Search NASA⌕ Search

SEARCH · Search NASA

Results for “Factor Analysis, Statistical”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Cubic AgMnSbTe 3 Semiconductor with a High Thermoelectric Performance

The reaction of MnTe with AgSbTe 2 in an equimolar ratio (ATMS) provides a new semiconductor, AgMnSbTe 3 . AgMnSbTe 3 crystallizes in an average rock-salt NaCl structure with Ag, Mn, and Sb cations statistically occupying the Na sites. AgMnSbTe 3 is a p-type semiconductor with a narrow band gap of ~0.33 eV. A pair distribution function analysis indicates that local distortions are associated with the location of the Ag atoms in the lattice. Density functional theory calculations suggest a specific electronic band structure with multi-peak valence band maxima prone to energy convergence. In addition, Ag 2 Te nanograins precipitate at grain boundaries of AgMnSbTe 3 . Here, the energy offset of the valance band edge between AgMnSbTe 3 and Ag 2 Te is ~0.05 eV, which implies that Ag 2 Te precipitates exhibit a negligible effect on the hole transmission. As a result, ATMS exhibits a high power factor of ~12.2 μWcm -1 K -2 at 823 K, ultralow lattice thermal conductivity of ~0.34 Wm -1 K -1 (823 K), high peak ZT of ~1.46 at 823 K, and high average ZT of ~0.87 in the temperature range of 400–823 K.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of advanced fuel system concepts for commercial aircraft

An analytical study was performed in order to assess relative performance and economic factors involved with alternative advanced fuel systems for future commercial aircraft operating with broadened property fuels. The DC-10-30 wide-body tri-jet aircraft and the CF6-8OX engine were used as a baseline design for the study. Three advanced systems were considered and were specifically aimed at addressing freezing point, thermal stability and lubricity fuel properties. Actual DC-10-30 routes and flight profiles were simulated by computer modeling and resulted in prediction of aircraft and engine fuel system temperatures during a nominal flight and during statistical one-day-per-year cold and hot flights. Emergency conditions were also evaluated. Fuel consumption and weight and power extraction results were obtained. An economic analysis was performed for new aircraft and systems. Advanced system means for fuel tank heating included fuel recirculation loops using engine lube heat and generator heat. Environmental control system bleed air heat was used for tank heating in a water recirculation loop. The results showed that fundamentally all of the three advanced systems are feasible but vary in their degree of compatibility with broadened-property fuel.

Coffinberry, G. A.↗

Whose Gas is it anyway? Differentiating the Source of a Large Soil Vapor Plume beneath Two Adjacent Waste Sites - 20487

DOE contractor CH2M Hill Plateau Remediation Company is currently responsible for conducting groundwater contamination monitoring at several RCRA treatment, storage, and disposal units located on the Hanford Site in Richland, Washington State. The Nonradioactive Dangerous Waste Landfill treatment, storage, and disposal unit presents a distinct groundwater monitoring problem because of a large multi-contaminant soil vapor plume beneath it that is a likely source of low-level volatile organic compound groundwater contamination. Adjacent to Nonradioactive Dangerous Waste Landfill is the Solid Waste Landfill. Volatile organic compounds are inventory components of both the Nonradioactive Dangerous Waste Landfill and the Solid Waste Landfill. Therefore, it is possible that both sites could be contributing to the soil vapor plume. For regulatory purposes, it is important to differentiate which site is the primary contributor of volatile organic compounds to the plume. An approach was developed to identify the primary volatile organic compound source of the soil vapor plume beneath Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. The site conceptual model hypothesis of vapor-phase volatile organic compound transport to the dissolved phase in groundwater was tested by a simple mathematical model of vapor/liquid equilibrium concentrations at the groundwater/air interface. Once it was shown that vapor-phase volatile organic compound transport to groundwater was a valid conceptual model for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill, spatial and statistical methods were used to determine the primary site contributing to the majority of volatile organic compounds to the soil vapor plume. Average groundwater chloroform, tetrachloroethene, and trichloroethene concentrations from Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring network wells were plotted on maps of the facilities and immediate vicinities and compared to soil vapor sampling probe locations. Principal component analysis and mixing ratios were used to identify source contributions of each treatment, storage, and disposal unit to the plume. Results of the vapor/liquid equilibrium concentrations mathematical model showed that transport phenomena outweigh steady-state equilibria. Estimated vapor/liquid equilibrium concentrations were considerably lower than soil vapor measurements. The results indicate that dynamic vadose zone and groundwater factors such as decreased vapor concentrations with depth, vapor dilution from dispersion in the vadose zone, and advective and diffusional volatile organic compound dilution in groundwater result in groundwater volatile organic compound concentrations much less than would be measured under steady-state equilibrium conditions. Site source contribution differentiation by principal component analysis and mixing ratios was inconclusive using actual soil gas data because of the similarity in concentration values in both datasets for Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill. Similar data populations suggest mixing of the vapor contributions from both sites by dispersion through the soil matrix pore spaces. However, when groundwater volatile organic compound data were compared between the Nonradioactive Dangerous Waste Landfill and Solid Waste Landfill monitoring networks, Solid Waste Landfill mean concentrations were higher, suggesting more vapor-phase volatile organic compound transport to groundwater at those locations. Simulated volatile organic compound soil vapor and groundwater datasets created to test the methods developed for this study show that the method can be successful in source differentiation when significantly different datasets are compared. This paper will describe a method of testing a conceptual model for vapor-phase contaminant transport to groundwater and for differentiating site sources of contaminants comprising a mixed-constituent soil vapor plume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Survival fraction and phenotype alterations of Xenopus laevis embryos at 3 Gy, 150 kV X-ray irradiation

