Search NASA⌕ Search

SEARCH · Search NASA

Results for “Module Reliability”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

High Energy Yield Distributed Architecture for Large Commercial and Utility-Scale PV Systems

Photovoltaic energy has come a long way from its early days when small cells were fabricated in the labs in the early 50s. While it took a long time for PV modules to mature into what we now see in the market and in rooftops across the world, the power electronics has been lagging behind & was always the weakest point in the PV plant, being responsible for the majority of failures & robbing the PV plants of their full potential by losing precious Watts in the process of converting power from DC to AC. Since the early days of PV power, it has been recognized that the modules need to operate at their maximum power point in order to extract as much power as is available from the PV modules at a given time of day and year. Numerous maximum power point devices were developed to do just this. While effective at extracting as much power as they can, soon after there was a realization that in a PV installation where a central inverter is used, many losses occur, hence energy yield losses. This has led to thinking about alternative architectures where the maximum power point tracking (MPPT) is performed much closer to the modules rather than at a central inverter. Several architectures were proposed ranging from a microinverter, microconverter, string inverter, string optimizer, and to a multi-string inverter or optimizer. While these architectures promise to increase the energy yield by 5% to 25% (depending where MPPT is located), & recovering losses due to shading, soiling, mismatch … there were no real studies and implementations in the field to corroborate these numbers. The program that GE Global Research proposed & received funding for is aimed at a type of distributed architectures, namely the dc architectures where only the MPPT function is distributed across the PV plant. Further, the project is concerned with choosing the right architecture for large scale commercial & utility scale plants but not residential installations. Findings from Task 1- Define Requirements & Develop Architecture- showed that for large scale commercial & utility PV plants, locating the MPPT at the string level with a string size of >3kW is the most cost effective solution & that the increase in energy yield of 6% to 8% is more than enough to make up for the increased cost due to additional power electronics. Our study also shows that in addition to an increase in energy yield, having a dc/dc converter at the string level brings additional benefits such as increased array visibility, allowing for increased monitoring and diagnostics; high and constant dc bus voltage which allows for reducing losses further and optimizing the inverter; and ability to detect ground and arc faults. Task 2 focused on designing a suitable dc/dc converter that meets the requirements defined in Task 1: Efficiency, Cost, & Reliability. For this task, we surveyed and simulated all candidate topologies known by the practitioners in the field. We also generated a novel topology, simulated it, & compared it to existing topologies. Our novel topology being a partial power processing converter came out on top due to its simplicity (fewer parts), it high efficiency, its reliability, and its lower cost. In the remaining tasks of the project, we built the hardware, tested it first in the lab, then in the field and once we worked out all the bugs and issues and were confident our system was robust, we installed it on the rooftop and started collecting the data by mid-Q3 2012. We shared our work with the scientific community in the form of conference & Journal papers, hence contributing to the general understanding of this technology area. The methods, techniques, and hardware developed under this project have all been tested in the field over long periods of time, and under many conditions and have been shown to be robust and reliable. The converters built and developed under this program have been in operation in the field since mid-June 2012, and no hardware failures have been recorded. While some software issues have been seen, none have been showstoppers. The cost analysis of the hardware showed that it meets the cost target set in the requirement document developed in the trade-off study. Improving the performance of solar installations for commercial and utility scale plants contributes to reducing their cost of ownership, hence spreading them to a larger section of the society and making them affordable. Our project contributed to the understanding of the distributed architectures, showed that PV plants’ cost of electricity can be reduced through additional power electronics which allows for harvesting more energy from the plant. When the project started in 2009, the cost of PV energy was still high, hence there was a real need to increase the energy yield, hence reduce the levelized cost of electricity (LCOE). While costs have come down significantly, the need for increasing the energy yield is still relevant, hence the project results, hardware, and techniques developed are still pertinent today. By taking this project from concept to rooftop demonstration, we showed that the technology is mature enough, robust enough, and has the potential to be used by many more customers, hence benefiting the public in general through the spread of PV energy, which ultimately contributes to reducing our dependency on fossil fuel, improving the environment, and creating more jobs.

