Search NASA⌕ Search

SEARCH · Search NASA

Results for “Distribution Grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Use of the portable decay gamma source feature in the R2Smesh code system for the accurate estimation of photon radiation dose fields around activated ITER components - Paper 111

The R2Smesh ('Rigorous 2-step') code system, developed by KIT for the determination of shut-down dose rate distribution on mesh grid, can be utilized to provide photon radiation dose field around activated components which are moved from the irradiation site in fusion reactor to another external location. R2Smesh couples MCNP transport calculations and FISPACT inventory calculations through suitable interfaces utilizing MCNP mesh tally capability. Neutron flux and the decay gamma source are provided with high resolution on the mesh grid superimposed to the real geometry to take into account the spatial variations of the flux and the decay gamma source distributions. This feature enables the decay gamma source distribution to be transferred from the irradiation site in the reactor to any other external location for the determination of photon flux and dose rate distributions. In this work, we applied the feature of the portable decay gamma source in R2Smesh code system to a dose rate analysis for a tunnel connecting the ITER tokamak complex building (TCB) and the hot cell facility building (HCFB). This paper presents the use of the portability feature of the decay gamma source in R2Smesh interface code system developed by KIT for a dose rate analysis of the ITER tunnel connecting TCB and HCFB. This application shows that the decay gamma source of the activated components could be transferred successfully from one coordinate system to another coordinate system and superimposed to the geometry of the components. This is very useful when the activated components need to be transported from the reactor to somewhere else for maintenance, testing or storage and the dose rate analysis is requested. Another portable feature, which could convert the 3D decay gamma source distribution generated by R2Smesh system to the MCNP 'SDEF' card source description and avoid the use of source sampling subroutine, is under consideration. With this feature, one decay gamma source result for the specific reactor components could be shared by different institutions who need to use the same decay gamma source for different analysis. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimal Distribution System Voltage Regulation using State Estimation and DER Grid-Support Functions

Increasing solar energy penetrations may create challenges for distribution system operations because production variability can lead to large voltage deviations or protection system miscoordination. Instituting advanced management systems on distribution systems is one promising method for combating these challenges by intelligently controlling distribution assets to regulate voltage and ensure protection safety margins. While it is generally not the case today, greater deployment of power system sensors and interoperable distributed energy resources (DER)e.g., photovoltaic (PV) inverters, energy storage systems (ESS), electric vehicles (EVs)will enable situational awareness, control, and optimization of distribution systems. In this work, a control system was created which measures power system parameters to estimate the status of a feeder, forecasts the distribution state over a short-term horizon, and issues optimal set point commands to distribution-connected equipment to regulate voltage and protect the system. This two-year project integrated multiple research innovations into a management system designed to safely allow PV penetrations of 50% or greater. The integrated software was demonstrated through extensive real-time (RT) and power hardware-in-the-loop studies and a field demonstration on a live power system with a 684 kVA PV system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Geometric remapping of particle distributions in the Discrete Element Model for Sea Ice (DEMSI v0.0)

Abstract. A new sea ice dynamical core, the Discrete Element Model for Sea Ice (DEMSI), is under development for use in coupled Earth system models. DEMSI is based on the discrete element method, which models collections of ice floes as interacting Lagrangian particles. In basin-scale sea ice simulations the Lagrangian motion results in significant convergence and ridging, which requires periodic remapping of sea ice variables from a deformed particle configuration back to an undeformed initial distribution. At the resolution required for Earth system models we cannot resolve individual sea ice floes, so we adopt the sub-grid-scale thickness distribution used in continuum sea ice models. This choice leads to a series of hierarchical tracers depending on ice fractional area or concentration that must be remapped consistently. The circular discrete elements employed in DEMSI help improve the computational efficiency at the cost of increased complexity in the effective element area definitions for sea ice cover that are required for the accurate enforcement of conservation. An additional challenge is the accurate remapping of element values along the ice edge, the location of which varies due to the Lagrangian motion of the particles. In this paper we describe a particle-to-particle remapping approach based on well-established geometric remapping ideas that enforces conservation, bounds preservation, and compatibility between associated tracer quantities, while also robustly managing remapping at the ice edge. One element of the remapping algorithm is a novel optimization-based flux correction that enforces concentration bounds in the case of nonuniform motion. We demonstrate the accuracy and utility of the algorithm in a series of numerical test cases.

