Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Comparison of Space Launch System Aerodynamic Surface Pressure Measurements from Experimental Testing and CFD

A comparison of surface pressure coefficient measurements obtained using pressure-sensitive paint (PSP) measurements with predictions from the computational fluid dynamics (CFD) code FUN3D is presented for the NASA SLS Block 1B crew vehicle. Overall, the flow features over the SLS configuration were captured by both the PSP data and CFD data at freestream Mach numbers (M(sub ∞)) of 0.8 and 1.3. Overall, the flow features over the SLS are captured by the PSP data but the intensities of large pressure gradients are less intense than what was predicted by the CFD data. Several examples of this observation are given including the flow interaction at the booster nose cone edge, core body, and forward booster attachment hardware at M(sub ∞) = 0.8.

FUN3D↗

Two-Phase Flow in Filters and Orifices: In preparation for Measurements on ISS Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS)

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors offers numerous benefits. It enables the optimization of chemical reactions rates and products, crucial for pharmaceuticals and energy production industries. Additionally, this understanding aids in designing more efficient and compact reactors, reducing space and resource requirements. Insights gained from studying such flows in microgravity contribute to advancements of space technologies and the enhancement of our capabilities for undertaking future long duration safe, and sustainable space exploration missions. The Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) is a flight experiment planned for operation on the Microgravity Science Glove box (MSG) facility of the International Space Station (ISS). The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments. The experiment consists of testing two-phase flow hydrodynamics in three different filters, four (4) orifices and one check valve test articles. The experiment utilizes the hardware of the previously flown PBRE and PBRE-2 with packed beds of different packings materials and sizes. The fluid system of the PBRE-WRS consists of a nitrogen gas delivery and water delivery subsystems. The gas delivery subsystem can accommodate two ranges of gas flow rates, just as for the water delivery system. The nitrogen gas loop is open whereas the water loop is closed. Gas is separated from the water using a gas-liquid phase separator which is located in the water delivery module. Preliminary results from ground testing show the pressure drop increasing at different rates with the liquid and gas flow rates in the Brine filter. In this work, a detailed system description is presented along with a summary of results from ground performance testing of different test sections in an end-to-end preflight testing campaign.

Packed Bed Reactor Experiment↗

Herpesviruses in Saliva and Their Clinical Significance

Saliva has been used as a source of biological markers for a wide spectrum of normal and disease states for a long time. It is a non-invasive, easily accessible, and self-collected body fluid that contains a variety of measurable biological substances. While mostly water, saliva also contains ions, carbohydrates, proteins and peptides, exfoliated cells, nucleic acids, and microorganisms. Saliva can reflect tissue levels of some natural substances and a large variety of molecules introduced for therapeutic use, emotional status; hormonal status, immunological status, neurological effects, and nutritional and metabolic status. It can also be used to monitor a variety of drugs including marijuana, cocaine, and alcohol. It is the most cost-effective approach for screening large population in community mass screening programs and for longitudinal sampling of hospitalized individuals aimed at monitoring viral load dynamics and treatment response. During the COVID-19 pandemic, scientific evidence emerged indicating that molecular tests performed on saliva have diagnostic sensitivity and specificity comparable to those observed with nasopharyngeal swabs for SARS-CoV-2 RNA detection. The presence of IgA and IgG antibodies at the mucosal level has been demonstrated to influence the progression of viral infection and the severity of clinical manifestation. As saliva contains both respiratory secretions and immunological components, it has wide applications, ranging from clinical diagnostics to post-vaccine disease burden and immunity surveillance.

Douglass Diak↗

Two-Phase Flow in Filters and Orifices: ISS Packed Bed Reactor Experiment Water Recovery Series (PBRE-WRS)