14 SOLAR ENERGY↗

Fully Automated Simultaneous Integrated Boosted-Intensity Modulated Radiation Therapy Treatment Planning Is Feasible for Head-and-Neck Cancer: A Prospective Clinical Study

Purpose: To prospectively determine whether overlap volume histogram (OVH)-driven, automated simultaneous integrated boosted (SIB)-intensity-modulated radiation therapy (IMRT) treatment planning for head-and-neck cancer can be implemented in clinics. Methods and Materials: A prospective study was designed to compare fully automated plans (APs) created by an OVH-driven, automated planning application with clinical plans (CPs) created by dosimetrists in a 3-dose-level (70 Gy, 63 Gy, and 58.1 Gy), head-and-neck SIB-IMRT planning. Because primary organ sparing (cord, brain, brainstem, mandible, and optic nerve/chiasm) always received the highest priority in clinical planning, the study aimed to show the noninferiority of APs with respect to PTV coverage and secondary organ sparing (parotid, brachial plexus, esophagus, larynx, inner ear, and oral mucosa). The sample size was determined a priori by a superiority hypothesis test that had 85% power to detect a 4% dose decrease in secondary organ sparing with a 2-sided alpha level of 0.05. A generalized estimating equation (GEE) regression model was used for statistical comparison. Results: Forty consecutive patients were accrued from July to December 2010. GEE analysis indicated that in APs, overall average dose to the secondary organs was reduced by 1.16 (95% CI = 0.09-2.33) with P=.04, overall average PTV coverage was increased by 0.26% (95% CI = 0.06-0.47) with P=.02 and overall average dose to the primary organs was reduced by 1.14 Gy (95% CI = 0.45-1.8) with P=.004. A physician determined that all APs could be delivered to patients, and APs were clinically superior in 27 of 40 cases. Conclusions: The application can be implemented in clinics as a fast, reliable, and consistent way of generating plans that need only minor adjustments to meet specific clinical needs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Optimizing Sensor Count and Placement to Detect Bond Wire Lift-Offs and Surface Defects in High-Power IGBT Modules Using Low-Cost Piezo-Electric Resonators

This manuscript presents the most recent results and findings to identify bond wire lift-offs and surface defects in high-power isolated gate bipolar junction transistor (IGBT) modules. The authors of this manuscript formerly proposed a low-cost, piezoelectric resonator-based measurement unit to detect bond wire related degradation in larger IGBT modules. Since high-power IGBT modules are expensive, it was apparent that evaluating our proposed method by inducing controlled damage to fresh (new) IGBTs may not be cost-effective especially when multiple sets of data need to be captured by inducing damage to different levels. In order to overcome this limitation, IGBT bond wires have been mimicked using a 3D printed enclosure, a PCB, and copper wires with dimensions very closely resembling a real IGBT. Using this method, multiple test devices can be built at the cost of a real IGBT, and the proposed technique could be fine-tuned without damaging expensive, real IGBTs. Our recent findings can be used to determine real IGBT degradation and bond wire lift-offs using only two sensors, as opposed to six transducers used in the first iteration of the setup. In addition to optimizing the sensor count, we have also identified the best possible locations of these sensors by attempting multiple placements inside the IGBT casing.

condition monitoring↗

SU-E-T-184: Clinical VMAT QA Practice Using LINAC Delivery Log Files

Purpose: To evaluate the accuracy of volumetric modulated arc therapy (VMAT) treatment delivery dose clouds by comparing linac log data to doses measured using an ionization chamber and film. Methods: A commercial IMRT quality assurance (QA) process utilizing a DICOM-RT framework was tested for clinical practice using 30 prostate and 30 head and neck VMAT plans. Delivered 3D VMAT dose distributions were independently checked using a PinPoint ionization chamber and radiographic film in a solid water phantom. DICOM RT coordinates were used to extract the corresponding point and planar doses from 3D log file dose distributions. Point doses were evaluated by computing the percent error between log file and chamber measured values. A planar dose evaluation was performed for each plan using a 2D gamma analysis with 3% global dose difference and 3 mm isodose point distance criteria. The same analysis was performed to compare treatment planning system (TPS) doses to measured values to establish a baseline assessment of agreement. Results: The mean percent error between log file and ionization chamber dose was 1.0%±2.1% for prostate VMAT plans and −0.2%±1.4% for head and neck plans. The corresponding TPS calculated and measured ionization chamber values agree within 1.7%±1.6%. The average 2D gamma passing rates for the log file comparison to film are 98.8%±1.0% and 96.2%±4.2% for the prostate and head and neck plans, respectively. The corresponding passing rates for the TPS comparison to film are 99.4%±0.5% and 93.9%±5.1%. Overall, the point dose and film data indicate that log file determined doses are in excellent agreement with measured values. Conclusion: Clinical VMAT QA practice using LINAC treatment log files is a fast and reliable method for patient-specific plan evaluation.

