Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct current system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

KDHE Project Code: C6-074-00002: Progress and Monitoring Report for the LDB/SVE/AS System at the Former CCC/USDA Grain Storage Facility, Agra, Kansas, in July-December 2015

The Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) operated a grain storage facility at Agra, Kansas, from the 1950s to the early 1970s. No structures remain on the property, and the land is used for agricultural purposes, specifically wheat production. The property is currently owned by the Kyle Railroad Co. and is leased to Mr. Herb VanEaton. The Pro-Ag Marketing grain storage facility is directly south of the former CCC/USDA facility. Quarterly progress reports for October-December 2008, January-March 2009, and April- June 2009 (Argonne 2009a,b,c) provided detailed information regarding construction and startup of the cleanup. Previous periodic monitoring reports (Argonne 2010a,b,c,d, 2011a,b,c, 2012, 2013a,b,c, 2014a,b) have tracked the subsequent progress of the cleanup effort. Data for evaluation of system performance are collected primarily by sampling SVE effluents, soil gas monitoring points, and groundwater wells for analysis for volatile organic compounds (VOCs). Table 1.1 provides a detailed chronological summary of activities during implementation of the cleanup.

58 GEOSCIENCES↗

Advanced Monitoring Systems for Deep Vadose Zone Applications Interim Status Report

The vadose zone within the Hanford Central Plateau contains large quantities of mobile contaminants that have not yet reached the groundwater. Deep vadose zone (DVZ) contamination is located below the depth of direct contaminant exposure potential, but may be a current and/or potential future source of groundwater contamination. Monitoring to observe subsurface processes and driving forces related to contaminant transport or to directly observe contaminant movement in the DVZ provide remedy performance information prior to contaminants reaching the groundwater and thereby are important elements of a remedy implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

First study of neutrino angle reconstruction using quasielasticlike interactions in MicroBooNE

We investigate the expected precision of the reconstructed neutrino direction using a 𝜈 𝜇 -argon quasielasticlike event topology with one muon and one proton in the final state and the reconstruction capabilities of the MicroBooNE liquid argon time projection chamber. This direction is of importance in the context of DUNE sub-GeV atmospheric oscillation studies. MicroBooNE allows for a data-driven quantification of this resolution by investigating the deviation of the reconstructed muon-proton system orientation with respect to the well-known direction of neutrinos originating from the Booster Neutrino Beam with an exposure of 1.3 ×10 21 protons on target. Using simulation studies, we derive the expected sub-GeV DUNE atmospheric-neutrino reconstructed simulated spectrum by developing a reweighting scheme as a function of the true neutrino energy. We further report flux-integrated single- and double-differential cross section measurements of charged-current 𝜈 𝜇 quasielasticlike scattering on argon as a function of the muon-proton system angle using the full MicroBooNE data sets. We also demonstrate the sensitivity of these results to nuclear effects and final state hadronic reinteraction modeling.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structural evidence suggests that antiactivator ExsD from Pseudomonas aeruginosa is a DNA binding protein

The opportunistic pathogen P. aeruginosa utilizes a type III secretion system (T3SS) to support acute infections in predisposed individuals. In this bacterium, expression of all T3SS-related genes is dependent on the AraC-type transcriptional activator ExsA. Before host contact, the T3SS is inactive and ExsA is repressed by the antiactivator protein ExsD. The repression, thought to occur through direct interactions between the two proteins, is relieved upon opening of the type III secretion (T3S) channel when secretion chaperone ExsC sequesters ExsD. We have solved the crystal structure of ?20ExsD, a protease-resistant fragment of ExsD that lacks only the 20 amino terminal residues of the wild-type protein at 2.6 {angstrom}. Surprisingly the structure revealed similarities between ExsD and the DNA binding domain of transcriptional repressor KorB. A model of an ExsD-DNA complex constructed on the basis of this homology produced a realistic complex that is supported by the prevalence of conserved residues in the putative DNA binding site and the results of differential scanning fluorimetry studies. Our findings challenge the currently held model that ExsD solely acts through interactions with ExsA and raise new questions with respect to the underlying mechanism of ExsA regulation.

