Search NASA⌕ Search

SEARCH · Search NASA

Results for “Maximization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Optimized nested Markov chain Monte Carlo sampling: theory

Metropolis Monte Carlo sampling of a reference potential is used to build a Markov chain in the isothermal-isobaric ensemble. At the endpoints of the chain, the energy is reevaluated at a different level of approximation (the 'full' energy) and a composite move encompassing all of the intervening steps is accepted on the basis of a modified Metropolis criterion. By manipulating the thermodynamic variables characterizing the reference system we maximize the average acceptance probability of composite moves, lengthening significantly the random walk made between consecutive evaluations of the full energy at a fixed acceptance probability. This provides maximally decorrelated samples of the full potential, thereby lowering the total number required to build ensemble averages of a given variance. The efficiency of the method is illustrated using model potentials appropriate to molecular fluids at high pressure. Implications for ab initio or density functional theory (DFT) treatment are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanoradian angular stabilization of x-ray optical components

An x-ray free-electron laser oscillator (XFELO) has been recently proposed [K. Kim et al., Phys. Rev. Lett. 100, 244802 (2008)]. Angular orientation and position in space of Bragg mirrors of the XFELO optical cavity must be continuously adjusted to compensate for the instabilities and maximize the output intensity. An angular stability of about 10 nrad (rms) is required [K. Kim and Y. Shvyd'ko, Phys. Rev. ST Accel. Beams 12, 030703 (2009)]. To approach this goal, a feedback loop based on a null-detection principle was designed and used for stabilization of a high-energy-resolution x-ray monochromator ({Delta}E/E{approx_equal}4x10{sup -8}, E=23.7 keV) and a high-heat-load monochromator. Angular stability of about 13 nrad (rms) has been demonstrated for x-ray optical elements of the monochromators.

43 PARTICLE ACCELERATORS↗

Operators on Pure Spinor Spaces

Pure spinors are relevant to the formulation of supersymmetric theories, and provide the only known way to maintain manifest maximal supersymmetry. The (non-linear) pure spinor constraint makes it nontrivial to find well defined operators on pure spinor wave functions. We discuss how such operators are defined. One application concerns covariant gauge fixing in maximally supersymmetric Yang-Mills (and string theory). Another issue is the construction of a manifestly supersymmetric action for 11-dimensional supergravity in terms of a scalar superfield. We describe some work in progress.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Parametric Optimization of Undulators for NSLS-II Project Beamlines

General optimization procedure, computation methods used, and the obtained optimal parameters of undulators for the NSLS-II project beamlines are reported. The optimization starts with high-accuracy calculation of undulator magnetic fields, using Radia magnetostatics code, for a large set of periods and vertical gaps of a given undulator type, given magnetic materials and a scalable magnet geometry. From the resulting magnetic fields, a sub-set of undulator periods and the corresponding vertical gaps, providing the required low-energy cut-off values of spectral harmonics for each particular beamline, is determined. In parallel, from the same Radia undulator models, angular magnetic kick maps are calculated, and the insertion device effect on electron beam is simulated using Tracy-2 tracking code based on symplectic integrator. After these simulations, magnet parameters are fine-tuned and the maximal acceptable undulator lengths are determined for different straight sections, as functions of minimal gap and with due regard for the electron beam vertical ''stay clear'' constraint in the case of in-vacuum undulators. Finally, the optimal undulator period and length are determined as the values providing maximal spectral flux among the pre-selected undulator cases, already satisfying the requirements concerning the harmonic cut-off values and the effect on electron beam.

43 PARTICLE ACCELERATORS↗

A test cassette for x-ray-exposure experiments at the National Ignition Facility

We present the design and operation of a test cassette for exposure of samples to radiation environments at the National Ignition Facility. The cassette provides options for square and round samples and exposure areas; the cassette provides for multiple levels of filtration on a single sample, which allows dynamic range in experiments. The samples had normal lines of sight to the x-ray source in order to have uniform x-ray illumination. The incident x-radiation onto the samples was determined by the choice of filter thicknesses and materials. The samples were held at precise locations, accurate to within a few hundred microns, in the target chamber in order to have a known fluence incident. In the cassette, the samples were held in place in such a way that a minimal ''line contact'' allows them to have the maximal mechanical response to the x-ray load. We present postshot images of the debris found on films used for filters, and pre- and postexposure specimens.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Search for Exotic Mesons in {gamma}p{yields}{pi}{sup +{pi}+{pi}-}n with CLAS at Jefferson Lab

