Search NASA⌕ Search

SEARCH · Search NASA

Results for “Neutron Experiments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Simultaneous usage of pinhole and penumbral apertures for imaging small scale neutron sources from inertial confinement fusion experiments

Inertial confinement fusion experiments at the National Ignition Facility are designed to understand the basic principles of creating self-sustaining fusion reactions by laser driven compression of deuterium-tritium (DT) filled cryogenic plastic capsules. The neutron imaging diagnostic provides information on the distribution of the central fusion reaction region and the surrounding DT fuel by observing neutron images in two different energy bands for primary (13-17 MeV) and down-scattered (6-12 MeV) neutrons. From this, the final shape and size of the compressed capsule can be estimated and the symmetry of the compression can be inferred. These experiments provide small sources with high yield neutron flux. An aperture design that includes an array of pinholes and penumbral apertures has provided the opportunity to image the same source with two different techniques. This allows for an evaluation of these different aperture designs and reconstruction algorithms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transient convective delayed neutron precursor of {sup 235}U for the molten salt reactor experiment

This work investigates the delayed neutron precursors from the fission of {sup 235}U in molten salt reactors. The six delayed neutron groups predict the spatial distribution of the advective transport for radioactive mass transfer in the molten-salt reactor experiment (MSRE). The Mole code, using the framework of the Multiphysics Object-Oriented Simulation Environment (MOOSE), was used to compute the delayed neutron concentration of the whole system. This approach can be used for analysis of reactivity in circulating conditions. The effect of delayed neutron concentrations on the static or dynamic behavior of the system in MSRE was analyzed. Using this approach, the pattern and validation of delayed neutron for a range of parameters of interest are reported and discussed herein. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data from Rossi-α and Pulsed Neutron Prompt Neutron Time Decay Measurements at the Oak Ridge Critical Experiments Facility

This report briefly describes the prompt neutron decay measurements by the Rossi-α and pulsed neutron methods performed at the Oak Ridge Critical Experiments Facility. It briefly describes the measurement equipment, the type of data, and how to access the actual data from the Laboratory Records Department at Oak Ridge National Laboratory and the International Nuclear Criticality Safety Benchmark Evaluation Program at Idaho National Laboratory. Most of the data was acquired between 1960 and 1975 with weapons-grade enriched uranium metal assemblies. It also includes measurement of these types performed at Los Alamos National Laboratory by Oak Ridge National Laboratory with the JEZEBEL and FLATTOP criticality assemblies and other plutonium metal parts. The purpose of this report is to support future mining of the data for publication of additional information that can be used to verify calculational methods and nuclear cross sections. Present calculational methods can be used to directly calculate the measured data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Overview of the SNS Target System Testing and Initial Beam Operation Experience

The Spallation Neutron Source (SNS) construction project has been completed including initial beam operation with the mercury target, moderators and associated systems. The project was initiated in 1999, with groundbreaking in December of 1999. Final integrated system testing for the mercury target, cryogenic moderators, shutter systems, water and other utility systems and all control and safety systems were completed in April 2006 and first beam on target delivered April 28, 2006. This paper will give an overview of the system testing conducted in preparation for beam operation and initial operating experience with low power beams. One area of testing was extensive remote handling testing in the Target Service Bay to demonstrate all key operations associated with the target and mercury loop. Many improvements were implemented as a result of this experience. Another set of tests involved bringing the supercritical cryogenic moderator systems on line. Again, lesions learned here resulted in system changes. Testing of the four water loops was very time consuming because of the complexity of the systems and many instrumentation issues had to be resolved. A temporary phosphor view screen was installed on the front of the target which has been extremely useful in evaluating the beam profile on the target. Initial profile results will be presented. Target System performance for initial beam operation will be discussed. In general, all systems performed well with excellent availability. There were some unexpected findings. For example, xenon spallation gas products are believed to have deposited on a downstream gold amalgamation bed designed to remove mercury vapor and increased the local dose rate. A summary of findings and plans for ramping up in power will be given.