59 BASIC BIOLOGICAL SCIENCES↗

Modeling stream temperature in the Anthropocene: An earth system modeling approach

A new large-scale stream temperature model has been developed within the Community Earth System Model (CESM) framework. The model is coupled with the Model for Scale Adaptive River Transport (MOSART) that represents river routing and a water management model (WM) that represents the effects of reservoir operations and water withdrawals on flow regulation. The coupled models allow the impacts of reservoir operations and withdrawals on stream temperature to be explicitly represented in a physically based and consistent way. The models have been applied to the Contiguous United States driven by observed meteorological forcing. It is shown that the model is capable of reproducing stream temperature spatiotemporal variation satisfactorily by comparison against the observed streamflow from over 320 USGS stations. Including water management in the models improves the agreement between the simulated and observed streamflow at a large number of stream gauge stations. Both climate and water management are found to have important influence on the spatiotemporal patterns of stream temperature. More interestingly, it is quantitatively estimated that reservoir operation could cool down stream temperature in the summer low-flow season (August – October) by as much as 1~2oC over many places, as water management generally mitigates low flow, which has important implications to aquatic ecosystems. In conclusion, sensitivity of the simulated stream temperature to input data and reservoir operation rules used in the WM model motivates future directions to address some limitations in the current modeling framework.

54 ENVIRONMENTAL SCIENCES↗

Assessing the Performance of Surface and Subsurface Engineered Barriers (Final Technical Report)

Modern engineered containment systems used at landfills and other waste disposal sites are designed to isolate municipal, industrial, and hazardous wastes and to prevent contaminated leachates and gases from escaping into the environment. The two primary questions posed in this study were: How well are these engineered barrier systems working? How long are they likely to work effectively? Up to 20 years of field observations suggest that engineered waste containment barrier systems that are designed, constructed, operated, and maintained in accordance with current statutory regulations and requirements have so far provided environmental protection at or above specified levels. However, these barriers have not been in existence long enough to assess long-term (post closure) performance for periods that may need to extend for hundreds of years. Much of the available data are from monitoring the environment downstream of the barrier, and there is little direct monitoring of the barriers themselves. New monitoring techniques, expanded collection and reporting of data and periodic assessments of barrier system effectiveness are needed to further increase confidence in barrier system performance.

42 ENGINEERING↗

A review of artificial intelligence applications in manufacturing operations

Abstract Artificial intelligence (AI) and machine learning (ML) can improve manufacturing efficiency, productivity, and sustainability. However, using AI in manufacturing also presents several challenges, including issues with data acquisition and management, human resources, infrastructure, as well as security risks, trust, and implementation challenges. For example, getting the data needed to train AI models can be difficult for rare events or costly for large datasets that need labeling. AI models can also pose security risks when integrated into industrial control systems. In addition, some industry players may be hesitant to use AI due to a lack of trust or understanding of how it works. Despite these challenges, AI has the potential to be extremely helpful in manufacturing, particularly in applications such as predictive maintenance, quality assurance, and process optimization. It is important to consider the specific needs and capabilities of each manufacturing scenario when deciding whether and how to use AI in manufacturing. This review identifies current developments, challenges, and future directions in AI/ML relevant to manufacturing, with the goal of improving understanding of AI/ML technologies available for solving manufacturing problems, providing decision‐support for prioritizing and selecting appropriate AI/ML technologies, and identifying areas where further research can yield transformational returns for the industry. Early experience suggests that AI/ML can have significant cost and efficiency benefits in manufacturing, especially when combined with the ability to capture enormous amounts of data from manufacturing systems.

Plathottam, Siby Jose↗

Twistact techno-economic analysis for wind turbine applications.

