Search NASA⌕ Search

SEARCH · Search NASA

Results for “Microfluidic”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Hybrid nanocapsules for in situ TEM imaging of gas evolution reactions in confined liquids

Liquid cell transmission electron microscopy (TEM) enables the direct observation of dynamic physical and chemical processes in liquids at the nanoscale. Quantitative investigations into reactions with fast kinetics and/or multiple reagents will benefit from further advances in liquid cell design that facilitate rapid in situ mixing and precise control over reagent volumes and concentrations. This work reports the development of inorganic–organic nanocapsules for high-resolution TEM imaging of nanoscale reactions in liquids with well-defined zeptoliter volumes. These hybrid nanocapsules, with 48 nm average diameter, consist of a thin layer of gold coating a lipid vesicle. As a model reaction, the nucleation, growth, and diffusion of nanobubbles generated by the radiolysis of water is investigated inside the nanocapsules. When the nanobubbles are sufficiently small (10–25 nm diameter), they are mobile in the nanocapsules, but their movement deviates from Brownian motion, which may result from geometric confinement by the nanocapsules. Gases and fluids can be transported between two nanocapsules when they fuse, demonstrating in situ mixing without using complex microfluidic schemes. The ability to synthesize nanocapsules with controlled sizes and to monitor dynamics simultaneously inside multiple nanocapsules provides opportunities to investigate nanoscale processes such as single nanoparticle synthesis in confined volumes and biological processes such as biomineralization and membrane dynamics.

36 MATERIALS SCIENCE↗

Hanging drop sample preparation improves sensitivity of spatial proteomics

Spatial proteomics holds great promise for revealing tissue heterogeneity in both physiological and pathological conditions. However, one significant limitation of most spatial proteomics workflows is the requirement of large sample amounts that blurs cell-type-specific or microstructure-specific information. In this study, we developed an improved sample preparation approach for spatial proteomics and integrated it with our previously-established laser capture microdissection (LCM) and microfluidics sample processing platform. Specifically, we developed a hanging drop (HD) method to improve the sample recovery by positioning a nanowell chip upside-down during protein extraction and tryptic digestion steps. Compared with the commonly-used sitting-drop method, the HD method keeps the tissue pixel away from the container surface, and thus improves the accessibility of the extraction/digestion buffer to the tissue sample. The HD method can increase the MS signal by 7 fold, leading to a 66% increase in the number of identified proteins. An average of 721, 1489, and 2521 proteins can be quantitatively profiled from laser-dissected 10 μm-thick mouse liver tissue pixels with areas of 0.0025, 0.01, and 0.04 mm 2 , respectively. The improved system was further validated in the study of cell-type-specific proteomes of mouse uterine tissues.

47 OTHER INSTRUMENTATION↗

Hydrodynamics of a multicomponent vesicle under strong confinement

Herein we numerically investigate the hydrodynamics and membrane dynamics of a multicomponent vesicle in two strongly confined geometries. This serves as a simplified model for red blood cells undergoing large deformations while traversing narrow constrictions. We propose a new parameterization for the bending modulus that remains positive for all lipid phase parameter values. For a multicomponent vesicle passing through a stenosis, we establish connections between various properties: lipid phase coarsening, size and flow profile of the lubrication layers, excess pressure, and the tank-treading velocity of the membrane. For a multicomponent vesicle passing through a contracting channel, we find that the lipid always phase separates so that the vesicle is stiffer in the front as it passes through the constriction. For both cases of confinement we find that lipid coarsening is arrested under strong confinement, and resumes at a high rate upon relief from extreme confinement. The results may be useful for efficient sorting lipid domains using microfluidic flows by controlled release of vesicles passing through strong confinement.

