Search NASA⌕ Search

SEARCH · Search NASA

Results for “NEUTRON SCIENCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Ship Effect Measurements With Fiber Optic Neutron Detector

The main objectives of this research project was to assemble, operate, test and characterize an innovatively designed scintillating fiber optic neutron radiation detector manufactured by Innovative American Technology with possible application to the Department of Homeland Security screening for potential radiological and nuclear threats at US borders (Kouzes 2004). One goal of this project was to make measurements of the neutron ship effect for several materials. The Virginia State University DOE FaST/NSF summer student-faculty team made measurements with the fiber optic radiation detector at PNNL above ground to characterize the ship effect from cosmic neutrons, and underground to characterize the muon contribution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technological Features of Irradiation of Sip{sup +}-n-n{sup +} Diodes with Electrons at Elevated Temperatures

The behavior of the lifetime of nonequilibrium charge carriers {tau}{sub p}, the reverse current I{sub R}, and the forward-voltage drop U{sub F} in electron-irradiated (E{sub irr} = 6 MeV) commercial p{sup +}-n-n{sup +} diodes at irradiation temperatures in the range of T{sub irr} = 20-400 Degree-Sign C is studied. Studies have been performed for samples fabricated on a single-crystal Si substrate either doped with phosphorus in the course of growth by the Czochralski method (Cz-n-Si:P) or doped with phosphorus by nuclear transmutations, neutron-transmutation doped Si (NTD n-Si:P). It is shown that, by choosing the temperature conditions of technological irradiation, one can solve the problem of attaining small values of {tau}{sub p} at a minimal increase in U{sub F} and I{sub R} in fast-response diodes. It is established that, in the case of comparable variations in {tau}{sub p} in the base region of diodes, the best relation between U{sub F} and I{sub R} is observed at T{sub irr} = 300 Degree-Sign C in n-Si:P samples doped by the Czochralski method and at T{sub irr} = 350 Degree-Sign C in samples doped by reactions induced by thermal neutrons.

36 MATERIALS SCIENCE↗

Novel method for detecting the hadronic component of extensive air showers

A novel method for studying the hadronic component of extensive air showers (EAS) is proposed. The method is based on recording thermal neutrons accompanying EAS with en-detectors that are sensitive to two EAS components: an electromagnetic (e) component and a hadron component in the form of neutrons (n). In contrast to hadron calorimeters used in some arrays, the proposed method makes it possible to record the hadronic component over the whole area of the array. The efficiency of a prototype array that consists of 32 en-detectors was tested for a long time, and some parameters of the neutron EAS component were determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resource Prospector Instrumentation for Lunar Volatiles Prospecting, Sample Acquisition and Processing

Data gathered from lunar missions within the last two decades have significantly enhanced our understanding of the volatile resources available on the lunar surface, specifically focusing on the polar regions. Several orbiting missions such as Clementine and Lunar Prospector have suggested the presence of volatile ices and enhanced hydrogen concentrations in the permanently shadowed regions of the moon. The Lunar Crater Observation and Sensing Satellite (LCROSS) mission was the first to provide direct measurement of water ice in a permanently shadowed region. These missions with other orbiting assets have laid the groundwork for the next step in the exploration of the lunar surface; providing ground truth data of the volatiles by mapping the distribution and processing lunar regolith for resource extraction. This next step is the robotic mission Resource Prospector (RP). Resource Prospector is a lunar mission to investigate 'strategic knowledge gaps' (SKGs) for in-situ resource utilization (ISRU). The mission is proposed to land in the lunar south pole near a permanently shadowed crater. The landing site will be determined by the science team with input from broader international community as being near traversable landscape that has a high potential of containing elevated concentrations of volatiles such as water while maximizing mission duration. A rover will host the Regolith & Environment Science and Oxygen & Lunar Volatile Extraction (RESOLVE) payload for resource mapping and processing. The science instruments on the payload include a 1-meter drill, neutron spectrometer, a near infrared spectrometer, an operations camera, and a reactor with a gas chromatograph-mass spectrometer for volatile analysis. After the RP lander safely delivers the rover to the lunar surface, the science team will guide the rover team on the first traverse plan. The neutron spectrometer (NS) and near infrared (NIR) spectrometer instruments will be used as prospecting tools to guide the traverse path. The NS will map the water-equivalent hydrogen concentration as low as 0.5% by weight to an 80 centimeter depth as the rover traverses the lunar landscape. The NIR spectrometer will measure surficial H2O/OH as well as general mineralogy. When the prospecting instruments identify a potential volatile-rich area during the course of a traverse, the prospect is then mapped out and the most promising location identified. An augering drill capable of sampling to a depth of 100 centimeters will excavate regolith for analysis. A quick assay of the drill cuttings will be made using an operations camera and NIR spectrometer. With the water depth confirmed by this first auguring activity, a regolith sample may be extracted for processing. The drill will deliver the regolith sample to a crucible that will be sealed and heated. Evolved volatiles will be measured by a gas chromatograph-mass spectrometer and the water will be captured and photographed. RP is a solar powered mission, which given the polar location translates to a relatively short mission duration on the order of 4-15 days. This short mission duration drives the concept of operations, instrumentation, and data analysis towards critical real time analysis and decision support. Previous payload field tests have increased the fidelity of the hardware, software, and mission operations. Current activities include a mission level field test to optimize interfaces between the payload and rover as well as better understand the interaction of the science and rover teams during the mission timeline. This paper will include the current status of the science instruments on the payload as well as the integrated field test occurring in fall of 2015. The concept of operations will be discussed, including the real time science and engineering decision-making process based on the critical data from the instrumentation. The path to flight will be discussed with the approach to this ambitious low cost mission.

