Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distributed Solar”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The influence of NO and ClO variations at twilight on the interpretation of solar occultation measurements

The influence of short lived photochemically produced species on solar occultation measurements of ClO and NO was examined. Time varying altitude profiles of ClO and NO were calculated with a time dependent photochemical model to simulate the distribution of these species during a solar occultation measurement. These distributions were subsequently used to calculate simulated radiances for various tangent paths from which mixing ratios were inferred with a conventional technique that assumes spherical symmetry. These results show that neglecting the variation of ClO in the retrieval process produces less than a 10 percent error between the true and inverted profile for both sunrise and sunset above 18 km. For NO, errors are less than 10 percent for tangent altitudes above about 35 km for sunrise and sunset; at lower altitudes, the error increases, approaching 100 percent at altitudes near 25 km. the results also show that average inhomogeneity factors, which measure the concentration variation along the tangent path and which can be calculated from a photochemical model, can indicate which species require more careful data analysis.

Boughner, R.↗

Model Formulations: Integrating Distributed Energy Resources (DER) using Advanced Unit Commitment Models and DER Aggregation Methodologies

A distribution energy resource aggregator (DERA) constitutes a group of distribution energy resources with small generation capacities which meet the threshold to participate in the electricity wholesale market. This document provides the proposed DERA model formulation that will be implemented in the SCUC simulation’s architecture for the SCUC-DER project. Different economical assessment methodologies have been developed to incorporated bids for individual distributed resources, which include solar cost dispatch and cost model, BESS opportunity cost offer algorithm, and price sensitive demand response model. Detailed methods are proposed to aggregate individual cost offers to a DERA cost curve to bid in SCUC market while three methods are proposed to simulate DER actual dispatch. Based on the DERA models in this document, the SCUC-DER project will be able to assess the impacts of DERA on the distribution system’s operation and reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Investigation of Bipropellant Plume-Induced Contamination Effects on Coverglass Materials

Contamination and degradation of external spacecraft materials by unburned and partially combusted species from bipropellant thruster plumes has long been observed as a key component of the induced space environment. Space shuttle flight experiments and returned flight hardware from the International Space Station (ISS) have both experienced microscopic impact features induced by high-velocity thruster plume droplets. Analytical results have shown that droplet impingement angle relative to a receiving surface plays a key role in the surface damage. Although impacts with normal impingement angles contribute more severely to surface degradation than highly oblique angles, surface effects at higher impingement angles should not be dismissed. Thruster plume-induced materials degradation is a complex phenomenon that depends on a variety of parameters, including but not limited to material type, system temperature and pressure, plume composition, and thruster firing specifications such as number of pulses, pulse duration, and sample distance from the thruster. For space applications, attaining the vacuum pressure and temperature conditions necessary for flight-like plume expansion and exposure conditions is not a trivial task. The German Aerospace Center (Deutsches Zentrum für Luft- und Raumfahrt, DLR) is a facility uniquely capable of simulating such conditions. Test coupons were exposed to bipropellant thruster firings under high vacuum at the DLR facility. Percent area coverage (PAC) and droplet size distributions were evaluated for the uncoated and coated solar array coverglass materials over a range of impingement angles (0̊ to 75̊). A post-test imaging workflow was developed that aimed to quantify changes in sample surface morphology obtained from scanning electron microscopy (SEM) images using the Image Processing and Analysis in Java (ImageJ) tool; an opensource image processing software. The goal was to create a framework through which to evaluate the effect of bipropellant-induced PAC and droplet size distribution on solar array coverglass optical transmission losses. Understanding this relationship is important because optical transmission losses are known to lead to current reduction in solar power generation systems. In addition to the development of surface characterization workflows, valuable lessons learned as they pertain to future investigations and experiments will be discussed. The authors hope that sharing these lessons will facilitate more utilization of DLR’s unique capabilities as well as open the conversation for how best to address experimental characterization of flight-like plume expansion and its impacts on materials surface degradation effects.

