Search NASA⌕ Search

SEARCH · Search NASA

Results for “Filtering techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

X-ray Computed Tomography of Irradiated and Unirradiated AGR-3/4 Compacts

X-ray Computed Tomography (XCT) has been utilized to image and characterize compacts from the combined third and fourth irradiation of the Advanced Gas Reactor (AGR) Program, AGR-3/4, fuel. The experiment contained tristructural isotropic (TRISO)-coated fuel particles as well as designed-to-fail (DTF) fuel particles. Two irradiated compacts, representing the lower and higher range of AGR-3/4 burnup (4.85% and 14.92% fissions per initial heavy metal atom FIMA) were examined. These represent the first known highly irradiated TRISO fuel compacts to be examined via X-ray CT. Additionally, two unirradiated compacts from the same production batch as the examined irradiation compacts were also imaged for a baseline comparison. As XCT of irradiated TRISO compacts is not a commonly implemented characterization technique, a significant portion of the report focuses on developed methodology and imaging conditions. A specialized sample shielding device was developed and fabricated specifically to limit received dose to staff during sample preparation for XCT and to minimize excess gamma radiation dose to sensitive electronic components with the utilized X-ray system. Significant penetration through the uranium oxycarbide fuel kernels by significantly hardening the X-ray beam with specialized proprietary filters acquired from Carl Zeiss NTS Ltd. The filter utilized resulted in an average X ray photon energy of ~110 keV which approaches uranium’s K-edge (~115 keV), maximizing penetration for a microfocus X-ray source. The gamma-radiation emitted from the irradiated AGR-3/4 TRISO compacts, has the same properties and mechanisms for interaction with matter as X-rays, thus the detection of gamma-radiation by the utilized X-ray detectors was initially a concern. However, although ?-rays did produce an observable signal on the X-ray detector, its contribution to the overall imaging results appeared negligible upon 3D reconstruction. The neglibile impact on the resulting 3D reconstructed volumes were likely the result of: (1) a significantly lower detection efficiency for ?-rays relative to X-rays; (2) An X-ray flux at the detector several orders of magnitude higher than that of the impinging ?-rays from the irradiated compacts. These results suggest that irradiated compacts with significantly higher radiation fields can be examined in the future if an acceptable route for sample handling and preparation can be determined. Additionally, the 3D imaging results of XCT can provide a valuable means of assessing compacts. While in many ways complimentary to traditional post irradiation examination techniques such as optical ceramography, XCT can provide additional insight into compact features traditionally difficult to discern directly from cross-sectional imaging alone. Preliminary analyses on kernel size, morphology (aspect ratio and sphericity), and kernel orientation were presented. Sphericity, a simple morphological shape descriptor, was utilized to screen for kernel extrusions within the high burnup compact. The number of kernel extrusions identified via XCT represented an approximate two-fold increase from the quantity of extruded particles observed (via optical ceramography) in adjacent compacts from the same irradiation capsule. While numerical analysis of the compact datasets was highly preliminary, initial results show promise for providing complimentary metrics to current AGR-3/4 PIE and potentially additional insight into the processes driving TRISO fuel degradation during reactor operation. Additional analyses to be performed at a later date include a more detailed examination of kernel size, kernel sphericity (and observed kernel extrusions), and sphericity. Given all particles can be observed in a single data volume possible correlation of spatial position with observed kernel features will also be made at a later date.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Monocrystalline diamond detector for ionizing radiation emitted by high temperature laser-generated plasma

A monocrystalline diamond detector was used for measurements of soft x-ray and ion emission from laser plasma obtained with the use of the PALS Asterix laser at intensities on the order of 10{sup 16} W/cm{sup 2} and pulse duration of 300 ps. Measurements were performed by varying the laser intensity and the focal position of the laser beam with respect to the target position. The spectra were obtained with the use of a diamond detector, which was without a filter, and showed not only the photopeak due to UV and soft x rays but also the ions emitted from the plasma. The detector was employed with absorbers of different thicknesses to determine, as a first approximation, the energy distribution of soft x-ray emission from the plasma. The time-of-flight technique was employed to determine the ion kinetic energies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SLUG-STOCHASTICALLY LIGHTING UP GALAXIES. I. METHODS AND VALIDATING TESTS

