Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVACUATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Numerical Implementation of Source Terms to Evaluate Active Porosity Control using a Transpiration Cooled Thermal Protection System

Transpiration cooling has renewed interest of study as a renewable system of thermal protection for atmospheric entry systems. The presence of coolant within the void space of a porous material changes its effective porosity and theorized to lend the external heatshield as a potential means of porous surface control. Effective porosity is explored in two forms: saturation of void space where exiting coolant creates ‘blowing’ over the surface, and partial evacuation of the void space where withdrawal of the coolant creates ‘suction’ on the surface. Thus this study evaluates using transpiration cooling as a as means of active aerodynamic control. The feasibility of the system is evaluated numerically using Reynolds-averaged Navier Stokes based computational fluid dynamics for the aerodynamic assessments by coding source terms of transpiration cooling products at a heat shield surface boundary at the wind side shoulder, creating an asymmetric scheme. Study results show induced moments about the pitch axis incurred following the source terms of a cooling fluid at a near-shoulder location on the heat shield. Lift and drag saw increasing modulation with increase in mass flux rate. Pitch moment was altered a total of 388 N-m between lowest and highest ‘suction’ rates and changed 194 N-m maximum between ‘blowing’ rates.

transpiration cooling↗

Comparison of Artemis 2 and Artemis 5 Model Outcomes Using the Impact Probabilistic Risk Assessment Tool

BACKGROUND The Artemis campaign is a Moon exploration program with a series of six planned missions, five of which will be crewed. These five crewed missions will contain a single mission segment (space flight), or multiple mission segments involving space flight (Orion), lunar landing (LTV) and/or space habitat (Gateway). Each crewed segment faces the risk of unique medical conditions, necessitating medical sets/kits tailored to those specificities. To support and enable a data-driven and evidence-based decision-making process through out a mission’s life cycle, a software tool called IMPACT was developed. Using probabilistic risk assessment (PRA) methodologies, IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a novel tool built for analyzing the possibility of encountering complex medical risks during space flight, and for identifying the medical resources and capabilities needed to treat those potential at-risk medical conditions. This presentation will seek to compare IMPACT’s computational results upon potential complex space medical conditions (e.g., sprain/strain back or sleep disturbance) using IMPACT’s risk metrics and the associated optimized medical sets/kits between two Artemis missions: single segment Artemis 2 and multi-segmented Artemis 5. OVERVIEW By identifying potential medical conditions in space using input criteria such as crew quantity and composition, certain crew physical characteristics, mission duration and mission activities, IMPACT can produce analyses on the type of medical resources and capabilities needed to produce an optimized medical set/kit to address those medical conditions. IMPACT achieves this by performing hundreds of thousands of Monte Carlo simulations of missions to build aggregate pictures of medical risk. IMPACT’s risk metrics include loss of crew life (LOCL) – a measure of crew mortality due to medical conditions in space, return to definitive care (RTDC) – the need to perform crew evacuation, and task time lost (TTL) – a measure of the inability to perform activities due to crew disability. These risk metrics are applied to every medical condition identified by IMPACT’s computation analyses for every segment of the mission. Medical sets/kits are optimized to address these medical conditions but must fit within the stated Artemis Design Reference Mission (DRM) request for mass and volume physical size constraints. ANTICIPATED ANALYSIS AND CONCLUSION Using two Artemis missions, Artemis 2 and Artemis 5, IMPACT will provide the analyses for comparison of medical set/kit contents based upon mass and/or volume requirements and identify the at-risk medical conditions within both missions. This paper serves as an initial exploration of probabilistic risk assessment (PRA) medical risk calculations between two crewed Artemis missions and is not intended to be deemed the official medical response for the Artemis campaign.

probabilistic risk assessment↗

Evaluating the Viability of Compact and Portable X-Ray Systems for an Exploration Medical System in a Ground Demonstration