58 GEOSCIENCES↗

Air Conditioning Stall Phenomenon Testing, Model Development, and Simulation

Electric distribution systems are experiencing power quality issues of extended reduced voltage due to fault-induced delayed voltage recovery (FIDVR). FIDVR occurs in part because modern air conditioner (A/C) and heat pump compressor motors are much more susceptible to stalling during a voltage sag or dip such as a sub-transmission fault. They are more susceptible than older A/C compressor motors due to the low inertia of these newer and more energy efficient motors. There is a concern that these local reduced voltage events on the distribution system will become more frequent and prevalent and will combine over larger areas and challenge transmission system voltage and ultimately power grid reliability. The Distributed Energy Communications and Controls (DECC) Laboratory at Oak Ridge National Laboratory (ORNL) has been employed to (1) test, (2) characterize and (3) model the A/C stall phenomenon.

air conditioning stall↗

Three-dimensional grids as solutions of elliptic systems

An elliptic grid generation scheme is described which produces a curvilinear, boundary-fitted grid for highly swept wings with sharp leading edges. The three-dimensional integration domain is segmented in successive crossflow sections wherein the physical coordinates are transformed to computational coordinates by solving an elliptic set of two quasi-linear differential equations. Grid points are clustered in the vicinity of the wing surface, especially in the neighborhood of the leading edges. The formulation of the source terms in the equations governing the transformation contains adjustable parameters which are determined from limiting forms of the elliptic equations along the boundaries. The source terms are assigned to each grid point by interpolation of these parameters into the interior domain. The formulation does not depend on the boundary shape or on the distribution of the grid points along the boundaries. For the first time, the discretized governing equations have been solved using a fast AF1 iteration scheme.

Hartwich, P.-M.↗

Megawatt-Class, High-Voltage SiC Power Electronics Converters for Advanced Manufacturing with Grid Support Services

DE-EE0009135 aimed to push the 10kV SiC MOSFET based power electronics to 3-phase 13.8kV 10MW to be used as a Megawatt Class Medium-Voltage Power Conditioning Systems – PCS – to enable “Resilient Distribution through Grid-dispatching and Uninterrupted Quality Power to Manufacturing Facilities” during transitory grid disturbances. As a stretch to those goals, Eaton added the load power peak shaving opportunity.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hierarchical Control and Stability Analysis for a Nonisolated Grid-Tied DC Energy Router Integrating Energy Storage and Partial Distributed Generation

This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.

25 ENERGY STORAGE↗

Blockchain Smart Contracts for Transactive Energy Systems

This report demonstrates the impact of blockchain technology underlying a transactive energy system and articulates details and principle components of each of five stages in a transactive energy system. This report depicts the engineering requirements of a sample market system, blockchain features, and the relationship between those requirements and features (Section 2.2). Clear value propositions of blockchain features for transactive energy systems are: identity management, security of data, resiliency, decentralization and smart contract trustworthiness, performance, integrity in a trustless environment and access control. Due to the immutability afforded by blockchain architecture, increased data fidelity could potentially help detect targeted cyber-attacks and increase resiliency of grid integration. A distributed system can be more fault tolerant and enable transactive energy by supporting machine-to-machine transactions that can be integrated directly into complex grid operations without the need of trust in a third party. Energy auctions, and potentially registration processes, can be carried out according to transparent rules implemented as smart contracts (Section 4.0). In this current experiment, we ran a use-case/table-top exercise that imitated a real-time 5-min double auction market. The objective of this demonstration is to investigate the applicability of blockchain with transactive energy systems (Section 3.0).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solar Power and the Electric Grid, Energy Analysis (Fact Sheet)

In today's electricity generation system, different resources make different contributions to the electricity grid. This fact sheet illustrates the roles of distributed and centralized renewable energy technologies, particularly solar power, and how they will contribute to the future electricity system. The advantages of a diversified mix of power generation systems are highlighted.