The effects of stochasticity on the luminosities of stellar populations are an often neglected but crucial element for understanding populations in the low-mass or the low star formation rate regime. To address this issue, we present SLUG, a new code to 'Stochastically Light Up Galaxies'. SLUG synthesizes stellar populations using a Monte Carlo technique that properly treats stochastic sampling including the effects of clustering, the stellar initial mass function, star formation history, stellar evolution, and cluster disruption. This code produces many useful outputs, including (1) catalogs of star clusters and their properties such as their stellar initial mass distributions and their photometric properties in a variety of filters, (2) two dimensional histograms of color-magnitude diagrams of every star in the simulation, and (3) the photometric properties of field stars and the integrated photometry of the entire simulated galaxy. After presenting the SLUG algorithm in detail, we validate the code through comparisons with STARBURST99 in the well-sampled regime, and with observed photometry of Milky Way clusters. Finally, we demonstrate SLUG's capabilities by presenting outputs in the stochastic regime. SLUG is publicly distributed through the Web site http://sites.google.com/site/runslug/.

79 ASTRONOMY AND ASTROPHYSICS↗

MAPPING THE GALAXY COLOR–REDSHIFT RELATION: OPTIMAL PHOTOMETRIC REDSHIFT CALIBRATION STRATEGIES FOR COSMOLOGY SURVEYS

Calibrating the photometric redshifts of ≳10{sup 9} galaxies for upcoming weak lensing cosmology experiments is a major challenge for the astrophysics community. The path to obtaining the required spectroscopic redshifts for training and calibration is daunting, given the anticipated depths of the surveys and the difficulty in obtaining secure redshifts for some faint galaxy populations. Here we present an analysis of the problem based on the self-organizing map, a method of mapping the distribution of data in a high-dimensional space and projecting it onto a lower-dimensional representation. We apply this method to existing photometric data from the COSMOS survey selected to approximate the anticipated Euclid weak lensing sample, enabling us to robustly map the empirical distribution of galaxies in the multidimensional color space defined by the expected Euclid filters. Mapping this multicolor distribution lets us determine where—in galaxy color space—redshifts from current spectroscopic surveys exist and where they are systematically missing. Crucially, the method lets us determine whether a spectroscopic training sample is representative of the full photometric space occupied by the galaxies in a survey. We explore optimal sampling techniques and estimate the additional spectroscopy needed to map out the color–redshift relation, finding that sampling the galaxy distribution in color space in a systematic way can efficiently meet the calibration requirements. While the analysis presented here focuses on the Euclid survey, similar analysis can be applied to other surveys facing the same calibration challenge, such as DES, LSST, and WFIRST.

79 ASTRONOMY AND ASTROPHYSICS↗

Analysis of fission gas release kinetics by on-line mass spectrometry

The release of fission gas (Xe and Kr) and helium out of nuclear fuel materials in normal operation of a nuclear power reactor can constitute a strong limitation of the fuel lifetime. Moreover, radioactive isotopes of Xe and Kr contribute significantly to the global radiological source term released in the primary coolant circuit in case of accidental situations accompanied by fuel rod loss of integrity. As a consequence, fission gas release investigation is of prime importance for the nuclear fuel cycle economy, and is the driven force of numerous R and D programs. In this domain, for solving current fuel behavior understanding issues, preparing the development of new fuels (e.g. for Gen IV power systems) and for improving the modeling prediction capability, there is a marked need for innovations in the instrumentation field, mainly for: . Quantification of very low fission gas concentrations, released from fuel sample and routed in sweeping lines. Monitoring of quick gas release variations by quantification of elementary release during a short period of time. Detection of a large range of atomic masses (e.g. H{sub 2}, HT, He, CO, CO{sub 2}, Ne, Ar, Kr, Xe), together with a performing separation of isotopes for Xe and Kr elements. Coupling measurement of stable and radioactive gas isotopes, by using in parallel mass spectrometry and gamma spectrometry techniques. To fulfill these challenging needs, a common strategy for analysis equipment implementation has been set up thanks to a recently launched collaboration between the CEA and the Univ. of Provence, with the technological support of the Liverpool Univ.. It aims at developing a chronological series of mass spectrometer devices based upon mass filter and 2D/3D ion traps with Fourier transform operating mode and having increasing levels of performances to match the previous challenges for out-of pile and in-pile experiments. The final objective is to install a high performance online mass spectrometer coupled to a gamma spectrometer in the fission product laboratory of the future Jules Horowitz Material Test Reactor. An intermediate step will consist of testing first equipment on an existing experimental facility in the LECA-STAR Hot Cell Laboratory of the CEA Cadarache. This paper presents the scientific and operational stakes linked to fission gas issues, resumes the current state of art for analyzing them in nuclear facilities, then presents the skills gathered through this collaboration to overcome technological bottlenecks. Finally it describes the implementation strategy in nuclear research facilities of the CEA Cadarache. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-J-185: Gated CBCT Imaging for Positioning Moving Lung Tumor in Lung SBRT Treatment