MOTIVATION FOR INCLUDING X-RAY CAPABILITIES For upcoming exploration missions, the need for enhanced medical care becomes critical due to extended mission durations, significant communication delays, and minimal evacuation opportunities. Previous evidence by our team has revealed that among the 119 medical conditions targeted for management during spaceflight within NASA Exploration Medical Capability’s IMPACT Condition List, at least 36 could benefit from radiography (XR). Utilizing XR for diagnosis and management is hypothesized to significantly improve management of crew health by enabling the immediate evaluation and confirmation of potential injuries or illnesses. Beyond clinical applications, XR also holds potential for non-destructive testing (NDT). This includes applications such as assessing the structural integrity of the spacecraft, analyzing surface and meteorite samples, and inspecting onboard electronics. THREE CANDIDATE X-RAY SYSTEMS CHOSEN FOR GROUND DEMONSTRATION The Exploration Medical Capability Element (ExMC) and the Exploration Medical Integrated Product Team (XMIPT) of the Mars Campaign Office initiated early background work for ground demonstrations. In FY21, ExMC published a Concept of Operations to guide requirements development. By FY23, XMIPT and yet2, a technology scouting and open innovation consulting firm, had completed a market survey and trade study to identify potential miniature XR systems. Selection criteria included commercial-off-the-shelf availability, low mass and volume, and regulatory compliance. The top three candidate devices—Remedi REMEX-KA6, MinXray Impact, and FujiFilm Xair—were acquired to characterize the requirements and capabilities of each device. To facilitate testing, phantoms, and radiographic personal protective equipment (PPE) were purchased, and a dedicated space was designated for XRS usage at Glenn Research Center. During this presentation, the mass, volume, and power requirements for each of the three piloted devices are revealed, as well as information regarding the detector, mA, and kV of the devices. GOAL AND OBJECTIVES OF A MINI XRS GROUND DEMONSTRATION The primary goal of ExMC/XMIPT technology demonstrations is to bridge the gap in available, flight-ready medical device technology by flight-testing diagnostic and treatment technologies essential for managing medical conditions during exploration missions. These technologies must adhere to vehicle constraints such as mass, volume, power, and data requirements, integrate seamlessly with medical decision-support tools, and support increasingly Earth-independent operations. There are three main objectives for the future ground demonstration of these three devices. First, we aim to determine the full capabilities of these three miniature XR systems within the context of the spaceflight environment. While medical applications are the primary focus for the miniature XR, a comprehensive exploration of non-medical uses has been initiated by an XMIPT-sponsored NASA SPARK campaign to identify collaborators. Second, we plan to establish criteria and to use insights gained from evaluating each miniature XR against those criteria to select the most suitable system among the three candidates. Third, we intend to evaluate their suitability for flight certification, which includes assessing its durability for launch, reentry, and exposure to high background radiation, as well as its compatibility with existing data architecture systems. Numerous subject matter experts from NASA and partner institutions will support these objectives.