Spallation↗

Experimental study on the thorium-loaded accelerator-driven system at the Kyoto Univ. critical assembly

The experimental study on the thorium-loaded accelerator-driven system (ADS) is conducted in the Kyoto Univ. Critical Assembly (KUCA). The experiments are carried out in both the critical and subcritical states for attaining the reaction rates of the thorium capture and fission reactions. In the critical system, the thorium plate irradiation experiment is carried out for the thorium capture and fission reactions. From the results of the measurements, the thorium fission reactions are obtained apparently in the critical system, and the C/E values of reaction rates show the accuracy of relative difference of about 30%. In the ADS experiments with 14 MeV neutrons and 100 MeV protons, the subcritical experiments are carried out in the thorium-loaded cores to obtain the capture reaction rates through the measurements of {sup 115}In(n, {gamma}){sup 116m}In reactions. The results of the experiments reveal the difference between the reaction rate distributions for the change in not only the neutron spectrum but also the external neutron source. The comparison between the measured and calculated reaction rate distributions demonstrates a discrepancy of the accuracy of reaction rate analyses of thorium capture reactions through the thorium-loaded ADS experiments with 14 MeV neutrons. Hereafter, kinetic experiments are planned to be carried out to deduce the delayed neutron decay constants and subcriticality using the pulsed neutron method. (authors)

43 PARTICLE ACCELERATORS↗

Neutron Skin of {sup 208}Pb, Nuclear Symmetry Energy, and the Parity Radius Experiment

A precise determination of the neutron skin {Delta}r{sub np} of a heavy nucleus sets a basic constraint on the nuclear symmetry energy ({Delta}r{sub np} is the difference of the neutron and proton rms radii of the nucleus). The parity radius experiment (PREX) may achieve it by electroweak parity-violating electron scattering (PVES) on {sup 208}Pb. We investigate PVES in nuclear mean field approach to allow the accurate extraction of {Delta}r{sub np} of {sup 208}Pb from the parity-violating asymmetry A{sub PV} probed in the experiment. We demonstrate a high linear correlation between A{sub PV} and {Delta}r{sub np} in successful mean field forces as the best means to constrain the neutron skin of {sup 208}Pb from PREX, without assumptions on the neutron density shape. Continuation of the experiment with higher precision in A{sub PV} is motivated since the present method can support it to constrain the density slope of the nuclear symmetry energy to new accuracy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron decay correlations in the Nab experiment

The Nab experiment will measure the correlation a between the momenta of the beta particle and antineutrino in neutron decay as well as the Fierz term b which distorts the beta spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fast neutron background characterization of the future Ricochet experiment at the ILL research nuclear reactor

Abstract The future Ricochet experiment aims at searching for new physics in the electroweak sector by providing a high precision measurement of the Coherent Elastic Neutrino-Nucleus Scattering (CENNS) process down to the sub-100 eV nuclear recoil energy range. The experiment will deploy a kg-scale low-energy-threshold detector array combining Ge and Zn target crystals 8.8 m away from the 58 MW research nuclear reactor core of the Institut Laue Langevin (ILL) in Grenoble, France. Currently, the Ricochet Collaboration is characterizing the backgrounds at its future experimental site in order to optimize the experiment’s shielding design. The most threatening background component, which cannot be actively rejected by particle identification, consists of keV-scale neutron-induced nuclear recoils. These initial fast neutrons are generated by the reactor core and surrounding experiments (reactogenics), and by the cosmic rays producing primary neutrons and muon-induced neutrons in the surrounding materials. In this paper, we present the Ricochet neutron background characterization using $$^3$$ 3 He proportional counters which exhibit a high sensitivity to thermal, epithermal and fast neutrons. We compare these measurements to the Ricochet Geant4 simulations to validate our reactogenic and cosmogenic neutron background estimations. Eventually, we present our estimated neutron background for the future Ricochet experiment and the resulting CENNS detection significance. Our results show that depending on the effectiveness of the muon veto, we expect a total nuclear recoil background rate between 44 ± 3 and 9 ± 2 events/day/kg in the CENNS region of interest, i.e. between 50 eV and 1 keV. We therefore found that the Ricochet experiment should reach a statistical significance of 4.6 to 13.6 $$\sigma $$ σ for the detection of CENNS after one reactor cycle, when only the limiting neutron background is considered.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Nab experiment: A precision measurement of unpolarized neutron beta decay

Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, λ = gA/gV, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter a with a precision of δa/a = 10 -3 and the Fierz interference term b to δb = 3 × 10 -3 in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio λ with a precision of δλ/λ = 0.03% that will allow an evaluation of Vud and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.