Purpose: Lung stereo-tactic body radiotherapy(SBRT) treatment requires high accuracy of lung tumor positioning during treatment, which is usually accomplished by free breathing Cone-Beam computerized tomography (CBCT) scan. However, respiratory motion induced image artifacts in free breathing CBCT may degrade such positioning accuracy. The purpose of this study is to investigate the feasibility of gated CBCT imaging for lung SBRT treatment. Methods: Six Lung SBRT patients were selected for this study. The respiratory motion of the tumors ranged from 1.2cm to 3.5cm, and the gating windows for all patients were set between 35% and 65% of the respiratory phases. Each Lung SBRT patient underwent free-breathing CBCT scan using half-fan scan technique. The acquired projection images were transferred out for off-line analyses. An In-house semi-automatic algorithm was developed to trace the diaphragm movement from those projection images to acquire a patient's specific respiratory motion curve, which was used to correlate respiratory phases with each projection image. Afterwards, a filtered back-projection algorithm was utilized to reconstruct the gated CBCT images based on the projection images only within the gating window. Results: Target volumes determined by free breathing CBCT images were 71.9%±72% bigger than the volume shown in gated CBCT image. On the contrary, the target volume differences between gated CBCT and planning CT images at exhale stage were 5.8%±2.4%. The center to center distance of the targets shown in free breathing CBCT and gated CBCT images were 9.2±8.1mm. For one particular case, the superior boundary of the target was shifted 15mm between free breathing CBCT and gated CBCT. Conclusion: Gated CBCT imaging provides better representation of the moving lung tumor with less motion artifacts, and has the potential to improve the positioning accuracy in lung SBRT treatment.

60 APPLIED LIFE SCIENCES↗

Nearly degenerate two-color impulsive coherent Raman hyperspectral imaging

Impulsive stimulated Raman scattering (ISRS) is a robust technique for studying low frequency (<300 cm –1 ) Raman vibrational modes, but ISRS has faced difficulty in translation to an imaging modality. A primary challenge is the separation of the pump and probe pulses. Here we introduce and demonstrate a simple strategy for ISRS spectroscopy and hyperspectral imaging that uses complementary steep edge spectral filters to separate the probe beam detection from the pump and enables simple ISRS microscopy with a single-color ultrafast laser source. ISRS spectra are obtained that span from the fingerprint region down to <50 cm –1 vibrational modes. Furthermore, hyperspectral imaging and polarization-dependent Raman spectra are also demonstrated.