Gateway↗

Solar cycle variation of thermospheric nitric oxide at solstice

A coupled, two-dimensional, chemical-diffusive model of the thermosphere is used to study the role of solar activity in the global distribution of nitric oxide. The model calculates self-consistently the zonally averaged temperature, circulation, and composition for solstice under solar maximum and solar minimum conditions. A decrease of the NO density by a factor of three to four in the E region is predicted from solar maximum to solar minimum. It is found that the main features of the overall morphology and the changes induced by the solar cycle are well reproduced in the model, although some details are not satisfactorily predicted. The sensitivity of the NO distribution to eddy transport and to the quenching of metastable N(2D) atoms by atomic oxygen is also described.

Gerard, J.-C.↗

Why convective heat transport in the solar nebula was inefficient

The radial distributions of the effective temperatures of circumstellar disks associated with pre-main sequence (T Tauri) stars are relatively well-constrained by ground-based and spacecraft infrared photometry and radio continuum observations. If the mechanisms by which energy is transported vertically in the disks are understood, these data can be used to constrain models of the thermal structure and evolution of solar nebula. Several studies of the evolution of the solar nebula have included the calculation of the vertical transport of heat by convection. Such calculations rely on a mixing length theory of transport and some assumption regarding the vertical distribution of internal dissipation. In all cases, the results of these calculations indicate that transport by radiation dominates that by convection, even when the nebula is convectively unstable. A simple argument that demonstrates the generality (and limits) of this result, regardless of the details of mixing length theory or the precise distribution of internal heating is presented. It is based on the idea that the radiative gradient in an optically thick nebula generally does not greatly exceed the adiabatic gradient.

Cassen, P.↗

Development of an Interactive Valuation Model for Distributed Energy Resource Value

The Oklahoma Secretary of Commerce & Tourism (OSCT) seeks to address perceived challenges and barriers to the deployment of distributed energy generation resources (DERs), including solar and other technologies, in the state of Oklahoma. The Scope of Work (SOW) outlines follow-on tasks related to the previous CRADA # CRD-18-762. The first task will finalize the Interactive Valuation Model Requirements Document, the final draft of which was provided in June 2018. The second task includes the building, validation, and finalization of the interactive valuation model for expressing distributed energy resource value based on user inputs to be completed by June 30, 2019. Training for how to prepare the data inputs and use the model will also be provided. To address perceived challenges and barriers to the deployment of distributed energy generation resources (DERs), including solar and other technologies, in the state of Oklahoma, the work under this CRADA will: 1) finalize the draft Interactive Valuation Model Requirements Document delivered in June 2018; 2) finish building and validating the interactive valuation model for expressing DER value based on user inputs, and 3) provide training for use of this model.

14 SOLAR ENERGY↗

Minnesota Solar Pathways: Illuminating Pathways to 10% Solar (Final Technical Report)

The Minnesota Solar Pathways project, funded in part by the Department of Energy’s Solar Energy Technologies Office, was a three-year project designed to explore least-risk, best-value strategies for meeting the State of Minnesota’s solar goals. As part of this aim, the Pathways Team modeled renewable generation costs, examined ways to streamline interconnection, and evaluated technologies that can increase solar hosting capacity on the distribution grid. Midway through the project period, the Pathways Team expanded the scope of study using the same modeling framework from the Minnesota Solar Potential Analysis to estimate and compare generation costs for high renewables penetration scenarios across the Midcontinent Independent System Operator (MISO) region. The analysis concludes that it can be cheaper to overbuild solar + wind and curtail surplus than to store all generation. In addition, the analysis of individual MISO subregions compared with the whole region highlights the opportunities of enabling market potential compared with impact of ongoing transmission constraints. Beyond the analysis of future scenarios, the partnerships initiated and supported through this project underscored the ongoing need for work with stakeholders to address key issues, particularly around siting, and leverage symbiotic strategies to meet state goals.

