing exterior continuous insulation and thermally anisotropic composites on the wall exterior. The study showed that annual energy cost savings of up to $270 are possible under Phoenix and Baltimore weather conditions, by retrofitting a baseline wall with an anisotropic composite. In the cases considered, the TAC consisted of three layers of aluminum foil-faced foam boards. In general, it was found that the anisotropic composites were effective in reducing cooling loads; more investigation on heating loads is needed. During FY 18, ORNL performed a series of laboratory tests of anisotropic composites and appropriate heat sink/source, validated the FEMs used for the FY17 numerical study using experimental data, and revisited the whole-building modeling. Wall prototypes were created and tested in ORNL’s large scale climate simulator (LSCS) under variable conditions approximating summer and winter time periods.