C A Haddix↗

Human Spaceflight Applications of Novel Miniature X-Ray Technologies

INTRODUCTION: Radiography (XR) has long been a cornerstone of terrestrial medical imaging, though it has not yet been used in the spaceflight environment. Medical systems for human spaceflight missions are constrained by mass, volume, and power, and until recently, XR systems have been considered too large and power-consuming for spaceflight diagnostic and therapeutic applications. However, the rise of commercial spaceflight and NASA’s refocused efforts on returning crews to the Moon for long-duration missions have introduced a higher degree of medical risk to human spaceflight and require a re-evaluation when optimizing medical system design. Over the last decade, XR devices have miniaturized while maintaining good diagnostic and therapeutic sensitivity and specificity, making new in-flight medical and non-medical XR applications a possibility. Initial research identified several medical conditions where miniature XR would be beneficial for the diagnosis and/or management of medical conditions arising in space, though a more in-depth analysis is required to identify whether XR may add value to the management of such conditions. With this presentation, we aim to introduce the potential utility of miniature XR, review prior work highlighting where XR may be beneficial, and evaluate how miniature XR may reduce medical risk in human spaceflight missions. METHODS: IMPACT (Informing Mission Planning via Analysis of Complex Tradespaces) is a risk assessment tool developed by NASA to advance exploration mission medical system design by quantitatively estimating mission medical risk. IMPACT v1.0 includes a novel evidence library baselined to exploration environments, an expanded list of 119 medical conditions, medical capabilities and resources critical for management of these medical conditions, and the ability for rapid and iterative analysis in the setting of modifiable design reference missions (DRMs). Our first analysis identified which of the 119 medical conditions XR had diagnostic or therapeutic utility for. Subject matter experts (SMEs) recorded which XR views would be performed under ideal terrestrial circumstances for diagnosis/management of each condition, as well as which views are pragmatic for spaceflight limitations. A second analysis utilized IMPACT to identify significant conditions that contribute greatest to medical risk during a notional long-duration Lunar orbit and Lunar surface DRM. Medical system risk estimates include loss of crew life (LOCL), need for return to definitive care (RTDC; medical evacuation), and an estimate of crew task time affected (TTA). Using a standardized semi-quantitative scoring methodology, a deeper evaluation of each of the most significant medical conditions was performed. Data from both of these separate analyses were used to hypothesize what ideal and pragmatic XR studies may impact clinical management of the most significant conditions predicted to lead to medical risk. RESULTS: Approximately 1/3 of the IMPACT conditions were identified as being more effectively or comprehensively assessed or treated with the addition of miniature XR technology. The resulting conditions benefitting diagnostically and therapeutically from XR are revealed, as well as the ideal and pragmatic XR views and medical procedures benefitting from XR. The conditions of clinical significance and those most contributing to risk are also displayed. Among the conditions that contribute greatest to LOCL, four conditions for which XR may improve the diagnosis and management of include: decompression sickness, traumatic shock, dental abscess, and respiratory failure. Among conditions that contributed to RTDC, the evaluation and management of wrist fracture is likely improved by XR. For conditions leading to crew TTA, evaluation and management of EVA shoulder injuries, upper and lower extremity strains, back strains, and EVA hand injuries are likely improved by XR. DISCUSSION: Miniature XR in spaceflight has the potential to improve the evaluation and management of a substantial portion of conditions that most contribute to medical risk. This presentation is an introduction to the possibilities miniature XR provides for future human spaceflight missions and subsequent presenters will expand on potential applications in more detail. LEARNING OBJECTIVES: 1) Understand the previous limitations of using radiography in the management of spaceflight medical conditions; 2) Evaluate the findings from the IMPACT tool analysis, which allows quantification of the benefit miniature XR could provide for managing high-risk medical conditions in long-duration lunar orbit and surface missions, focusing on improvements in crew health outcomes; 3) Analyze case studies where miniature XR technology could reduce the medical risks associated with spaceflight missions, specifically in diagnosing and managing conditions such as decompression sickness, traumatic shock, and EVA-related injuries.

A Anderson↗

Earth-Independent Medical Operations (EIMO) Concept of Operations

In contrast to the current crew health paradigm for low-Earth orbit and Lunar missions, which depends on real-time communication with Mission Control, deep-space exploration missions will require a significant shift in medical operations. This shift is driven by the constraints of operating at a considerable distance from Earth, such as resource limitations—lack of resupply, restricted mass, power, volume, and data—as well as communication delays and the inability to evacuate back to Earth during emergencies. To move toward a more self-reliant medical model, a strategy is needed to gradually increase space-based crew autonomy and reduce risks to mission success in the challenging environment of deep space. This transformative change, known as "Earth-Independent Medical Operations" (EIMO), explores the gradual transfer of medical care and decision-making from Earth-based support to space-based systems. The goal of this transition is to enhance astronaut health and performance while minimizing mission risks. EIMO requires the development of a medical system that integrates seamlessly with mission planning, vehicle and spacesuit design, and data architecture. This integration is crucial for building a robust medical infrastructure that not only safeguards astronaut well-being but also ensures overall mission success. The Human Research Program (HRP) Exploration Medical Capability (ExMC) Element has revised the EIMO model-based Concept of Operations (ConOps) which outlines an initial vision for EIMO. The ConOps, which is built on the stakeholders’ need, system goals, and objectives (NGOs), presents an array of in-mission scenarios that span a wide range of medical conditions demonstrating the system’s capabilities from basic to complex events. Developed by a multidisciplinary team of systems engineers, scientists, and clinicians within ExMC, the ConOps revision includes two new scenarios(Barotrauma and Self-Medical Management and Behavioral Health and Chronic Medical Care), and implementation of findings from EIMO technical interchange meetings that focused on data and training. The envisioned EIMO Medical System (MS) operates as a system of systems, gathering data from various sources such as reference databases, real-time wearable sensors, point-of-care diagnostics, and environmental controls. The MS also incorporates advanced training tools to support autonomous medical care, assisting the Crew Medical Officer (CMO) during medical events where Ground Support is either unavailable or communication-delayed beyond practicality. Furthermore, MS functions and capabilities were decomposed from the scenarios to establish foundational requirements for EIMO and traced to the NASA Spaceflight Human-System Standard(NASA-STD-3001, Volumes 1 and 2). These traces were performed to gain insights on the alignment of EIMO requirements with the NASA standard. This work serves as an initial recommendation to increase crew autonomy gradually and safely for Mars missions and future deep-space exploration.