To determine the radiosensitivity of Xenopus laevis embryos, aquatic organism model, for toxicity studies utilizing X-rays at acute high dose levels, by analysing its survival fraction and phenotype alterations under one-exposure integral dose. We used the standard Frog Embryo Teratogenesis Assay Xenopus test during the early stages of X. laevis development. The embryos were harvested until st. 46 when they were irradiated. The radiation effects were checked daily for a week and the survival, malformations and growth inhibition were assessed. Sibling tadpoles as control organisms were used. Statistical analysis was performed to assess the extent of any damage. Irradiation was performed with an X-ray tube operated at 150 kV. The tube containing the tadpoles was exposed to an air kerma of 3 Gy as measured in air with an in-beam ionization chamber. After one week, survival fraction of irradiated embryos was 58%, while for control embryos it was 81%. Hence, irradiation with 150 kV, 3 Gy X-rays produced a 23% decrease of survival in regard to unirradiated embryos. The 70% of the irradiated embryos showed an altered distribution of the skin pigmentation, in particular on the dorsal area and in the olfactory pits, where the pigment concentration increased by a factor 2. In conclusion exposure of X. laevis to 3 Gy, 150 kV X-rays induced a reduction of embryos survival and a significant modification of pigmentation. The authors think that X. laevis embryos, at st 46, is a suitable biological model for large scale investigations on the effects of ionizing radiation.

60 APPLIED LIFE SCIENCES↗

Testing non-minimally coupled inflation with CMB data: a Bayesian analysis

We use the most recent cosmic microwave background (CMB) data to perform a Bayesian statistical analysis and discuss the observational viability of inflationary models with a non-minimal coupling, ξ, between the inflaton field and the Ricci scalar. We particularize our analysis to two examples of small and large field inflationary models, namely, the Coleman-Weinberg and the chaotic quartic potentials. We find that ( i ) the ξ parameter is closely correlated with the primordial amplitude ; ( ii ) although improving the agreement with the CMB data in the r − n {sub s} plane, where r is the tensor-to-scalar ratio and n {sub s} the primordial spectral index, a non-null coupling is strongly disfavoured with respect to the minimally coupled standard ΛCDM model, since the upper bounds of the Bayes factor (odds) for ξ parameter are greater than 150:1.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of the D+ --> K- pi+ e+ nu_e decay channel

