Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION PROBES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Use of particle beams for lunar prospecting

A key issue in choosing the appropriate site for a manned lunar base is the availability of resources, particularly oxygen and hydrogen for the production of water, and ores for the production of fuels and building materials. NASA has proposed two Lunar Scout missions that would orbit the Moon and use, among other instruments, a hard X-ray spectrometer, a neutron spectrometer, and a Ge gamma ray spectrometer to map the lunar surface. This passive instrumentation will have low resolution (tens of kilometers) due to the low signal levels produced by natural radioactivity and the interaction of cosmic rays and the solar wind with the lunar surface. This paper presents the results of a concept definition effort for a neutral particle beam lunar mapper probe. The idea of using particle beam probes to survey asteroids was first proposed by Sagdeev et al., and an ion beam device was fielded on the 1988 Soviet probe to the Mars moon Phobos. During the past five years, significant advances in the technology of neutral particle beams (NPB) have led to a suborbital flight of a neutral hydrogen beam device in the SDIO-sponsored BEAR experiment. An orbital experiment, the Neutral Particle Beam Far Field Optics Experiment (NPB-FOX) is presently in the preliminary design phase. The development of NPB accelerators that are space-operable leads one to consider the utility of these devices for probing the surface of the Moon using gamma ray, X-ray, and optical/UV spectroscopy to locate various elements and compounds. We consider the utility of the NPB-FOX satellite containing a 5-MeV particle beam accelerator as a probe in lunar orbit. Irradiation of the lunar surface by the particle beam will induce secondary and back scattered radiation from the lunar surface to be detected by a sensor that may be co-orbital with or on the particle beam satellite platform, or may be in a separate orbit. The secondary radiation is characteristic of the make-up of the lunar surface. The size of the spot irradiated by the beam is less than 1 km wide along the ground track of the satellite, resulting in the potential for high resolution. The fact that the probe could be placed in polar orbit would result in global coverage of the lunar surface. The orbital particle beam probe could provide the basis for selection of sites for more detailed prospecting by surface rovers.

Toepfer, A. J.↗

Intercalation-Induced Reversible Electrochromic Behavior of Two-Dimensional Ti 3 C 2 T x MXene in Organic Electrolytes

MXenes, a large family of two-dimensional materials, have attracted tremendous attention due to their unique physical and chemical properties. Reversible ion intercalation between MXene layers allows modification of the optical, thermal, magnetic, and chemical properties. The electrochemical charge/discharge of MXenes in aqueous electrolytes was reported to lead to reversible electrochromic behavior. In this work, the electrochromic effect of semitransparent Ti 3 C 2 T x MXene film was probed by electrochemical intercalation of Li ions. Correspondingly, a peak shift of 100 nm was observed in the UV-vis spectrum. By combining in-situ Raman spectroscopy, in-situ X-ray diffraction, and density functional theory calculations, we show that the electrochromic shift is primarily due to the formation of robust O-Li bonds and the emerging bands induced changes of inter-band excitations. Finally, understanding the mechanism of electrochromic behavior in Ti 3 C 2 T x lays the foundations of designating 2D materials with durable, controllable, and efficient intercalation-induced electrochromic behaviors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Solution Structure and Hydration Forces between Mica and Hydrophilic Versus Hydrophobic Surfaces

Solid-liquid interfaces are central to a range of interesting phenomena including catalysis, heterogeneous nucleation, water desalination, and biomolecular assembly. While three-dimensional Fast Force Mapping (3D FFM) has emerged as a technique for resolving interfacial solution structure at the molecular scale, key challenges for data interpretation persist, most notably regarding the influence of the probe on the measured structure. Using the mica-water system as a case study, we investigate the effect of hydrophilic and hydrophobic probes on interfacial solution structure measured by 3D FFM. Data from hydrophilic silicon-based probes are in good agreement with molecular dynamics simulations, wherein the innermost water molecules adsorb preferentially at the surface ditrigonal cavity sites followed by two subsequent hydration layers. In contrast, the hydrophobic carbon-based probes detect vertical oscillatory features, but do not show lateral patterning that matches the underlying mica lattice. At high ionic strength, up to six of these oscillatory features are observed extending 2 nm into the solution phase with an average spacing of 0.29 ± (0.04) nm. Further, we also determine that the repulsive hydration force between mica and the hydrophilic probe depends on the nature and concentration of ions in solution. Specifically, solutions with stronger ion-water and ion-ion interactions increase the interfacial viscosity, which results in a stronger repulsive hydration force as the probe approaches the surface. Based on these observations, we present a scheme for controlling the outcomes of particle attachment and aggregation by varying the solution conditions to tune the hydration force.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The ion polytropic coefficient in a collisionless sheath containing hot ions

