SEARCH · Search NASA
Results for “Energy Storage System”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Intercalation of Ca into a Highly Defective Manganese Oxide at Room Temperature
The utilization of oxide frameworks as intercalation cathodes for non-aqueous Ca-ion batteries potentially unlocks a new energy storage system that delivers high energy density. However, the slow kinetics of Ca 2+ in oxide electrodes strongly handicaps their activity and reversibility at room temperature. Here, nanocrystals of layered MnO x containing a high concentration of atomic defects and lattice water are shown to have remarkable electrochemical activity towards Ca 2+ , amounting to a capacity of ~130 mAh/g at room temperature. Multimodal characterization revealed the notable degree of intercalation by probing the structural, compositional and redox changes undertaken by the defective MnO x nanocrystals. The results suggest that the existence of atomic defects and lattice water played a role in improving Ca 2+ diffusivity in the oxide. These outcomes reaffirm the prospects for functional Ca-ion batteries using oxide cathodes under moderate conditions.
AnisONet: A deep neural operator-based anisotropic permeability upscaler from pore to Darcy scale
Directional permeability variations, which govern directional fluid flow in porous media with anisotropy, are important to accurately predict flow behavior, reactive transport, and fluid–solid interactions for various processes such as enhanced geothermal systems, energy storage devices, and biological systems. However, the intricate architecture of porous media makes it difficult to predict directional permeabilities. In this work, we present a novel machine learning (ML) framework, AnisONet, built upon an integration of a convolutional neural network, Swin transformer, and the deep operator network architecture, designed to predict anisotropic permeability and upscale predictions to larger spatial domains. First, AnisONet was evaluated with three classes of two-dimensional (2D) porous media, including synthetic circular and elliptical grains and natural sandstone grains from micro-computed tomography images. A lattice Boltzmann model (LBM) was used to calculate directional permeabilities at every 10° angle, producing 19 data points per image of porous media. AnisONet is then trained to predict permeability as a function of rotation angle. AnisONet showed strong predictive capability of directional permeability. Second, we tested our model for five upscaling cases with a large image size in the finite-element method (FEM) for 2D Darcy flow with various permeability tensor construction methods. Overall, upscaled permeability tensors in FEM simulations produce a reasonably good match with LBM results, highlighting the importance of selecting appropriate tensor formation strategies for accurate permeability upscaling. AnisONet, as a directional permeability estimator, could be further developed for more complex geometries, with the potential to develop a foundational ML model for various applications in porous media.
Impedance Characterization of Utility-Scale Renewable Energy and Storage Systems
This paper presents the impedance characterization of utility-scale wind turbines and PV/storage inverters using a multimegawatt grid simulator-based grid integration testbed. The paper describes the testbed components including a 7 MVA grid simulator, 5 MW dynamometer, medium-voltage measurement system, and a real-time control system used for automated impedance characterization of wind turbines and inverters. Different aspects of impedance measurement are discussed, including the selection of the magnitude and type of perturbation, measurement of frequency cross-coupling between sequence impedance responses, and the alignment of the reference frame for sequence impedance measurement. The paper also demonstrates high-fidelity validation of EMT simulation models from turbine manufacturers and characterization of grid-forming inverters using impedance measurements.
Recommended Practice for Energy Storage Management Systems in Grid Applications.
Abstract not provided.
Community Microgrid Planning Considering Building Thermal Dynamics
In this paper, the building thermal dynamic characteristics are introduced in the community microgrid (MG) planning model. The proposed planning model is formulated as a mixed integer linear programming (MILP) which seeks to determine the optimal deployment strategy for various distributed energy resources (DER). The objective is to minimize the annualized cost of community MG, including investment cost in DER, operation cost for dispatchable fuel-generators (DFG), energy storage system (ESS) degradation cost, energy purchasing and peak demand charge at PCC, customer discomfort cost due to the room temperature deviation and load curtailment cost. Given the slow thermal dynamic characteristics of buildings, the heating, ventilation and air-conditioning (HVAC) system in the proposed model is treated as a demand side management (DSM) component, whose dispatch commands are provided by the central MG controller. Numerical results based on a community MG comprising of 20 residential buildings demonstrate the effectiveness of the proposed planning model and the benefits of introducing the building thermal dynamic model.