Using 347.5 fb{sup -1} of data recorded by the BABAR detector at the PEP-II electron-positron collider, 244 x 10{sup 3} signal events for the D{sup +} {yields} K{sup -}{pi}{sup +}e{sup +}{nu}{sub e} decay channel are analyzed. This decay mode is dominated by the {bar K}*(892){sup 0} contribution. We determine the {bar K}*(892){sup 0} parameters: m{sub K*(892){sup 0}} = (895.4{+-}0.2{+-}0.2) MeV/c{sup 2}, {Lambda}{sub K*(892){sup 0}}{sup 0} = (46.5{+-}0.3{+-}0.2) MeV/c{sup 2} and the Blatt-Weisskopf parameter r{sub BW} = 2.1{+-}0.5{+-}0.5 (GeV/c){sup -1} where the first uncertainty comes from statistics and the second from systematic uncertainties. We also measure the parameters defining the corresponding hadronic form factors at q{sup 2} = 0 (r{sub V} = V(0)/A{sub 1}(0) = 1.463{+-}0.017{+-}0.031, r{sup 2} = A{sub 2}(0)/A{sub 1}(0) = 0.801{+-}0.020{+-}0.020) and the value of the axial-vector pole mass parameterizing the q{sup 2} variation of A{sub 1} and A{sub 2}: m{sub A} = (2.63{+-}0.10{+-}0.13) GeV/c{sup 2}. The S-wave fraction is equal to (5.79{+-}0.16{+-}0.15)%. Other signal components correspond to fractions below 1%. Using the D{sup +} {yields} K{sup -}{pi}{sup +}{pi}{sup +} channel as a normalization, we measure the D{sup +} semileptonic branching fraction: {Beta}(D{sup +} {yields} K{sup -}{pi}{sup +}e{sup +}{nu}{sub e}) = (4.00 {+-} 0.03 {+-} 0.04 {+-} 0.09) x 10{sup -2} where the third uncertainty comes from external inputs. We then obtain the value of the hadronic form factor A{sub 1} at q{sup 2} = 0: A{sub 1}(0) = 0.6200 {+-} 0.0056 {+-} 0.0065 {+-} 0.0071. Fixing the P-wave parameters we measure the phase of the S-wave for several values of the K{pi} mass. These results confirm those obtained with K{pi} production at small momentum transfer in fixed target experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Probing cosmic strings with satellite CMB measurements

We study the problem of searching for cosmic string signal patterns in the present high resolution and high sensitivity observations of the Cosmic Microwave Background (CMB). This article discusses a technique capable of recognizing Kaiser-Stebbins effect signatures in total intensity anisotropy maps from isolated strings. We derive the statistical distributions of null detections from purely Gaussian fluctuations and instrumental performances of the operating satellites, and show that the biggest factor that produces confusion is represented by the acoustic oscillation features of the scale comparable to the size of horizon at recombination. Simulations show that the distribution of null detections converges to a χ{sup 2} distribution, with detectability threshold at 99% confidence level corresponding to a string induced step signal with an amplitude of about 100 μK which corresponds to a limit of roughly Gμ ∼ 1.5 × 10{sup −6}. We implement simulations for deriving the statistics of spurious detections caused by extra-Galactic and Galactic foregrounds. For diffuse Galactic foregrounds, which represents the dominant source of contamination, we construct sky masks outlining the available region of the sky where the Galactic confusion is sub-dominant, specializing our analysis to the case represented by the frequency coverage and nominal sensitivity and resolution of the Planck experiment. As for other CMB measurements, the maximum available area, corresponding to 7%, is reached where the foreground emission is expected to be minimum, in the 70–100 GHz interval.

79 ASTRONOMY AND ASTROPHYSICS↗

Axial-vector form factors of the nucleon from lattice QCD

In this paper, we present results for the form factors of the isovector axial vector current in the nucleon state using large scale simulations of lattice QCD. The calculations were done using eight ensembles of gauge configurations generated by the MILC collaboration using the HISQ action with 2 + 1 + 1 dynamical flavors. These ensembles span three lattice spacings a ≈ 0.06 , 0.09, and 0.12 fm and light-quark masses corresponding to the pion masses M π ≈ 135, 225, and 310 MeV. High-statistics estimates allow us to quantify systematic uncertainties in the extraction of G A (Q 2 ) and the induced pseudoscalar form factor G P (Q 2 ) . We perform a simultaneous extrapolation in the lattice spacing, lattice volume and light-quark masses of the axial charge radius r A data to obtain physical estimates. Using the dipole ansatz to fit the Q 2 behavior we obtain r A | dipole = 0.49(3) fm , which corresponds to M A = 1.39(9) GeV , and is consistent with M A = 1.35(17) GeV obtained by the miniBooNE collaboration. The estimate obtained using the z -expansion is r A | z - expansion = 0.46(6) fm, and the combined result is r A | combined = 0.48(4) fm. Analysis of the induced pseudoscalar form factor G P (Q 2 ) yields low estimates for g* P and g π NN compared to their phenomenological values. To understand these, we analyze the partially conserved axial current (PCAC) relation by also calculating the pseudoscalar form factor. Lastly, we find that these low values are due to large deviations in the PCAC relation between the three form factors, and in the pion-pole dominance hypothesis.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Computational Review of Privacy-Preserving Mechanisms for the Smart Grid

