Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fire Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Web-based Weather Expert System (WES) for Space Shuttle Launch

The Web-based Weather Expert System (WES) is a critical module of the Virtual Test Bed development to support 'go/no go' decisions for Space Shuttle operations in the Intelligent Launch and Range Operations program of NASA. The weather rules characterize certain aspects of the environment related to the launching or landing site, the time of the day or night, the pad or runway conditions, the mission durations, the runway equipment and landing type. Expert system rules are derived from weather contingency rules, which were developed over years by NASA. Backward chaining, a goal-directed inference method is adopted, because a particular consequence or goal clause is evaluated first, and then chained backward through the rules. Once a rule is satisfied or true, then that particular rule is fired and the decision is expressed. The expert system is continuously verifying the rules against the past one-hour weather conditions and the decisions are made. The normal procedure of operations requires a formal pre-launch weather briefing held on Launch minus 1 day, which is a specific weather briefing for all areas of Space Shuttle launch operations. In this paper, the Web-based Weather Expert System of the Intelligent Launch and range Operations program is presented.

Bardina, Jorge E.↗

Apollo 15 mission main parachute failure

The failure of one of the three main parachutes of the Apollo 15 spacecraft was investigated by studying malfunctions in the forward heat shield, broken riser, and firing the fuel expelled from the command module reaction control system. It is concluded that the most probable cause was the burning of raw fuel being expelled during the latter portion of depletion firing. Recommended corrective actions are included.

Source record↗

Transient Pressure Test Article (TPTA) 1.1 and 1.1A, volume 1

This final test report presents the results obtained during the static hot firing and cold-gas high Q tests of the first Transient Pressure Test Article (TPTA) 1.1. The TPTA consisted of field test joints A and B, which were the original RSRM J-insulation configuration, with a metal capture feature. It also consisted of a flight configuration nozzle-to-case test joint (Joint D) with shorter vent slots. Fluorocarbon O-rings were used in all the test joints. The purpose of the TPTA tests is to evaluate and characterize the RSMR field and nozzle-to-case joints under the influence of ignition and strut loads during liftoff anf high Q. All objectives of the cold-gas high Q (TPTA 1.1A) test were met and all measurements were close to predicted values. During the static hot-firing test (TPTA 1.1), the motor was inadvertently plugged by the quench injector plug, making it a more severe test, although no strut loads were applied. The motor was depressurized after approximately 11 min using an auxiliary system, and no anomalies were noted. In the static hot-firing test, pressure was incident on the insulation and the test joint gaps were within the predicted range. During the static hot-firing test, no strut loads were applied because the loading system malfunctioned. For this test, all measurements were within range of similar tests performed without strut loads.

Rebells, Clarence A.↗

Combustion plasma electrical conductivity model development for oxy-fuel MHD applications

Oxy-combustion can enable efficient CO2 capture from fossil fuel power plants in combined cycle systems; however, air separation is expensive. In order to directly utilize the high gas temperatures associated with oxy-combustion and offset any oxygen separation penalties, a magnetohydrodynamic (MHD) generator has been proposed as a plant topping cycle. Accurately predicting the electrical conductivity of combustion products with the addition of potassium “seed” compound is necessary to evaluate the performance of this modern approach to MHD. In order to make these predictions, improved species collisional cross-section data (momentum transfer cross-section, MTCS) are needed at relevant conditions. A gas electrical conductivity model for use in open-cycle MHD power generation applications is presented, which makes use of updated MTCS data not represented in previous legacy publications. Based on the results of a detailed review and analysis of currently available MTCS data relevant to open-cycle MHD combustion systems, recommendations have been provided for relevant species and a gas temperature range of 1500-3500 K (~0.13-0.3 eV electron energy). Model predictions utilizing updated MTCS data are validated against limited experimental data found in literature for oxy-combustion with potassium seed compound. Model results are presented from a parametric study, which show the effect of combustion conditions and seeding on ionization processes and gas electrical conductivity, highlighting differences between modern oxy-combustion MHD systems and legacy approaches implementing air-fired combustion and high levels of preheat.

