Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Development of an autonomous solvent extraction system to isolate astatine-211 from dissolved cyclotron bombarded bismuth targets

Abstract Cyclotron-produced astatine-211 ( 211 At) shows tremendous promise in targeted alpha therapy (TAT) applications due to its attractive half-life and its 100% α-emission from nearly simultaneous branched alpha decay. Astatine-211 is produced by alpha beam bombardment of naturally monoisotopic bismuth metal ( 209 Bi) via the ( α, 2n ) reaction. In order to isolate the small mass of 211 At (specific activity = 76 GBq·µg −1 ) from several grams of acid-dissolved Bi metal, a manual milliliter-scale solvent extraction process using diisopropyl ether (DIPE) is routinely performed at the University of Washington. As this process is complex and time consuming, we have developed a fluidic workstation that can perform the method autonomously. The workstation employs two pumps to concurrently deliver the aqueous and organic phases to a mixing tee and in-line phase mixer. The mixed phases are routed to a phase settling reservoir, where they gravity settle. Finally, each respective phase is withdrawn into its respective pump. However, development of a phase boundary sensor, placed in tandem with the phase settling reservoir, was necessary to communicate to the system when withdrawal of the denser aqueous phase was complete (i.e., the intersection of the two phases was located). The development and optimization of the autonomous solvent extraction system is described, and the 211 At yields from several ~1.1 GBq-level 211 At processing runs are reported.

211At↗

Solvent selection for biphasic extraction of 5-hydroxymethylfurfural via multiscale modeling and experiments

We introduce a comprehensive conceptual framework for selecting solvents for reactive extraction in biphasic organic-water systems and demonstrate it for the separation of HMF (5-hydroxylmethylfurfural), a platform chemical produced in the acid-catalyzed dehydration of hexoses. We first perform in silico screening of ~2500 solvents, from the ADFCRS-2018 database using the ADF COSMO-RS implementation, and classification, based on the solvent partition coefficient. We then determine experimentally the partition coefficients for HMF, fructose, and products of HMF rehydration (levulinic acid (LA), and formic acid (FA)), the mutual water-organic solvent solubilities, and the separation factors in >50 select solvents spanning multiple homologous series at room temperature and a typical reaction temperature with in situ sampling. We find that COSMO-RS is excellent for screening purposes (typical error in most cases within a factor of ~2). Increased temperatures lead to significant reduction in partitioning, and room temperature measurements are clearly inadequate for solvent selection. Upon down selecting classes of solvents based on separation performance, we perform experimental thermal stability and reaction compatibility studies of a small set of solvents at relevant reactive-extraction temperatures. We discover that many substituted phenols exhibit an order-of-magnitude increase in partitioning compared to conventional solvents due chiefly to hydrogen bond interactions and show the necessary stability but retain a significant fraction of water and LA, factors that need to be considered in technoeconomic analysis. In contrast, anilines, aldehydes, and acids are good to excellent regarding separation but incompatible with this specific reaction medium. Furthermore, this multifaceted framework can be extended to other biomass-derived products and processes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Light-extraction enhancement in GaN-based light-emitting diodes using grade-refractive-index amorphous titanium oxide films with porous structures

Amorphous titanium oxide (a-TiO{sub x}:OH) films prepared by plasma-enhanced chemical-vapor deposition at 200 and 25 deg. C are in turn deposited onto the GaN-based light-emitting diode (LED) to enhance the associated light extraction efficiency. The refractive index, porosity, and photocatalytic effect of the deposited films are correlated strongly with the deposition temperatures. The efficiency is enhanced by a factor of {approx}1.31 over that of the uncoated LEDs and exhibited an excellent photocatalytic property after an external UV light irradiation. The increase in the light extraction is related to the reduction in the Fresnel transmission loss and the enhancement of the light scattering into the escape cone by using the graded-refractive-index a-TiO{sub x}:OH film with porous structures.