Smart grid technologies have rapidly become one of the largest and most comprehensive sources of data for the modern utility. For the most part, data streams are seen as an essential tool that enable utilities to carry their day-to-day business operations, but they also create the need for efficient and secure data management strategies. In the context of the smart grid, ensuring data privacy is becoming an increasing concern due to a combination of factors that range from shifts in operational paradigms and rapid technology evolution to changes in legislation. Furthermore, researchers have highlighted the risks associated with improperly protected energy records. For example, energy consumption data from homes could be used to infer the behaviors and habits of home occupants through activity recognition or user profiling (Fan, 2017), which may lead to unfair service pricing, targeted advertising, or other personal security violations. Similarly, Electric Vehicles’ (EVs) charging metadata could be used to reveal private information about the owner such as their payment methods, preferred charging stations, and other locational and timing information that could be used to reconstruct the vehicle owner’s behaviors. The privacy of user data, even when used for statistical analysis or machine learning training processes, also needs to be carefully considered, as an individual’s private traits may still be vulnerable if their inclusion/exclusion greatly impacts the result or could be linked to a public dataset through cross-reference. The breach of user privacy also has severe impacts for organizations that store, transmit, or work on the data in the form of diminishing the public’s trust in them while potentially incurring legal consequences (e.g., fines and suspensions under the European Union General Data Protection Regulation, Health Insurance Portability and Accountability Act, etc.). Because of these risks, several privacy-preserving mechanisms are available to help organizations comply with privacy legislations and prevent the unauthorized and malicious use of user data. In light of these concerns, this report focuses on performing a computational review of privacy-preserving mechanisms that have received a significant amount of interest in literature. It specifically focuses on 1) homomorphic encryption, 2) zero-knowledge proofs, 3) differential privacy, and 4) federated learning. It is worth noting that although many of the methods presented in this document rely on cryptographic primitives, their intent is not to provide perfect secrecy, but rather to enable users to maintain privacy, and thus they shall not be compared or equated to other constructs that are aimed to address cybersecurity constructs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Effectiveness of Radiotherapy for Elderly Patients With Glioblastoma

Purpose: Radiotherapy plays a central role in the definitive treatment of glioblastoma. However, the optimal management of elderly patients with glioblastoma remains controversial, as the relative benefit in this patient population is unclear. To better understand the role that radiation plays in the treatment of glioblastoma in the elderly, we analyzed factors influencing patient survival using a large population-based registry. Methods and Materials: A total of 2,836 patients more than 70 years of age diagnosed with glioblastoma between 1993 and 2005 were identified from the Surveillance, Epidemiology, and End Results (SEER) registry. Demographic and clinical variables used in the analysis included gender, ethnicity, tumor size, age at diagnosis, surgery, and radiotherapy. Cancer-specific survival and overall survival were evaluated using the Kaplan-Meier method. Univariate and multivariate analysis were performed using Cox regression. Results: Radiotherapy was administered in 64% of these patients, and surgery was performed in 68%. Among 2,836 patients, 46% received surgery and radiotherapy, 22% underwent surgery only, 18% underwent radiotherapy only, and 14% did not undergo either treatment. The median survival for patients who underwent surgery and radiotherapy was 8 months. The median survival for patients who underwent radiotherapy only was 4 months, and for patients who underwent surgery only was 3 months. Those who received neither surgery nor radiotherapy had a median survival of 2 months (p < 0.001). Multivariate analysis showed that radiotherapy significantly improved cancer-specific survival (hazard ratio [HR], 0.43, 95% confidence interval [CI] 0.38-0.49) after adjusting for surgery, tumor size, gender, ethnicity, and age at diagnosis. Other factors associated with Cancer-specific survival included surgery, tumor size, age at diagnosis, and ethnicity. Analysis using overall survival as the endpoint yielded very similar results. Conclusions: Elderly patients with glioblastoma who underwent radiotherapy had improved cancer-specific survival and overall survival compared to patients who did not receive radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