This report is the final deliverable for a techno-economic analysis of the Sandia National Laboratories-developed Twistact rotary electrical conductor. The U.S. Department of Energy Wind Energy Technologies Office supported a team of researchers at Sandia National Laboratories and the National Renewable Energy Laboratory to evaluate the potential of the Twistact technology to serve as a viable replacement to rare-earth materials used in permanent-magnet direct-drive wind turbine generators. This report compares three detailed generator models, two as baseline technologies and a third incorporating the Twistact technology. These models are then used to calculate the levelized cost of energy (LCOE) for three comparable offshore wind plants using the three generator topologies. The National Renewable Energy Laboratory s techno-economic analysis indicates that Twistact technology can be used to design low-maintenance, brush-free, and wire-wound (instead of rare-earth-element (REE) permanent-magnet), direct-drive wind turbine generators without a significant change in LCOE and generation efficiency. Twistact technology acts as a hedge against sources of uncertain costs for direct-drive generators. On the one hand, for permanent-magnet direct-drive (PMDD) generators, the long-term price of REEs may increase due to increases in future demand, from electric vehicles and other technologies, whereas the supply remains limited and geographically concentrated. The potential higher prices in the future adversely affect the cost competitiveness of PMDD generators and may thwart industry investment in the development of the technology for wind turbine applications. Twistact technology can eliminate industry risk around the uncertainty of REE price and availability. Traditional wire-wound direct-drive generators experience reliability issues and higher maintenance costs because of the wear on the contact brushes necessary for field excitation. The brushes experience significant wear and require regular replacement over the lifetime of operation (on the order of a year or potentially less time). For offshore wind applications, the focus of this study, maintenance costs are higher than typical land-based systems due to the added time it often requires to access the site for repairs. Thus, eliminating the need for regular brush replacements reduces the uncertain costs and energy production losses associated with maintenance and replacement of contact brushes. Further, Twistact has a relatively negligible impact on LCOE but hedges risks associated with the current dominant designs for direct-drive generators for PMDD REE price volatility and wire-wound generator contact brush reliability. A final section looks at the overall supply chain of REEs considering the supply-side and demand-side drivers that encourage the risk of depending on these materials to support future deployment of not only wind energy but other industries as well.

17 WIND ENERGY↗

A unified realization of electrical quantities from the quantum International System of Units

In the revised International System of Units (SI), the ohm and the volt are realized from the von Klitzing constant and the Josephson constant, and a practical realization of the ampere is possible by applying Ohm’s law directly to the quantum Hall and Josephson effects. As a result, it is possible to create an instrument capable of realizing all three primary electrical units, but the development of such a system remains challenging. Here, in this study, we report a unified realization of the volt, ohm and ampere by integrating a quantum anomalous Hall resistor (QAHR) and a programmable Josephson voltage standard (PJVS) in a single cryostat. Our system has a quantum voltage output that ranges from 0.24 mV to 6.5 mV with combined relative uncertainties down to 3 μV V −1 . The QAHR provides a realization of the ohm at zero magnetic field with uncertainties near 1 μΩ Ω −1 . We use the QAHR to convert a longitudinal current to a quantized Hall voltage and then directly compare that against the PJVS to realize the ampere. We determine currents in the range of 9.33–252 nA, and our lowest uncertainty is 4.3 μA A −1 at 83.9 nA. For other current values, a systematic error that ranges from −10 μA A −1 to −30 μA A −1 is present due to the imperfect isolation of the PJVS microwave bias.