In addition to ordinary qq-bar pairs, quantum chromodynamics (QCD) permits many other possibilities in meson spectra, such as gluonic hybrids, glueballs, and tetraquarks. Experimental discovery and study of these exotic states provides insight on the nonperturbative regime of QCD. Over the past twenty years, some searches for exotic mesons have met with controversial results, especially those obtained in the three-pion system. Prior theoretical work indicates that in photoproduction one should find gluonic hybrids at significantly enhanced levels compared to that found in pion production. To that end, the CLAS g12 run was recently completed at Jefferson Lab, using a liquid hydrogen target and tagged photons from a 5.71 GeV electron beam. The CLAS experimental apparatus was modified to maximize forward acceptance for peripheral production of mesons. The resulting data contains the world's largest 3{pi} photoproduction dataset, with {gamma}p{yields}{pi}{sup +{pi}+{pi}-}n events numbering in the millions. Early results describing the data quality, kinematics, and dysnamics will be shown.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Standard design for National Ignition Facility x-ray streak and framing cameras

The x-ray streak camera and x-ray framing camera for the National Ignition Facility were redesigned to improve electromagnetic pulse hardening, protect high voltage circuits from pressure transients, and maximize the use of common parts and operational software. Both instruments use the same PC104 based controller, interface, power supply, charge coupled device camera, protective hermetically sealed housing, and mechanical interfaces. Communication is over fiber optics with identical facility hardware for both instruments. Each has three triggers that can be either fiber optic or coax. High voltage protection consists of a vacuum sensor to enable the high voltage and pulsed microchannel plate phosphor voltage. In the streak camera, the high voltage is removed after the sweep. Both rely on the hardened aluminum box and a custom power supply to reduce electromagnetic pulse/electromagnetic interference (EMP/EMI) getting into the electronics. In addition, the streak camera has an EMP/EMI shield enclosing the front of the streak tube.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solar Pumped Laser Microthruster

The development of microsatellites requires the development of engines to modify their orbit. It is natural to use solar energy to drive such engines. For an unlimited energy source the optimal thruster must use a minimal amount of expendable material to minimize launch costs. This requires the ejected material to have the maximal velocity and, hence, the ejected atoms must be as light as possible and be ejected by as high an energy density source as possible. Such a propulsion can be induced by pulses from an ultra-short laser. The ultra-short laser provides the high-energy concentration and high-ejected velocity. We suggest a microthruster system comprised of an inflatable solar concentrator, a solar panel, and a diode-pumped fiber laser. We will describe the system design and give weight estimates.

14 SOLAR ENERGY↗

Ionic wind generation by a wire-cylinder-plate corona discharge in air at atmospheric pressure

A wire-cylinder-plate electrode configuration is presented to generate ionic wind with a dc corona discharge in air at atmospheric pressure. The objective of the work is to maximize the power supplied to the flow in order to increase acceleration while avoiding breakdown. Thus, the proposed experimental setup addresses the problem of decoupling the mechanism of ion generation from that of ion acceleration. Using a wire-plate configuration as a reference, we have focused on improving the topography of the electric field to (1) separate the ionization and acceleration zones in space, and (2) guide the trajectory of charged particles as parallel to the median axis as possible. In the proposed wire-cylinder-plate setup, a dc corona discharge is generated in the space between a wire and two cylinders. The ions produced by the corona then drift past the cylinders and into a channel between two plates, where they undergo acceleration. To maximize the ionic wind it is found that the geometric configuration must be as compact as possible and that the voltage applied must be right below breakdown. Experimentally, the optimized wire-plate reference setup provides a maximum flow velocity of 8 m s{sup -1}, a flow rate per unit electrode length of 0.034 m{sup 2} s{sup -1}, and a thrust per unit electrode length of 0.24 N m{sup -1}. The wire-cylinder-plate configuration provides a maximum flow velocity of 10 m s{sup -1}, a flow rate per unit electrode length of 0.041 m{sup 2} s{sup -1}, and a thrust per unit electrode length of 0.35 N m{sup -1}. This 46% increase in thrust is obtained by increasing the electric power per unit electrode length by only 16% (from 175 to 210 W m{sup -1}), which confirms the gain in efficiency obtained with the decoupled system. In comparison with a simple wire-wire corona configuration, the wire-cylinder-plate configuration increases the ionic wind velocity by up to a factor of 3, and the thrust by an order of magnitude.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The Dynamical Nonlocality of Neutral Kaons and the Kaonic Quantum Eraser