An X-Ray Periodicity of ∼1.8 hr in Narrow-line Seyfert 1 Galaxy Mrk 766

In the narrow-line Seyfert 1 galaxy Mrk 766, a quasi-periodic oscillation (QPO) signal with a period of ∼6450 s is detected in the XMM-Newton data collected on 2005 May 31. This QPO signal is highly statistically significant at the ∼5σ confidence level, with a quality factor of Q=f/Δf>13.6. The X-ray intensity changed by a factor of 3, with a root mean square fractional variability of 14.3%. Furthermore, this QPO signal is present in the data of all three EPIC detectors and two RGS cameras and its frequency follows the f{sub QPO}–M{sub BH} relation spanning from stellar-mass to supermassive black holes. Interestingly, a possible QPO signal with a period of ∼4200 s had been reported in the literature. The frequency ratio of these two QPO signals is ∼3:2. Our result is also in support of the hypothesis that the QPO signals can just be transient. The spectral analysis reveals that the contribution of the soft excess component below ∼1 keV is different between epochs with and without QPO. This property, as well as the former frequency ratio, are well-detected in X-ray BH binaries, which may shed some light on the physical origins of our event.

79 ASTRONOMY AND ASTROPHYSICS↗

On the radio variability of V410 Tauri

The radio flux density of the star V410 Tauri has been monitored at 6 and 2 cm wavelengths at monthly intervals over a one-year period with the VLA. In contrast to earlier observations, the radio emission was typically at the level of roughly 1 mJy with flat or negative spectral indices. No large radio 'flare' events were detected. However, a periodicity analysis of the quiescent data shows statistically significant evidence for a modulation of the radio emission, with a period of 0.933 days, or one-half the optical period reported by Vrba, et al. (1988). If the modulation is real, it would imply that (1) the radio emission is produced either in localized zones on two opposite hemispheres of the star, or in a single, presumably high-latitude, structure that remains visible for an entire rotation period; (2) this zone or zones must be comparable to the stellar radius in size; (3) the energy spectrum of the radiating electrons is stable over long times (greater than 1 yr) but the absolute intensity level in the quiescent state may vary by factors of a few; and (4) the emission solid angle varies with viewing angle of the emission zone. It is suggested that gyrosynchrotron radiation from closed-loop magnetic structures may be responsible for the quasisteady low-level radio emission reported here. A geometric model for the radio emission structure may explain qualitatively the modulation of the radio emission. By analogy with the premain-sequence star DoAr 21, this same physical mechanism may produce both the 'quiescent' and 'flaring' radio emission. The monitoring results suggest that strong radio outbursts, such as were previously observed for V410 Tau, are relatively rare.

Bieging, John H.↗

Predicting Biological Cleanliness: An Empirical Bayes Approach for Spacecraft Bioburden Accounting