Understanding the hydrodynamics of adiabatic two-phase flows in packed bed reactors offers numerous benefits. It enables the optimization of chemical reactions rates and products which results in more efficient and compact reactors, thus reducing space and resource requirements, crucial for long duration space missions. The Packed Bed Reactor Experiment-Water Recovery Series (PBRE-WRS) is a flight experiment planned for operation on the Microgravity Science Glove box (MSG) facility of the International Space Station (ISS). The objective of the experiment is to validate hydrodynamic models at a range of gas and liquid flow rates, where these models are used in the design of processes for life support systems in microgravity. The microgravity environment allows for measurement and observation of aspects of fluid dynamics that are unique when compared to observations made in full or partial gravity environments. The experiment consists of testing two-phase flow hydrodynamics in three different filters, four (4) orifices and one check valve test articles. The experiment utilizes the hardware of the previously flown PBRE and PBRE-2 with packed beds of different packings materials and sizes. The fluid system of the PBRE-WRS consists of a nitrogen gas delivery and water delivery subsystems. The gas delivery subsystem can accommodate two ranges of gas flow rates, just as for the water delivery system. The nitrogen gas loop is open whereas the water loop is closed. Gas is separated from the water using a gas-liquid phase separator which is located in the water delivery module. Preliminary results from ground testing show the pressure drop across the filters increasing at different rates with the liquid and gas flow rates. In this work, a detailed system description is presented along with a summary of results from ground performance testing of different test sections in an end-to-end preflight testing campaign.

ISS↗

High resolution pipette

A pipette includes a movable piston and a diaphragm that at least partly defines a fluid chamber enclosing a volume of working fluid. The piston displaces a volumetric amount of the working fluid in the chamber when moved. In response, the diaphragm displaces a smaller volumetric amount of fluid outside the chamber. A deamplification ratio is defined by the ratio of the volume displaced by the diaphragm to the volume displaced by the piston. The deamplification ratio is adjustable by adjusting or changing the diaphragm and/or by adjusting the size of the fluid chamber. The deamplifying pipette enables measuring and dispensing of very small volumes of liquid and is easily adapted to commercially available pipette components. Pipette components such as a pipette tip or adaptor may include a diaphragm to enable deamplification of the nominal volume capacity of a given pipette device.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Eulerian Two-Fluid RANS-based CFD Simulations of a Helical Coil Steam Generator Boiling Tube

As part of a larger effort to demonstrate a simulation-based capability for the evaluation and optimization of helical coil steam generators, the performance of a helical coil steam generator tube is being considered using a Eulerian two-fluid multiphase flow capability implemented within the commercial computational fluid dynamics (CFD) code STAR-CCM+. The objective of these evaluations is to characterize boiling and the resultant two-phase flow structures within the helical coil heat exchanger tube so that structural analyses can more accurately account for vibration sources and damping. These studies have shown that CFD predictions using the two-fluid model are consistent with published measurements of pressure drop and heat transfer characteristics. The sensitivity of model predictions to both flow conditions and modeling parameters associated with bubble dynamics closure models has been investigated.

Pointer, Dave↗

Examining Two-Phase Flow with Optical Sensors

In lieu of the events that occurred at Fukushima in 2011, passive safety shutdowns for nuclear reactors has become a focus area for recent research. At Argonne National Laboratory this research has been simulated using air as a means of cooling down a experimental reactor core. This operates on the principals of natural convection and can be further studied in the report devised by Lisowski et al. in 2014. The air reactor cavity cooling system (RCCS) at Argonne National Laboratory is currently being transitioned into a water cooled system for passive safety reactor shutdown systems. In this system eight water pipes (1.5'' schedule 160 stainless steel) will transfer heat by means of natural convection. However, the primary network pipe will be 4 inch schedule 40 stainless steel pipe. The adiabatic chimney portion of this piping segment will be under analysis for void fraction. Based on the internal temperature of the water pipes, the characteristic regimes of two-phase flow that could exist inside of the pipe are an area of interest for experimental analysis. Determining which phase the water exists is instrumental to understanding the state of the processes inside of the water cooling pipe. Knowledge of these states allows for analysis of the efficiency of the RCCS as it shuts down. The state of two-phase flow can be measured by the analysis of the fluids void fraction.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Rheo-Structural Spectroscopy: Fingerprinting the In Situ Response of Fluids to Arbitrary Flow Fields