The fluid approach has been widely used to study plasma sheath dynamics. For a sheath containing hot ions whose temperature is greater than the electron's, how to truncate the fluid hierarchy chain equations while retaining to the fullest extent of the kinetic effects is always a difficult problem. In this paper, a one-dimensional, collisionless sheath containing hot ions is studied via particle-in-cell simulations. By analyzing the ion energy equation and taking the kinetic effects into account, we have shown that the ion polytropic coefficient in the vicinity of the sheath edge is approximately constant so that the state equation with the modified polytropic coefficient can be used to close the hierarchy chain of the ion fluid equations. The value of the polytropic coefficient strongly depends on the hot ion temperature and its concentration in the plasma. The semi-analytical model is given to interpret the simulation results. As an application, the kinetic effects on the ion saturation current density in the probe theory are discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Picosecond excite-and-probe absorption measurement of the 4T2 state nonradiative lifetime in ruby

In a picosecond excite-and-probe absorption measurement, a 527-nm picosecond pulse excites the 4T2 state of the Cr(3+) ion in ruby and a 3.4-micron picosecond probe pulse monitors the growth and decay of population in the 2E state as a function of pump-probe delay. From the growth of population in the metastable 2E state, an upper limit of 7 ps for the nonradiative lifetime of the 4T2 state is determined.

Gayen, S. K.↗

Coupling effect of electron cyclotron resonance hydrogen plasma and dc biasing in fabricating diamond nanotips

The electron cyclotron resonance (ECR) hydrogen plasma with substrate dc biasing was investigated by using a Langmuir probe and optical emission spectroscopy during the formation of nanotips from as-grown diamond films. It is found that the coupling effect between the substrate biasing and the bulk plasma plays an important role in the fluxes of active species incident on the substrate. The energy of incident hydrogen ions is determined by the substrate biasing, while the densities of incident hydrogen ions and atoms are adjusted jointly by the substrate biasing and the bulk plasma. Diamond nanotips were fabricated from as-grown films under ECR-dc conditions. The shapes and sizes of the nanotips vary with the processing parameters, which are correlated with the change of active species on the film surface due to the coupling effect.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Investigating the role of hydrogen in silicon deposition using an energy-resolved mass spectrometer and a Langmuir probe in an Ar/H{sub 2} radio frequency magnetron discharge

The plasma parameters and ion energy distributions (IED) of the dominant species in an Ar-H{sub 2} discharge are investigated with an energy resolved mass spectrometer and a Langmuir probe. The plasmas are generated in a conventional magnetron chamber powered at 150 W, 13.56 MHz at hydrogen flow rates ranging from 0 to 25 sccm with a fixed argon gas flow rate of 15 sccm. Various H{sub n}{sup +}, SiH{sub n}{sup +}, SiH{sub n} fragments (with n = 1, 2, 3) together with Ar{sup +} and ArH{sup +} species are detected in the discharge. The most important species for the film deposition is SiH{sub n} (with n = 0, 1, 2). H fragments affect the hydrogen content in the material. The flux of Ar{sup +} decreases and the flux of ArH{sup +} increases when the hydrogen flow rate is increased; however, both fluxes saturate at hydrogen flow rates above 15 sccm. Electron density, n{sub e}, electron energy, T{sub e}, and ion density, n{sub i}, are estimated from the Langmuir probe data. T{sub e} is below 1.2 eV at hydrogen flow rates below 8 sccm, and about 2 eV at flow rates above 8 sccm. n{sub e} and n{sub i} decrease with increased hydrogen flow but the ratio of n{sub i} to n{sub e} increases. The formation of H{sup +} ions with energies above 36 eV and electrons with energies greater than 2 eV contributes to the decrease in hydrogen content at hydrogen flow rates above 8 sccm. Analysis of the IEDs indicates an inter-dependence of the species and their contribution to the thin film growth and properties.

36 MATERIALS SCIENCE↗

Suppression of transient enhanced diffusion in sub-micron patterned silicon template by dislocation loops formation

We investigate the evolution of two dimensional transient enhanced diffusion (TED) of phosphorus in sub-micron scale patterned silicon template. Samples doped with low dose phosphorus with and without high dose silicon self-implantation, were annealed for various durations. Dopant diffusion is probed with plane-view scanning capacitance microscopy. The measurement revealed two phases of TED. Significant suppression in the second phase TED is observed for samples with high dose self-implantation. Transmission electron microscopy suggests the suppressed TED is related to the evolution of end of range defect formed around ion implantation sidewalls.

