Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image processing.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Imaging techniques in X-ray astronomy.

Some of the imaging problems encountered in space-borne X-ray astronomy are reviewed, along with the techniques considered for their solution. Following a discussion of X-ray focussing and X-ray image processing, the development of X-ray imaging devices is surveyed. It is shown that the imaging devices that will be used in X-ray astronomy will take advantage of developments intended for infrared and optical astronomy. The special requirements of X-ray observation - especially, single photon detection and high time resolution - rule out the use of existing devices, particularly because of readout problems.

Gursky, H.↗

Study of spin-scan imaging for outer planets missions

The constraints that are imposed on the Outer Planet Missions (OPM) imager design are of critical importance. Imager system modeling analyses define important parameters and systematic means for trade-offs applied to specific Jupiter orbiter missions. Possible image sequence plans for Jupiter missions are discussed in detail. Considered is a series of orbits that allow repeated near encounters with three of the Jovian satellites. The data handling involved in the image processing is discussed, and it is shown that only minimal processing is required for the majority of images for a Jupiter orbiter mission.

Russell, E. E.↗

Computer-aided analysis of CCD linear image sensors

Special test equipment and techniques to collect and process image information from charge coupled devices (CCDs) by digital computer were reviewed. The video channel was traced from the CCD to the direct memory access bus of the Interdata Computer. Software was developed to evaluate and characterize a CCD for (1) dark signal versus temperature relationship, (2) calculation of temporal noise magnitude and noise shape for each pixel, (3) spatial noise into the video chain due to dark signal, (4) response versus illumination relationship (gamma), (5) response versus wavelength of illumination (spectral), (6) optimization of forcing functions, and (7) evaluation of an image viewed by a CCD. The basic software differences and specific examples of each program operating on real data are presented.

Prince, S. S.↗

Air Force research in optical processing

Optical and optical electronic hybrid processing especially in the application area of image processing are emphasized. Real time pattern recognition processors for such airborne missions as target recognition, tracking, and terminal guidance are studied.

Neff, J.↗

The new near-infrared array camera at the University of Rochester

A near-infrared array camera system has been constructed for use in the 1-5 micron region. The camera is based on a 32 x 32 element InSb focal plane array. The performance of most of the individual detectors in the system is found to be comparable to or better than the performance of any single-element InSb detector system currently in use. A thorough description of the camera system and its image processing subsystems is given, and some sample images are provided.

Forrest, W. J.↗

Systems integration for the Kennedy Space Center (KSC) Robotics Applications Development Laboratory (RADL)

A laboratory for developing robotics technology for hazardous and repetitive Shuttle and payload processing activities is discussed. An overview of the computer hardware and software responsible for integrating the laboratory systems is given. The center's anthropomorphic robot is placed on a track allowing it to be moved to different stations. Various aspects of the laboratory equipment are described, including industrial robot arm control, smart systems integration, the supervisory computer, programmable process controller, real-time tracking controller, image processing hardware, and control display graphics. Topics of research include: automated loading and unloading of hypergolics for space vehicles and payloads; the use of mobile robotics for security, fire fighting, and hazardous spill operations; nondestructive testing for SRB joint and seal verification; Shuttle Orbiter radiator damage inspection; and Orbiter contour measurements. The possibility of expanding the laboratory in the future is examined.

Davis, V. Leon↗

Raster Metafile and Raster Metafile Translator

The intent is to present an effort undertaken at NASA Langley Research Center to design a generic raster image format and to develop tools for processing images prepared in this format. Both the Raster Metafile (RM) format and the Raster Metafile Translator (RMT) are addressed. This document is intended to serve a varied audience including: users wishing to display and manipulate raster image data, programmers responsible for either interfacing the RM format with other raster formats or for developing new RMT device drivers, and programmers charged with installing the software on a host platform.

