Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Infrared emission from H II regions

Analysis of observations made at infrared wavelengths of a large number of H II regions. Several types of IR sources are found associated with H II regions, and a single region can contain a number of varied IR emitting objects. The main sources of IR emission are ionized hydrogen concentrations, heated dust particles, and OH/H2O masers. Flux density maps for both radio and IR emission suggest that there is a physical association between the IR and radio-emitting regions. The properties of several H II regions indicate that they may be protostellar objects at various stages of evolution.

Wynn-Williams, C. G.↗

Infrared studies of H II regions and OH sources

This paper presents the observational results of a high spatial-resolution mapping and photometric study in the wavelength range from 1.65 to 20 microns of four H II regions and seven OH sources. Infrared emission indicative of the presence of heated dust was found from the compact H II condensations in W51, DR21, and NGC7538. Infrared emission was also found from the positions of maser sources in NGC 7538, W75(N) W75(S) and Sharpless 269, but not from that in W51. An extended infrared source was found coincident with the peculiar OH source OH 0739-14.

Wynn-Williams, C. G.↗

Accurate positions of OH sources

The Owens Valley interferometer was used at 1665, 1667, and 1720 MHz to measure the positions of eleven OH emission sources. The 1720-MHz OH source in W3 (continuum) was found to be 40 seconds away from the H2O maser source and was found not to coincide with any radio or infrared feature. Two OH emission sources were found in NGC 7538; one is identifiable with a very compact radio infrared source, while the other, 80 seconds to the south, is as yet unidentified. The OH sources 0739-14 and Sharpless 269 also coincide with infrared sources.

Wynn-Williams, C. G.↗

A tracking polarimeter for measuring solar and ionospheric Faraday rotation of signals from deep space probes

A tracking polarimeter implemented on the 64-m NASA/JPL paraboloid antenna at Goldstone, Calif., is described. Its performance is analyzed and compared with measurements. The system was developed to measure Faraday rotation in the solar corona of the telemetry carrier from the Pioneer VI spacecraft as it was occulted by the sun. It also measures rotation in the earth's ionosphere and is an accurate method of determining spacecraft orientation. The new feature of this system is its use of a pair of quarter-wave plates to allow the synthesis of a rotating feed system, while requiring the rotation of only a single section of waveguide. Since the polarization sensing is done at RF and the receiver operates essentially as a null detector, the system's accuracy is superior to other polarization tracking schemes. In addition, the antenna size and maser preamplifier provide unsurpassed sensitivity. The associated instrumentation used in the Pioneer VI experiment is also described.

Ohlson, J. E.↗

Detection of the J = 1 to 0 rotational transition of vibrationally excited silicon monoxide

The v = 1,J = 1 to 0 rotational transition of SiO at 43.1 GHz has been detected in the direction of Becklin's star in the Orion Nebula, and in the M-type star W Hya. In Orion two velocity components are observed, one (the stronger) at a radial velocity of 17 km/sec, the other at -7 km/sec; in W Hya a single line is observed at 39 km/sec. In each case a line at the same radial velocity has been observed at 86.2 GHz in the v = 1,J = 2 to 1 transition, so that the presence of vibrationally excited SiO would seem to be confirmed beyond a reasonable doubt. In the v = 1 state, the photon fluxes of the J = 2 to 1 and 1 to 0 transitions are about equal, suggesting saturated masers occupying the same region of space.

Thaddeus, P.↗

Low-noise K(u)-band receiver input system

Improved maser and superconducting magnet, which operates in vacuum of closed-cycle helium refrigerator, comprise a low-noise, reliable, field-operational receiver input system.

Berwin, R. W.↗

Performance of the new Efratom optically pumped rubidium frequency standards and their possible application in space relativity experiments

The characteristics of Efratom optically pumped rubidium frequency standards are discussed. The Efratom units were compared with cesium beam and hydrogen maser standards and showed a stability of approximately 5 times 10 to the minus 12th power over two one-week periods. Dependency of frequency upon the environmental parameters of pressure, magnetic field, temperature, supply voltage, and acceleration was measured. A package of three units with automatic phase comparison and recording was designed and constructed to allow a measurement of relativistic effects on time with high accuracy during space missions.

Alley, C. O.↗

Time, geodesy, and astrometry: Results from radio interferometry

The results from a total of a dozen transcontinental and intercontinental VLBI experiments are discussed. Particular emphasis is placed on: (1) the inferred behavior of the frequency standards, usually hydrogen masers, on time scales from 10 to 100,000 seconds; (2) the estimated celestial positions of the observed radio sources; (3) the determinations of the vector baselines; and (4) the inferred values of polar motion and UT.1.

Clark, T. A.↗

Bonding of sapphire to sapphire by eutectic mixture of aluminum oxide and zirconium oxide

Bonding of an element comprising sapphire, ruby or blue sapphire to another element of such material with a eutectic mixture of aluminum oxide and zirconium oxide is discussed. The bonding mixture may be applied in the form of a distilled water slurry or by electron beam vapor deposition. In one embodiment the eutectic is formed in situ by applying a layer of zirconium oxide and then heating the assembly to a temperature above the eutectic temperature and below the melting point of the material from which the elements are formed. The formation of a sapphire rubidium maser cell utilizing eutectic bonding is shown.