20 FOSSIL-FUELED POWER PLANTS↗

Highly efficient combustion with low excess air in a modern energy-from-waste (EfW) plant

Highlights: • Operation of a commercial EfW plant with low excess air. • Uncontrolled NOx emissions are considerably reduced by lowering O{sub 2} in the combustion process. • Stable combustion control avoids CO formation even at O{sub 2} concentrations below 3 vol%. • High adiabatic combustion temperatures do not increase the amount of uncontrolled NOx. - Abstract: The effect of low excess air and high adiabatic combustion temperatures on CO and NOx formation has been investigated on a commercially operated energy-from-waste plant. With optimal combination of low O{sub 2} levels and stable combustion control, uncontrolled NOx levels could be lowered to 100–150 mg/Nm{sup 3} (dry, at 11% O{sub 2}) while keeping CO emissions at low levels. Even at adiabatic temperatures above 1400 °C thermal NOx hardly contributed to the total NOx emissions in a grate-fired EfW plant. An advanced combustion control system allowed continuous operation with very little excess air (λ < 1.2) while keeping CO and NOx at levels well below the legal emission limits.

09 BIOMASS FUELS↗

NeuroCoreX: An Open-Source FPGA-Based Spiking Neural Network Emulator with On-Chip Learning

Spiking Neural Networks (SNNs) are computational models inspired by the event-driven communication and connectivity patterns of biological neural circuits. They enable high energy efficiency and natural support for diverse architectures ranging from layered networks to small-world and graphstructured topologies. In this work, we introduce NeuroCoreX, an open-source, FPGA-based spiking neural network emulator that provides real-time, on-chip learning and flexible network organization. NeuroCoreX supports both feedforward sensory inputs streamed directly from sensors or PCs via UART and recurrent on-chip connectivity, enabling simultaneous processing and learning from external stimuli and internal network dynamics-capabilities rarely available in existing FPGA SNN platforms. The system implements a Leaky Integrate-and-Fire (LIF) neuron model with current-based synapses and supports pair-based STDP learning on both feedforward and recurrent synapses. A lightweight Python interface enables interactive configuration, live monitoring, weight read-back, and experiment control. Importantly, NeuroCoreX is tightly integrated with the SuperNeuroMAT simulator, allowing SNN models to be transferred seamlessly from software to hardware for hardware-in-the-loop development. By combining real-time plasticity, flexible connectivity, and an open-source VHDL implementation, NeuroCoreX provides an extensible and accessible platform for neuromorphic research, algorithm-hardware co-design, and energy-efficient edge intelligence.

Gautam, Ashish [ORNL]↗

Data Analytics Applied to Coal Fired Boilers for Detecting Leaks

Data analytics were used to detect boiler leaks from five different coal-fired boilers including both subcritical and supercritical systems. Discriminant functions were developed that detected leaks up to two weeks prior to forced plant shutdowns for repairs. The leaks were identified to occur at different sections of the boiler for each plant, including waterwalls, economizer and superheater using conventional process measurement data. Leaking conditions were detected with a high degree of confidence (&NestedLessLess; 1% misclassified observations) and were able to distinguish normal operations from those time periods with steam leaks even while operating the power plants in power cycling mode.Multivariable statistical analyses, including Principal Component (PCA), cluster, and Fischer Discriminant Analysis (FDA) were used to characterize the leak occurrence. Normal and operational states with steam leaks were provided in the original process datasets. These datasets were split into two different groups for training and validation purposes. The data were sorted chronologically, and every third observation was assigned to training the Discriminant Function Model (DFM) while the rest were reserved for validation. PCA was used to reduce dimensionality of the original datasets. Canonical and FDA analyses were used to investigate the relationship between process variables. The outcome of the analyses revealed that nearly 35,000 observations were classified correctly; less than 0.05% of total observations were misclassified to be leaking, i.e. both false positives and false negatives.