Taylor, Nancy L.↗

Starling Formation-Flying Optical Experiment: Initial Operations and Flight Results

This paper presents initial flight results for angles-only navigation of a swarm of small spacecraft, conducted during the Starling Formation-Flying Optical Experiment (StarFOX). StarFOX is one of four experiments aboard the NASA Starling mission, which consists of four CubeSats launched in July 2023. Angles-only methods apply inter-satellite bearing angles obtained by on-board cameras for navigation, increasing satellite autonomy and enabling new mission concepts. Nevertheless, prior flight demonstrations have only featured one observer and target and have relied upon a-priori target orbit knowledge for initialization, translational maneuvers to resolve target range, and external absolute orbit updates to maintain convergence. StarFOX overcomes these limitations by applying the angles-only Absolute and Relative Trajectory Measurement System (ARTMS), which integrates three novel algorithms. Image Processing detects and tracks multiple targets in images, using multi-hypothesis methods and domain-specific kinematic modeling, and computes target bearing angles. Batch Orbit Determination computes initial swarm orbit estimates from bearing angle batches, via iterative batch least squares and sampling of the weakly observable target range. Sequential Orbit Determination leverages an adaptive, efficient unscented Kalman filter with nonlinear models to refine swarm state estimates over time. Multi-observer measurements shared over an intersatellite link are seamlessly fused to enable robust absolute and relative orbit determination. Initial StarFOX experiments are the first demonstrations of autonomous angles-only navigation for a satellite swarm, including multi-target and multi-observer relative navigation; autonomous initialization of navigation for unknown targets; and simultaneous absolute and relative orbit determination. Relative navigation accuracy of 1% (single observer) and 0.2% (multi-observer) of the inter-satellite range is achieved under challenging measurement conditions. Results demonstrate promising performance with regards to ongoing StarFOX campaigns and the application of angles-only navigation to future distributed missions.

Relative Navigation↗

Method and system for the diagnosis of disease using retinal image content and an archive of diagnosed human patient data

A method for diagnosing diseases having retinal manifestations including retinal pathologies includes the steps of providing a CBIR system including an archive of stored digital retinal photography images and diagnosed patient data corresponding to the retinal photography images, the stored images each indexed in a CBIR database using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the stored images. A query image of the retina of a patient is obtained. Using image processing, regions or structures in the query image are identified. The regions or structures are then described using the plurality of feature vectors. At least one relevant stored image from the archive based on similarity to the regions or structures is retrieved, and an eye disease or a disease having retinal manifestations in the patient is diagnosed based on the diagnosed patient data associated with the relevant stored image(s).

Tobin, Jr., Kenneth William↗

Method and system for the diagnosis of disease using retinal image content and an archive of diagnosed human patient data

A method for diagnosing diseases having retinal manifestations including retinal pathologies includes the steps of providing a CBIR system including an archive of stored digital retinal photography images and diagnosed patient data corresponding to the retinal photography images, the stored images each indexed in a CBIR database using a plurality of feature vectors, the feature vectors corresponding to distinct descriptive characteristics of the stored images. A query image of the retina of a patient is obtained. Using image processing, regions or structures in the query image are identified. The regions or structures are then described using the plurality of feature vectors. At least one relevant stored image from the archive based on similarity to the regions or structures is retrieved, and an eye disease or a disease having retinal manifestations in the patient is diagnosed based on the diagnosed patient data associated with the relevant stored image(s).