47 OTHER INSTRUMENTATION↗

Fundamental Mechanisms of Roughening and Smoothing During Thin Film Deposition

In this research program, we have explored the fundamental limits for thin film deposition in both crystalline and amorphous (i.e. non-crystalline) materials systems. For vacuum-based physical deposition processes such as sputter deposition, the background gas pressure of the inert gas (usually argon) used as the process gas has been found to be a key variable. Both a roughness transition and stress transition as a function of pressure have been linked to a common mechanism involving collisions of energetic particles from the deposition source with the process inert gas. As energetic particles collide with gas molecules in the deposition process they lose their energy rapidly if the pressure (and background gas density) is above a critical value. Both roughness and stress limit important properties of thin films for applications. In the area of epitaxial growth we have also discovered a related effect; there is a critical pressure below which highly crystalline layers grow in a layer-by-layer mode. This effect is also though to be due to energetic particle thermalization and scattering. Several other important effects such as the observation of coalescence dominated growth has been observed. This mode can be likened to the behavior of two-dimensional water droplets on the hood of a car during a rain storm; as the droplets grow and touch each other they tend to coalesce rapidly into new larger circular puddles, and this process proceeds exponentially as larger puddles overtake smaller ones and also merge with other large puddles. This discovery will enable more accurate simulations and modeling of epitaxial growth processes. We have also observed that epitaxial films undergo a roughening transition as a function of thickness, which is attributed to strain induced by the crystalline lattice mismatch with the substrate crystal. In addition, we have studied another physical deposition process called pulsed laser deposition. It differs from sputter deposition due to the pulsed nature of the deposition where particles arrive at the growth surface in an interval of a few microseconds. We have observed effects such as transient formation of two dimensional islands on elemental crystalline surfaces. Pulsed deposition may also lead to non-equilibrium phases in some cases, such as the observation anomalously high tetragonality for ferroelectric thin films. All of the results described above feature in-situ synchrotron X-ray scattering as the main experimental method, which has become an indispensable technique for observing the kinetics of structures forming in real-time. We have also investigated in-situ coherent X-ray scattering and have developed methods to characterize temporal correlations that are not possible to observe with low-coherence X-rays. A high profile result of this work is a new technique to monitor defect propagation velocities in thin films. This has practical significance since defects limit the properties of thin films and it is desirable to understand their properties and origin in order to control them for practical applications. More broadly, amorphous thin films and multilayers have applications in optical devices, including mirrors and filters. Epitaxial thin films and multilayers have applications in electronic devices such as ferroelectric multilayers for non-volatile data storage, and thermoelectric nanostructures for energy conversion. Our progress in this project points the way for improved deposition methods and for improved simulation and modeling of thin film deposition processes for nanoscale control of materials with novel applications in these areas.

36 MATERIALS SCIENCE↗

Seeing the invisible: Direct visualization of therapeutic radiation beams using air scintillation

Purpose: To assess whether air scintillation produced during standard radiation treatments can be visualized and used to monitor a beam in a nonperturbing manner. Methods: Air scintillation is caused by the excitation of nitrogen gas by ionizing radiation. This weak emission occurs predominantly in the 300–430 nm range. An electron-multiplication charge-coupled device camera, outfitted with an f/0.95 lens, was used to capture air scintillation produced by kilovoltage photon beams and megavoltage electron beams used in radiation therapy. The treatment rooms were prepared to block background light and a short-pass filter was utilized to block light above 440 nm. Results: Air scintillation from an orthovoltage unit (50 kVp, 30 mA) was visualized with a relatively short exposure time (10 s) and showed an inverse falloff (r{sup 2} = 0.89). Electron beams were also imaged. For a fixed exposure time (100 s), air scintillation was proportional to dose rate (r{sup 2} = 0.9998). As energy increased, the divergence of the electron beam decreased and the penumbra improved. By irradiating a transparent phantom, the authors also showed that Cherenkov luminescence did not interfere with the detection of air scintillation. In a final illustration of the capabilities of this new technique, the authors visualized air scintillation produced during a total skin irradiation treatment. Conclusions: Air scintillation can be measured to monitor a radiation beam in an inexpensive and nonperturbing manner. This physical phenomenon could be useful for dosimetry of therapeutic radiation beams or for online detection of gross errors during fractionated treatments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shopping For Danger: E-commerce techniques applied to collaboration in cyber security

Collaboration among cyber security analysts is essential to a successful protection strategy on the Internet today, but it is uncommonly practiced or encouraged in operating environments. Barriers to productive collaboration often include data sensitivity, time and effort to communicate, institutional policy, and protection of domain knowledge. We propose an ambient collaboration framework, Vulcan, designed to remove the barriers of time and effort and mitigate the others. Vulcan automated data collection, collaborative filtering, and asynchronous dissemination, eliminating the effort implied by explicit collaboration among peers. We instrumented two analytic applications and performed a mock analysis session to build a dataset and test the output of the system.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Kernel Machines Using Deep Learning