14 SOLAR ENERGY↗

Designing an Epitaxially-Integrated DBR for Dislocation Mitigation in Monolithic GaAsP/Si Tandem Solar Cells

This work explores epitaxially-integrated distributed Bragg reflectors (DBR) as a strategy to mitigate the impact of threading dislocations on the performance of monolithic GaAs 0.75 P 0.25 /Si tandem solar cells. The constraints present due to materials availability and the optical transmission profile of the GaAs 0.75 P 0.25 top cell require the use of an enhanced bandwidth DBR design achieved by combining two narrow-band DBR’s with different central wavelengths. Here, the impact of this DBR structure on JSC, along with the competing effects of threading dislocation density (TDD), are investigated using a robust, experimentally informed analytical model. Implementing this DBR within the GaAs 0.75 P 0.25 /Si tandem cell structure is predicted to yield a short circuit current enhancement equivalent to an ~1.8× reduction in TDD, providing a clear demonstration of its promise as a design methodology for mitigating the impact of non-negligible defect populations.

14 SOLAR ENERGY↗

The Ca II emission lines of SN 1987A

We study the evolution of the forbidden Ca II 7300 A and Ca II 8600 A emission lines in the spectrum SN 1987A. We can explain the observations with a model in which (1) the lines come from about 1.7 x 10 exp -4 solar mass of calcium distributed with filling factor about 0.1 in a sphere expanding with velocity 2500 km/s; (2) the electron number density is given by 4 x 10 exp 9/cu cm/(t/100d)-cubed; (3) the gas temperature decreases from T roughly 6400 K at 200 days to T roughly 3900 K at 500 days; and (4) ultraviolet pumping in the Ca II 3934 A, 3969 A (K, H) lines is required to explain the line ratios for t greater than about 350 days. The mass of calcium in our model is consistent with the LMC abundance of calcium in about 5 solar mass of hydrogen in the inner envelope of SN 1987A. If more calcium is produced by supernova nucleosynthesis, it must be in dense clumps that are too cool to emit the forbidden Ca II 7300 A and Ca II 8600 A lines.

Li, Hongwei↗

Field Demonstration of Inverter-based Voltage Management using Extremum Seeking Control

The influx of Distributed Energy Resources (DER) throughout the distribution system presents a challenge and an opportunity for maintaining power quality standards throughout the system. As such, DER Management systems have become a burgeoning field in both industry and academia. This work presents results from a field test of a model-free, distributed control approach, Extremum Seeking, applied to voltage management on a live feeder in Riverside, CA. The paper presents selected results to highlight the successes and challenges the control approach faced. The work shows that despite slow inverter response, extremum seeking control is able to drive voltage toward a target without knowledge of the system it is operating on.

14 SOLAR ENERGY↗

Isotopic signatures as tools to reconstruct the primordial architecture of the Solar System

The significant reorganization of the early Solar System due to giant planet migration has hampered our understanding of where planetary bodies formed. Previously employed proxies for reconstructing the primordial planetary architecture, such as water content or oxidation state, are complicated by post-accretionary processes. Furthermore we investigate basaltic achondrites for their nucleosynthetic isotope signatures in the elements neodymium (Nd) and zirconium (Zr) and show that they are—similar to previously investigated chondritic meteorites—characterized by a relative deficit in isotopes produced by the s-process of nucleosynthesis. Importantly, these data are well correlated with nucleosynthetic signatures observed in other elements, demonstrating that s-process matter was heterogeneously distributed throughout the early Solar System. By comparing these isotopic signatures with potential proxies for Solar System reconstruction and computer modeling, we here argue that this isotopic heterogeneity in bulk meteoritic materials is linked to the original heliocentric distance of formation. Such scaling of nucleosynthetic signatures with heliocentric distance could permit reconstruction of the primordial architecture of the Solar System by ‘cosmolocating’ the accretion orbits of meteoritic parent bodies as a function of incorporated s-process matter.