The objectives of this project were to develop new sample environments, measurement methodologies and associated modeling tools for characterizing the structural response to arbitrarily complex processing flows using small angle scattering, and to apply these new tools for understanding the fundamental physics governing the structuring of anisotropic particulate and polymeric materials under flow histories and conditions relevant to industrial processing flows. The research resulted in the development and implementation of a new sample environment, the fluidic four roll mill (FFoRM), for in situ small angle neutron and X-ray scattering (SANS/SAXS) measurements. These measurements are capable of generating large data sets that “fingerprint” how a complex fluid responds to a wide range of flow histories involving time variations in deformation type and rate. New modeling tools were developed to extract detailed microstructural information from such data sets, including orientation distribution functions and interparticle correlation functions, as well as reduced-order parametric descriptors of these high-dimensional functions that can be used to readily map, visualize and interpret a fluid’s structural response to its flow history. These new tools were applied to a range of model materials involving elongated particle suspensions in order to provide new insights into the physics of how flow couples with orientational and structural order in complex flows, particularly under non-dilute conditions for which no accurate theories currently exist. Using these investigations, we elucidated a number of new insights into the fundamental phenomena driving such process-structure-property relationships. These findings provide guidance for the further development of rheological models, and ultimately can inform the rational and model-based design of flow processes to achieve optimized orientational ordering that is key to the properties and function of a wide range of energy-relevant materials.

36 MATERIALS SCIENCE↗

Requirements and Development of an Acceleration Measurement System for International Space Station Microgravity Science Payloads

The International Space Station is being developed by NASA and international partners as a versatile user platform to allow long term on-orbit investigations of a variety of scientific and technology arenas. In particular, scientific studies are planned within a research class known as microgravity science in areas such as biotechnology, combustion, fluid physics, and materials sciences. An acceleration measurement system is in development to aid such research conducted in the on-orbit conditions of apparent weightlessness. This system provides a general purpose acceleration measurement capability in support of these payloads and investigators. Such capability allows for systematic study of scientific phenomena by obtaining information regarding the local accelerations present during experiment operations. Preparations for implementing this flight measurement system involves two distinct stages: requirements development prior to initiating the design activity, and the design activity itself. This paper defines the requirements definition approach taken, provides an overview of the results of the requirements phase, and outlines the initial design considerations being addressed for this measurement system. Some preliminary engineering approaches are also described.

Sutliff, Thomas J.↗

The NASA Turbulent Heat Flux Experiments: Summary and Lessons Learned

The Turbulent Heat Flux (THX) experiments were conducted at NASA Glenn Research Center (GRC) in order to collect measurements of velocities and temperatures for computational fluid dynamics (CFD) validation of heated flows, with a focus on propulsion system components. The experiments spanned 5 phases; four of which were conducted in the GRC AeroAcoustic Propulsion Laboratory (AAPL) using the Small Hot Jet Flow Rig (SHJAR). In addition to making velocity measurements with Particle Image Velocimetry (PIV), the THX experiments introduced a new Raman-scattering based capability to measure temperatures. Computational studies were also conducted for each of the experimental configurations, in order to provide a baseline of expected CFD results and conduct an assessment of the capability of various CFD approaches for calculating flows where the turbulent transport of heat was important. Two of the collected sets of data were used for American Institute of Aeronautics and Astronautics (AIAA) Propulsion Aerodynamic Workshops (PAWs). The data set from the 5th phase, collected for heated supersonic jets, was also used to construct new validation cases for the NASA Turbulence Model Resource (TMR). This paper provides an overview of the experiments and associated computations for each of the 5 test phases. Key experimental findings are presented. Lessons learned are provided concerning the effect of computational modeling choice on accuracy of predicting turbulent flows where thermal transport is important. Emphasis is placed on comparing Reynolds- averaged Navier-Stokes approaches with large-eddy simulation approaches. The benefits of utilizing a conjugate heat transfer method in conjunction with CFD solver for film cooling is demonstrated.