97 MATHEMATICS AND COMPUTING↗

Quantitative local state of charge mapping by operando electrochemical fluorescence microscopy in porous electrodes

We introduce operando quantitative electrochemical fluorescence state of charge mapping (QEFSM), a non-invasive technique to study operating electrochemical systems along with a new design of optically transparent microfluidic redox flow cells compatible with the most demanding optical requirements. QEFSM allows quantitative mappings of the concentration of a particular oxidation state of a redox-active species within a porous electrode during its operation. In this study, we used confocal microscopy to map the fluorescence signal of the reduced form of 2,7-anthraquinone disulfonate (AQDS) in a set of multistep-chronoamperometry experiments. Calibrating these images and incorporating an analytical model of quinhydrone heterodimer formation with no free parameters, and accounting for the emission of each species involved, we determined the local molecular concentration and the state of charge (SOC) fields within a commercial porous electrode during operation. With this method, electrochemical conversion and species advection, reaction and diffusion can be monitored at heretofore unprecedented transverse and axial resolution (1 μm and 25 μm, respectively) at frame rates of 0.5 Hz, opening new routes to understanding local electrochemical processes in porous electrodes. Here, we observed pore-scale SOC inhomogeneities appearing when the fraction of electroactive species converted in a single pass through the electrode becomes large.

42 ENGINEERING↗

Enhanced reactivity at the oil–water interface accelerates the synthesis of zymonic acid in microemulsions

Chemical reactions in microscale compartments, such as aerosols and emulsions, can exhibit significantly faster reaction rates relative to macroscale containers. This enhancement in chemistry is often due to the elevated importance of surfaces as reaction vessels are reduced to picoliter volumes. While most studies have focused on the air-water interface of droplets, there are comparably fewer studies of reactions in micron-scale aqueous solutions encapsulated by oil. Here we investigate the condensation reaction of pyruvic acid (PA) to form zymonic acid (ZA) and water. Using microfluidics and optical trapping, chemical kinetics are measured in monodisperse micron-sized emulsion droplets in situ via Raman spectroscopy. Relative to a macroscopic bulk solution, which exhibits little to no reaction over many days, we find efficient production of ZA over the same time period. A kinetic model is developed to elucidate the role of the interface in accelerating the microdroplet reaction kinetics. After quantifying the surface partitioning of PA from interfacial tension measurements, the rate coefficient for the condensation reaction at the oil-water interface is determined to be 1.8 × 10-2 M-1 s-1. This rate coefficient is estimated to be 105 larger than the reaction rate in bulk aqueous solutions. Compared to previous studies of accelerated ZA formation at the air-water interface on nanodroplets, we find that the reaction at the oil-water interface is 20 times more efficient. Despite this difference, the overall ZA formation rate in emulsions is significantly slower than in the same-sized aerosols, which arises from the weaker partitioning of PA to the oil-aqueous relative to air-water interface. These results highlight the interplay between interfacial partitioning and reactivity in accelerating chemistry in microcompartments and provides new insights into how interfacial composition influences condensation reactions.

Wallace, Brandon J↗

Dynamical theory for diffractive x-ray imaging of one-dimensional periodic objects

A dynamical theory for diffractive x-ray imaging of one-dimensional periodic objects is derived by solving the Helmholtz equation in the parabolic approximation using the coupled-wave theory. A method to account for volume-diffraction effects, based on propagating backwards the eigenmodes of the microfluidic array, is demonstrated for a colloidal suspension in confinement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Light driven microflow in ice

We optically pump water through micrometer thin ice sheets. The ice is locally moved with speeds exceeding 5 cm/s by repetitive melting and freezing, which occurs around a moving infrared laser spot. The minimal channel width is 10 {mu}m. The diffusion limitation of ice allows for fast spatial biomolecule control without predefined channels, valves, or external pumps. Dye molecules are pumped across an ice-ice interface, showing the possibility of microfluidic applications. Pumping in ice is three orders of magnitude faster than the previously shown for thermoviscous pumping in water.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lithography with MeV Energy Ions for Biomedical Applications: Accelerator Considerations

MeV ion beam lithographies are very powerful techniques for 3D direct writing in positive or negative photoresist materials. Nanometer-scale rough structures, or clear areas with straight vertical sidewalls as thin as a few 10's of nm in a resist of a few nm to 100 {mu}m thickness can be made. These capabilities are particularly useful for lithography in cellular- and sub-cellular level biomedical research and technology applications. It can be used for tailor making special structures such as optical waveguides, biosensors, DNA sorters, spotting plates, systems for DNA, protein and cell separation, special cell-growth substrates and microfluidic lab-on-a-chip devices. Furthermore MeV ion beam lithography can be used for rapid prototyping, and also making master stamps and moulds for mass production by hot embossing and nanoimprint lithography. The accelerator requirements for three different high energy ion beam lithography techniques are overviewed. We consider the special requirements placed on the accelerator and how this is achieved for a commercial proton beam writing tool.