59 BASIC BIOLOGICAL SCIENCES↗

Automatic tool alignment in a backscatter x-ray scanning system

Technologies pertaining to backscatter x-ray scanning systems are described herein. The backscatter x-ray scanning system includes an x-ray source, which directs collimated x-rays along a plurality of output vectors towards a target. A detector detects diffusely reflected x-rays subsequent to respective collimated x-rays impacting the target, and outputs signals indicative of parameters of the detected x-rays. An image processing system generates an x-ray image based upon parameters of the detected x-rays, wherein each pixel in the image corresponds to a respective output vector. A user selects a particular portion of the image, and a tool is positioned such that its directional axis is coincident with the output vector corresponding to at least one pixel in the portion of the image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Automatic tool alignment in a backscatter X-ray scanning system

Technologies pertaining to backscatter x-ray scanning systems are described herein. The backscatter x-ray scanning system includes an x-ray source, which directs collimated x-rays along a plurality of output vectors towards a target. A detector detects diffusely reflected x-rays subsequent to respective collimated x-rays impacting the target, and outputs signals indicative of parameters of the detected x-rays. An image processing system generates an x-ray image based upon parameters of the detected x-rays, wherein each pixel in the image corresponds to a respective output vector. A user selects a particular portion of the image, and a medical device is positioned such that its directional axis is coincident with the output vector corresponding to at least one pixel in the portion of the image.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First Steps Toward Incorporating Image Based Diagnostics Into Particle Accelerator Control Systems Using Convolutional Neural Networks

At present, a variety of image-based diagnostics are used in particle accelerator systems. Often times, these are viewed by a human operator who then makes appropriate adjustments to the machine. Given recent advances in using convolutional neural networks (CNNs) for image processing, it should be possible to use image diagnostics directly in control routines (NN-based or otherwise). This is especially appealing for non-intercepting diagnostics that could run continuously during beam operation. Here, we show results of a first step toward implementing such a controller: our trained CNN can predict multiple simulated downstream beam parameters at the Fermilab Accelerator Science and Technology (FAST) facility's low energy beamline using simulated virtual cathode laser images, gun phases, and solenoid strengths.

43 PARTICLE ACCELERATORS↗

Thermo-mechanical processing window for β phase recrystallization inTi-5Al-5Mo-5V-3Cr alloy

Highlights: • A processing window has been developed to obtain fine uniform recrystallized grains. • High deformation (90%) with annealing at intermediate temperature (950 °C) suggested • Dynamic recrystallization (Drx) should be avoided. • DRx reduces driving force for static rx. It gives bimodal distribution of grains. • Final deformation step should be in the α + β phase field. Ti-5Al-5Mo-5V-3Cr (Ti-5553) is a high strength β titanium alloy. It is now commonly used in thick section aerospace components. In general, the thermo-mechanical processing (TMP) of β titanium alloys done at high temperature to obtain uniformly recrystallized fine grain structure is one of the major challenges. Through this work, a TMP window for Ti-5553 (through systematic variation in % reduction and post deformation annealing temperature) has been developed to obtain fine uniformly recrystallized β grains. Grain size has been quantified on EBSD generated orientation maps, by applying stereological methods, image processing and automated reconstruction. Effects of % deformation and post deformation annealing temperature, as well as that of initial ingot size prior to deformation and the capacity of the forge on the static and dynamic recrystallization behavior, which eventually determine the final grain size distribution, have been illustrated.

36 MATERIALS SCIENCE↗

Applications of photogrammetry to structural assessment

Photogrammetry is a method developed in the early XIXth century. Nowadays, with digital photography associated to the development of image processing and its automation, this technique has become appealing in different fields of application. In this paper, the authors analysed the current feasibility and advantages of using photogrammetry in structural monitoring. First, the method was calibrated using two laboratorial tests: (1) monitoring of failure and creep tests of long-span reinforced concrete beams; and (2) monitoring of steel beam-to-column connections. Then, the method was tested on site, namely, in monitoring the deformations of a footbridge subjected to different loading situations. It was concluded that photogrammetry can be used in structural monitoring with accuracy and exhibiting additional advantages in relation to traditional methods, namely: (1) an almost unlimited number of measuring points can be considered and automatically processed; and (2) hardware is unnecessary and, therefore, it can be used under almost any situation where traditional methods cannot be employed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Localization of deformable tumors from short-arc projections using Bayesian estimation