60 APPLIED LIFE SCIENCES↗

SU-E-T-790: Validation of 4D Measurement-Guided Dose Reconstruction (MGDR) with OCTAVIUS 4D System

Purpose: To validate the MGDR of OCTAVIUS 4D system (PTW, Freiburg, Germany) for quality assurance (QA) of volumetric-modulated arc radiotherapy (VMAT). Methods: 4D-MGDR measurements were divided into two parts: 1) square fields from 2×2 to 25×25 cm{sup 2} at 0°, 10° and 45° gantry, and 2) 8 VMAT plans (5 nasopharyngeal and 3 prostate) collapsed to gantry 40° in QA mode in Monaco v5.0 (Elekta, CMS, Maryland Heights, MO) were delivered on the OCTAVIUS 4D phantom with the OCTAVIUS 1500 detector plane perpendicular to either the incident beam to obtain the reconstructed dose (OCTA4D) or the 0° gantry axis to obtain the raw doses (OCTA3D) in Verisoft 6.1 (PTW, Freiburg, Germany). Raw measurements of OCTA3D were limited to < 45° gantry to avoid >0.5% variation of detector angular response with respect to 0° gantry as determined previously. Reconstructed OCTA4D and raw OCTA3D doses for all plans were compared at the same detector plane using γ criteria of 2% (local dose)/2mm and 3%/3mm criteria. Results: At gantry 0° and 10°, the γ results for all OCTA4D on detector plane coinciding with OCTA3D were over 90% at 2%/2mm except for the largest field (25×25 cm{sup 2} ) showing >88%. For square field at 45° gantry, γ passing rate is > 90% for fields smaller than 15x 15cm2 but < 80% for field size of 20 x20 cm{sup 2} upward. For VMAT, γ results showed 94% and 99% passing rate at 2%/2mm and 3%/3mm, respectively. Conclusion: OCTAVIUS 4D system has compromised accuracy in reconstructing dose away from the central beam axis, possibly due to the off-axis softening correction and errors of the percent depth dose data necessary as input for MGDR. Good results in VMAT delivery suggested that the system is relatively reliable for VMAT with small segments.

60 APPLIED LIFE SCIENCES↗

Design, characterization and indoor validation of the optical soiling detector “DUSST”

Nowadays, photovoltaic (PV) technology has reached a high level of maturity in terms of module efficiency and cost competitiveness in comparison with other energy technologies. As PV has achieved high levels of deployment, the development of devices that can help to reduce PV operation and maintenance costs has become a priority. Soiling can be cause of significant losses in certain PV plants and its detection has become essential to ensure a correct mitigation. For this reason, accurate and low-cost monitoring devices are needed. While soiling stations have been traditionally employed to measure the impact of soiling, their high cost and maintenance have led to the development of innovative low-cost optical sensors, such as the device presented in this work and named “DUSST” (Detector Unit for Soiling Spectral Transmittance). The thermal characterization of DUSST’s components and the methodology used to predict soiling transmittance losses are presented in this study. The results demonstrate that the losses can be predicted with an error lower than 1.4%. The method has been verified with an experimental campaign with naturally soiled coupons exposed outdoors in Jaén, Spain.

14 SOLAR ENERGY↗

Towards Validation of Advanced Accelerated Stress Testing Protocols through Failure Analysis and Materials Characterization

As the lifetime of photovoltaic modules increases toward the goal of 50 years, accelerated stress testing is critical to assessing the viability of newer, improved, and often cheaper materials in the field. However, the validation of accelerated testing to reproduce field failure has remained elusive. The recent developments of more advanced stress testing protocols utilizing sequential and combined stressors have provided another opportunity for validation. Using a suite of mechanical, chemical, and structural characterization methods we report the development of our approach using a known bad backsheet “AAA.” We then apply this approach to PVDF-based backsheets to further confirm the generalizability of this approach. The outcome of this work is two-fold: (1) validation of advanced accelerated testing protocols which will enable the prediction of field failures in new materials, and (2) deeper insights into the degradation mechanisms observed through the extensive characterization allowing for improved materials engineering and development.

accelerated aging↗

Evaluation of clinical IMRT treatment planning using the GATE Monte Carlo simulation platform for absolute and relative dose calculations