14 SOLAR ENERGY↗

Advancing Electric System Resilience with Distributed Energy Resources: A Review of State Policies

Severe weather, cyber-attacks, geomagnetic disturbances, and other hazards and threats have caused or have the potential to cause substantial levels of damage to electricity infrastructure and the global economy. Growth in distributed energy resources (DERs) and increasing attention to the resilience of the electric grid - its ability to "anticipate, absorb, adapt to, and/or rapidly recover" from disruptions, according to the Federal Energy Regulatory Commission (FERC, 2018) - have created an opportunity for energy stakeholders to develop and deploy "resilient DERs," resources in the distribution grid that improve the ability of a customer, critical facility, and/or the distribution system in general to anticipate, absorb, adapt to, and/or rapidly recover from disruptions. This paper explores how existing state regulations intersect with resilience and highlights opportunities where state regulators can employ DERs to advance resilience.

14 SOLAR ENERGY↗

OCHRE: The Object-oriented, Controllable, High-resolution Residential Energy Model for Dynamic Integration Studies

Electrification and the growth of distributed energy resources (DERs), including flexible loads, are changing the energy landscape of electric distribution systems and creating new challenges and opportunities for electric utilities. Changes in demand profiles require improvements in distribution system load models, which have not historically accounted for device controllability or impacts on customer comfort. Although building modeling research has focused on these features, there is a need to incorporate them into distribution load models that include DERs and can be used to study grid-interactive buildings. In this paper, we present the Object-oriented, Controllable, High-resolution Residential Energy (OCHRE) model. OCHRE is a controllable thermal-electric residential energy model that captures building thermal dynamics, integrates grid-dependent electrical behavior, contains models for common DERs and end-use loads, and simulates at a time resolution down to 1 minute. It includes models for space heaters, air conditioners, water heaters, electric vehicles, photovoltaics, and batteries that are externally controllable and integrated in a co-simulation framework. Using a proposed zero energy ready community in Colorado, we co-simulate a distribution grid and 498 all-electric homes with a diverse set of efficiency levels and equipment properties. We show that controllable devices can reduce peak demand within a neighborhood by up to 73% during a critical peak period without sacrificing occupant comfort. We also demonstrate the importance of modeling load diversity at a high time resolution when quantifying power and voltage fluctuations across a distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Final Report - Center for Grid Modernization

The objective of the CGM was to develop high-priority grid modernization technologies in advanced sensors, communications, controls and smart systems to enable use of real-time or near real-time information for monitoring, analyzing and managing distribution and transmission grid conditions. The key strategic approach to carry out individual CGM research and development (R&D) projects was through partnerships, primarily with the GridApp™ Consortium utility members.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distributed Conditions for Small-signal Stability of Power Grids and Local Control Design

Operating modern power grids with stability guarantees is markedly important. Typical methods for analyzing and certifying power grid stability are largely centralized relying on the ability of the system operator to gather network-wide information and accurately compute the system's eigenvalues. These methods are oftentimes not privacy-preserving and computationally burdensome. They are therefore, not well-suited to modern power grids where small-signal stability has to be evaluated timely, efficiently and in a privacy-preserving fashion. Herein, we introduce a distributed methodology for certifying small-signal stability of power grids and designing the local controllers. First, we analytically derive distributed conditions for network-wide stability that bus agents can inspect using local information. By leveraging these conditions, we then introduce a distributed control design algorithm (DCDA) that can guide the local control design so that stability of the interconnected system is guaranteed. The agents that adopt the proposed distributed algorithm are responsible for tuning their local controllers, producing their local control commands and ensuring that their local stability condition is met. The system operator is only responsible for verifying network-wide stability upon receiving affirmative responses from all agents and, announcing, that the overall system is stable. The proposed DCDA algorithm is numerically validated via simulations using the IEEE 39-bus system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Distribution System Planning - State Examples by Topic