Deluca, J. J.↗

A review of precision oscillators

Precision oscillators used in PTTI applications include quartz crystal, rubidium gas cell, cesium beam, and hydrogen maser oscillators. A general characterization and comparison of these devices is given including accuracy, stability, environmental sensitivity, size, weight, power consumption, availability and cost. Areas of special concern in practical applications are identified and a projection of future performance specifications is given. An attempt is made to predict physical and performance characteristics of new designs potentially available in the near future.

Hellwig, H.↗

Application of very long baseline interferometry to Astrometry and Geodesy: effects of frequency standard instability on accuracy

The accuracy of geodetic and astrometric information obtained from very long baseline interferometry (VLBI) observations is dependent upon the stability of the frequency standard, or clock, used at each site of VLBI array. The sensitivities of two hydrogen maser frequency standards of different design to pressure, temperature, and magnetic field variations were measured; and, for one of the standards, sensitivity was found to be severe enough to degrade the information content of VLBI measurements. However, the effect on the geometric and astrometric information of such clock instabilities, with time scales of hours or greater, can be sharply reduced through the use of differencing techniques.

Clark, T. A.↗

Infrared, X-ray, and XUV astrophysics

An observational program covering wavelengths from the near infrared to 1 millimeter is reviewed. The program of millimeter observations largely consisted of analyzing previous observations since the summer humidity was too high for new observations. Maps of millimeter emission from W3, Sgr B2, W49 and M42 were made. Five extragalactic sources were detected and are discussed. Energy distributions of several of the discrete sources at the Galactic Center were studied. A 5-year visual/infrared program on Markarian galaxies is discussed which showed the presence of both thermal and nonthermal infrared radiation sources and established correlations between the infrared sources and the emission line regions. The Nova Cygnus 1975, caught during its rise as well as subsequent dimming, is also discussed. Several other continuing programs are described, including studies of dark clouds and CO maser sources.

Source record↗

Atomic frequency standard relativistic Doppler shift experiment

An experiment has been performed to measure possible space anisotropy as it would effect the frequency of a cesium atomic beam standard clock in a laboratory on earth due to motion relative to external coordinate frames. The cesium frequency was measured as a function of orientation with respect to an atomic hydrogen maser standard. Over a period of 34 days 101 measurements were made. The results are consistent with a conclusion that no general orientation dependance attributable to spacial anisotropy was observed. It is shown that both the airplane clock results, and the null results for the atomic beam clock, are consistent with Einstein general or special relativity, or with the Lorentz transformations alone.

Peters, H. E.↗

Radio detection of interstellar sulfur dioxide

Interstellar sulfur dioxide (SO2) has been detected in emission from the direction of the Orion Nebula molecular cloud and from Sgr B2. SO2 is the heaviest interstellar molecule detected to date, and the only nonlinear triatomic molecule which does not contain hydrogen. The remarkable Orion emission profiles suggest that two components are supporting the SO2 emission: a dense circumstellar-type envelope, which may be in maser emission, and a warm galactic cloud component.

Snyder, L. E.↗

Observations of 1-millimeter continuum radiation from the DR 21 region

Continuum emission at 1 mm has been mapped with 1-min resolution over a 3-min by 8-min area including the compact H II region DR 21, the maser source W75(S)-OH, and the central portions of the surrounding molecular cloud. Peaks in the 1-mm intensity are observed at the positions of DR 21 and W75(S)-OH, and are roughly coincident with less marked peaks in the intensity of HCN and CO emission. An extended component of 1-mm emission is present as well. The principal source of 1-mm radiation is thought to be thermal emission from dust within the molecular gas. The characteristics of this radiation which make it a promising tool for the study of molecular clouds are briefly discussed.

Werner, M. W.↗

A 100-kHz frequency divider, distribution amplifier

A frequency divider, distribution amplifier module having low phase noise and low phase drift with temperature and high isolation between outputs was developed for use in the hydrogen maser frequency standard, where it divides 1 MHz from the previous frequency divider down to 100 kHz and provides four transistor-transistor logic (TTL) outputs.

Lutes, G.↗

DSN research and technology support

Continuing testing and refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine pulsar observations of 22 pulsars. Radar observations of geostationary satellite are discussed. Current status of the 400-kW X-band radar is reported along with routine automatic testing of the stability-reliability of the DSS 13 maser-receiver noise adding radiometer combination. A failure in the Faraday rotation receiving system is noted along with discussion in some detail of the activities of the high power transmitter maintenance facility. Continuation of receiver phase stability testing, specifically the effects of temperature on coaxial cables, is discussed and results reported. A demonstration at full power of the microwave power transmission facility is noted and routine support of the planetary radio astronomy experiment is discussed. Transmission of master clock synchronization signals to overseas DSN stations is also reported.

Jackson, E. B.↗

DSN research and technology support

The activities of the Venus Station (DSS 13) and the Microwave Test Facility (MTF) during the period April 19 through June 13, 1976, are discussed and progress noted. Continuing reliability testing and computer program refinement of the remote controlled, unattended automated pulsar observing station is noted, along with routine observations of 17 pulsars. Radar observations of a geostationary satellite are reported, along with the routine automatic testing of the stability of the DSS 13 maser-receiving system. Additional testing of thermal characteristics of semiflexible coaxial cables is reported, along with phase stabilization measurements thereon. Routine support of the planetary radio astronomy experiment, with 43.25 hours of observations of Jupiter and various radio calibration sources, is reported, along with 18.75 hours of differential VLBI observations in conjunction with Australia, DSS 43. Modifications of the clock synchronization winterization system are reported, along with a discussion of the activities of the DSN High-Power Transmitter Maintenance Facility.

Jackson, E. B.↗