Indrawan, Natarianto↗

AmeriFlux US-Me2 Metolius-intermediate aged ponderosa pine

This is the AmeriFlux version of the carbon flux data for the site US-Me2 Metolius-intermediate aged ponderosa pine. Site Description - Site Description before Fire (January, 2002 - August, 2020): The mean stand age is 71 years old and the stand age of the oldest 10% of trees is about 108 years old. This site is one of the Metolius core cluster sites with different age and disturbance classes and part of the AmeriFlux network. The overstory is almost exclusively composed of ponderosa pine trees (Pinus ponderosa Doug. Ex P. Laws) with a few scattered incense cedars (Calocedrus decurrens (Torr.) Florin) and has a peak leaf area index (LAI) of 2.1 m2 m-2. Tree height is relatively homogeneous at about 18 m, and the mean tree density is approximately 339 trees ha-1 (Irvine et al., 2008). The understory is sparse with an LAI of 0.2 m2 m-2 and primarily composed of bitterbrush (Purshia tridentata (Push) DC.) and greenleaf manzanita (Arctostaphylos patula Greene). Soils at the site are sandy (69%/24%/7% sand/silt/clay at 0–0.2 m depth and 66%/27%/7% at 0.2–0.5 m depth, and 54%/ 35%/11% at 0.5–1.0 m depth), freely draining with a soil depth of approximately 1.5 m (Irvine et al., 2008; Law et al., 2001b; Schwarz et al., 2004). Green Ridge Fire: On August 20, 2020, the Green Ridge Fire burned through Us-Me2. The fire was ignited by lightning on August 16th, and grew rapidly to the east over the first few days driven by strong, downslope (westerly) afternoon winds. Fire behavior and observed fire effects were highly heterogeneous due to the localized wind pattern carrying the flaming head of the fire forward, and the efforts being made by suppression resources to contain the fire. The site experienced the full range of fire effects, from <1 m high surface fire that charred litter and duff and only consumed shrubs and herbaceous material to full tree (>15 m) crown fire that consumed 100% of needles, small limbs, and surface fuels at high intensity, leaving only ash and bare soil post-fire. Salvage Logging: From late March to late April 2021, salvage logging by the landowner occurred at the site. Almost all trees within the flux footprint were logged except a small area with lower burn severity, where sap flow and automatic soil respiration measurements are continued since the fire. In August 2022 the primary flux system was moved from the top of the damaged tall tower to a nearby shorter tower centering on the salvage/regenerating footprint.

Hanson, Chad↗

AmeriFlux FLUXNET-1F US-Me2 Metolius mature ponderosa pine

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Me2 Metolius mature ponderosa pine. This is the FLUXNET version of the carbon flux data for the site US-Me2 Metolius mature ponderosa pine produced by applying the standard ONEFlux (1F) software. Site Description - Site Description before Fire (January, 2002 - August, 2020): The mean stand age is 71 years old and the stand age of the oldest 10% of trees is about 108 years old. This site is one of the Metolius core cluster sites with different age and disturbance classes and part of the AmeriFlux network. The overstory is almost exclusively composed of ponderosa pine trees (Pinus ponderosa Doug. Ex P. Laws) with a few scattered incense cedars (Calocedrus decurrens (Torr.) Florin) and has a peak leaf area index (LAI) of 2.1 m2 m-2. Tree height is relatively homogeneous at about 18 m, and the mean tree density is approximately 339 trees ha-1 (Irvine et al., 2008). The understory is sparse with an LAI of 0.2 m2 m-2 and primarily composed of bitterbrush (Purshia tridentata (Push) DC.) and greenleaf manzanita (Arctostaphylos patula Greene). Soils at the site are sandy (69%/24%/7% sand/silt/clay at 0–0.2 m depth and 66%/27%/7% at 0.2–0.5 m depth, and 54%/ 35%/11% at 0.5–1.0 m depth), freely draining with a soil depth of approximately 1.5 m (Irvine et al., 2008; Law et al., 2001b; Schwarz et al., 2004). Green Ridge Fire: On August 20, 2020, the Green Ridge Fire burned through Us-Me2. The fire was ignited by lightning on August 16th, and grew rapidly to the east over the first few days driven by strong, downslope (westerly) afternoon winds. Fire behavior and observed fire effects were highly heterogeneous due to the localized wind pattern carrying the flaming head of the fire forward, and the efforts being made by suppression resources to contain the fire. The site experienced the full range of fire effects, from <1 m high surface fire that charred litter and duff and only consumed shrubs and herbaceous material to full tree (>15 m) crown fire that consumed 100% of needles, small limbs, and surface fuels at high intensity, leaving only ash and bare soil post-fire. Salvage Logging: From late March to late April 2021, salvage logging by the landowner occurred at the site. Almost all trees within the flux footprint were logged except a small area with lower burn severity, where sap flow and automatic soil respiration measurements are continued since the fire. In August 2022 the primary flux system was moved from the top of the damaged tall tower to a nearby shorter tower centering on the salvage/regenerating footprint.