36 MATERIALS SCIENCE↗

Converting an AEG Cyclotron to H{sup -} Acceleration and Extraction

Clinical Trials are under way to evaluate agents labeled with the nuclide {sup 225}Ac and its decay product {sup 213}Bi, in targeted alpha-immuno-therapy. {sup 225}Ac can be produced on a medium-energy cyclotron via the nuclear reaction {sup 226}Ra(p,n){sup 225}Ac. To demonstrate proof-of-principle, a vintage AEG cyclotron, Model E33, with an internal target, had been employed in a pilot production program at the Technical University of Munich (TUM). To enhance production capability and further support the clinical studies, the TUM facility has recently been refurbished and upgraded, adding a new external beam-line, automated target irradiation and transport systems, new laboratories, hot cells, etc.. An improved high-power rotating target has been built and installed. The AEG cyclotron itself has also been modified and upgraded to accelerate and extract H{sup -} ions. We have designed, built, and tested a new axial Penning-type ion source which is optimized for the production of H{sup -} ions. The ion source has continued to evolve through experiment and experience. Steady improvements in materials and mechanics have led to enhanced source stability, life-time, and H{sup -} production. We have also designed and built a precision H{sup -} charge-exchange beam-extraction system which is equipped with a vacuum lock. To fit within the tight mechanical constraint imposed by the narrow magnet gap, the system incorporates a novel chain-drive foil holder and foil-changer mechanism. The reconfigured cyclotron system has now been in operation for more than 1 year. Three long-duration target irradiations have been conducted. The most recent bombardment ran 160 continuous hours at a beam on target of {approx}80 microamperes for a total yield of {approx}70 milli-curies of {sup 225}Ac.

43 PARTICLE ACCELERATORS↗

IONEX: A meshfree ion extraction code based on ''particle in cloud of points'' concept

Ion Extraction (IONEX) is an ion extraction modeling code, developed at FAR-TECH, Inc., based on the meshless particle-in-cloud-of-points concept. IONEX self-consistently solves motion equations for ions and Poisson's equation for the electrostatic field, assuming a Boltzmann distribution for the electrons. IONEX is capable of handling multiple species and is graphical user interface-driven. The two-dimensional version is benchmarked with IGUN. The basic algorithm and sample runs are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Extraction simulations and emittance measurements of a Holifield Radioactive Ion Beam Facility electron beam plasma source for radioactive ion beams

The Holifield Radioactive Ion Beam Facility (HRIBF) at Oak Ridge National Laboratory has a variety of ion sources used to produce radioactive ion beams (RIBs). Of these, the workhorse is an electron beam plasma (EBP) ion source. The recent addition of a second RIB injector, the Injector for Radioactive Ion Species 2 (IRIS2), for the HRIBF tandem accelerator prompted new studies of the optics of the beam extraction from the EBP source. The source was modeled using SIMION V8.0, and results will be presented, including comparison of the emittances as predicted by simulation and as measured at the HRIBF offline ion source test facilities. Also presented will be the impact on phase space shape resulting from extraction optics modifications implemented at IRIS2.

43 PARTICLE ACCELERATORS↗

Gallium ion extraction from a plasma sputter-type ion source

A broad mixed ion beam containing positive ions of gallium (Ga) was produced with a plasma sputter-type ion source. Liquid Ga was suspended on a tungsten reservoir to be sputtered and postionized in argon (Ar) plasma excited by a radio frequency (rf) power at 13.56 MHz. Optical emission spectra from the plasma near the Ga sputtering target had indicated that the release of Ga into plasma increased with increasing negative bias to the sputtering target. The ratio of Ga{sup +} current to Ar{sup +} current was measured to be about 1% with a quadrupole mass analyzer at 100 V extraction voltage for incident rf power as low as 30 W. Ions in the plasma were extracted through a pair of multiaperture electrodes. The homogeneity of Ga flux was examined by making a Ga deposition pattern on a glass substrate located behind the extractor electrodes.

43 PARTICLE ACCELERATORS↗

Extraction and Acceleration of Ions from an Ion-Ion Plasma

Extraction and acceleration of positive and negative ions from a strong electronegative plasma and from an ion-ion plasma is investigated in the PEGASES thruster, working with SF{sub 6}. The plasma is generated in a cylindrical quartz tube terminated by metallic endplates. The electrons are confined by a static magnetic field along the axis of the cylinder. The electron mobility along the field is high and the electrons are determining the sheaths in front of the endplates. The core plasma potential can therefore be controlled by the bias applied to the endplates. An ion-ion plasma forms at the periphery as a result of electron confinement and ions can freely diffuse along the perpendicular direction or extraction axis. Langmuir probe and RFEA measurements are carried out along this axis. The measured ion energy distributions shows a single peak centered around a potential consistent with the plasma potential and the peak position could be controlled with a positive voltage applied to the endplates. When the endplates are biased negatively, the plasma potential saturates and remained close to 15 V. A beam of negatively charged particles can be observed under certain conditions when the endplates were biased negatively.