Testing quantum foundations for systems in high energy physics gets currently more and more attention e.g. witnessed for entangled neutral K-mesons by the approved programme of the KLOE collaboration at the accelerator facility DAPHNE (Frascati, Italy). We focus on this quantum system in high energy physics and discuss two topics, Bell inequalities and the kaonic quantum eraser, and show how the neutral kaon system differs from systems of ordinary matter and light. In detail, we show a relation of the imbalance of matter and antimatter to the violation of a Bell inequality and discuss another Bell inequality which is maximally violated for a non-maximally entangled state though neutral kaons can be considered as two state systems. We compare in general this system in high energy physics with bipartite qudits. Last but not least we review the quantum marking and eraser procedure and explain why neutral kaons offer more eraser possibilities than usual quantum systems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Neutron Based Interrogation System For SNM In Cargo

A complete system has been simulated using experimentally obtained input parameters for the detection of special nuclear materials (SNM). A variation of the associated particle imaging (API) technique, referred to as reverse associated particle imaging detection (RAPID), has been developed in the context of detecting 5-kg spherical samples of U-235 in cargo. The RAPID technique allows for the interrogation of containers at neutron production rates between {approx}1x10{sup 8} neutrons/s and {approx}3x10{sup 8} neutrons/s. The merit of performance for the system is the time to detect the threat material with 95% probability of detection and 10{sup -4} false positive rate per interrogated voxel of cargo. Detection times of 5 minutes were found for a maximally loaded cargo container uniformly filled with iron and as low as 1 second in containers loaded to 1/4 of full capacity with either iron or wood. The worse case system performance, 30 minutes interrogation time, occurs for a maximally loaded container containing wood at 0.4 g/cm{sup 3}.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring the 2{gamma} Exchange Effect in Electron-Proton Scattering at CLAS

Recent results from experiments at Jefferson Laboratory, Newport News VA, which measure the ratio of the electric to magnetic form factors of the proton, G{sub E}/G{sub M}, have forced us to reexamine the single photon exchange approximation in lepton-proton elastic scattering. Discrepancies between the ratio obtained via the time-tested Rosenbluth separation method and new polarization transfer measurements, which differ by as much as a factor of three, may be resolved by considering the effect of two photon exchange (TPE). Theoretical corrections for the TPE effect are difficult due to the large number of excited nucleon states that can contribute to the process. The TPE effect can, however, be determined directly by measuring the ratio of the positron-proton to electron-proton elastic scattering cross sections, R = {sigma}(e{sup +})/{sigma}(e{sup -}), since the TPE effect changes sign with the charge of the incident particle. The CLAS TPE experiment at Jefferson Laboratory, will determine the effect of two-photon exchange in elastic lepton-proton scattering by precisely measuring the ratio of positron-proton to electron-proton elastic cross sections over a large kinematic range (0.1<{epsilon}<0.96, 0.02{<=}Q{sup 2}{<=}2.0). We will accomplish this by directing the 5.5 GeV primary electron beam, provided by the Continuous Electron Beam Accelerator Facility (CEBAF), onto a set of radiators and converters to produce simultaneous and identical beams of electron and positrons. Acceptance and efficiency concerns are minimized by only considering the ratios of the elastic cross sections and switching polarity of magnets in the beam line and the spectrometer. Guided by the results of a short 2006 test run and extensive GEANT based modeling, new shielding and beam line components were designed to maximize luminosity. The unique experimental design and challenges of the TPE experiment and the projected luminosities will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multiquark Correlations in Light Mesons and Baryons from holographic QCD

A hadron's multiquark content reflects itself in the quark composition of the interpolator with which it has maximal overlap. The AdS/CFT dictionary translates the anomalous dimension of this interpolator into a mass correction for the corresponding dual mode. Hence such bulk-mass corrections can carry specific information on multiquark correlations. Two prominent examples are studied by implementing this robust and universal holographic mechanism into AdS/QCD gravity duals. In the baryon sector bulk-mass corrections are used to describe systematic good (i.e. maximally attractive) diquark effects. The baryon sizes are predicted to decrease with increasing good-diquark content, and the masses of all 48 observed light-quark baryon states are reproduced with unprecedented accuracy. Our approach further provides the first holographic description of a dominant tetraquark component in the lowest-lying scalar mesons. The tetraquark ground state emerges naturally as the lightest scalar nonet whereas higher excitations become heavier than their quark--antiquark counterparts and are thus likely to dissolve into the multiparticle continuum.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Control of resonance enhanced multi-photon ionization photoelectron spectroscopy by phase-shaped femtosecond laser pulse