Hanson, Chad↗

Technoeconomic Evaluation of MEA versus Mixed Amines for CO 2 Removal at Near-Commercial Scale at Duke Energy Gibson 3 Plant

Carbon emissions in the power sector remains an important goal for both US and Chinese decision makers and industrial leaders. In order to deeply reduce their greenhouse gas emissions, many utilities are considering carbon capture, utilization, and sequestration (CCUS). For the existing US and Chinese coal-burning fleets, post-combustion capture (PCC) is the only viable approach. While companies provide technology for PCC retrofits, typically solvent-based absorption systems involving amine solutions, the costs and performance of these systems remain largely untested in commercial settings. As such power generation companies have very few technical or economic data sets on which to base large capital decisions. In support of gaining this information, the world’s largest power company, Huaneng Power Group, has developed and deployed several PCC systems as retrofits to Chinese coal-fired power plants. Duke Energy Inc., North America’s largest power generator, is considering options for CCUS retrofits and has created a partnership with Huaneng to assess the viability of a retrofit project on one of its US plants. In support of this effort, and in partnership with Duke and Huaneng under the US-China Clean Energy Research Program (CERC), LLNL has evaluated the economics of a novel amine-solvent technology for removal of CO 2 from flue gas developed by Huaneng’s Clean Energy Research Institute (Huaneng CERI). This technology is being considered for implementation by Duke Energy at their Gibson-3 unit in Indiana.

01 COAL, LIGNITE, AND PEAT↗

Integrated science building

Shell space fit out included faculty office advising space, student study space, staff restroom and lobby cafe. Electrical, HVAC and fire alarm installations and upgrades to existing systems were required to support the newly configured spaces. These installations and upgrades included audio/visual equipment, additional electrical outlets and connections to emergency generators. The project provided increased chilled water capacity with the addition of an electric centrifugal chiller. Upgrades associated with chiller included upgrade of exhaust ventilation fan, electrical conductor and breaker upgrades, piping and upgrades to air handling equipment.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Probabilistic Topography Project Update 5/20 [Slides]

Problem/Goal: Earth System Models (ESMs) do not accurately predict fire spread. There are no effects from topography/vegetation heterogeneity below the model’s scale (100-200km). Use physics based models (FIRETEC and QUICFIRE) to produce an archive of correction factors for SPITFIRE (chosen ESM). This project will: Use datasets to create PDFs of slope & aspect, vegetation distribution; Create joint distribution and sample to make new domain; Run FIRETEC & QUICFIRE on created domain, record output (area burned, intensity, etc.); and Use output to create PDF of correction factors for SPITFIRE runs.