ISRU↗

Grazing-Angle Neutron Diffraction Study of the Water Distribution in Membrane Hemifusion: From the Lamellar to Rhombohedral Phase

The water distribution between lipid bilayers is important in understanding the role of the hydration force at different steps of the membrane fusion pathway. Here in this study, we used grazing-angle neutron diffraction to map out the water distribution in lipid bilayers transiting from a lamellar structure to the hemifusion “stalk” structure in a rhombohedral phase. Under osmotic pressure exerted by different levels of relative humidity, the lipid membrane sample was maintained in equilibrium at different lattices suitable for neutron diffraction. The D 2 O used to hydrate the lipid membrane sample stood out from the lipid in the reconstructed structure because of its much higher coherent neutron scattering length density. The density map indicates that water dissociated from the headgroup in the lamellar phase. In the rhombohedral phase, water was significantly reduced and was squeezed into pockets around the stalk. This study complements earlier structural studies by grazing-angle X-ray diffraction, which is sensitive to only the parts of the structure with high electron density (such as phosphors). The experiment also demonstrated that the recently developed time-of-flight small-angle neutron scattering beamline at the Spallation Neutron Source is suitable for grazing-angle neutron diffraction to provide the structures of large unit cells on the order of a few nanometers, such as biomembrane structures.

59 BASIC BIOLOGICAL SCIENCES↗

Review of current neutron detection systems for emergency response

Neutron detectors are utilized in a myriad of applications—from safeguarding special nuclear materials (SNM) to determining lattice spacing in soft materials. The transformational changes taking place in neutron detection and imaging techniques in the last few years are largely being driven by the global shortage of helium-3 ( 3 He). This article reviews the status of neutron sensors used specifically for SNM detection in radiological emergency response. These neutron detectors must be highly efficient, be rugged, have fast electronics to measure neutron multiplicity, and be capable of measuring direction of the neutron sources and possibly image them with high spatial resolution. Neutron detection is an indirect physical process: neutrons react with nuclei in materials to initiate the release of one or more charged particles that produce electric signals that can be processed by the detection system. Therefore, neutron detection requires conversion materials as active elements of the detection system; these materials may include boron-10 ( 10 B), lithium-6 ( 6 Li), and gadollinium-157 ( 157 Gd), to name a few, but the number of materials available for neutron detection is limited. However, in recent years, pulse-shape-discriminating plastic scintillators, scintillators made of helium-4 ( 4 He) under high pressure, pillar and trench semiconductor diodes, and exotic semiconductor neutron detectors made from uranium oxide and other materials have widely expanded the parameter space in neutron detection methodology. In this article we will pay special attention to semiconductor-based neutron sensors. Finally, modern microfabricated nanotubes covered inside with neutron converter materials and with very high aspect ratios for better charge transport will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance Characterization of FB-Line Neutron Multiplicity Counter and Large Neutron Multiplicity Counter