36 MATERIALS SCIENCE↗

Open Heavy Flavor Production at Forward Angles in PHENIX

Measurement of the production of heavy quarks in heavy ion collisions can be used to probe the early stages of the created medium, study hot and cold nuclear matter effects, and test theoretical predictions concerning quark energy loss and initial-state effects. This is a current area of active research in the field and it is important to extend such measurements to the forward region. PHENIX can measure the production of open heavy flavor at forward angles with subsequent semi-leptonic decay of heavy flavor mesons into muons. We report the nuclear modification factor for the production of muon from heavy flavor decay in Cu+Cu collisions at s_NN = 200 GeV for three centrality intervals and compare to theoretical predictions concerning the suppression of heavy quark production which incorporate heavy quark energy loss and in-medium heavy meson disassociation. Additionally, we report the charm production cross section for p+p collisions at s = 200 GeV and compare results to Fixed Order plus Next-to-Leading Log predictions Research sponsored by the Office of Nuclear Physics, U.S. Department of Energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Electromagnetic and strange probes of dense nuclear matter at NICA/MPD: a feasibility study

The main task of the NICA/MPD physics program is a study of the properties of nuclear matter under extreme conditions achieved in collisions of heavy ions. These properties can reveal themselves through different probes, the most promising among those being the lepton-antilepton pairs and strange hadrons. In this paper the MPD performance for measuring the electron-positron pairs and strange particles (Λ, Ξ{sup –} and Ω{sup –} hyperons and their antiparticles Λ̄, Ξ̄{sup +} and Ω̄{sup +} as well as hypernuclei {sub 3}{sup Λ}Λ) in central Au + Au collisions at NICA energies is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laser-induced fluorescence measurements of ion fluctuations in electron and ion presheaths

Electrostatic flow-driven instabilities have been predicted in the presheath region of low-temperature plasmas for both ion and electron rich sheaths. The ion-acoustic fluctuations that arise from these instabilities can influence transport through an enhanced collision rate. In this work, ion fluctuation spectra were measured using laser-induced fluorescence (LIF) in the presheath region for both sheath polarities. Furthermore, the non-invasive nature of LIF compared to that of probes is particularly valuable for these measurements because the sheath and presheath around a probe may generate their own flow-driven instabilities, which obscure the measurement. Measurements were made using a recently implemented field programmable gate array-based system able to measure ion fluctuation spectra up to 1 MHz using a two-point correlation function technique. Narrow bandwidth ion fluctuations were observed near 0:46 f pi (460 kHz) for both sheath polarities, where f pi is the ion plasma frequency. The observed fluctuations were significantly stronger in the electron sheath case and were observed over a larger volume of plasma. Fluctuations were measured in the ion sheath case at locations far enough from the sheath that linear theory predicts stability, suggesting that ion-acoustic instabilities generated in the relatively small unstable region near the boundary reflect from the sheath and perturb a much larger volume of the plasma. This is expected to affect probes with both ion and electron rich sheaths, meaning any dc biased probe may effectively act as an ion-acoustic wave antenna. These measurements are consistent with the recent theory and particle-in-cell results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photonuclear tomography in ultraperipheral heavy-ion collisions

We present a theoretical investigation of photonuclear tomography as a novel technique for probing the internal structure of nuclei. In this approach, ultraperipheral heavy-ion collisions (UPCs) serve as a source of intense fluxes of virtual photons, which induce coherent production of vector mesons. By analyzing the probabilities and cross sections of these photon-induced processes, we propose a methodology for reconstructing the spatial distribution of nucleons within the nucleus. Our framework provides a systematic way to access information on the nuclear geometry probed in UPCs, offering new opportunities for studies of nuclear structure using particle production as a probe. Numerical calculations for selected examples illustrate the feasibility and potential of this method.

particle & resonance production↗

Response-time improved hydrothermal-method-grown ZnO scintillator for soft x-ray free-electron laser timing-observation

For pump and probe experiments in x-ray free-electron laser (XFEL) facilities, accurate timing synchronization between short-wavelength femtosecond pulses from XFELs and short optical pulses from other light sources is required. For this purpose, the response time of a hydrothermal-method-grown ZnO is improved by over one order of magnitude via intentional iron ion doping. The fluorescence rise- and decay-time constants are measured to be less than 10 and 100 ps, respectively. Owing to its intense fluorescence even for single pulse XFEL excitation, the timing jitter of the soft x-ray pulse and timing electronics are evaluated to be less than 70 ps.