Purpose: The objective of this study was to evaluate and validate the use of the Geant4 application for emission tomography (GATE) Monte Carlo simulation platform for clinical intensity modulated radiotherapy (IMRT) dosimetry studies. Methods: The first step consisted of modeling a 6 MV photon beam linear accelerator (LINAC), with its corresponding validation carried out using percent depth dose evaluation, transverse profiles, tissue phantom ratio, and output factor on water phantom. The IMRT evaluation was performed by comparing simulation and measurements in terms of absolute and relative doses using IMRT dedicated quality assurance phantoms considering seven different patient datasets. Results: Concerning the LINAC simulated model validation tissue phantom ratios at 20 and 10 cm in water TPR{sub 10}{sup 20} obtained from GATE and measurements were 0.672 {+-} 0.063 and 0.675, respectively. In terms of percent depth dose and transverse profiles, error ranges were, respectively: 1.472%{+-} 0.285% and 4.827%{+-} 1.323% for field size of 4 Multiplication-Sign 4, 5 Multiplication-Sign 5, 10 Multiplication-Sign 10, 15 Multiplication-Sign 15, 20 Multiplication-Sign 20, 25 Multiplication-Sign 25, 30 Multiplication-Sign 30, and 40 Multiplication-Sign 40 cm{sup 2}. Most errors were observed at the edge of radiation fields because of higher dose gradient in these areas. Output factors showed good agreement between simulation and measurements with a maximum error of 1.22%. Finally, for IMRT simulations considering seven patient datasets, GATE provided good results with a relative error of 0.43%{+-} 0.25% on absolute dose between simulated and measured beams (measurements at the isocenter, volume 0.125 cm{sup 3}). Planar dose comparisons were also performed using gamma-index analysis. For the whole set of beams considered the mean gamma-index value was 0.497 {+-} 0.152 and 90.8%{+-} 3.6% of the evaluated dose points satisfied the 5%/ 4 mm criterion. Conclusions: These results show that GATE allows reliable simulation of complex beams in radiotherapy after an accurate LINAC modeling is validated. A simple cross-calibration procedure proposed in this work allows obtaining absolute dose values even in complex fields.

60 APPLIED LIFE SCIENCES↗

Oxygen-Plasma-Induced Hetero-Interface NiFe2O4/NiMoO4 Catalyst for Enhanced Electrochemical Oxygen Evolution

The electrolysis of water to produce hydrogen is an effective method for solving the rapid consumption of fossil fuel resources and the problem of global warming. The key to its success is to design an oxygen evolution reaction (OER) electrocatalyst with efficient conversion and reliable stability. Interface engineering is one of the most effective approaches for adjusting local electronic configurations. Adding other metal elements is also an effective way to enrich active sites and improve catalytic activity. Herein, high-valence iron in a heterogeneous interface of NiFe 2 O 4 /NiMoO 4 composite was obtained through oxygen plasma to achieve excellent electrocatalytic activity and stability. In particular, 270 mV of overpotential is required to reach a current density of 50 mA cm -2 , and the overpotential required to reach 500 mA cm -2 is only 309 mV. The electron transfer effect for high-valence iron was determined by X-ray photoelectron spectroscopy (XPS). The fast and irreversible reconstruction and the true active species in the catalytic process were identified by in situ Raman, ex situ XPS, and ex situ transmission electron microscopy (TEM) measurements. This work provides a feasible design guideline to modify electronic structures, promote a metal to an active oxidation state, and thus develop an electrocatalyst with enhanced OER performance.

36 MATERIALS SCIENCE↗

SU-D-19A-03: Monte Carlo Investigation of the Mobetron to Perform Modulated Electron Beam Therapy

Purpose: Modulated electron radiotherapy (MERT) has been proposed as a mean of delivering conformal dose to shallow tumors while sparing distal structures and surrounding tissues. In intraoperative radiotherapy (IORT) utilizing Mobetron, an applicator is placed as closely as possible to the suspected cancerous tissues to be treated. In this study we investigate the characteristics of Mobetron electron beams collimated by an in-house prospective electron multileaf collimator (eMLC) and its feasibility for MERT. Methods: IntraOp Mobetron™ dedicated to perform radiotherapy during surgery was used in the study. It provides several energies (6, 9 and 12 MeV). Dosimetry measurements were performed to obtain percentage depth dose curves (PDD) and profiles for a 10-cm diameter applicator using the PTW MP3/XS 3D-scanning system and the semiflex ion chamber. MCBEAM/MCSIM Monte Carlo codes were used for the treatment head simulation and phantom dose calculation. The design of an electron beam collimation by an eMLC attached to the Mobetron head was also investigated using Monte Carlo simulations. Isodose distributions resulting from eMLC collimated beams were compared to that collimated using cutouts. The design for our Mobetron eMLC is based on our previous experiences with eMLCs designed for clinical linear accelerators. For Mobetron the eMLC is attached to the end of a spacer-mounted rectangular applicator at 50 cm SSD. Steel will be used as the leaf material because other materials would be toxic and will not be suitable for intraoperative applications. Results: Good agreement (within 2%) was achieved between measured and calculated PDD curves and profiles for all available energies. Dose distributiosn provided by the eMLC showed reasonable agreement (∼3%/1mm) with those obtained by conventional cutouts. Conclusion: Monte Carlo simulations are capable of modeling Mobetron electron beams with a reliable accuracy. An eMLC attached to the Mobteron treatment head will allow better treatment options with those machines.