Fry, Jason↗

Transverse spin structure of the nucleon through target single-spin asymmetry in semi-inclusive deep-inelastic (e, e’ $ \pi^{\pm}_{}$ ) reaction at Jefferson Lab

Jefferson Lab (JLab) 12 GeV energy upgrade provides a golden opportunity to perform precision studies of the transverse spin and transverse-momentum-dependent structure in the valence quark region for both the proton and the neutron. In this paper, we focus our discussion on a recently approved experiment on the neutron as an example of the precision studies planned at JLab. The new experiment will perform precision measurements of target Single Spin Asymmetries (SSA) from semi-inclusive electro-production of charged pions from a 40-cm long transversely polarized 3 He target in Deep-Inelastic-Scattering kinematics using 11 and 8.8 GeV electron beams. This new coincidence experiment in Hall A will employ a newly proposed solenoid spectrometer (SoLID). The large acceptance spectrometer and the high polarized luminosity will provide precise 4-D (x, z, P T ​ and Q 2 ) data on the Collins, Sivers, and pretzelocity asymmetries for the neutron through the azimuthal angular dependence. The full 2ππ azimuthal angular coverage in the lab is essential in controlling the systematic uncertainties. The results from this experiment, when combined with the proton Collins asymmetry measurement and the Collins fragmentation function determined from the e + e − collision data, will allow for a quark flavor separation in order to achieve a determination of the tensor charge of the d quark to a 10% accuracy. As a result, the extracted Sivers and pretzelocity asymmetries will provide important information to understand the correlations between the quark orbital angular momentum and the nucleon spin and between the quark spin and nucleon spin.

Parton Distribution Function↗

ECAR-1406 AS-RUN NEUTRONIC ANALYSIS OF THE AGC-1 EXPERIMENT IRRADIATED IN THE ATR SOUTH FLUX TRAP

This Engineering Calculations Analysis Report (ECAR) documents the results of the Advanced Test Reactor (ATR) detailed physics analyses performed to calculate the displacements per atom (DPA) and the fast neutron fluence (E > 0.1 MeV) of the Advanced Graphite Creep (AGC) experiment, AGC-1, irradiated in the ATR South Flux Trap (SFT) (see Figure 1) during ATR Cycle 145A, Cycle 145B, Cycle 146A, Cycle 146B, Cycle 147A, Cycle 148A and Cycle 148B. The results for these evaluations and analysis are reported herein.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The inertial confinement fusion experimental platform and diagnostics for studies of nuclear reactions relevant to nuclear astrophysics

High energy density plasmas generated in laser-driven inertial confinement fusion implosions provide unparalleled laboratory conditions for studying stellar-relevant nuclear reactions: plasma environment; hot and dense; uniquely high achievable neutron flux. These experiments have the potential to address long-standing questions about plasma effects on nuclear reactions hitherto experimentally inaccessible, including nuclear rates with thermally distributed reactants, plasma screening, and reactions involving nuclei in excited states. The National Ignition Facility (NIF) and OMEGA lasers are two primary facilities for executing experiments of this type. Existing and future nuclear diagnostics, along with supporting diagnostics to characterize the platform, enable exploitation of these plasmas for such nuclear astrophysics-relevant experiments. Here, this review describes the nuclear diagnostic capabilities currently available for these types of experiments at the NIF and OMEGA, including neutron time-of-flight spectrometers, charged-particle detectors, gamma detectors and radiochemistry diagnostics, and briefly summarizes other available diagnostic capabilities used for platform characterization. Enabling tools not yet available are also identified, including a rapid radioactive sample retrieval system, a low-energy neutron spectrometer and a high-efficiency gamma spectrometer.

National Ignition Facility↗

Epithermal Neutron Activation Analysis at the IBR-2 reactor of the Frank Laboratory of Neutron Physics at the Joint Institute for Nuclear Research (Dubna)

Experience of the Neutron Activation Analysis (NAA) Department in employing epithermal activation in life sciences and materials science is summarized. The potential of a combination of epithermal activation and the suppression of Compton scattering and contributions from cascade-photon-emitting elements for raising NAA-based analytical studies up to a new level are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Dense Plasma Focus Diagnostic Suite for the Surrogate Static Test

A Neutron Diagnosed Subcritical Experiment (NDSE) has been proposed to measure the reactivity of a subcritical ($k_{eff} <$ 1:0) plutonium experiment. This experiment requires a short, high-intensity neutron pulse delivered to the target material with precise timing. A feasibility study for the NDSE is being conducted jointly by National Security Technologies, LLC, and Los Alamos National Laboratory at Area 11 of the Nevada National Security Site. The goals of this study include characterizing and developing the proposed neutron pulse source, the fast photon detection system, and the shielding system to suppress scattering backgrounds.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SNS Injection Foil Experience