43 PARTICLE ACCELERATORS↗

Control of ion density distribution by magnetic traps for plasma electrons

The effect of a magnetic field of two magnetic coils on the ion current density distribution in the setup for low-temperature plasma deposition is investigated. The substrate of 400 mm diameter is placed at a distance of 325 mm from the plasma duct exit, with the two magnetic coils mounted symmetrically under the substrate at a distance of 140 mm relative to the substrate centre. A planar probe is used to measure the ion current density distribution along the plasma flux cross-sections at distances of 150, 230, and 325 mm from the plasma duct exit. It is shown that the magnetic field strongly affects the ion current density distribution. Transparent plastic films are used to investigate qualitatively the ion density distribution profiles and the effect of the magnetic field. A theoretical model is developed to describe the interaction of the ion fluxes with the negative space charge regions associated with the magnetic trapping of the plasma electrons. Theoretical results are compared with the experimental measurements, and a reasonable agreement is demonstrated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ION TRAP STUDIES OF H{sup -} + H {yields} H{sub 2} + e{sup -} BETWEEN 10 AND 135 K

Thermal rate coefficients for forming H{sub 2} via associative detachment in H{sup -} + H collisions were determined using the combination of a 22-pole ion trap (22PT) with a skimmed effusive beam of atomic hydrogen penetrating the ion cloud. The temperature of both reactants have been varied independently (ion trap: T{sub 22PT} = 10-150 K, neutral beam accommodator T{sub ACC} = 10, 50, 120 K). Using various combinations, the temperature range between 10 and 135 K has been accessed for the first time experimentally. The effective number density of H (typically some 10{sup 8} cm{sup -3}) is determined in situ via chemical probing with CO{sup +}{sub 2} ions. With decreasing temperature, the measured thermal rate coefficients decrease slowly from 5.5 Multiplication-Sign 10{sup -9} cm{sup 3} s{sup -1} at 135 K to 4.1 Multiplication-Sign 10{sup -9} cm{sup 3} s{sup -1} at 10 K. The relative error is 10%, while the absolute values may deviate systematically by up to 40%, due to uncertainties in the calibration reaction. Significant improvements of the versatile and sensitive experiment are possible, e.g., by using electron transfer from H to D{sup +} as calibration standard.

79 ASTRONOMY AND ASTROPHYSICS↗

In-situ observation of inhomogeneous degradation in large format Li-ion cells by neutron diffraction

This work presents a non-destructive in-situ method for probing degradation mechanisms in large format, operating, commercial lithium-ion batteries by neutron diffraction. A fresh battery (15 Ah capacity) was shown to have a uniform (homogeneous) local state of charge (SOC) at 4.0 V (9 Ah SOC) and 4.2 V (15 Ah SOC), with 1.33 C and 2.67 C charging rates, respectively. This battery was then aggressively cycled until it retained only a 9 Ah capacity, 60% of its original value. Inhomogeneous deterioration in the battery was observed: near the edges, both the graphite anode and the spinel-based cathode showed a significant loss of capacity, while near the central area, both electrodes functioned properly. An SOC mapping measurement of the degraded battery in the fully charged state (4.2 V) indicated that the loss of local capacity of the anode and cathode is coupled.

25 ENERGY STORAGE↗

Operating a radio-frequency plasma source on water vapor

A magnetically enhanced radio-frequency (rf) plasma source operating on water vapor has an extensive list of potential applications. In this work, the use of a rf plasma source to dissociate water vapor for hydrogen production is investigated. This paper describes a rf plasma source operated on water vapor and characterizes its plasma properties using a Langmuir probe, a residual gas analyzer, and a spectrometer. The plasma source operated first on argon and then on water vapor at operating pressures just over 300 mtorr. Argon and water vapor plasma number densities differ significantly. In the electropositive argon plasma, quasineutrality requires n{sub i}{approx_equal}n{sub e}, where n{sub i} is the positive ion density. But in the electronegative water plasma, quasineutrality requires n{sub i+}=n{sub i-}+n{sub e}. The positive ion density and electron density of the water vapor plasma are approximately one and two orders of magnitude lower, respectively, than those of argon plasma. These results suggest that attachment and dissociative attachment are present in electronegative water vapor plasma. The electron temperature for this water vapor plasma source is between 1.5 and 4 eV. Without an applied axial magnetic field, hydrogen production increases linearly with rf power. With an axial magnetic field, hydrogen production jumps to a maximum value at 500 W and then saturates with rf power. The presence of the applied axial magnetic field is therefore shown to enhance hydrogen production.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new emissive-probe method for electron temperature measurement in radio-frequency plasmas

A new method to measure electron temperature by an emissive probe has been proposed. The method is based on measurement of the functional relationship between the floating potential and the heating voltage of emissive probe. From the measured data of the floating potential change as a function of the heating voltage, the electron temperature could be determined by comparing with the theoretical curve obtained under the assumption of Maxwellian distribution. The overall characteristic of the floating potential change could be explained as a function of the heating voltage. The electron temperatures obtained by the present method were consistent with those measured by the rf-compensated Langmuir probe within the error. These experimental verifications were made in the electron density range of 2.6x10{sup 11}-2.8x10{sup 12} cm{sup -3}. It was stressed that the present method is advantageous in that the probe is operated in a floating condition, hence applicable to plasmas produced in an insulated container.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