60 APPLIED LIFE SCIENCES↗

Use of indentation to study the degradation of photovoltaic backsheets

The ability of electrical insulating materials within a module to act as insulators is a key safety requirement for photovoltaic (PV) technology. Presently, however, the durability of backsheets may not be readily assessed. For example, the mechanical tensile test continues to be developed, and its use has not been validated such that a technically based pass/fail criteria may be established. This study examines the use of simple indentation methods, including durometer hardness and instrumented indentation, as a means to quantitively assess the degradation of PV backsheets. Characteristics including: hardness, modulus, load/displacement profile, creep hold response, and residual impression are explored in an empirical study. Glass/encapsulant/backsheet mini-modules constructed using backsheets including: polyamide (PA), poly(ethylene terephthalate) (PET), polyvinyl fluoride (PVF) laminate ('TPE'), and polyvinylidene fluoride (PVDF) were examined. An M-type durometer as well as Berkovich and cube-corner tips were used in the indentation experiments. Additional characterizations were performed to interpret the indentation measurements including: surface roughness measurements using atomic force microscopy (AFM), a chemical integrity study using Fourier-transform infrared spectroscopy (FTIR), and phase-transition measurements using differential scanning calorimetry (DSC). The results are analyzed in the context of the combined accelerated stress test (C-AST) also explored in this study. Instrumented indentation (i.e., using a Berkovich tip) was able to distinguish between backsheets and quantify the effects of accelerated testing (including up to 60%, 25%, and 20% change in hardness, modulus, and creep displacement, respectively). The embrittlement of the backsheets was not readily assessable using cube-corner indentation. Cracking of the known-bad polyamide backsheet was observed from the C-AST, which was not observed to result from steady state UV weathering.

14 SOLAR ENERGY↗

Restoration Hydro: A Watershed Approach to Standard Modular New Hydropower

The objectives of FOA DE- FOA-0001836- “Standard Modular Hydropower” included designing a standardized, modular, and environmentally compatible hydropower schematic for implementation in greenfield sites that generate up to 10 MW of capacity. Utilizing funds competitively awarded under DOE’s Water Power Technologies Office, the Natel Energy team developed a concept for modular new stream reach (NSR) hydropower that incorporates multi species upstream and downstream fish passage, improved river channel connectivity, and recreational modules. The in-stream design of the collective modules minimized site specific design and maximized the opportunities for modularity. Financial data was also presented using actual costs from regional suppliers, with figures provided in 2022 dollars. While the project team did not address potential permitting process improvements, the site selection criteria did consider established barriers to hydropower development such as tribal and preserved lands, interconnection proximity, and endangered species to exclude or deprioritize. The project’s design schematic met the objectives of the FOA, and presented a unique solution that targets alluvial pockets as natural features for sustainable development. Natel’s concept also incorporated the company's fish-safe Restoration Hydro Turbine for safe downstream passage, while featuring a rock arch that integrates fish passage, water, recreation, and grade control modules (including sediment). Alignment with the Department of Energy Office of Energy Efficiency and Renewable Energy (EERE) “Innovative Design Concepts for Standard Modular Hydropower and Pumped-Storage Hydropower” Program: According to the Hydropower Vision (DOE, 2016), approximately 16 GW of hydropower growth is possible with the development of technology solutions that balance efficiency, economics, and environmental sustainability. The desired outcome of the SMH program is transformational innovation specifically in the site identification, conceptual, and detailed design phases of technology development lifecycles (DOE, 2018). In developing the SMH design schematic, the team aimed to address the opportunities outlined in the Vision through an inverted design philosophy; rather than singularly prioritizing efficiency and power production, the team focused on integrating hydropower with restoration of degraded streams to optimal ecosystem function and provision of exceptional recreation value as design criteria. To achieve this, Restoration Hydro incorporates the principles of nature-based engineering (WWAP, 2018) and biomimicry (Biomimicry NL.) to strategically deploy complementary combinations of permanent, semi-permanent, and ephemeral low-head structures - such as natural and engineered log jams - that harness geomorphological and hydrological processes at the landscape-scale. Primary applications of Restoration Hydro include: 1) restoration of degraded watersheds’ natural ecological function and enhancement of hydrological connectivity; and 2) creation of associated co-benefits to hydro production, including increased groundwater recharge, improved sediment transport and management, improved water security and water quality. Restoration Hydro projects build upon proven watershed restoration engineering techniques by integrating hydropower turbines into low-head structures using innovative and evolving civil works concepts that facilitate fish and sediment passage, and in some cases create additional revenue-generating recreational opportunities. Powering low-head structures creates a directly monetizable layer of economic value in the form of flexible, reliable, renewable energy on top of the already high-value water, environmental and recreational benefits of watershed and river restoration. The approach aims to create a virtuous, self-reinforcing cycle whereby Restoration Hydro projects support the scaling of ecosystem restoration activities, creating a water-energy-carbon multiplier effect that, through the principles of adaptive change management: 1) improves the resilience of landscapes and downstream population centers for changing hydrological cycles; 2) creates a reliable energy resource that facilitates the integration of intermittent renewable power sources into grids; and 3) supports climate change mitigation through grid decarbonization and enhanced ecosystem carbon capture and retention.