medical system↗

The Future of Integrated Performance Modeling in the Crew Health and Performance – Probabilistic Risk Assessment Project

The NASA engineering community utilizes event-driven and fault-tree probabilistic techniques to classify risks in the space environment by taking advantage of the inherent knowledge of complex spaceflight system design and testing to quantify failure risk. In harmonizing the risk of human space flight, answering the question of ‘How do we balance health, performance and resource risks with other engineering risks on long duration space missions?’ remains a deeply challenging and largely qualitative practice. The Human Research Program’s Medical Extensible Dynamic Probabilistic Risk Assessment Tool (MEDPRAT) was a significant step forward in efforts to robustly quantify the risk to crew health for exploration missions. However, there remains a significant gap in the ability to comprehensively assess and characterize risk across the disparate functionalities and capabilities which comprise the Crew Health and Performance (CHP) system. The Crew Health and Performance – Probabilistic Risk Assessment (CHP-PRA) project seeks to characterize CHP risks by expanding beyond the foundation established by its PRA predecessors like IMM and MEDPRAT, that simulate medical risk metrics like loss of crew life and evacuations. One of the new risk measures in the CHP-PRA system is embodied in our Performance Risk Model (PRisM). PRisM provides a novel way of assessing crew performance on mission tasks, using a generalized framework which relates back to NASA-STD-3001. This approach allows PRisM to capture and integrate data from a variety of different domains into a single, unified, reproducible representation of astronaut performance. In this presentation, we discuss the motivation for the CHP-PRA work and give a high level overview of the goals of the project, outline the forward work for PRisM, and discuss collaboration opportunities for the community who might explore if their domain knowledge and data could be represented, integrated, and quantified with these tools, whose outcomes are metrics useful for supporting operational mission planning and decision making.

Lauren McIntyre↗

Content and Representation of Information Needed to Support Time-Constrained Problem Solving

NASA’s current mission-operations paradigm originated with Project Mercury and endured with minimum evolution through the Apollo Program, Space Shuttle Program, and ISS missions. At its foundation is a near-complete real-time dependence on a ground team to manage the combined state of the mission, vehicle, and crew. Utilizing many engineers and operators with broad and deep expertise; large, distributed datasets including extensive telemetry; and expansive analytical and computing power, this ground team has served as the safety net for crewed spaceflight missions over the past 60 years. This approach must change to address challenges associated with missions beyond low Earth orbit (BLEO), including infrequent resupply, reduced ability to evacuate, and delayed communications that prohibit real-time operational support. We anticipate that a necessary part of this change will be increased independence for the crew, as roles and responsibilities traditionally performed by ground teams move on board the vehicle. While many risks are associated with Earth-independent operations, one particular concern is ensuring that the crew will have adequate onboard support to perform urgent problem solving when communication with the ground is delayed or intermittent. A key resource that enables the ground team to respond to anomalies quickly and effectively is the extraordinary expertise and experience it possesses. It is comprised of 80+ experts on at any given time, with a combined 600+ years of system-specific experience across 22 unique console disciplines. A small crew will face the unprecedented challenge of independently responding to anomalies that have historically been handled by a team 20 times their size. Another important resource upon which the ground heavily relies to support procedure execution and anomaly response is data. The amount of telemetry data that each flight controller monitors is extensive. In addition, as the ground team works to further assess impacts, trouble shoot, identify workarounds, and oversee procedure execution, it accesses and synthesizes engineering and procedure information, as well as system build, test, and configuration documentation. It is not feasible nor useful to put all these data onboard as crews become more Earth independent. Each member of a small Mars mission small crew will have multiple roles beyond monitoring telemetry and data gathering, and multiple roles within anomaly resolution processes, thereby limiting their capacity for copious amounts of information. Moreover, while access is necessary, it alone is insufficient. Information will need to be compiled, refined, and represented appropriately to support the crew’s reduced attention and expertise. This work seeks to understand the content and representation of information needed to support time-constrained problem solving and decision making by the crew without real-time ground support. To build this understanding, we first surveyed the literature, focusing on how expert problem solvers construct and manipulate their mental models. Next, we interviewed expert problem solvers in spaceflight and analogous domains and surveyed industry solutions for data presentation. Finally, we analyzed current spaceflight operations by investigating flight controller anomaly resolution processes during ISS training simulations and real operational events. These methods led to creating a problem-solving framework that details common themes and features of attending to, assessing, analyzing, and acting on problems in complex, time-constrained domains. Using this framework and the results of our analysis, we identified conceptual data representations needed for crew-led problem-solving. Preliminary onboard user interface concepts to meet identified needs will be presented.