43 PARTICLE ACCELERATORS↗

Test bench to commission a third ion source beam line and a newly designed extraction system

The HIT (Heidelberg Ion Beam Therapy Center) is the first hospital-based treatment facility in Europe where patients can be irradiated with protons and carbon ions. Since the commissioning starting in 2006 two 14.5 GHz electron cyclotron resonance ion sources are routinely used to produce a variety of ion beams from protons up to oxygen. In the future a helium beam for regular patient treatment is requested, therefore a third ion source (Supernanogan source from PANTECHNIK S.A.) will be integrated. This third ECR source with a newly designed extraction system and a spectrometer line is installed at a test bench at HIT to commission and validate this section. Measurements with different extraction system setups will be presented to show the improvement of beam quality for helium, proton, and carbon beams. An outlook to the possible integration scheme of the new ion source into the production facility will be discussed.

43 PARTICLE ACCELERATORS↗

Progress towards the development of a realistic electron cyclotron resonance ion source extraction model

In this paper, an ongoing effort to provide a simulation and design tool for electron cyclotron resonance ion source extraction and low energy beam transport is described and benchmarked against experimental results. Utilizing the particle-in-cell code WARP, a set of scripts has been developed: A semiempirical method of generating initial conditions, a 2D-3D hybrid method of plasma extraction and a simple beam transport deck. Measured emittances and beam profiles of uranium and helium beams are shown and the influence of the sextupole part of the plasma confinement field is investigated. The results are compared to simulations carried out using the methods described above. The results show that the simulation model (with some additional refinements) represents highly charged, well-confined ions well, but that the model is less applicable for less confined, singly charged ions.

43 PARTICLE ACCELERATORS↗

The influence of the extraction voltage on the energetic electron population of an electron cyclotron resonance ion source plasma

An influence of the extraction voltage on the high energy slope of bremsstrahlung radiation spectra has been reported in ECRIS experiments, which is not well understood so far. In order to provide more detailed data on this effect, we have measured bremsstrahlung radiation spectra accompanying especially the evolution of highly charge ions (i.e., by monitoring the Ar{sup 14+} charge state) as the extraction voltage is changed from 0 to 20 kV, in dedicated experiments at the Frankfurt 14 GHz-ECRIS.

43 PARTICLE ACCELERATORS↗

Velocity-map imaging at low extraction fields

We present a velocity-map imaging (VMI) setup for photoelectron imaging that utilizes low electric extraction fields. This avoids any complications that could arise from electrostatic interactions between the extraction field and the molecular properties that are probed and has a minimal effect on the trajectory of ions in ion beam experiments. By using an attractive potential supplied to the detector, and keeping the electrodes at ground (zero) potential, we show that fringe fields between the VMI arrangement and the vacuum chamber can be eliminated, which is important in experiments on ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of negative ions from pulsed electronegative capacitively coupled plasmas

Charge buildup during plasma etching of dielectric features can lead to undesirable effects, such as notching, bowing, and twisting. Pulsed plasmas have been suggested as a method to achieve charge-free plasma etching. In particular, electronegative plasmas are attractive as the collapse of the plasma potential during the after-glow period of pulsed capacitively coupled plasmas (CCPs) can allow for extraction of negative ions into the feature. The extraction of negative ions in the after-glow of pulsed CCPs sustained in CF{sub 4} containing gas mixtures is computationally investigated. In this paper, the consequences of pulse frequency and gas chemistry on negative ion flux to the wafer are discussed. A low negative ion flux to the wafer was observed only in the late after-glow period of low pulse frequencies. The negative ion flux was found to significantly increase with the addition of highly electronegative gases (such as thermally attaching Cl{sub 2}) even at a high pulse frequency of 10 kHz. As the production of negative ions during the after-glow diminishes, alternative strategies to enhance the flux were also pursued. The flux of negative ions was found to increase by the addition of a pulsed dc voltage on the top electrode that is 180 Degree-Sign out-of-phase with the rf pulse.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ion beams extraction and measurements of plasma parameters on a multi-frequencies microwaves large bore ECRIS with permanent magnets