13 HYDRO ENERGY↗

Selection of optimal wavelengths for optical soiling modelling and detection in photovoltaic modules

Soiling impacts the photovoltaic (PV) module performance by decreasing the amount of light reaching the photovoltaic cells and by changing their external spectral response. Currently, the soiling monitoring market is moving toward optical sensors that measure transmittance or reflectance, rather than directly measuring the impact of soiling on the performance of photovoltaic modules. These sensors, which use a single optical measurement, are not able to correct the soiling losses that depend on the solar irradiance spectra and on the spectral response of the monitored PV material. This work investigates methods that can improve the optical detection of soiling by extracting the full soiling spectrum profiles using only two or three monochromatic measurements. Spectral transmittance data, measured with a spectrophotometer and collected during a 46-week experimental soiling study carried out in Jaén, Spain, was analysed in this work. The use of a spectral profile for the hemispherical transmittance of soiled PV glass is found to significantly improve the soiling detection, returning the lowest errors independently of the PV materials and irradiance conditions. In addition, this work shows that it is also possible to select the measurement wavelengths to minimize the soiling loss detection error depending on the monitored PV semiconductor material (silicon, CdTe, a-Si, CIGS and a representative perovskite). The approaches discussed in this work are also found to be more robust to potential measurement errors compared to single wavelength measurement techniques.

14 SOLAR ENERGY↗

PV encapsulant formulations and stress test conditions influence dominant degradation mechanisms

Polyethylene-based poly(ethylene-co-vinyl acetate) (EVA), polyolefin elastomer (POE), and thermoplastic polyolefin (TPO) are common polymer candidates for photovoltaic (PV) module encapsulants. The choice of encapsulant must be carefully considered in novel module designs, such as bifacial glass/glass laminates, to limit performance degradation through loss of optical transmittance, mechanical integrity, and corrosion - as well as potential-induced degradation. Encapsulant quality and resilience against environmental stressors are readily influenced by the additives in the encapsulant formulation. Here, we show that, the changes in optical transmittance after UV aging result from the discoloration caused by interactions between additives, and optical scattering from changes in the polymer crystal structure. We observed competing cross-linking and chain scission mechanisms, with their kinetics influenced by the presence of oxygen and elevated temperatures. Increasing chamber temperatures from 55 °C to 85 °C during the UV stress test amplified encapsulant discoloration and promoted polymer cross-linking, causing severe, irreversible damage that remains to be proven field relevant. Damp heat aging was found to be insufficient to produce significant encapsulant degradation; however, combining stress tests sequentially allowed detection of further degradation beyond the limitations of the damp heat test alone. Appropriate degradation screening methods are necessary to uncover potential encapsulant weaknesses.