43 PARTICLE ACCELERATORS↗

Modeling of Cylindrical Couette Flow of Rarefied Gas. The Case of Rotating Outer Cylinder

The cylindrical Couette flow of a rarefied gas is studied in the case when the outer cylinder is rotating while the inner cylinder is at rest. Velocity, density and temperature profiles are investigated by a Direct Monte Carlo Simulation method and a numerical solution of the Navier-Stokes equations for compressible flow is found. The results obtained by both methods are: in an excellent agreement at a small Knudsen number Kn = 0.02; in a satisfactory agreement at Kn = 0.1 and they vastly differs each other at a moderate Kn = 0.5. The comparison shows that the continuum approach can be used successfully for calculations of non-planar isothermal rarefied gas flows at small Knudsen numbers Kn<0.1. These results are important for applications in non-planar microfluidic problems.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Liquid cell with plasmon lenses for surface enhanced raman spectroscopy.

High-fidelity surface enhanced Raman spectra (SERS) of Rhodamine 6G and 2-mercaptopyrimidine liquid solutions are measured using a microfluidic delivery system constructed on a flat silver substrate. Microscopic plasmon lenses patterned in the silver film focus surface plasmons into a subwavelength spot which yields the light amplification required for SERS. The system provides an efficiency similar to traditional colloidal substrates, and allows multiple sample loading. We find that the main contribution to the spectra comes from the molecules directly attached to the silver surface, which gives strong evidence for the chemical enhancement of SERS.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Axisymmetric oscillation modes of a double droplet system

A double droplet system (DDS) consists of a sessile and a pendant drop that are coupled through a liquid filled cylindrical hole in a plate of thickness d. For a small hole radius R, equilibrium shapes of both drops are sections of spheres. While DDSs have a number of applications in microfluidics, a DDS oscillating about its equilibrium state can be used as a fast focusing liquid lens. Here, a DDS consisting of an isothermal, incompressible Newtonian fluid of constant density p and constant viscosity u that is surrounded by a gas is excited by oscillating in time (a) the pressure in the gas surrounding either drop (pressure excitation), (b) the plate perpendicular to its plane (axial excitation), and (c) the hole radius (radial excitation). In contrast to previous works that assumed transient drop shapes are spherical, they are determined here by simulation and used to identify the natural modes of axisymmetric oscillations from resonances observed during frequency sweeps with DDSs for which the combined volume V of the two drops is less than (4/3)πR 3 . Pressure and axial excitations are found to have identical responses but axial and radial excitations are shown to excite different modes. These modes are compared to those exhibited by single pendant (sessile) drop systems. Specifically, while a single pendant (sessile) drop has one additional oscillation mode compared to a free drop, a DDS is found to exhibit roughly twice as many oscillation modes as a pendant (sessile) drop. The effects of dimensionless volume V/R 3 , dimensionless plate thickness d/R, and Ohnesorge number Oh =μ/√ρRσ , where σ is the surface tension of the DDS-gas interface, on the resonance frequencies are also investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Local x-ray structure analysis of optically manipulated biological micro-objects

X-ray diffraction using micro- and nanofocused beams is well suited for nanostructure analysis at different sites of a biological micro-object. To conduct in vitro studies without mechanical contact, we developed object manipulation by optical tweezers in a microfluidic cell. Here we report x-ray microdiffraction analysis of a micro-object optically trapped in three dimensions. We revealed the nanostructure of a single starch granule at different points and investigated local radiation damage induced by repeated x-ray exposures at the same position, demonstrating high stability and full control of the granule orientation by multiple optical traps.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reversible wettability of electron-beam deposited indium-tin-oxide driven by ns-UV irradiation

Indium tin oxide (ITO) is one of the most widely used semiconductor oxides in the field of organic optoelectronics, especially for the realization of anode contacts. Here the authors report on the control of the wettability properties of ITO films deposited by reactive electron beam deposition and irradiated by means of nanosecond-pulsed UV irradiation. The enhancement of the surface water wettability, with a reduction of the water contact angle larger than 50 deg., is achieved by few tens of seconds of irradiation. The analyzed photo-induced wettability change is fully reversible in agreement with a surface-defect model, and it can be exploited to realize optically transparent, conductive surfaces with controllable wetting properties for sensors and microfluidic circuits.