58 GEOSCIENCES↗

Success Path Method: Conformance with Safety Management Systems

All industrial facilities deal with safety hazards such as equipment failures, chemical and toxic releases, and fires and explosions just to name a few. A disciplined framework for managing the integrity of operating systems and processes that handle hazardous substances by applying good design principles, engineering, and operating practices is called process safety. The goal of such framewoks is to prevent the release of energy or material that could cause harm to people or damage to equipment and/or environment. Process safety covers all aspects of facility operation also including design, maintenance, and human and organizational factors that could possibly have effect on process safety. As it will be seen from the discussion below, process safety is just one of the pieces of the much bigger matter, a safety culture. Many industries have long recognized the importance of safety culture in their day-to-day operation. Although the definition of safety culture can slightly differ from organization to organization, in general, a safety culture is how things are done to demonstrate a commitment to safety by everyone involved. An organization acquires safety culture over time as the product of individual and group values, actions, and behaviors toward overall safety. It is important to note that safety culture should not be viewed as some static state that an organization wants to reach. It is more like a constantly evolving level of “how things are done when nobody is watching.” Safety culture is an inherent characteristic of an organization, it is always present, but the level can range on a continuum from undesirable to desirable or more commonly used, from negative to positive. An example for an undesirable, negative safety culture would be a company in which accidents resulting in harm (physical and/or emotional) of its employees, equipment or surrounding environment and community occur frequently. At the other end of the spectrum would be a company in which such accidents are rare or do not occur at all (desired or positive safety culture). Every company/industry exists somewhere within this spectrum.

42 ENGINEERING↗

Demonstration of Mer-Cure Technology for Enhanced Mercury Control

Alstom Power Inc. has completed a DOE/NETL-sponsored program (under DOE Cooperative Agreement No. De-FC26-07NT42776) to demonstrate Mer-Cure{trademark}, one of Alstom's mercury control technologies for coal-fired boilers. The Mer-Cure{trademark}system utilizes a small amount of Mer-Clean{trademark} sorbent that is injected into the flue gas stream for oxidation and adsorption of gaseous mercury. Mer-Clean{trademark} sorbents are carbon-based and prepared with chemical additives that promote oxidation and capture of mercury. The Mer-Cure{trademark} system is unique in that the sorbent is injected into an environment where the mercury capture kinetics is accelerated. The full-scale demonstration program originally included test campaigns at two host sites: LCRA's 480-MW{sub e} Fayette Unit No.3 and Reliant Energy's 190-MW{sub e} Shawville Unit No.3. The only demonstration tests actually done were the short-term tests at LCRA due to budget constraints. This report gives a summary of the demonstration testing at Fayette Unit No.3. The goals for this Mercury Round 3 program, established by DOE/NETL under the original solicitation, were to reduce the uncontrolled mercury emissions by 90% at a cost significantly less than 50% of the previous target of $60,000/lb mercury removed. The results indicated that Mer-Cure{trademark} technology could achieve mercury removal of 90% based on uncontrolled stack emissions. The estimated costs for 90% mercury control, at a sorbent cost of $0.75 to $2.00/lb respectively, were $13,400 to $18,700/lb Hg removed. In summary, the results from demonstration testing show that the goals established by DOE/NETL were met during this test program. The goal of 90% mercury reduction was achieved. Estimated mercury removal costs were 69-78% lower than the benchmark of $60,000/lb mercury removed, significantly less than 50% of the baseline removal cost.

01 COAL, LIGNITE, AND PEAT↗

Plasma-fluidic hybrid display

Fluidic logic elements to control firing and extinction of plasma matrix display system cells with constant electrical power supply

Hilborn, E. H.↗

X-ray reflection efficiency of nickel-coated quartz optical flats

The reflection efficiency of quartz optical flats vacuum coated with 1000-A nickel was evaluated. Of the three vacuum coated samples tested, two had been contaminated during the firing of the Lunar Module Reaction Control System in the vacuum chamber. Measurements were made for 1.54-, 1.79-, and 2.29-A incident radiation. The reflection efficiency of the contaminated samples was reduced by as much as 50 percent for some angles of incidence.

Reynolds, J. M.↗