Quantum metrology↗

Ideal evolution of magnetohydrodynamic turbulence when imposing Taylor-Green symmetries

We investigate the ideal and incompressible magnetohydrodynamic (MHD) equations in three space dimensions for the development of potentially singular structures. The methodology consists in implementing the fourfold symmetries of the Taylor-Green vortex generalized to MHD, leading to substantial computer time and memory savings at a given resolution; we also use a regridding method that allows for lower-resolution runs at early times, with no loss of spectral accuracy. One magnetic configuration is examined at an equivalent resolution of $6144^3$ points and three different configurations on grids of $4096^3$ points. At the highest resolution, two different current and vorticity sheet systems are found to collide, producing two successive accelerations in the development of small scales. At the latest time, a convergence of magnetic field lines to the location of maximum current is probably leading locally to a strong bending and directional variability of such lines. A novel analytical method, based on sharp analysis inequalities, is used to assess the validity of the finite-time singularity scenario. This method allows one to rule out spurious singularities by evaluating the rate at which the logarithmic decrement of the analyticity-strip method goes to zero. The result is that the finite-time singularity scenario cannot be ruled out, and the singularity time could be somewhere between $t = 2.33$ and $t = 2.70$. More robust conclusions will require higher resolution runs and grid-point interpolation measurements of maximum current and vorticity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Simulating large one-dimensional neutral-atom quantum systems

While abstract models of quantum computation assume a closed system of two-level states, practical quantum devices inevitably couple to the environment in some way, creating sources of noise. Understanding the tolerance to noise of specific quantum algorithms run on specific devices is important for determining the feasibility of quantum computing in the current noisy intermediate-scale quantum era. Of particular interest is understanding the noise sensitivity of these devices as more qubits are added to the system. Classical simulations are a useful tool to understand the effects of this noise, but direct classical simulations of open quantum systems are burdened by an exponentially growing cost in the number of qubits and a large local Hilbert space dimension. For onedimensional, shallow circuits, using tensor networks can replace this exponential cost with a linear one and simulate far wider systems than what would normally be available. In this paper, we describe a tensor network simulation of a neutral atom quantum system under the presence of noise, while introducing a purity-preserving truncation technique that compromises between the simplicity of the matrix product state and the positivity of the matrix product density operator. We apply this simulation to a near-optimized iteration of the quantum approximate optimization algorithm on a transverse field Ising model in order to investigate the influence of large system sizes on the performance of the algorithm. We find that while circuits with a large number of qubits fail more often under noise that depletes the qubit population, their outputs on a successful measurement are just as robust under Rydberg atom dissipation or qubit dephasing as smaller systems. However, such circuits might not perform as well under coherent multiqubit errors such as Rydberg atom crosstalk. We also find that the optimized parameters are especially robust to noise, suggesting that a noisier quantum system can be used to find the optimal parameters before switching to a cleaner system for measurements of observables.

Allen, James↗

Comparing Cetane Number Measurement Methods

Cetane number is one of the most important fuel performance metrics for mixing controlled compression-ignition “diesel” engines, quantifying a fuel’s propensity for autoignition when injected into end-of-compression-type temperature and pressure conditions. The historical default and referee method on a Cooperative Fuel Research (CFR) engine configured with indirect fuel injection and variable compression ratio is cetane number (CN) rating. A subject fuel is evaluated against primary reference fuel blends, with heptamethylnonane defining a low-reactivity endpoint of CN = 15 and hexadecane defining a high-reactivity endpoint of CN = 100. While the CN scale covers the range from zero (0) to 100, typical testing is in the range of 30 to 65 CN. Alternatively, several constant-volume combustion chamber (CVCC)-based cetane rating devices have been developed to rate fuels with an equivalent derived cetane number (DCN) or indicated cetane number (ICN). These devices measure ignition delay for fuel injected into a fixed volume of high-temperature and high-pressure air to simulate end-of-compression-type conditions. In this study, a range of novel fuel compounds are evaluated across three CVCC methods: the Ignition Quality Tester (IQT), Fuel Ignition Tester (FIT), and Advanced Fuel Ignition Delay Analyzer (AFIDA). Resulting DCNs and ICNs are compared for fuels within the normal diesel fuel range of reactivity, as well as very high (~100) and very low DCNs/ICNs (~5). Distinct differences between results from various devices are discussed. This is important to consider because some new, high-efficiency advanced compression-ignition (CI) engine combustion strategies operate with more kinetically controlled distributed combustion as opposed to mixing controlled diffusion flames. These advanced combustion strategies may benefit from new fuel chemistries, but current rating methods of CN, DCN, and ICN may not fully describe their performance. In addition, recent evidence suggests ignition delay in modern on-road diesel engines with high-pressure common rail fuel injection systems may no longer directly correlate to traditional CN fuel ratings. Simulated end-of-compression conditions are compared for CN, DCN, and ICN and discussed in the context of modern diesel engines to provide additional insight. Results highlight the potential need for revised and/or multiple fuel test conditions to measure fuel performance for advanced CI strategies.