Savanah River National Laboratory’s (SRNL) Nuclear Measurements group was tasked with characterizing the performance of two neutron multiplicity counters located at SRNL. Characterization measurements were made to determine the gate width, pre-delay, deadtime parameters, triples and doubles gate fractions, detector efficiency, and operating high voltage for the Large Neutron Multiplicity Counter (LNMC) and the FB Line Neutron Multiplicity Counter (FBLNMC). The parameters were determined, shown below, and were, as to be expected, slightly different than the previous calibrations, which were performed over 20 years ago. Several Pu samples were measured to validate the characterizations of the FBLNMC and LNMC. The measurements determined the sample Pu-240 mass within <2% deviation for the pure plutonium samples and ~8% for the mixed oxide sample. The pure Pu samples had significantly better accuracy compared with the impure mixed oxide sample due to the lack of induced fission or alpha,n neutrons from impurities. Overall, the characterization of the neutron multiplicity counters, and the determination of their operability has been completed successfully.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative assessment of different aluminum alloys for neutron beam window applications

The choice of an aluminum alloy window along a neutron beam requires careful consideration depending on the requirements of the instrument end station. The windows should generally be thin to minimize loss of neutrons from the beam due to scattering and absorption but still thick enough to be structurally sound for safety requirements. Further, the microstructure of the material is dependent on the alloy and the preparation method and may introduce scattering artifacts or smearing of the instrument resolution that are not desirable. In this manuscript, SANS and total cross section measurements of several different aluminum alloys will be presented and compared in order to provide some useful insight to engineers working on future neutron instrument design.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A New Era of Discovery: The 2023 Long-Range Plan for Nuclear Science (V.1.2)

Nuclear science is the investigation of how protons and neutrons are formed from elementary particles and how the forces between those particles produce both nuclei and the vast variety of nuclear phenomena that occur in the universe. It has evolved into a broad field that addresses profound scientific questions: Where does the mass of visible matter come from? How do stars ignite, live, and die? How do nuclei illuminate the search for new laws of nature? This science points the way to using nuclei to build new technologies that benefit society. The 2015 Nobel Prize in physics was shared by nuclear physicists Art McDonald and Takaaki Kajita for the discovery of neutrino oscillations, which confirmed that neutrinos have mass. Our progress on big questions like this one since 2015 has been remarkable owing to new experimental tools, theoretical breakthroughs, powerful computational techniques, and the talented people who make these innovations possible. Focusing on these new tools, the Facility for Rare Isotope Beams (FRIB) at Michigan State University is already producing exciting results on decays of never-before-produced isotopes a year after it was completed on time and on budget. The energy upgrade of the Continuous Electron Beam Accelerator Facility (CEBAF) at the Thomas Jefferson National Accelerator Facility (Jefferson Lab) was also completed on schedule and on budget—new data from this facility are revealing the spectrum, structure, and dynamics of protons, neutrons, nuclei, and mesons. On the theory front, we can now calculate the distribution of quarks inside the proton from first principles. The implementation of artificial intelligence (AI) and machine learning (ML) techniques has led to improved data analysis and increased efficiency in running experiments and theoretical calculations. The impact of nuclear science goes beyond expanding the frontiers of knowledge about matter in the universe. We simultaneously develop a STEM work force that advances the security, technology, health, and wealth of our nation. Some connections are obvious. Expert scientists trained to work with radioactive nuclei are in demand in nuclear security arenas and are highly sought after by various government agencies and private industries. Graduate students and postdoctoral fellows (postdocs) obtain extensive computational, modeling, and data science skills that are similarly in high demand. Less obvious but equally important is the connection between these trained scientists and success in other professions, including medicine, energy, and entrepreneurial pursuits. The workforce that enables discovery in nuclear science also makes breakthroughs in technologies with tremendous impact on the nation’s economic advancement.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The First Neptunium Dioxide Neutron Diffraction Experiment at HFIR