Building highly non-linear and non-parametric models is central to several state-of-the-art machine learning systems. Kernel methods form an important class of techniques that induce a reproducing kernel Hilbert space (RKHS) for inferring non-linear models through the construction of similarity functions from data. These methods are particularly preferred in cases where the training data sizes are limited and when prior knowledge of the data similarities is available. Despite their usefulness, they are limited by the computational complexity and their inability to support end-to-end learning with a task specific objective. On the other hand, deep neural networks have become the de facto solution for end-to-end inference in several learning paradigms. In this article, we explore the idea of using deep architectures to perform kernel machine optimization, for both computational efficiency and end-to-end inferencing. To this end, we develop the DKMO (Deep Kernel Machine Optimization) framework, that creates an ensemble of dense embeddings using Nystrõm kernel approximations and utilizes deep learning to generate task-specific representations through the fusion of the embeddings. Intuitively, the filters of the network are trained to fuse information from an ensemble of linear subspaces in the RKHS. Furthermore, we introduce the kernel dropout regularization to enable improved training convergence. Finally, we extend this framework to the multiple kernel case, by coupling a global fusion layer with pre-trained deep kernel machines for each of the constituent kernels. Using case studies with limited training data, and lack of explicit feature sources, we demonstrate the effectiveness of our framework over conventional model inferencing techniques.

97 MATHEMATICS AND COMPUTING↗

Macroporous glass monoliths prepared from powdered niobium phosphate glass by fast sintering

Macroporous monoliths were prepared by very fast sintering (between 3 and 15 min) of niobophosphate glass powders at low temperature (1018 K) using cellulose as a foaming agent. The porous materials were analyzed by thermal analysis, Raman spectroscopy, scanning electron microscopy and powder X-ray diffraction, and further investigated using X-ray microtomography, a non-destructive technique capable of reconstructing three-dimensional models of samples and providing structural measurements. The progression of the porosity of the monoliths depends on the sintering time (3 to 15 min) and the amount (up to 50% in mass) of cellulose used. The macroporous glass monoliths may find application in integrated chemical systems and in filtering processes.

36 MATERIALS SCIENCE↗

Research Applications for the Geostationary Lightning Mapper Operational Lightning Flash Data Product

The Lightning Cluster Filter Algorithm in the Geostationary Lightning Mapper (GLM) ground system identifies lightning flashes from the stream of event detections. It excels at clustering simple flashes but experiences anomalies with complex flashes that last longer than 3 s or contain more than 100 groups, leading to flashes being artificially split. In this work, we develop a technique that corrects these anomalies and apply it to the 2018 GLM data to document all lightning across the Americas. We produce statistics describing the characteristics and frequencies of reclustered GLM flashes and thunderstorm area features. The average GLM Americas flash rate in 2018 was 11.7 flashes per second with the greatest flash rate densities occurring over Lake Maracaibo (157 flashes per km 2 /year). Lloró, Chocó, Colombia had the most thunderstorm activity with 256 thunder days. The longest GLM flash spanned 673 km, the largest flash covered 114,997 km 2 , and the longest-lasting flash had a 13.496-s duration. The first case occurred over Rio Grande do Sul in Brazil, while the other two cases occurred in the central United States. All three extreme flashes are located in the stratiform regions of Mesoscale Convective Systems. The highest flash rate for a thunderstorm area feature was 17.6 flashes per second, while the largest thunderstorm was 216,865 km 2 in size. Both storms occurred in South America. In conclusion, these initial results demonstrate the value that the development of a reprocessed GLM science product would offer and how such a product might be created at a reduced computational cost.

58 GEOSCIENCES↗

Correlating the structural, chemical, and optical properties at nanometer resolution

Valence electron spectroscopic imaging (VESI) techniques, taking advantages of the energy-losses suffered by inelastic scattering of the fast electrons in the transmission electron microscope, offer an inherently high spatial resolution to characterize the electronic structure of materials close to the Fermi level. Here we demonstrate that the combination of an electron monochromator and a highly dispersive imaging energy filter, which has become available only recently, allows reliable measurements of local bandgaps on the nanometer scale. In addition, the correlations of structural, chemical, and optical properties can be revealed via VESI using monochromated electrons with a high spatial resolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Note: Electronic damping of microphonics in superconducting resonators of a continuous wave linac

The paper presents an implementation technique to damp the microphonics in superconducting resonators utilizing the coupling between the electromagnetic and the mechanical modes of a resonator. In the technique used the resonant frequency variations are fed back to modulate the field amplitude through a suitable transfer function. Of the two transfer functions used in the experiments, one emulates a derivative action and is placed in a negative feedback configuration. The other transfer function is essentially a parallel combination of second order low pass filters and is used in a positive feedback configuration. Experiments with the Quarter Wave resonators of IUAC, New Delhi linac demonstrate that the damping of some of the modes increases significantly with the introduction of this feedback leading to a reduction in power required for field stabilization and quieter operation of the RF control system.