58 GEOSCIENCES↗

Three-Dimensional Grid Visualization for Planning Activities: A Dubai Case Study

National Laboratory of the Rockies (NLR), in collaboration with the Dubai Electricity and Water Authority (DEWA) and Infra-X, has undertaken the Energy Visualization Analysis Project. The aim of this project is to enhance analytical and 3D visualization capabilities for distribution network planning and renewable energy integration. As modern grid continues to evolve with large-scale solar PV deployment and emerging distributed energy resources (DERs), the ability to effectively analyze, visualize, and communicate complex grid behaviors has become increasingly critical. The project focuses on developing empirical use cases based on real distribution feeder data and engineering workflows, ensuring the outcomes are directly aligned with operational environment. Through time-series power flow simulations and nodal hosting capacity analysis, the study quantifies the impacts of high PV penetration on voltage and thermal limits within representative 11 kV feeders. These analyses identify specific nodes and conditions where DER integration challenges arise. Furthermore, a Battery Energy Storage System (BESS) optimization algorithm was applied to determine the optimal size and placement of storage systems that can mitigate network constraints and enhance hosting capacity. The comparative results between base-case and BESS-augmented scenarios clearly demonstrate improvements in network stability and load management efficiency. In parallel, the NLR team developed an immersive 3D visualization framework, enabling interactive exploration of grid simulations using commodity head-mounted display (HMD) systems. This framework transforms conventional 2D simulation data into spatially intuitive visual environments - allowing engineers to analyze feeder conditions, PV hosting potential, and BESS effects in real time. This report represents the first foundational phase in establishing a visualization-driven analytical ecosystem. It provides a methodological foundation for data integration, visualization architecture, and simulation-based decision support, paving the way for large-scale adoption of immersive visualization across DEWA's Smart Grid Initiative, R&D activities, and future network resilience studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Neutral and ion-exospheres in the solar wind with applications to Mercury

Construction of a model neutral and ion exosphere for a planet weakly interacting with the solar wind. The model is constructed in general terms and is then specialized to possible neutral and ion exospheres for the planet Mercury. The neutral exosphere model allows for density and temperature variations and for rotation at the exobase. The ion exosphere is produced by ionization of the neutral exosphere in the solar wind, and its density distribution is obtained by solving the continuity equation in the drift approximation. Applying to Mercury a surface temperature distribution inferred from infrared data and a vanishing bound neutral flux at the base, He and He(+) density distributions are found. When the He atmosphere of Mercury is due entirely to the surface bombardment by solar wind He(2+), the resulting He(+) density is found to vary from 0.15 to 0.001 per cu cm over the range from 1.5 to 5 planetocentric radii on the dayside. These densities are found to be detectable by typical solar-wind plasma instruments.

Hartle, R. E.↗

On the use of maximum likelihood estimation for the assembly of Space Station Freedom

Distributed parameter models of the Solar Array Flight Experiment, the Mini-MAST truss, and Space Station Freedom assembly are discussed. The distributed parameter approach takes advantage of (1) the relatively small number of model parameters associated with partial differential equation models of structural dynamics, (2) maximum-likelihood estimation using both prelaunch and on-orbit test data, (3) the inclusion of control system dynamics in the same equations, and (4) the incremental growth of the structural configurations. Maximum-likelihood parameter estimates for distributed parameter models were based on static compliance test results and frequency response measurements. Because the Space Station Freedom does not yet exist, the NASA Mini-MAST truss was used to test the procedure of modeling and parameter estimation. The resulting distributed parameter model of the Mini-MAST truss successfully demonstrated the approach taken. The computer program PDEMOD enables any configuration that can be represented by a network of flexible beam elements and rigid bodies to be remodeled.