In this paper, we theoretically demonstrate that the (2+1+1) resonance enhanced multi-photon ionization photoelectron spectroscopy in sodium atom can be effectively controlled by shaping femtosecond laser pulse with a {pi} phase step modulation in weak laser field, involving its total photoelectron energy, maximal photoelectron intensity, and spectroscopic bandwidth. Our results show that the total photoelectron energy can be suppressed but not enhanced, the maximal photoelectron intensity can be enhanced and also suppressed, and the photoelectron spectroscopy can be tremendously narrowed. These theoretical results can provide a feasible scheme to achieve the high-resolution photoelectron spectroscopy and study the excited state structure in atomic and molecular systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Arbitrarily small amounts of correlation for arbitrarily varying quantum channels

As our main result show that in order to achieve the randomness assisted message and entanglement transmission capacities of a finite arbitrarily varying quantum channel it is not necessary that sender and receiver share (asymptotically perfect) common randomness. Rather, it is sufficient that they each have access to an unlimited amount of uses of one part of a correlated bipartite source. This access might be restricted to an arbitrary small (nonzero) fraction per channel use, without changing the main result. We investigate the notion of common randomness. It turns out that this is a very costly resource – generically, it cannot be obtained just by local processing of a bipartite source. This result underlines the importance of our main result. Also, the asymptotic equivalence of the maximal- and average error criterion for classical message transmission over finite arbitrarily varying quantum channels is proven. At last, we prove a simplified symmetrizability condition for finite arbitrarily varying quantum channels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimal system size for complex dynamics in random neural networks near criticality

In this article, we consider a model of dynamical agents coupled through a random connectivity matrix, as introduced by Sompolinsky et al. [Phys. Rev. Lett. 61(3), 259–262 (1988)] in the context of random neural networks. When system size is infinite, it is known that increasing the disorder parameter induces a phase transition leading to chaotic dynamics. We observe and investigate here a novel phenomenon in the sub-critical regime for finite size systems: the probability of observing complex dynamics is maximal for an intermediate system size when the disorder is close enough to criticality. We give a more general explanation of this type of system size resonance in the framework of extreme values theory for eigenvalues of random matrices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Production of high intensity {sup 48}Ca for the 88-Inch Cyclotron and other updates

Recently the Versatile ECR for NUclear Science (VENUS) ion source was engaged in a 60-day long campaign to deliver high intensity {sup 48}Ca{sup 11+} beam to the 88-Inch Cyclotron. As the first long term use of VENUS for multi-week heavy-element research, new methods were developed to maximize oven to target efficiency. First, the tuning parameters of VENUS for injection into the cyclotron proved to be very different than those used to tune VENUS for maximum beam output of the desired charge state immediately following its bending magnet. Second, helium with no oxygen support gas was used to maximize the efficiency. The performance of VENUS and its low temperature oven used to produce the stable requested 75 eμA of {sup 48}Ca{sup 11+} beam current was impressive. The consumption of {sup 48}Ca in VENUS using the low temperature oven was checked roughly weekly, and was found to be on average 0.27 mg/h with an ionization efficiency into the 11+ charge state of 5.0%. No degradation in performance was noted over time. In addition, with the successful operation of VENUS the 88-Inch cyclotron was able to extract a record 2 pμA of {sup 48}Ca{sup 11+}, with a VENUS output beam current of 219 eμA. The paper describes the characteristics of the VENUS tune used for maximum transport efficiency into the cyclotron as well as ongoing efforts to improve the transport efficiency from VENUS into the cyclotron. In addition, we briefly present details regarding the recent successful repair of the cryostat vacuum system.

43 PARTICLE ACCELERATORS↗

Chaotic vibrations of the duffing system with fractional damping

We examined the Duffing system with a fractional damping term. Calculating the basins of attraction, we demonstrate a broad spectrum of non-linear behaviour connected with sensitivity to the initial conditions and chaos. To quantify dynamical response of the system, we propose the statistical 0-1 test as well as the maximal Lyapunov exponent; the application of the latter encounter a few difficulties because of the memory effect due to the fractional derivative. The results are confirmed by bifurcation diagrams, phase portraits, and Poincaré sections.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