14 SOLAR ENERGY↗

Proposed linear energy transfer areal detector for protons using radiochromic film

Radiation therapy depends on predictably and reliably delivering dose to tumors and sparing normal tissues. Protons with kinetic energy of a few hundred MeV can selectively deposit dose to deep seated tumors without an exit dose, unlike x-rays. The better dose distribution is attributed to a phenomenon known as the Bragg peak. The Bragg peak is due to relatively high energy deposition within a given distance or high Linear Energy Transfer (LET). In addition, biological response to radiation depends on the dose, dose rate, and localized energy deposition patterns or LET. At present, the LET can only be measured at a given fixed point and the LET spatial distribution can only be inferred from calculations. The goal of this study is to develop and test a method to measure LET over extended areas. Traditionally, radiochromic films are used to measure dose distribution but not for LET distribution. We report the first use of these films for measuring the spatial distribution of the LET deposited by protons. The radiochromic film sensitivity diminishes for large LET. A mathematical model correlating the film sensitivity and LET is presented to justify relating LET and radiochromic film relative sensitivity. Protons were directed parallel to radiochromic film sandwiched between solid water slabs. This study proposes the scaled-normalized difference (SND) between the Treatment Planning system (TPS) and measured dose as the metric describing the LET. The SND is correlated with a Monte Carlo (MC) calculation of the LET spatial distribution for a large range of SNDs. A polynomial fit between the SND and MC LET is generated for protons having a single range of 20 cm with narrow Bragg peak. Coefficients from these fitted polynomial fits were applied to measured proton dose distributions with a variety of ranges. An identical procedure was applied to the protons deposited from Spread Out Bragg Peak and modulated by 5 cm. Gamma analysis is a method for comparing the calculated LET with the LET measured using radiochromic film at the pixel level over extended areas. Failure rates using gamma analysis are calculated for areas in the dose distribution using parameters of 25% of MC LET and 3 mm. The processed dose distributions find 5%–10% failure rates for the narrow 12.5 and 15 cm proton ranges and 10%–15% for proton ranges of 15, 17.5, and 20 cm and modulated by 5 cm. It is found through gamma analysis that the measured proton energy deposition in radiochromic film and TPS can be used to determine LET. This modified film dosimetry provides an experimental areal LET measurement that can verify MC calculations, support LET point measurements, possibly enhance biologically based proton treatment planning, and determine the polymerization process within the radiochromic film.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-269: Quality Assurance of Spine Volumetric Modulated Arc Therapy with Flattening Filter Free Beams Using Gafchromic EBT3 Films

Purpose: We implemented the Gafchromic film-based patient specific QA of volumetric modulated arc therapy (VMAT) with flattening-filter free (FFF) beams for spine metastases and validated the accuracy of fast arc delivery. Methods: EBT3 films and a homemade cylindrical QA phantom were employed for dosimetric verification of VMATs. For 14 FFF VMAT plans (10 with 10-MV FFF beams and 4 with 6-MV FFF beams), the doses were recalculated on the phantom and delivered by a TrueBeam STx accelerator equipped with a high-definition 120 leaf MLC. The EBT3 films were scanned using an Epson 10000XL scanner through the FilmQA Pro software. All the irradiated film images were converted to dose map using a calibration response curve. The resulting dose map of film measurement was compared with treatment plan and evaluated using gamma analysis with dose tolerance of 2% within 2 mm. In addition, the point-dose measurement in the phantom using an ion chamber was evaluated as a reference in a ratio of measured and planned doses. Results: The gamma pass rates averaged over all FFF plans for composite-field measurements were 96.0 ± 3.6% (88.9%–99.5%). When adopting a tolerance level of 3% - 3 mm, the gamma pass rates were improved with the ranges from 98% to 100%. In addition, dose profiles and dose distributions showed that spinal cord was protected by the rapid dose fall-off and by delivering the treatment with high precision. In point-dose measurements, the average differences between the measured and planned doses were 0.5% ± 1.0% of the prescription dose. Conclusion: We demonstrated that Gafchromic EBT3 film would be an effective patient-specific QA tool, especially for VMAT of spine SBRT with treatment of small fields and highly gradient dose distributions. The results of film QA verified that the dosimetric accuracy of spine SBRT utilizing RapidArc with FFF beams in our institution is reliable.