47 OTHER INSTRUMENTATION↗

Smart Ventilation for Advanced California Homes

This project investigated smart ventilation approaches to minimize energy use for providing indoor air quality (IAQ) in high performance new California homes. Evaluation criteria included annual ventilation-related energy, peak energy and time-of-use savings, and the indoor air quality relative to a minimally code-compliant ventilation system. The simulations used CONTAM’s air flow and contaminant transport model, combined with the EnergyPlus building loads model. House types representing the default California Energy Code compliance homes were investigated for four California climate zones, covering a wide range of climate types. Both single and multi-zone smart ventilation controls were investigated. Contaminant sources included contaminants emitted continuously and varying with time, temperature and relative humidity, episodic emissions from occupant activities and outdoor particles. Single-zone ventilation controls that varied ventilation depending on outdoor temperatures were able to consistently save half of ventilation-related energy without compromising long-term IAQ. Ventilation strategies that tracked occupancy were less successful, because this work included generic contaminants with constant background emission rates. Energy performance for occupancy controls improved with a one-hour pre-occupancy flush out strategy. The addition of zoning ventilation controls did not offer significant IAQ to energy improvements compared to non-zonal versions of the same ventilation system type. The best controls had HVAC energy savings of 10-20%, with individual cases reaching up to 40% savings. However, these savings cannot be achieved without worsening personal exposures for at least one contaminant. A metric is needed to assess the competing changes in exposure to different contaminants in order to determine the net-health impacts of a control strategy. Controls that directly sensed contaminants and controlled them to acceptable levels showed that the California OEHHA limit for formaldehyde completely dominates system performance, with homes not able to meet the limit even with continuous operation of a fan sized to twice the current code minimum.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Embedded acoustic sensing and monitoring techniques for small modular reactors

The goal of this project was to study the applicability of specific innovative instrumentation techniques for assessing parameters needed for safe small modular reactor operation and safeguarding of nuclear material. Small modular reactor core designs are currently being developed to provide energy more effectively and efficiently than in the past because they can be built as modules at fabrication sites and then transported to a power-producing facility. However, these modules and/or the final core will often be sealed and not accessible again until disposal. Instead of instruments that access the core directly, during and after operation, to monitor flux/dose and structural integrity, as current power plants use, new sensors need to be designed that can be built into the reactor initially to determine operating history, structural integrity through operation of the system, and nuclear material accountancy after shutdown and before disposition of the core. Embedded sensors already exist that can provide neutron flux, gamma dose, and temperatures, but techniques to expand upon these for assessing structural health and material inventory in the system over time need to be developed. Structural health assessments include the detection and imaging of cracks in the components that could eventually cause radioactive fission products to be released.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Methods to improve burst uniformity and efficiency in exploding foil initiators

Exploding foil initiator apparatus, system, and method that improve the current density in the bridge region by modifying the shape and dimensions of the bridge and related components. The exploding foil initiator reduces burn-back by making areas of the bridge thicker except directly under the flyer. The exploding foil initiator boards are built so the flyer is not connected to the rest of the top cover-lay. This avoids losing energy due to the flyer having to tear away from the solid cover-lay.