RANS↗

The NASA Turbulent Heat Flux (THX) Experiments: Summary and Lessons Learned

The Turbulent Heat Flux (THX) experiments were conducted at NASA Glenn Research Center (GRC) in order to collect measurements of velocities and temperatures for computational fluid dynamics (CFD) validation of heated flows, with a focus on propulsion system components. The experiments spanned 5 phases; four of which were conducted in the GRC AeroAcoustic Propulsion Laboratory (AAPL) using the Small Hot Jet Flow Rig (SHJAR). In addition to making velocity measurements with Particle Image Velocimetry (PIV), the THX experiments introduced a new Raman-scattering based capability to measure temperatures. Computational studies were also conducted for each of the experimental configurations, in order to provide a baseline of expected CFD results and conduct an assessment of the capability of various CFD approaches for calculating flows where the turbulent transport of heat was important. Two of the collected sets of data were used for American Institute of Aeronautics and Astronautics (AIAA) Propulsion Aerodynamic Workshops (PAWs). The data set from the 5th phase, collected for heated supersonic jets, was also used to construct new validation cases for the NASA Turbulence Model Resource (TMR). This paper provides an overview of the experiments and associated computations for each of the 5 test phases. Key experimental findings are presented. Lessons learned are provided concerning the effect of computational modeling choice on accuracy of predicting turbulent flows where thermal transport is important. Emphasis is placed on comparing Reynolds-averaged Navier-Stokes approaches with large-eddy simulation approaches. The benefits of utilizing a conjugate heat transfer method in conjunction with CFD solver for film cooling is demonstrated.

RANS↗

Direct Numerical Simulation of Pore-Scale Flow in a Bead Pack: Comparison with Magnetic Resonance Imaging Observations

A significant body of current research is aimed at developing methods for numerical simulation of flow and transport in porous media that explicitly resolve complex pore and solid geometries, and at utilizing such models to study the relationships between fundamental pore-scale processes and macroscopic manifestations at larger (i.e., Darcy) scales. A number of different numerical methods for pore-scale simulation have been developed, and have been extensively tested and validated for simplified geometries. However, validation of pore-scale simulations of fluid velocity for complex, three-dimensional (3D) pore geometries that are representative of natural porous media is challenging due to our limited ability to measure pore-scale velocity in such systems. Recent advances in magnetic resonance imaging (MRI) offer the opportunity to measure not only the pore geometry, but also local fluid velocities under steady-state flow conditions in 3D and with high spatial resolution. In this paper, we present a 3D velocity field measured at sub-pore resolution (tens of micrometers) over a centimeter-scale 3D domain using MRI methods. We have utilized the measured pore geometry to perform 3D simulations of Navier-Stokes flow over the same domain using direct numerical simulation techniques. We present a comparison of the numerical simulation results with the measured velocity field. It is shown that the numerical results match the observed velocity patterns well overall except for a variance and small systematic scaling which can be attributed to the known experimental error in the MRI measurements. The comparisons presented here provide strong validation of the pore-scale simulation methods and new insights for interpretation of uncertainty in MRI measurements of pore-scale velocity. This study also provides a potential benchmark for future comparison of other pore-scale simulation methods.

computational fluid dynamics↗

System and method for controlling metal oxide gel particle size

Metal oxide gel particles, may be prepared with a desired particle size, by preparing a low-temperature aqueous metal nitrate solution containing hexamethylene tetramine as a feed solution; and causing the feed solution to flow through a first tube and exit the first tube as a first stream at a first flow rate, so as to contact a high-temperature nonaqueous drive fluid. The drive fluid flows through a second tube at a second flow rate. Shear between the first stream and the drive fluid breaks the first stream into particles of the metal nitrate solution, and decomposition of hexamethylene tetramine converts metal nitrate solution particles into metal oxide gel particles. A metal oxide gel particle size is measured optically, using a sensor device directed at a flow of metal oxide gel particles within the stream of drive fluid. The sensor device measures transmission of light absorbed by either the metal oxide gel particles or the drive fluid, so that transmission of light through the drive fluid changes for a period of time as a metal oxide gel particle passes the optical sensor. If a measured particle size is not about equal to a desired particle size, the particle size may be corrected by adjusting a ratio of the first flow rate to a total flow rate, where the total flow rate is the sum of the first and second flow rates.