Here we present the first neutron diffraction experiment of a 50 mg sample of neptunium(IV) dioxide (NpO 2 ) powder at the High Flux Isotope Reactor (HFIR) using the wide-angle neutron diffractometer (WAND 2 ) HB-2C. We also provide a brief literature survey to pinpoint gaps in the crystal, electronic, and magnetic structure of NpO 2 to determine the optimum experiment to be pursued in the next HFIR user proposal cycle. Characterizing actinide materials with neutron diffraction, inelastic scattering, neutron imaging, polarized neutron studies, and small-angle neutron scattering techniques will increase our understanding of 5f electron behavior and elucidate atomic and magnetic structural properties. This strategy will help fill gaps in the literature and provide theoretical physicists with the data needed to build physical and chemical models to guide and validate computational methods. These methods may be used for predicting structural and chemical features of actinide-based materials. This proof-of-principle effort begins to uncover how to advance actinide science and technology at Oak Ridge National Laboratory (ORNL) using neutron capabilities. This effort has already sparked collaborative discussions between researchers outside the Radioisotope Science and Technology Division, including theoretical physicists from the Nuclear Nonproliferation Division and beamline scientists in the Neutron Scattering Division. We intend to continue pursuing neutron experiments and develop a scientific strategy focused on studying transuranium elements (e.g., Np, Pu, Am, and Cm) using the advanced neutron capabilities at ORNL.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The valence-fluctuating ground state of plutonium

A central issue in material science is to obtain understanding of the electronic correlations that control complex materials. Such electronic correlations frequently arise because of the competition of localized and itinerant electronic degrees of freedom. Although the respective limits of well-localized or entirely itinerant ground states are well understood, the intermediate regime that controls the functional properties of complex materials continues to challenge theoretical understanding. We have used neutron spectroscopy to investigate plutonium, which is a prototypical material at the brink between bonding and nonbonding configurations. In addition, our study reveals that the ground state of plutonium is governed by valence fluctuations, that is, a quantum mechanical superposition of localized and itinerant electronic configurations as recently predicted by dynamical mean field theory. Our results not only resolve the long-standing controversy between experiment and theory on plutonium’s magnetism but also suggest an improved understanding of the effects of such electronic dichotomy in complex materials.

36 MATERIALS SCIENCE↗

Analysis of a Prototype Multi-Detector Fast-Neutron Radiography Panel

A multi-detector fast neutron radiography panel was built using the previous work on scalable neutron radiography using the IDEAS ROSSPAD readout module. A new aluminum housing was built to accommodate a large number of detectors tiled together. Additional changes to startup and processing code were made to operate the detector as one cohesive unit. Spatial resolution of the full panel using Cs-137 gammas was reported to be 0.42 line pairs per centimeter at 90% MTF and 2.09 line pairs per centimeter at 10% MTF. Here, three neutron radiographs generated using a Cf-252 fission neutron source were used to determine the spatial resolution of the panel for neutrons. The experiments had 90% MTF values of 0.24, 0.3, and 0.27 line pairs per centimeter and 10% MTF values of 1.30, 1.46, and 1.40 line pairs per centimeter. An example neutron radiograph was also used to prove that the radiography panel can perform true neutron radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Precision determination of absolute neutron flux

A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using an alpha–gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10 B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478 keV gamma rays from neutron capture on 10 B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024%. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6 Li was determined to an overall uncertainty of 0.058%. We discuss the principle of the alpha–gamma method and present details of how the measurement was performed including the systematic effects. We further describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The new cold neutron chopper spectrometer at the Spallation Neutron Source: Design and performance

The design and performance of the new cold neutron chopper spectrometer (CNCS) at the Spallation Neutron Source in Oak Ridge are described. CNCS is a direct-geometry inelastic time-of-flight spectrometer, designed essentially to cover the same energy and momentum transfer ranges as IN5 at ILL, LET at ISIS, DCS at NIST, TOFTOF at FRM-II, AMATERAS at J-PARC, PHAROS at LANSCE, and NEAT at HZB, at similar energy resolution. Measured values of key figures such as neutron flux at sample position and energy resolution are compared between measurements and ray tracing Monte Carlo simulations, and good agreement (better than 20% of absolute numbers) has been achieved. The instrument performs very well in the cold and thermal neutron energy ranges, and promises to become a workhorse for the neutron scattering community for quasielastic and inelastic scattering experiments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