Performance and Durability of Hybrid Fuel Cell Systems for Class-8 Long Haul Trucks
Hybrid fuel cell-battery configurations are investigated that overcome thermal management issues in fuel cell powertrains for heavy-duty Class 8 trucks. The battery is sized so that it has sufficient capacity to provide supplemental power and energy on a hill climb transient at end-of-life. A dynamic load sharing strategy is developed to distribute the power demand between the fuel cell system (FCS) and the energy storage system in a manner that optimizes their lifetimes. The FCS end-of-life is identified as the terminal point beyond which the stack cannot generate the rated power with target power density at 0.7 V and 40 °C ambient temperature. Reaching the target lifetime with a-Pt/C cathode catalyst in one hybrid configuration requires voltage clipping to 813 mV, idle power limited to 50 kW, catalyst overloading to 0.45 mg cm -2 total Pt in anode and cathode, and 44% active membrane area oversizing. The stack and FCS drive cycle efficiencies decrease by 4.2% and 5.4%, respectively, during the electrode lifetime. Further, the FCS performance, durability and cost are compared with the targets of 68% peak efficiency, 0.30 mg cm -2 total Pt loading, 2.5 kW/g PGM Pt group metal (PGM) loading, 750 mW cm -2 power density, 25,000-h lifetime and $80/kW cost.
IEEE Standard Development for Energy Storage Management Systems.
Abstract not provided.
Battery Management System Standard: IEEE P2686 Recommended Practice for Battery Management Systems in Energy Storage Applications .
Abstract not provided.
Analysis of Different Permutation of a Hybrid Concentrated Solar Power (CSP) & Pumped Thermal Energy Storage (PTES) System.
Abstract not provided.
Recommended Practice for Energy Storage Management Systems in Grid Applications.
Abstract not provided.
Analysis of a Hybrid Concentrated Solar Power (CSP) & Pumped Thermal Energy Storage (PTES) System and Safety Approaches
Explore the source record for details and available documents.
Interpreting T-History Data on Supercooling and Phase Change Enthalpy of a Salt-Hydrogel Complex for Building Thermal Management
Phase change materials (PCMs) are promising materials for storing and discharging latent heat in buildings to regulate the thermal environment. Measurement of salt hydrate PCM thermal performance is often challenging because of supercooling and phase segregation. Though differential scanning calorimetry (DSC) has been widely used to measure thermal properties of various phase change materials, DSC uses milligrams of sample and is unrealistic for predicting large-scale materials performance. The T-history method [1], in contrast, handles higher volumes but the analysis typically requires a lumped capacitance assumption. Here, we report and analyze T-History data on a novel salt-hydrogel complex with high viscosity, that renders low Biot number sample preparation extremely challenging. We re-examine the standard T-history method and compared against DSC data in this complex material. We report details of an experimental setup, built with necessary additions to a controlled environmental chamber. We carefully examine the validity of the lumped capacitance assumption and suggest a modified analysis using a computational approach for reliable data. Experimental parameters such as ramp rate and temperature range of the environmental chamber are considered via computational modeling to understand the effect of ramp rate on supercooling [2]. Finally, we report thermal cycling experiments on the salt-hydrogel complex. Our modified approach to measuring supercooling and enthalpy of fusion at large scales is important in better understanding the performance of phase-change materials at scale for building thermal storage. References: [1] Marin, Jose M, Belen Zalba, Luisa F Cabeza, and Harald Mehling. “Determination of Enthalpy Temperature Curves of Phase Change Materials with the Temperature-History Method: Improvement to Temperature Dependent Properties.” Measurement Science and Technology 14, no. 2 (February 1, 2003): 184–89. https://doi.org/10.1088/0957-0233/14/2/305. [2] Safari, A., R. Saidur, F.A. Sulaiman, Yan Xu, and Joe Dong. “A Review on Supercooling of Phase Change Materials in Thermal Energy Storage Systems.” Renewable and Sustainable Energy Reviews 70 (April 2017): 905–19. https://doi.org/10.1016/j.rser.2016.11.272
IEEE P2688 Work Group (WG): Draft Recommended Practice for Energy Storage Management Systems (ESMS) in Grid Applications
Poster for DOE ES Peer Review
Multiplexed battery-bypass control system
Cell-bypass control system senses low capacity cells before they overcharge or discharge. Relay automatically removes defective cell (when it is detected) from battery circuit. System shows promise for improving batteries in computer standby power systems, electric vehicles, and energy storage systems.
Electromagnetic studies of redox systems for energy storage
Both chromium and iron couples were studied on various electrode surfaces in acidic perchlorate solution by using rotating ring-disk techniques. It was found that chloride which forms inner sphere coordination complexes with the redox species enhances the electrode kinetics dramatically. The effects of lead underpotential deposition and surface alloy formation on the kinetics of the chromium couple on gold were studied using both linear sweep voltammetry and potential step techniques. The lad underpotential deposition was found to slow down the kinetics of the reduction of the Cr species on gold surfaces although increase the hydrogen overvoltage. The effect on the chromium kinetics can be explained in terms of principally a double layer effect. The underpotential deposition lead species with its positive charge results in a decrease in the concentration of the Cr species at the electrode surface. Similar phenomena were also observed with bismuth underpotential deposition on gold for the iron couple.