Linneen, Nicholas N.↗

System and method for controlling metal oxide gel particle size

Metal oxide gel particles, may be prepared with a desired particle size, by preparing a low-temperature aqueous metal nitrate solution containing hexamethylene tetramine as a feed solution; and causing the feed solution to flow through a first tube and exit the first tube as a first stream at a first flow rate, so as to contact a high-temperature nonaqueous drive fluid. The drive fluid flows through a second tube at a second flow rate. Shear between the first stream and the drive fluid breaks the first stream into particles of the metal nitrate solution, and decomposition of hexamethylene tetramine converts metal nitrate solution particles into metal oxide gel particles. A metal oxide gel particle size is measured optically, using a sensor device directed at a flow of metal oxide gel particles within the stream of drive fluid. The sensor device measures transmission of light absorbed by either the metal oxide gel particles or the drive fluid, so that transmission of light through the drive fluid changes for a period of time as a metal oxide gel particle passes the optical sensor. If a measured particle size is not about equal to a desired particle size, the particle size may be corrected by adjusting a ratio of the first flow rate to a total flow rate, where the total flow rate is the sum of the first and second flow rates.

Linneen, Nicholas↗

Multipurpose Thermal Insulation Test Apparatus

A multi-purpose thermal insulation test apparatus is used for testing insulation materials, or other components. The test apparatus is a fluid boil-off calorimeter system for calibrated measurement of the apparent thermal conductivity (k-value) of a specimen material at a fixed vacuum level. The apparatus includes an inner vessel for receiving a fluid with a normal boiling point below ambient temperature, such as liquid nitrogen, enclosed within a vacuum chamber. A cold mass assembly, including the inner vessel and thermal guards, is suspended from the top of the vacuum chamber. Handling tools attach to the cold mass assembly for convenient manipulation of the assembly and for the installation or wrapping of insulation test materials. Liquid nitrogen is typically supplied to the inner vessel using a fill tube with funnel. A single port through the top of the vacuum chamber facilitates both filling and venting. Aerogel composite stacks with reflective films are fastened to the top and the bottom of the inner vessel as thermal guards. The comparative k-value of the insulation material is determined by measuring the boil-off flow rate of gas, the temperature differential across the insulation thickness, and the dimensions (length and diameters) of the test specimen.

Fesmire, James E.↗

Investigations of the mechanisms by which lower body negative pressure (LBNP) improves orthostatic responses

Saline ingestion during LBNP is a counter measure proposed to improve orthostatic function during space flight. To understand the mechanism(s) responsible for this effect, body fluid, endocrine, and orthostatic responses (graded LBNP tests) were measured during bed rest (BR) and after 2 hr and 4 hr LBNP/saline treatments (-30 mm Hg and 1 liter of isotonic saline). PV (from I-125 and hematocrit measurements) decreased during BR but was restored to the pre-bed rest level (3157 +/- 161 ml) 20 hrs after both 2 hr (3109 +/- 146 ml) and 4 hr (3144 +/- 173 ml) LBNP. The heart rate response to graded LBNP tests was significantly improved after the 4 hr, but not after the 2 hr treatment. These results suggest PV expansion may be responsible for some improvement in orthostatic responses, but other mechanisms also must contribute.

Fortney, S. M.↗

Body fluid alterations during head-down bed rest in men at moderate altitude

To determine the effects of hypoxia on fluid balance responses to simulated zero-gravity, measurements were made in six subjects before and during -5 deg continuous head-down bed rest (HDBR) over 8 d at 10,678 ft. The same subjects were studied again at this altitude without HDBR as a control (CON) using a cross-over design. During this time, they maintained normal upright day-time activities, sleeping in the horizontal position at night. Fluid balance changes during HDBR in hypoxia were more pronounced than similar measurements previously reported from HDBR studies at sea level. Plasma volume loss was slightly greater and the diuresis and natriuresis were doubled in magnitude as compared to previous studies in normoxia and sustained for 4 d during hypoxia. These changes were associated with an immediate but transient rise in plasma atrial natriuretic peptide (ANP) to day 4 of 140 percent in HDBR and 41 percent in CON (p less than 0.005), followed by a decline towards baseline. Differences were less striking between HDBR and CON for plasma antidiuretic hormone and aldosterone, which were transiently reduced by HDBR. Plasma catecholamines showed a similar pattern to ANP in both HDBR and CON, suggesting that elevated ANP and catecholamines together accounted for the enhanced fluid shifts with HDBR during hypoxia.

Loeppky, J. A.↗