Purpose: The authors present a stochastic framework for radiotherapy patient positioning directly utilizing radiographic projections. This framework is developed to be robust against anatomical nonrigid deformations and to cope with challenging imaging scenarios, involving only a few cone beam CT projections from short arcs. Methods: Specifically, a Bayesian estimator (BE) is explicitly derived for the given scanning geometry. This estimator is compared to reference methods such as chamfer matching (CM) and the minimization of the median absolute error adapted as tools of robust image processing and statistics. In order to show the performance of the stochastic short-arc patient positioning method, a CIRS IMRT thorax phantom study is presented with movable markers and the utilization of an Elekta Synergy{sup Registered-Sign} XVI system. Furthermore, a clinical prostate CBCT scan of a Varian{sup Registered-Sign} On-Board Imager{sup Registered-Sign} system is utilized to investigate the robustness of the method for large variations of image quality (anterior-posterior vs lateral views). Results: The results show that the BE shifts reduce the initial setup error of up to 3 cm down to 3 mm at maximum for an imaging arc as short as 10 Degree-Sign while CM achieves residual errors of 7 mm at maximum only for arcs longer than 40 Degree-Sign . Furthermore, the BE can compensate robustly for low image qualities using several low quality projections simultaneously. Conclusions: In conclusion, an estimation method for marker-based patient positioning for short imaging arcs is presented and shown to be robust and accurate for deformable anatomies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Meso-scale imaging of composite materials

The performance of composite materials is controlled by the interaction between the individual components as well as the mechanical characteristics of the components themselves. Geometric structure on the meso-scale, where the length-scales are of the same order as the material granularity, plays a key role in controlling material performance and having a quantitative means of characterizing this structure is crucial in developing our understanding of NDE technique signatures of early damage states. High-resolution computed tomography (HRCT) provides an imaging capability which can resolve these structures for many composite materials. Coupling HRCT with three-dimensional physics-based image processing enables quantitative characterization of the meso-scale structure. Taking sequences of these damage states provides a means to structurally observe the damages evolution. We will discuss the limits of present 3DCT capability and challenges for improving this means to rapidly generate structural information of a composite and of the damage. In this presentation we will demonstrate the imaging capability of HRCT.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SU-G-201-01: An Automated Treatment Plan Quality Assurance Program for High-Dose Rate (HDR) Brachytherapy with a VaginalCylinder Applicator

Purpose: Plan specific quality assurance (QA) is an important step in high dose rate (HDR) brachytherapy to ensure the integrity of a treatment plan. The conventional approach is to assemble a set of plan screen-captures in a document and have an independent plan-checker to verify it. Not only is this approach cumbersome and time-consuming, using a document also limits the items that can be verified, hindering plan quality and patient safety. We have initiated efforts to develop a web-based HDR brachytherapy QA system called AutoBrachy QA, for comprehensive and efficient QA. This abstract reports a new plugin in this system for the QA of a cylinder HDR brachytherapy treatment. Methods: A cylinder plan QA module was developed using Python. It was plugged into our AutoBrachy QA system. This module extracted information from CT images and treatment plan. Image processing techniques were employed to obtain geometric parameters, e.g. cylinder diameter. A comprehensive set of eight geometrical and eight dosimetric features of the plan were validated against user specified planning parameter, such as prescription value, treatment depth and length, etc. A PDF document was generated, consisting of a summary QA sheet with all the QA results, as well as images showing plan details. Results: The cylinder QA program has been implemented in our clinic. To date, it has been used in 11 patient cases and was able to successfully perform QA tests in all of them. The QA program reduced the average plan QA time from 7 min using conventional manual approach to 0.5 min. Conclusion: Being a new module in our AutoBrachy QA system, an automated treatment plan QA module for cylinder HDR brachytherapy has been successfully developed and clinically implemented. This module improved clinical workflow and plan integrity compared to the conventional manual approach.

60 APPLIED LIFE SCIENCES↗