The U.S. Department of Energy (DOE) recently completed a study on how regulators in 16 states have dealt with questions related to distribution system planning (DSP) and distributed energy resource (DER) utilization. During the study, DOE and three of its national laboratories developed a significant amount of information on state-level activities including grid modernization planning; distribution planning; tools for integrating distributed energy resources (DERs) (e.g., hosting capacity analysis and tools for maximizing the value of DERs to the distribution system such as locational value analyses); and linkages between distribution planning and related processes such as cost recovery through general rate cases or rate surcharges. The Oregon Public Utility Commission (Commission) requested assistance from DOE on a list of specific questions related to DSP. The Commission was specifically interested in identifying guidance on the creation of comprehensive and transparent utility distribution system plans; on the linkages between such plans and other utility planning processes such as integrated resource planning; improved forecasting and representation of DERs in distribution system plans and other plans such as integrated resource planning; valuation of DERs; and a roadmap for optimized locational planning for DERs. In response to their interests, we have identified 1) specific topics from the original study that would be of assistance to the Commission and 2) states that could provide potential examples or templates to draw from. In this report, we have summarized and reorganized the pertinent original material by subject. We also developed a matrix that points to specific examples for each topic and provide one or two paragraph summaries of each possible template for each topic area with web links directly to the source documents. For some cases in which states have taken significant steps since the publication of the original DOE study, the original source information has been supplemented to ensure the information provided to the Commission remains current. Finally, we called out a small number of especially pertinent or immediately useful documents and have highlighted these in the introductory section. This report documents the material developed for the Oregon Commission by DOE.

24 POWER TRANSMISSION AND DISTRIBUTION↗

State of Common Grid Services Definitions

This document is prepared as part of the Department of Energy’s Grid Modernization Laboratory Consortium (GMLC) 2.5.2 project, whose goal is to develop and socialize a common set of grid service definitions relevant to grid-related interactions with distributed energy resources (DER: responsive generation, storage, and loads), and to advance the concept and requirements of the Energy Services Interface (ESI) to the point of launching related interface standards and guides that can be implemented in communication protocols and business process definitions. The notion of “grid services” is integral to the definition of an ESI because a key principle of the ESI is that it permits coordination between grid operators and DER facilities in a way that is service-oriented, with an understanding of performance expectations. This document reviews the current state of grid service definitions, including those actively used in the market today as well as new services that have been proposed for future implementation. The document describes grid services used in transmission as well as distribution systems. In defining grid services, this document also distinguishes between two fundamental concepts: an “operational objective” and a “grid service,” which describes a generator’s or customer’s expected physical performance in delivering power to or consuming power from the grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Resiliency with a 100% Renewable Microgrid

San Diego Gas & Electric Company (SDG&E) installed America’s first and largest utility-scale microgrid in Borrego Springs in 2013. The first generation Borrego Springs Microgrid utilized diesel generators to form and stabilize the microgrid island, with support from grid-scale batteries and local solar photovoltaic (PV) generation. In this project, SDG&E in partnership with National Renewable Energy Laboratory (NREL) demonstrated through modeling, simulation and utility field testing that blackstart and islanding of the microgrid can be led with 100% renewable, inverter based resources (IBRs), to help reduce community reliance on conventional generation resources. Through equipment upgrades, grid-forming island leader capability was transitioned to a battery IBR instead of the Borrego Springs Microgrid diesel generators. A new microgrid controller was integrated to the microgrid and programmed to control and manage multiple energy storage systems. Synchrophasor and other power quality data verified autonomous, high-speed response of the IBRs through blackstart, islanding, and load step testing. Results of project field evaluations provide distribution systems operators (DSO) with increased confidence that renewable, IBR can replace traditional generators to blackstart and island microgrids and rapidly establish stable island frequency with rapid changes in peak power demand. Importantly, the project validated the integration feasibility of a distributed energy resource management system (DERMS) controller that manages multiple grid-forming and grid-following IBRs, establishing a standard design interface to reduce the complexity of integrating new DERs in the future and supporting replication by the industry. As a result of learnings in this project, SDG&E has implemented the microgrid controller strategy at multiple other microgrid sites, thereby validating the replicability of the solution. Hardware-in-the-loop (HIL) simulations including power and controller HIL hardware — along with electromagnetic transient (EMT) simulations of Borrego Springs Microgrid —informed adjustments to inverter parameters and were important to characterize the performance of the IBRs in relevant operating conditions before deployment. The EMT and HIL simulations of islanding the entire community are important contributions in providing confidence in IBR performance prior to future islanding of the community in the field. High-fidelity EMT and/or HIL simulation of IBRs can de-risk field operations, and its relevance and importance as a tool is increasing as distribution grids and microgrids become more complex and dynamic with an increasing proportion of renewable generation, distributed energy storage, and two-way power and energy flows.

24 POWER TRANSMISSION AND DISTRIBUTION↗