43 PARTICLE ACCELERATORS↗

A multi-channel x-ray temporal diagnostic for measurement of time-resolved electron temperature in cryogenic deuterium–tritium implosions at OMEGA

Electron-temperature (T e ) measurements in implosions provide valuable diagnostic information, as Te is unaffected by residual flows and other non-thermal effects unlike ion temperature inferred from a fusion product spectrum. In OMEGA cryogenic implosions, measurement of T e (t) can be used to investigate effects related to time-resolved hot-spot energy balance. The proposed diagnostic utilizes five fast-rise (~15 ps) scintillator channels with distinct x-ray filtering. Furthermore, titanium and stepped aluminum filtering were chosen to maximize detector sensitivity in the 10 keV–20 keV range, as it has been shown that these x rays have similar density and temperature weighting to the emitted deuterium–tritium fusion neutrons. Initial data collected using a prototype nosecone on the existing neutron temporal diagnostic demonstrate the validity of this diagnostic technique. The proposed system will be capable of measuring spatially integrated T e (t) with 20 ps time resolution and <10% uncertainty at peak emission in cryogenic DT implosions.

47 OTHER INSTRUMENTATION↗

NEW APPROACHES TO PHOTOMETRIC REDSHIFT PREDICTION VIA GAUSSIAN PROCESS REGRESSION IN THE SLOAN DIGITAL SKY SURVEY

Expanding upon the work of Way and Srivastava we demonstrate how the use of training sets of comparable size continue to make Gaussian process regression (GPR) a competitive approach to that of neural networks and other least-squares fitting methods. This is possible via new large-size matrix inversion techniques developed for Gaussian processes (GPs) that do not require that the kernel matrix be sparse. This development, combined with a neural-network kernel function appears to give superior results for this problem. Our best-fit results for the Sloan Digital Sky Survey (SDSS) Main Galaxy Sample using u, g, r, i, z filters gives an rms error of 0.0201 while our results for the same filters in the luminous red galaxy sample yield 0.0220. We also demonstrate that there appears to be a minimum number of training-set galaxies needed to obtain the optimal fit when using our GPR rank-reduction methods. We find that morphological information included with many photometric surveys appears, for the most part, to make the photometric redshift evaluation slightly worse rather than better. This would indicate that most morphological information simply adds noise from the GP point of view in the data used herein. In addition, we show that cross-match catalog results involving combinations of the Two Micron All Sky Survey, SDSS, and Galaxy Evolution Explorer have to be evaluated in the context of the resulting cross-match magnitude and redshift distribution. Otherwise one may be misled into overly optimistic conclusions.

79 ASTRONOMY AND ASTROPHYSICS↗

Sub-10 second fly-scan nano-tomography using machine learning

Abstract X-ray computed tomography is a versatile technique for 3D structure characterization. However, conventional reconstruction algorithms require that the sample not change throughout the scan, and the timescale of sample dynamics must be longer than the data acquisition time to fulfill the stable sample requirement. Meanwhile, concerns about X-ray-induced parasite reaction and sample damage have driven research efforts to reduce beam dosage. Here, we report a machine-learning-based image processing method that can significantly reduce data acquisition time and X-ray dose, outperforming conventional approaches like Filtered-Back Projection, maximum-likelihood, and model-based maximum-a-posteriori probability. Applying machine learning, we achieve ultrafast nano-tomography with sub-10 second data acquisition time and sub-50 nm pixel resolution in a transmission X-ray microscope. We apply our algorithm to study dynamic morphology changes in a lithium-ion battery cathode under a heating rate of 50 o C min −1 , revealing crack self-healing during thermal annealing. The proposed method can be applied to various tomography modalities.

36 MATERIALS SCIENCE↗