We have developed an all-permanent magnet large bore electron cyclotron resonance ion source (ECRIS) for broad ion beam processing. The cylindrically comb-shaped magnetic field configuration is adopted for efficient plasma production and good magnetic confinement. To compensate for disadvantages of fixed magnetic configuration, a traveling wave tube amplifier (TWTA) is used. In the comb-shaped ECRIS, it is difficult to achieve controlling ion beam profiles in the whole inside the chamber by using even single frequency-controllable TWTA (11-13GHz), because of large bore size with all-magnets. We have tried controlling profiles of plasma parameters and then those of extracted ion beams by launching two largely different frequencies simultaneously, i.e., multi-frequencies microwaves. Here we report ion beam profiles and corresponding plasma parameters under various experimental conditions, dependence of ion beams against extraction voltages, and influence of different electrode positions on the electron density profile.

43 PARTICLE ACCELERATORS↗

A 2D Particle in Cell model for ion extraction and focusing in electrostatic accelerators

Negative ions are fundamental to produce intense and high energy neutral beams used to heat the plasma in fusion devices. The processes regulating the ion extraction involve the formation of a sheath on a scale comparable to the Debye length of the plasma. On the other hand, the ion acceleration as a beam is obtained on distances greater than λ{sub D}. The paper presents a model for both the phases of ion extraction and acceleration of the ions and its implementation in a numerical code. The space charge of particles is deposited following usual Particle in Cell codes technique, while the field is solved with finite element methods. Some hypotheses on the beam plasma transition are described, allowing to model both regions at the same time. The code was tested with the geometry of the NIO1 negative ions source, and the results are compared with existing ray tracing codes and discussed.

43 PARTICLE ACCELERATORS↗

100 s extraction of negative ion beams by using actively temperature-controlled plasma grid

Long pulse beam extraction with a current density of 120 A/m{sup 2} for 100 s has been achieved with a newly developed plasma grid (PG) for the JT-60SA negative ion source which is designed to produce high power and long pulse beams with a negative ion current of 130 A/m{sup 2} (22 A) and a pulse length of 100 s. The PG temperature is regulated by fluorinated fluids in order to keep the high PG temperature for the cesium-seeded negative ion production. The time constant for temperature controllability of the PG was measured to be below 10 s, which was mainly determined by the heat transfer coefficient of the fluorinated fluid. The measured decay time of the negative ion current extracted from the actively temperature-controlled PG was 430 s which was sufficient for the JT-60SA requirement, and much longer than that by inertial-cooling PG of 60 s. Obtained results of the long pulse capability are utilized to design the full size PG for the JT-60SA negative ion source.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Plasma characteristics of single- and dual-electrode ion source systems utilized in low-energy ion extraction

Discharge characteristics in the upstream as well as in the downstream regions of a 50-eV positive ion beam were measured along the beam axis. Single- and dual-electrode configurations made of 0.1-mm diameter tungsten wires were tested. By varying the upstream discharge parameters, the shape of the sheath edge around the extractors, which can either be “planar” or “cylindrical,” can be controlled. The sheath eventually affected the simultaneous extraction of ions and neutralizing electrons. The dual-electrode configuration at the lower discharge current, revealed a homogeneous discharge downstream. At this condition, the edge of the sheath can be inferred to be “planar” which allowed the uniform extraction and propagation of low-energy ions at longer distances. The dual-electrode configuration was capable of transmitting low-energy ions up to 70 mm downstream.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluation of internal potential distribution and carrier extraction properties of organic solar cells through Kelvin probe and time-of-flight measurements

The carrier extraction property of a prototypical small molecule organic solar cell (OSC) composed of copper phthalocyanine (CuPc), C⁶⁰, and bathocuproine (BCP) was studied on the basis of the internal potential distribution and carrier dynamics in the device. The internal potential distribution in the OSC structure at the interfaces and in the bulk region was determined by the Kelvin probe method. Significant potential gradients were found in the CuPc film on indium tin oxide and in the C⁶⁰ film on CuPc, consistent with charge transfer through the contacts. Moreover, surface potential of the BCP layer grew linearly with increasing film thickness with a slope of ca. 35 mV/nm (giant surface potential: GSP), which indicated spontaneous orientation polarization in the film. The potential gradient and GSP significantly changed the built-in potential of the device. Current–voltage and modified time-of-flight measurements revealed that the BCP layer worked as an electron injection and extraction layer despite the wide energy gap. These results were discussed based on the contributions of GSP and the gap states in the BCP layer.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