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 MATHEMATICS AND COMPUTING↗

Bayesian Framework for Bioburden Density Estimation in Planetary Protection

To comply with the international planetary protection policy set forth by the Committee on Space Research and NASA Agency level requirements, spacecraft destined to biologically sensitive planetary bodies have to minimize terrestrial biological contamination. Analysis, testing and inspection are the standard forward verification activities that are used to demonstrate compliance with the biological contamination requirements. For testing of spacecraft surface areas, a swab or wipe sample is collected from surfaces prior to last access and subsequently processed in the lab using NASA Approved Planetary Protection Methods for Culture Based Assays. Raw data resulting from this assay is then statistically treated employing a mathematical paradigm stemming from the 1970’s Viking Lander Project to generate the bioburden density and total microbial bioburden present. This standard approach arbitrarily accounts for error and provides an upper conservative bound as it reports the maximum number of spores estimated to be present on flight hardware surfaces. A bioburden density estimate factors in the following variables: the observed bioburden count, representative volume processed, sampling efficiencies. Notably, to account for error in the approach, a 0 observed count is arbitrarily changed to a count of 1 for each hardware grouping. The data generated by spacecraft bioburden verification campaigns in the past have resulted in <80% of wipes and <90% of swabs containing a bioburden count of 0. As such, having a robust and well documented statistical approach for dealing with the probability of low incident rates is necessary to be able to estimate spacecraft bioburden. Being able to statistically describe the bioburden distribution and associated confidence level is a gamechanger for the development of bioburden allocations during mission design and will allow for tighter management of risk throughout spacecraft build. Thus, Empirical Bayes statistical approach was evaluated to estimate the microbial bioburden on spacecraft to mitigate the aforementioned mathematical concerns and provide a probabilistic bioburden distribution of the flight hardware surface. For application of this approach to performing bioburden calculations, a range of non-informative prior assumptions on hardware surfaces are explored for Bayesian analyses while informative priors using posterior distributions from prior assays are utilized for Empirical Bayes analyses. Several non-informative priors are currently under investigation to assess fitness including use of these priors to serve as a foundation to build off of NASA specification values or a basis of risk to account for unknowns during the integration and testing process. Informative priors under consideration are generated using sampled bioburden values from hardware originating within like processing environments (e.g. vendor cleaning process or similar assembly process), temporal spacecraft status events as a prediction for hardware cleanliness of future samples, and heritage system bioburden actuals to predict allocation for subsequent missions. Informative priors and probabilistic bioburden distributions are then validated using data sets from the Mars Exploration Rover, Mars Science Laboratory, and InSight missions. Using Empirical Bayes approach to generate a probabilistic bioburden distribution as demonstrated through mission use cases provides a valid approach for use in the end-to-end requirements verification process.

97 - MATHEMATICS AND COMPUTING↗

Numerical Analysis of High-Order Modes in SRF Resonators for Particle Accelerators

Over the past decades, superconducting technology has rapidly evolved towards high accelerating gradients and low surface resistance, making it possible to operate particle accelerators with high average beam currents and large duty factors. However, RF losses due to coherent excitation of the HOM become the limiting factor for these regimes. Unlike the cavity operating mode, which is tuned separately, the HOM parameters can significantly vary from one cavity to another due to finite mechanical tolerances during the manufacturing process. Thus, it is of utmost importance to know the HOM parameter spread in advance in order to predict unexpected cryogenic losses, overheating of beam line components and maintain stable beam dynamics. In this paper, we present a method for generating cavity geometry with an arbitrary spread of mechanical imperfections and numerically evaluating HOM statistics. Knowing the spread of HOM parameters, we calculated the probability of resonant HOM losses in SRF accelerating cavities used in CW beam current machines such as the PIP-II and LCLS-II linacs, as well as for the SRF crab-cavity for the ILC project. Finally, we present experimental results of HOM spectra measurements in hundreds of 1.3 GHz cavities installed in LCLS-II cryomodules. Studying the effects of HOM excitation results in specifications of the SRF cavity and cryomodule and can significantly impact the efficiency and reliability of the machine operation.

Lunin, Andrei [Fermilab] (ORCID:0000000290096792)↗

Patient Compliance with Surveillance Following Elective Endovascular Aneurysm Repair

PurposeIntegral to maintaining good outcomes post-endovascular aneurysm repair (EVAR) is a robust surveillance protocol. A significant proportion of patients fail to comply with surveillance, exposing themselves to complications. We examine EVAR surveillance in Wessex (UK), exploring factors that may predict poor compliance.MethodsRetrospective analysis of 179 consecutive elective EVAR cases [2008–2013] was performed. 167 patients were male, with the age range of 50–95. Surveillance was conducted centrally (tertiary referral trauma centre) and at four spoke units. Surveillance compliance and predictors of non-compliance including age, gender, co-morbid status, residential location and socioeconomic status were analysed for univariate significance.ResultsFifty patients (27.9 %) were non-compliant with surveillance; 14 (8.1 %) had no imaging post-EVAR. At 1 year, 56.1 % (of 123 patients) were compliant. At years 2 and 3, 41.5 and 41.2 % (of 65 and 34 patients, respectively) were compliant. Four years post-EVAR, only one of eight attended surveillance (12.5 %). There were no statistically significant differences in age (p = 0.77), co-morbid status or gender (p = 0.64). Distance to central unit (p = 0.67) and surveillance site (p = 0.56) was non-significant. While there was a trend towards compliance in upper-middle-class socioeconomic groups (ABC1 vs. C1C2D), correlating with >50 % of non-compliant patients living within <10 mile radius of the central unit, overall predictive value was not significant (p = 0.82).ConclusionsCompliance with surveillance post-EVAR is poor. No independent predictor of non-compliance has been confirmed, but socioeconomic status appears to be relevant. There is a worrying drop-off in attendance beyond the first year. This study highlights a problem that needs to be addressed urgently, if we are to maintain good outcomes post-EVAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of Vision Loss Caused by Radiation-Induced Optic Neuropathy After Particle Therapy for Head-and-Neck and Skull-Base Tumors Adjacent to Optic Nerves