Rhodes, Mark↗

A Commercial Building Plug Load Management System that Uses Internet of Things Technology to Automatically Identify Plugged-In Devices and Their Locations

Plug and process loads (PPLs) account for a large portion of U.S. commercial building energy use. There is a huge potential to reduce whole building consumption by targeting PPLs for energy savings measures or implementing some form of plug load management (PLM). Despite this potential, there has yet to be a widely adopted commercial PLM technology. This paper describes the Automatic Type and Location Identification System (ATLIS), a PLM system framework with automatic and dynamic load detection (ADLD). ADLD gives PLM systems the ability to automatically identify devices as they are plugged into the outlets of a building. The ATLIS framework takes advantage of smart, connected devices to identify device locations in a building, meter and control their power, and communicate this information to a central database. ATLIS includes five primary capabilities: location identification, communication, control, energy metering, and data storage. A laboratory proof of concept (PoC) demonstrated all but the energy metering capability, and these capabilities were validated using a series of system tests. The PoC was able to identify when a device was plugged into an outlet and the location of the device in the building. When a device was moved, the PoC's dashboard and database were automatically updated with the new location. The PoC implemented controls to devices from the system dashboard so that devices maintained correct schedules regardless of where they were plugged in within the building. ATLIS's primary technology application is improved PLM, but other applications include asset management, energy audits, and interoperability for grid-interactive efficient buildings. An ATLIS-based system could also be used to direct power to critical devices, such as ventilators, during a brownout or blackout. Such a framework is an opportunity to make PLM more widespread and reduce the amount of energy consumed by PPLs in current and future commercial buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Emerging Threats in Transportation Security Related to Intelligent Transportation Systems (ITS)

Transport of high-consequence shipments requires a resilient and robust systems of systems to guarantee cargo arrival. Furthermore, rising adoption of technologies such as connected and automated vehicles (CAVs), intelligent infrastructure, and vehicle-to-everything (V2X) communication presents unique challenges for securing transportation systems. Within these Intelligent Transportation Systems (ITS), several additional vulnerabilities exist that create pathways for adversarial attacks and cargo interception. For example, connectivity provides cyber pathways directly into vehicle systems and infrastructure for malicious actors. Furthermore, advanced vehicle automation exposes additional vehicle control necessary for shipment interception otherwise unavailable to adversaries. Within this paper, we will discuss the specific threats introduced by ITS-enabled technologies currently deployed and in development. These include those mentioned related to connectivity and automation, but will be expanded into grid, infrastructure, and vehicle specific threats. In addition, we will discuss how to potentially mitigate these emerging challenges as well as how to safeguard transportation systems from next generation attacks.

Cook, Adian [ORNL] (ORCID:0000000160825395)↗

ENERGY DISSIPATION IN MAGNETIC NULL POINTS AT KINETIC SCALES

We use kinetic particle-in-cell and MHD simulations supported by an observational data set to investigate magnetic reconnection in clusters of null points in space plasma. The magnetic configuration under investigation is driven by fast adiabatic flux rope compression that dissipates almost half of the initial magnetic field energy. In this phase powerful currents are excited producing secondary instabilities, and the system is brought into a state of “intermittent turbulence” within a few ion gyro-periods. Reconnection events are distributed all over the simulation domain and energy dissipation is rather volume-filling. Numerous spiral null points interconnected via their spines form null lines embedded into magnetic flux ropes; null point pairs demonstrate the signatures of torsional spine reconnection. However, energy dissipation mainly happens in the shear layers formed by adjacent flux ropes with oppositely directed currents. In these regions radial null pairs are spontaneously emerging and vanishing, associated with electron streams and small-scale current sheets. The number of spiral nulls in the simulation outweighs the number of radial nulls by a factor of 5–10, in accordance with Cluster observations in the Earth's magnetosheath. Twisted magnetic fields with embedded spiral null points might indicate the regions of major energy dissipation for future space missions such as the Magnetospheric Multiscale Mission.

79 ASTRONOMY AND ASTROPHYSICS↗