60 APPLIED LIFE SCIENCES↗

PV Performance Modeling and Stakeholder Engagement (Final Technical Report)

This core capability project’s objective is to increase the value of photovoltaic (PV) performance models by improving their functionality, demonstrating, and quantifying their validity, and offering a wide range of stakeholder engagement opportunities. In FY22-24, we developed new and improved modeling algorithms and functions to represent PV performance more accurately in a variety of environments and conditions. The “Model parameter toolkit” was developed and includes functions to translate between different module temperature models, incidence angle modifier models, and single-diode models. A new modeling capability named “PV Atlas” was also developed leveraging Sandia’s High Performance Computing resources. This capability allows us to investigate several questions and provide climate-specific best practices and geographic data files; all these are hosted on an interactive website on Sandia’s GitHub and can be used for training, system optimization, or to provide best practices for uncertainty reduction. For model validation, we published high-quality PV performance, and weather data; these data are well documented, filtered, and processed for quality and include examples on how to run PV simulations. We also developed well documented, standardized methods for validating PV models and ran independent model validation and 2 blind modeling intercomparisons engaging with 49 organizations from 17 countries. We co-led and contributed to a growing, well documented and maintained suite of open-source functions for PV modeling (i.e., the pvlib-python) and we outreached to the PV modeling stakeholders via the PVPMC workshops and web resources. In addition, this project supported US representation and leadership for the International Energy Agency (IEA) PVPS Task 13; specifically, members of our team led and supported 3 subtasks on: 1) Best practices for the optimization of bifacial photovoltaic tracking, 2) Extreme weather events and their multiple impact on PV power plants: Risks, failure mechanisms and mitigation strategies, and 3) Best practice guidelines for the use of economic and technical Key Performance Indicators (KPIs). This project resulted in the publications of 14 peer reviewed journal papers, 37 conference presentations, 6 SAND reports, 5 public datasets and 6 new webpages on the PVPMC website. It supported the release of 13 pvlib-python versions where 28 enhancements were from this PV Performance Modeling project. We co-organized 5 PVPMC workshops in FY22-24 with the participation of 214 unique institutions and around 700 participants. The PVPMC website was redesigned, and its reliability was improved; it receives over 50,000 visitors/year from 202 unique countries.

14 SOLAR ENERGY↗

Inhibitory effects of herbal constituents on P-glycoprotein in vitro and in vivo: Herb–drug interactions mediated via P-gp

Modulation of drug transporters via herbal medicines which have been widely used in combination with conventional prescription drugs may result in herb–drug interactions in clinical practice. The present study was designed to investigate the inhibitory effects of 50 major herbal constituents on P-glycoprotein (P-gp) in vitro and in vivo as well as related inhibitory mechanisms. Among these herbal medicines, four constituents, including emodin, 18β-glycyrrhetic acid (18β-GA), dehydroandrographolide (DAG), and 20(S)-ginsenoside F{sub 1} [20(S)-GF{sub 1}] exhibited significant inhibition (> 50%) on P-gp in MDR1-MDCKII and Caco-2 cells. Emodin was the strongest inhibitor of P-gp (IC{sub 50} = 9.42 μM), followed by 18β-GA (IC{sub 50} = 21.78 μM), 20(S)-GF{sub 1} (IC{sub 50} = 76.08 μM) and DAG (IC{sub 50} = 77.80 μM). P-gp ATPase activity, which was used to evaluate the affinity of substrates to P-gp, was stimulated by emodin and DAG with K{sub m} and V{sub max} values of 48.61, 29.09 μM and 71.29, 38.45 nmol/min/mg protein, respectively. However, 18β-GA and 20(S)-GF{sub 1} exhibited significant inhibition on both basal and verapamil-stimulated P-gp ATPase activities at high concentration. Molecular docking analysis (CDOCKER) further elucidated the mechanism for structure–inhibition relationships of herbal constituents with P-gp. When digoxin was co-administered to male SD rats with emodin or 18β-GA, the AUC{sub 0−t} and Cmax of digoxin were increased by approximately 51% and 58%, respectively. Furthermore, 18β-GA, DAG, 20(S)-GF{sub 1} and Rh{sub 1} at 10 μM significantly inhibited CYP3A4/5 activity, while emodin activated the metabolism of midazolam in human liver microsomes. In conclusion, four herbal constituents demonstrated inhibition of P-gp to specific extents in vitro and in vivo. Taken together, our findings provided the basis for the reliable assessment of the potential risks of herb–drug interactions in humans. - Highlights: • Emodin, 18β-GA, DAG, and 20(S)-GF{sub 1} significantly inhibited P-gp in vitro. • P-gp ATPase activity was stimulated by emodin and DAG. • 18β-GA and 20(S)-GF{sub 1} exhibited significant inhibition on P-gp ATPase activity. • Molecular docking analysis elucidated the SAR of herbal constituents with P-gp. • Pretreatment with emodin or 18β-GA increased the AUC and Cmax of digoxin in vivo.

60 APPLIED LIFE SCIENCES↗