Purpose: To assess the incident rates of vision loss (VL; based on counting fingers or more severe) caused by radiation-induced optic neuropathy (RION) after particle therapy for tumors adjacent to optic nerves (ONs), and to evaluate factors that may contribute to VL. Methods and Materials: From August 2001 to August 2006, 104 patients with head-and-neck or skull-base tumors adjacent to ONs were treated with carbon ion or proton radiotherapy. Among them, 145 ONs of 75 patients were irradiated and followed for greater than 12 months. The incident rate of VL and the prognostic factors for occurrence of VL were evaluated. The late effects of carbon ion and proton beams were compared on the basis of a biologically effective dose at alpha/beta = 3 gray equivalent (GyE{sub 3}). Results: Eight patients (11%) experienced VL resulting from RION. The onset of VL ranged from 17 to 58 months. The median follow-up was 25 months. No significant difference was observed between the carbon ion and proton beam treatment groups. On univariate analysis, age (>60 years), diabetes mellitus, and maximum dose to the ON (>110 GyE{sub 3}) were significant, whereas on multivariate analysis only diabetes mellitus was found to be significant for VL. Conclusions: The time to the onset of VL was highly variable. There was no statistically significant difference between carbon ion and proton beam treatments over the follow-up period. Based on multivariate analysis, diabetes mellitus correlated with the occurrence of VL. A larger study with longer follow-up is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Scaling Input Distributions for Probabilistic Models - 19472

It is important to address scaling issues when building models to support risk-based decisions for radioactive waste disposal sites. Currently, probabilistic risk assessment and probabilistic performance assessment models are run for multiple realizations where each realization uses one value from each input distribution over the entire modeled time. The input distributions represent the current state of knowledge in the mean of the input variable over the spatial region of interest and over the time period of the model run. This paper focuses on the time factor in input distribution scaling because it presents more serious conceptual and distributional challenges than the spatial factor. One of the challenges in temporal scaling is the effect of non-linearity on propagation of distribution uncertainty through to uncertainty in results. Radioactive waste disposal models tend to have both linear and non-linear components in their models. Dose assessment calculations are typically represented by linear models, while contaminant transport models have linear and non-linear components. In principle, temporal scaling of input parameter distributions for a linear model is straightforward, but scaling of input distributions for non-linear models is not. This paper uses examples to investigate the effects of input distribution temporal scaling on simple linear and non-linear models. Different scaling scenarios were investigated by comparing three analysis tools: analytical mathematical representations, statistical software programming, and GoldSim Monte Carlo simulation software. R statistical software is an open source statistical programming language often used for statistical analyses and graphical representation of data. GoldSim is a robust probabilistic dynamic modeling platform used in performance assessment modeling of radioactive waste sites. A simple linear model, a quadratic model and a multiplicative model were the cases explored for each of these tools. For the three analysis tools considered and with each of the scaling cases, 1,000 realizations were implemented from distributions of the random variables of interest. This is a sufficient number of realizations for simple models to capture the model space. An annual temporal resolution of a 100-year simulation period was chosen for all models and analysis tools. The effects of temporal scaling were demonstrated by investigating two different options for time scaling. Option 1 was set up so that the input distributions represented the expected value on an annual time scale, and a new value from that distribution was chosen every year (at every time step which equaled a year) for 100 years. In Option 2, the input distributions were scaled to represent the expected mean value of the input variable over the 100 years of simulation, and one value from that distribution was chosen for the entire elapsed time. Results show agreement across the three analysis tools. As expected, the linear models have identical results for the two different scaling Options, and the non-linear models diverge in the results for different time scale implementation. The implications of this work point to the need for careful consideration of input distribution temporal scaling. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