anomaly response↗

Innovative Drug Selection, Storage, and Shelf-Life Strategies for Exploration Spaceflight

Medications have been a part of space travel dating back to the Apollo missions. A safe and effective medication formulary is essential to maintaining crew health and performance during long-duration spaceflight outside of low Earth orbit (LEO). Distance from Earth creates four key operational changes that increase medical risks, including communication, resupply, crewmember health, and evacuation. The current spaceflight pharmaceutical formulary consists of medications indicated to treat a variety of anticipated medical events and healthcare needs during spaceflight, but depends on a robust consumables resupply chain, which may be strained for a Lunar, and possibly non-existent for a Mars mission. The specific medications selections for the formulary may change to optimally align with the mission, crew compliment, and spacecraft design. Medical support at long-duration exploration missions will differ from LEO missions due to mission duration, lack of consumables resupply, prolonged exposure to space radiation, and the absence of emergency medical return capability. Loss of medication resupply limits or removes the ability to replace medications that have been exhausted or degraded, potentially exacerbating the medical risk posture. To address these anticipated risks, long-duration missions must consider use of novel medical technologies, treatment modalities, and smart medical systems that offer greater crew autonomy, such as physiologically based pharmacokinetic modeling, drug repurposing, on demand drug synthesis, or wearable drug delivery / monitoring devices. Once an ideal formulary for exploration space is determined, it is essential to establish the chemical and physical stability of each medication compound, as well as its safety by identifying its degradation profiles and products. Although few studies have been conducted to provide evidence on the physicochemical stability of pharmaceuticals during space missions, the data suggests that the spaceflight environment may promote degradation in some pharmaceuticals. Formulary drug purity and efficacy should be verified by pharmaceutical stability assessments, and can be realized non-destructively, and accessed in remote environments. Non-destructive pharmaceutical analysis and statistical modelling techniques could optimize exploration spaceflight medical care by enabling early detection of suboptimal therapeutics. Likewise, novel packaging, storage strategies, and dosage form innovations are promising countermeasures to optimize pharmaceutical shelf life, purity, and quality of exploration spaceflight medications. As we prepare for more distant exploration missions, risk management planning for astronaut healthcare should include the assembly of a medication formulary that is comprehensive enough to prevent or treat anticipated medical events, remains safe and chemically stable, and retains sufficient potency to last for the duration of the mission. Following extensive review of the literature, we will present innovative formulary optimization strategies, pharmaceutical stability assessment techniques, and storage and packaging solutions that could enhance drug safety and efficacy for future exploration spaceflight missions.