The Spallation Neutron Source comprises a 1 GeV, 1.4 MW linear accelerator followed by an accumulator ring and a liquid mercury target. To manage the beam loss caused by the H0 excited states created during the H charge exchange injection into the accumulator ring, the stripper foil is located inside one of the chicane dipoles. This has some interesting consequences that were not fully appreciated until the beam power reached about 840 kW. One consequence was sudden failure of the stripper foil system due to convoy electrons stripped from the incoming H beam, which circled around to strike the foil bracket and cause bracket failure. Another consequence is that convoy electrons can reflect back up from the electron catcher and strike the foil and bracket. An additional contributor to foil system failure is vacuum breakdown due to the charge developed on the foil by secondary electron emission. In this paper we will detail these and other interesting failure mechanisms, and describe the improvements we have made to mitigate them.

43 PARTICLE ACCELERATORS↗

SNS BEAM COMMISSIONING TOOLS AND EXPERIENCE

The Spallation Neutron Source (SNS) successfully met the primary construction project completion milestones in April 2006. An important ingredient of this successful commissioning was the development and use of software tools. With the increasing digitalization of beam diagnostics and increasing complexity of Integrated Control Systems of large accelerators, the need for high level software tools is critical for smooth commissioning. At SNS a special Java based infrastructure called XAL was prepared for beam commissioning. XAL provides a hierarchal view of the accelerator, is data base configured, and includes a physics model of the beam. This infrastructure and individual applications development along with a historical time line of the SNS commissioning will be discussed.

43 PARTICLE ACCELERATORS↗

Study on in situ calibration for neutron flux monitor in the Large Helical Device based on Monte Carlo calculations

Neutron monitoring is important to manage safety of fusion experiment facilities because neutrons are generated in fusion reactions. Monte Carlo simulations play an important role in evaluating the influence of neutron scattering from various structures and correcting differences between deuterium plasma experiments and in situ calibration experiments. We evaluated these influences based on differences between the both experiments at Large Helical Device using Monte Carlo simulation code MCNP5. A difference between the both experiments in absolute detection efficiency of the fission chamber between O-ports is estimated to be the biggest of all monitors. We additionally evaluated correction coefficients for some neutron monitors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INL Neutron Interrogation R&D: FY2010 MPACT End of Year Report

Experiments have been carried out to investigate the feasibility and utility of using neutron interrogation and small-scale, portable prompt gamma-ray neutron activation analysis (PGNAA) instruments for assaying uranium for safeguards applications. Prior work has shown the potential of the PGNAA technique for assaying uranium using reactor-based neutron sources and high-yield electronic neutron generators (ENGs). In this project we adapted Idaho National Laboratory's portable isotopic neutron spectroscopy (PINS) PGNAA system for measuring natural-enrichment uranium yellowcake and metallic depleted uranium and highly enriched uranium. This work used 252Cf as well as deuterium-deuterium (DD) and deuterium-tritium (DT) ENGs. For PGNAA measurements a limiting factor when assaying large objects is the detector dead time due to fast-neutron scattering off of the uranium; this limits the maximum useable neutron source strength to O(107) neutrons per second. Under these conditions the low PGNAA reaction cross sections for uranium prohibited the collection of useful uranium PGNAA signatures from either the yellowcake or metallic uranium samples. Measurement of the decay product activation in these materials following irradiation in the PGNAA geometry similarly did not produce useful uranium activation product – fission product signatures. A customized irradiation geometry tailored to optimally thermalize the interrogation neutron source, intended only for generating long-lived activation products – fission products and not intended for PGNAA measurements, might be possible using small scale ENGs but an application need and a modeling and simulation exercise would be recommended before advancing to experiments. Neutron interrogation PGNAA using a DT-ENG was found to be a quick and useful qualitative method for detecting the presence of oxygen in natural-enrichment uranium yellowcake. With a low effort of development work it would be reasonable to expect this measurement could be transitioned to a qualitative technique for assaying oxides as well as other common uranium matrices including nitrides, fluorides, carbides, and sodium-bonded metals. Inert-matrix fuel material confirmation would also be well-served through this technique. This may be of interest for nuclear Material Protection, Accounting, and Control for Transmutation (MPACT) safeguards applications as a method for confirming material-form declarations in advanced fuel cycle material inventories and for quality control during fuel fabrication.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