Taylor, Lawrence W., Jr.↗

Enhanced Control, Optimization, and Integration of Distributed Energy Applications (ECO-IDEA)

With support from the U.S. Department of Energy Solar Energy Technologies Office, the National Renewable Energy Laboratory (NREL) partnered with Xcel Energy, Schneider Electric, Varentec, and Electric Power Research Institute (EPRI) to meet the goals of the Enabling Extreme Real-Time Grid Integration of Solar Energy (ENERGISE) program. This project developed and validated an innovative data-enhanced hierarchical control architecture that enables the efficient, reliable, resilient, and secure operation of future distribution systems with a high penetration of distributed energy resources like solar energy. The architecture enables a hybrid control approach where a centralized control layer is complemented by distributed control algorithms for solar inverters and autonomous control of grid edge devices. It is fully interoperable and includes all the cybersecurity aspects necessary for reliable and secure system operation. The hybrid approach can seamlessly integrate multiple voltage-regulation technologies, both at central and grid-edge levels, which enables reliable and efficient system operation in the face of unpredictable conditions. The overarching goal of the Eco-Idea project is to develop, validate, and deploy a unique and innovative Data-Enhanced Hierarchical Control (DEHC) architecture that comprehensively addresses the formidable challenges associated with proliferation of high penetration of distributed PV such as reverse power flows, transients from variability of PV systems, feeder load balancing, and voltage stability. These issues are exposing the weaknesses of existing grid operations and controls - including, but not limited to, lack of grid situational awareness, heuristic and slow-acting control actions, latency of control for emergency situations, and points of failure in communications. The proposed architecture will comprehensively resolve the deficiencies of current operational settings - where monitoring and control solutions proposed across industry and academia may not be interoperable and may not coexist in the same system - and will enable an efficient, reliable, resilient, and secure operation of future distribution systems with penetration of solar energy well beyond current limits. The DEHC architecture was developed and validated rigorously through hardware-in-loop simulations in the laboratory environment and deployed on the field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS.

on-orbit calibration↗

SNPP VIIRS RSB on-orbit radiometric calibration algorithms Version 2.0 and the performances. Part II: The performances

In Part I (Lei et. al, submitted to J. of Appl. Rem. Sens.),we gave detailed reviews of the algorithms Version 2.0 used for the on-orbit radiometric calibration of the reflective solar bands (RSBs) of the first Visible Infrared Imaging Radiometer Suite instrument. These algorithms improve the accuracy of the measured on-orbit change factor of the solar diffuser bidirectional reflectance distribution function, the H-factor, and reveal that the H-factor is angle dependent. With the help of lunar observations and the improved H-factor, the algorithms give more accurate values for the RSB detector on-orbit F-factor changes (F-factor is a correction factor to the initially retrieved scene spectral radiance). In this paper we review the RSB radiometric calibration performances. We show the H-factor temporal trend, the estimated uncertainty of the retrieved H-factor, and the F-factor temporal trend. Additionally we show the detector signal-to-noise ratio (SNR), the estimated uncertainty of the top-of-the-atmosphere solar spectral reflectance, the reflectance temporal trend for the Libya 4 desert, and the differences in the reflectances among the SNPP and the NOAA-20 VIIRS, and the Aqua MODIS. Our results show that although the SNRs trend downwards, they exceed the requirements by large margins. The reflectances from the Libya 4 desert show that the SNPP VIIRS’ reflectance is higher than those of the Aqua MODIS and the NOAA-20 VIIRS

Ning Lei↗

Estimation of Behind-the-Meter Solar Generation by Integrating Physical with Statistical Models

Accurate estimation of solar photovoltaic (PV) generation is crucial for distribution grid control and optimization. Unfortunately, most of the residential solar PV installations are behind-the-meter. Thus, utilities only have access to the net load readings. This paper presents an unsupervised framework for estimating solar PV generation by disaggregating the net load readings. The proposed framework synergistically combines a physical PV system performance model with a statistical model for load estimation. Specifically, our algorithm iteratively estimates solar PV generation with a physical model and electric load with the Hidden Markov model regression. The proposed algorithm is also capable of estimating the key technical parameters of the solar PV systems. Our proposed method is validated against net load and solar PV generation data gathered from residential customers located in Austin, Texas. The validation results show that our method reduces mean squared error by 44% compared to the state-of-the-art disaggregation algorithm.

24 POWER TRANSMISSION AND DISTRIBUTION↗