Vernie R Daniels↗

Outgassing Characterization of Common Trash Items for Disposal By Nanoracks Airlock on the International Space Station

The arrival of the Nanoracks Airlock to the International Space Station (ISS) has provided the ISS program the capability to dispose of common trash items. The concept of operations involved the crew bagging up those items into a trash bag and then utilizing the robotic arm and the airlock to jettison the trash bag. Because of the unknown thermal vacuum stability of some of the items, a molecular contamination concern was raised by the ISS program as the trash is exposed to vacuum upon the evacuation of air from the airlock and the robotic arm moving the airlock to its jettison location. In order to characterize the representative outgassing rates for ISS trash, thermal vacuum testing was performed at White Sands Test Facility. Trash was sorted into a “lower” outgassing bag and a “mixed” bag. The “mixed” trash bag contained more items that were suspected to be not vacuum stable. Load cells were chosen as the primary means for measuring mass loss. A sharp decay in the outgassing rate was observed in the first 30 minutes followed by a slower decay. As expected, the “mixed” bag lost more mass. While Quartz Crystal Microbalances (QCMs) are often utilized to measure long term outgassing rates and the sticking coefficients of contaminants at different operating temperatures for vacuum stable materials, these measurements proved difficult due to the amount and the inclusion of materials with suspect thermal vacuum stability. Because of high rates of material outgassing, the facility was unable to maintain the CQCM temperature setpoint of 80 K QCMs.. The QCMs operating at the warmer temperatures also saturated on occasion due to high levels of condensed matter. Though testing was able to confirm high risk of outgassing contamination for the program, true sticking coefficients could not be determined, available measurements are provided herein.

Alvin Y Huang↗

Preparation of a dense, polycrystalline ceramic structure

Ceramic nanopowder was sealed inside a metal container under a vacuum. The sealed evacuated container was forced through a severe deformation channel at an elevated temperature below the melting point of the ceramic nanopowder. The result was a dense nanocrystalline ceramic structure inside the metal container.

Cooley, Jason↗

Flow chamber

A flow chamber having a vacuum chamber and a specimen chamber. The specimen chamber may have an opening through which a fluid may be introduced and an opening through which the fluid may exit. The vacuum chamber may have an opening through which contents of the vacuum chamber may be evacuated. A portion of the flow chamber may be flexible, and a vacuum may be used to hold the components of the flow chamber together.

47 OTHER INSTRUMENTATION↗

Linear electronic field time-of-flight ion mass spectrometers

Time-of-flight mass spectrometer comprising a first drift region and a second drift region enclosed within an evacuation chamber; a means of introducing an analyte of interest into the first drift region; a pulsed ionization source which produces molecular ions from said analyte of interest; a first foil positioned between the first drift region and the second drift region, which dissociates said molecular ions into constituent atomic ions and emits secondary electrons; an electrode which produces secondary electrons upon contact with a constituent atomic ion in second drift region; a stop detector comprising a first ion detection region and a second ion detection region; and a timing means connected to the pulsed ionization source, to the first ion detection region, and to the second ion detection region.

Funsten, Herbert O↗

Calibration and performance of a secondary emission chamber as a beam intensity monitor

We report on a study of the behavior of a secondary emission chamber (SEC). We show the dependence of the SEC signal on the charge and velocity of the primary beam for beams of protons, and heavy ions including Helium, Neon, Chlorine and Iron. We fill the SEC with a selection of different gases including Hydrogen, Helium, Nitrogen, Argon, and air, studying the SEC response when it is acting as an ion chamber. We also investigate the behavior of the SEC at intermediate pressures between 10{sup -8} torr and atmospheric pressure. The SEC uses thin conducting foils as the source and collector of electrons in a vacuum chamber. When charged particles traverse the vacuum chamber, they pass through a series of thin conducting foils, alternating anode and cathode. Ionization produced in the cathode foils travels across the intervening gap due to an applied high voltage and is collected on the anode foils. Electron production is very inefficient because most of the ionization in the foils remains trapped within the foil due to the short range of most delta-rays and the work function of the foil. It is this inefficiency that allows the SEC to operate at high dose rates and short pulse duration where the standard ion chambers cannot function reliably. The SEC was placed in the NSRL ion beam to receive a variety of heavy ion beams under different beam conditions. We used these ion beams to study the response of the SEC to different species of heavy ion, comparing with proton beams. We studied the response to beam of different energies, and as a function of different counting rate. We compared the behaviour of the SEC when operating under positive and negative high voltage. The SEC can operate as an ion chamber if it is filled with gas. We measured the response of the SEC when filled with a variety of gases, from Hydrogen to Helium, Nitrogen, Argon and air. The performance of the SEC as an ion chamber is compared with the standard NSRL ion chamber, QC3. By evacuating the SEC and filling it with Nitrogen through an adjustable leak valve, we were able to measure the response of the SEC to beam as a function of gas pressure. Many interesting features of the SEC were revealed in these tests.