36 MATERIALS SCIENCE↗

Optical Manipulation of Shape-Morphing Elastomeric Liquid Crystal Microparticles Doped with Gold Nanocrystals

We demonstrate facile optical manipulation of shape of birefringent colloidal microparticles made from liquid crystal elastomers. Using soft lithography and polymerization, we fabricate elastomeric microcylinders with weakly undulating director oriented on average along their long axes. These particles are infiltrated with gold nanospheres acting as heat transducers that allow for an efficient localized transfer of heat from a focused infrared laser beam to a submicrometer region within a microparticle. Photothermal control of ordering in the liquid crystal elastomer using scanned beams allows for a robust control of colloidal particles, enabling both reversible and irreversible changes of shape. Possible applications include optomechanics, microfluidics, and reconfigurable colloidal composites with shape-dependent self-assembly.

36 MATERIALS SCIENCE↗

High-performance laser processing using manipulated ultrafast laser pulses

We employ manipulated ultrafast laser pulses to realize microprocessing with high-performance. Efficient microwelding of glass substrates by irradiation by a double-pulse train of ultrafast laser pulses is demonstrated. The bonding strength of two photostructurable glass substrates welded by double-pulse irradiation was evaluated to be 22.9 MPa, which is approximately 22% greater than that of a sample prepared by conventional irradiation by a single pulse train. Additionally, the fabrication of hollow microfluidic channels with a circular cross-sectional shape embedded in fused silica is realized by spatiotemporally focusing the ultrafast laser beam. We show both theoretically and experimentally that the spatiotemporal focusing of ultrafast laser beam allows for the creation of a three-dimensionally symmetric spherical peak intensity distribution at the focal spot.

36 MATERIALS SCIENCE↗

The effect of PECVD plasma decomposition on the wettability and dielectric constant changes in silicon modified DLC films for potential MEMS and low stiction applications

We have carried out investigations aimed at understanding the mechanism responsible for a water contact angle increase of up to ten degrees and a decrease in dielectric constant in silicon modified hydrogenated amorphous carbon films compared to unmodified hydrogenated amorphous carbon films. Our investigations based on surface chemical constituent analysis using Raman spectroscopy, x-ray photoelectron spectroscopy (XPS), SIMS, FTIR, contact angle / surface energy measurements and spectroscopic ellipsometry suggests the presence of hydrophobic chemical entities on the surface of the films. This observation is consistent with earlier theoretical plasma chemistry predictions and observed Raman peak shifts in the films. These surface hydrophobic entities also have a lower polarizability than the bonds in the un-modified films thereby reducing the dielectric constant of the silicon modified films measured by spectroscopic ellipsometry. Ellipsometric dielectric constant measurement is directly related to the surface energy through Hamaker's constant. Our current finding is expected to be of benefit to understanding stiction, friction and lubrication in areas that range from nano-tribology to microfluidics.

36 MATERIALS SCIENCE↗

Nondestructive millimeter wave imaging and spectroscopy using dielectric focusing probes

A tool for interrogating objects over a wide band of frequencies with subwavelength resolution at small standoff distances (near field region) in the transmission mode using a single source and detector measurement setup in the millimeter wave band is presented. The design utilizes optics like principles for guiding electromagnetic millimeter waves from large cross-sectional areas to considerably smaller sub-wavelength areas. While plano-convex lenses can be used to focus waves to a fine resolution, they usually require a large stand-off distance thus resulting in alignment and spacing issues. The design procedure and simulation analysis of the focusing probes are presented in this study along with experimental verification of performance and imaging and spectroscopy examples. Nondestructive evaluation will find benefit from such an apparatus including biological tissue imaging, electronic package integrity testing, composite dielectric structure evaluation for defects and microfluidic sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