08 HYDROGEN↗

Oak Ridge 25URC Tandem Accelerator 2007 SNEAP Lab Report

During FY 2008, the 25URC operated for slightly over 3,000 research hours. The radioactive species 80Ge and 17,18F accounted for 763 of these hours. This included an experiment using 17F which was only possible due to an improvement of a factor of 50 in beam intensity over our previous facility record. Twenty stable beam species were provided this year. Operation for the experimental program was at terminal potentials from 2.02 to 23.8 MV. Approximately 200 hours of conditioning were done to return the machine to operation after tank openings. There were six tank openings during the year: three scheduled for general maintenance and three unscheduled. Two of the unscheduled openings were required to correct shorting rod issues and the other was to reestablish communication with one of the major dead sections. On July 28, an event happened that caused all accelerators at the Holifield Radioactive Ion Beam Facility (HRIBF) to suspend operation. At approximately 8 AM on that Monday, during operations with approximately 12 {micro}A of 50-MeV protons on a uranium carbide target, delivering neutron-rich 81Zn beam to the new Low-energy Radioactive Ion Beam Spectroscopy Station (LeRIBSS), a radiological control technician (RCT) reported higher than normal radiation levels just outside the shield door to the IRIS1 vault (the room in which RIBs are produced at HRIBF). The measured dose rate equivalent was 4 mrem/hr. The presence of radiological contamination on the floor just outside the shield door was subsequently noted, as was the possible presence of airborne radioactivity. These observations were reported to facility management. Accelerators were put in standby immediately and the building evacuated. The event was declared a laboratory operational emergency. Parts of the building were cleared for reentry to collect belongings on Monday afternoon. The entire building was cleared for reoccupation on Tuesday morning after a detailed radiological survey found no contamination outside the shielded vaults. No decontamination was required. No individual received any detectable radiological dose as a result of this event. The 25URC tandem accelerator was given permission to resume operation with stable beams in early September, but radioactive ion production is still not allowed. Subsequent analysis indicated a release that consisted entirely of noble gasses (Xe and Kr isotopes). We believe we have identified two unrelated failures, one associated with the HVAC system and the other with the roughing system exhaust which accounts for both the escape of noble gasses into the IRIS1 vault and their migration outside the vault. An investigation team report is expected by October 24. At that time, corrective actions will be determined and the path to future radioactive ion beam production will be known. The break from operations allowed a few upgrades to be implemented. The most notable was the installation and commissioning of a SNICS ion source purchased from National Electrostatics Corporation (NEC). The SNICS replaced the old Alton/Aarhus source that we have used for many years. An ANU style gas cathode holder was purchased also but has not yet been implemented. The first beams have been produced by the source and the biggest problem encountered was reducing the beam for very low current experiments. A new power supply for the injection magnet was installed during this period also. Radioactive ion beam (RIB) development at the High Power Target Laboratory (HPTL) has been delayed this year while installing the platforms, conduits and equipment for the second Injector for Radioactive Ion Species (IRIS2) which is co-located with the HPTL facility. The majority of development activities have been performed at the two off-line ion source test facilities (ISTF1 and ISTF2) and the On-Line Test Facility (OLTF). Both test facilities have been developing systems which will eventually be used with IRIS2. Two new tunable Ti:Sapphire lasers have been ordered for continuing development of an ion source based on laser ionization using all solid-state lasers. When these are delivered, we will have a complete laser system. The other ion source test facility is continuing development of a negative-ion cooler for beam purification using photodetachment. This process has been demonstrated to work well in three systems so far (removing Co from Ni, removing S from Cl, and removing O from F). The original ion cooler has been modified to allow for use on the IRIS2 platform. Testing of this modified device is starting now. The OLTF has been used to test new types of uranium carbide targets for the electron beam plasma source (which are used for neutron-rich RIB campaigns) and to test a novel ion source which may result in purified beams of radioactive strontium isotopes. This ion source uses a quartz tube in the transfer line between the production target and the ion source to selectively slow down some elements such as rubidium and cesium.

43 PARTICLE ACCELERATORS↗

A Fruit of Yucca Mountain: The Remote Waste Package Closure System

Was the death of the Yucca Mountain repository the fate of a technical lemon or a political lemon? Without caution, this debate could lure us away from capitalizing on the fruits of the project. In March 2009, Idaho National Laboratory (INL) successfully demonstrated the Waste Package Closure System, a full-scale prototype system for closing waste packages that were to be entombed in the now abandoned Yucca Mountain repository. This article describes the system, which INL designed and built, to weld the closure lids on the waste packages, nondestructively examine the welds using four different techniques, repair the welds if necessary, mitigate crack initiating stresses in the surfaces of the welds, evacuate and backfill the packages with an inert gas, and perform all of these tasks remotely. As a nation, we now have a proven method for securely sealing nuclear waste packages for long term storage—regardless of whether or not the future destination for these packages will be an underground repository. Additionally, many of the system’s features and concepts may benefit other remote nuclear applications.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Steady State Heat Deposits Modeling in the Nb3Sn Quadrupole Magnets for the Upgrade of the LHC Inner Triplet

In hadron colliders such as the LHC, the energy deposited in the superconductors by the particles lost from the beams or coming from the collision debris may provoke quenches detrimental to the accelerator operation. In previous papers, a Network Model has been used to study the thermodynamic behavior of magnet coils and to calculate the quench levels in the LHC magnets for expected beam loss profiles. This model was subsequently used for thermal analysis and design optimization of Nb{sub 3}Sn quadrupole magnets, which LARP (US LHC Accelerator Research Program) is developing for possible use in the LHC luminosity upgrade. For these new magnets, the heat transport efficiency from the coil to the helium bath needs to be determined and optimized. In this paper the study of helium cooling channels and the heat evacuation scheme are presented and discussed.

43 PARTICLE ACCELERATORS↗

Search for 14.4-KeV Solar Axions Emitted in the M1-Transition of Fe-57 Nuclei with CAST

We have searched for 14.4 keV solar axions or more general axion-like particles (ALPs), that may be emitted in the M1 nuclear transition of 57Fe, by using the axion-to-photon conversion in the CERN Axion Solar Telescope (CAST) with evacuated magnet bores (Phase I). From the absence of excess of the monoenergetic X-rays when the magnet was pointing to the Sun, we set model-independent constraints on the coupling constants of pseudoscalar particles that couple to two photons and to a nucleon g{sub ay}|-1.19g{sub aN}{sup 0}+g{sub aN}{sup 3}| < 1.36 x 10{sup -16} GeV{sup -1} for ma < 0.03 eV at the 95% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lifetime studies of 130nm nMOS transistors intended for long-duration, cryogenic high-energy physics experiments.

Future neutrino physics experiments intend to use unprecedented volumes of liquid argon to fill a time projection chamber in an underground facility. To increase performance, integrated readout electronics should work inside the cryostat. Due to the scale and cost associated with evacuating and filling the cryostat, the electronics will be unserviceable for the duration of the experiment. Therefore, the lifetimes of these circuits must be well in excess of 20 years. The principle mechanism for lifetime degradation of MOSFET devices and circuits operating at cryogenic temperatures is via hot carrier degradation. Choosing a process technology that is, as much as possible, immune to such degradation and developing design techniques to avoid exposure to such damage are the goals. This requires careful investigation and a basic understanding of the mechanisms that underlie hot carrier degradation and the secondary effects they cause in circuits. In this work, commercially available 130nm nMOS transistors operating at cryogenic temperatures are investigated. The results show that the difference in lifetime for room temperature operation and cryogenic operation for this process are not great and the lifetimes at both 300K and at 77K can be projected to more than 20 years at the nominal voltage (1.5V) for this technology.

43 PARTICLE ACCELERATORS↗