Search NASA⌕ Search

SEARCH · Search NASA

Results for “Optimal sizing method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Numerical modeling of the SNS H{sup −} ion source

Ion source rf antennas that produce H- ions can fail when plasma heating causes ablation of the insulating coating due to small structural defects such as cracks. Reducing antenna failures that reduce the operating capabilities of the Spallation Neutron Source (SNS) accelerator is one of the top priorities of the SNS H- Source Program at ORNL. Numerical modeling of ion sources can provide techniques for optimizing design in order to reduce antenna failures. There are a number of difficulties in developing accurate models of rf inductive plasmas. First, a large range of spatial and temporal scales must be resolved in order to accurately capture the physics of plasma motion, including the Debye length, rf frequencies on the order of tens of MHz, simulation time scales of many hundreds of rf periods, large device sizes on tens of cm, and ion motions that are thousands of times slower than electrons. This results in large simulation domains with many computational cells for solving plasma and electromagnetic equations, short time steps, and long-duration simulations. In order to reduce the computational requirements, one can develop implicit models for both fields and particle motions (e.g. divergence-preserving ADI methods), various electrostatic models, or magnetohydrodynamic models. We have performed simulations using all three of these methods and have found that fluid models have the greatest potential for giving accurate solutions while still being fast enough to perform long timescale simulations in a reasonable amount of time. We have implemented a number of fluid models with electromagnetics using the simulation tool USim and applied them to modeling the SNS H- ion source. We found that a reduced, single-fluid MHD model with an imposed magnetic field due to the rf antenna current and the confining multi-cusp field generated increased bulk plasma velocities of > 200 m/s in the region of the antenna where ablation is often observed in the SNS source. We report here on comparisons of simulated plasma parameters and code performance using more accurate physical models, such as two-temperature extended MHD models, for both a related benchmark system describing a inductively coupled plasma reactor, and for the SNS ion source. We also present results from scaling studies for mesh generation and solvers in the USim simulation code.

07 ISOTOPE AND RADIATION SOURCES↗

NSLS-II biomedical beamlines for micro-crystallography, FMX, and for highly automated crystallography, AMX: New opportunities for advanced data collection

We present the final design of the x-ray optics and experimental stations of two macromolecular crystallography (MX) beamlines at the National Synchrotron Light Source-II. The microfocusing FMX beamline will deliver a flux of ∼5×10{sup 12} ph/s at 1 Å into a 1 – 20 µm spot, its flux density surpassing current MX beamlines by up to two orders of magnitude. It covers an energy range from 5 – 30 keV. The highly automated AMX beamline is optimized for high throughput, with beam sizes from 4 – 100 µm, an energy range of 5 – 18 keV and a flux at 1 Å of ∼10{sup 13} ph/s. A focus in designing the beamlines lay on achieving high beam stability, for example by implementing a horizontal bounce double crystal monochromator at FMX. A combination of compound refractive lenses and bimorph mirror optics at FMX supports rapid beam size changes. Central components of the in-house developed experimental stations are horizontal axis goniometers with a target sphere of confusion of 100 nm, piezo-slits for dynamic beam size changes during diffraction experiments, dedicated secondary goniometers for data collection from specimen in crystallization plates, and next generation pixel array detectors. FMX and AMX will support a broad range of biomedical structure determination methods from serial crystallography on micron-sized crystals, to structure determination of complexes in large unit cells, to rapid sample screening and room temperature data collection of crystals in trays.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lie-algebraic classical simulations for quantum computing

The classical simulation of quantum dynamics plays an important role in our understanding of quantum complexity and in the development of quantum technologies. Efficient techniques such as those based on the Gottesman-Knill theorem for Clifford circuits, tensor networks for low entanglement-generating circuits, or Wick's theorem for fermionic Gaussian states have become central tools in quantum computing. In this work, we contribute to this body of knowledge by presenting a framework for classical simulations, dubbed “𝔤-sim”, which is based on the underlying Lie algebraic structure of the dynamical process. When the dimension of the algebra grows at most polynomially in the system size, there exist observables for which the simulation is efficient. Indeed, we show that 𝔤-sim enables new regimes for classical simulations, is able to deal with certain forms of noise in the evolution, as well as can be used to tackle several paradigmatic variational and nonvariational quantum computing tasks. For the former, we perform Lie-algebraic simulations to train and optimize parametrized quantum circuits (thus effectively showing that some variational models can be dequantized), design enhanced parameter initialization strategies, solve tasks of quantum circuit synthesis, and train a quantum-phase classifier. For the latter, we report large-scale noiseless and noisy simulations on benchmark problems. By comparing the limitations of 𝔤-sim and certain Wick's theorem-based simulations, we find that the two methods become inefficient for different types of states or observables, hinting at the existence of distinct, nonequivalent resources for classical simulation.

97 MATHEMATICS AND COMPUTING↗

Design of High-Power Polyphase PCB Coil Systems for Wireless Power Transfer

Printed circuit board (PCB) coils have been proposed prior for implementation as inductive wireless charging coils to minimize size and cost. Utilization of PCBs can allow for a reduced cost, improved manufacturability, and a wide range of geometric customization options. To circumvent material limitations on insulation and thermal performance, parallel paths can be implemented to divide the current per path accordingly. Within this paper, an unconventional high-power PCB coil is designed employing all possible techniques for wiring with axial and radial parallel paths with equivalent transposition to minimize circulating currents. Design studies are simulated in 3D finite element analysis (FEA) to evaluate imbalance between phases with and without transposition. Two experimental prototype coils were fabricated with measurements for self-inductance and mutual inductance between phases. These measurements were validated to be sufficiently consistent with FEA results. Additionally, a method is proposed for a two-step optimization of coupling coefficient and coil losses.

Lewis, Donovin D.↗

SU-F-T-203: High Dose Definitive Proton Therapy with Integrated Boost to Hypoxic Subvolumes Determined by [18F]-Fluoromisonidazole (FMISO) PET/CT for Patients with Recurrent Chordomas Using Intensity Modulated Proton Therapy (IMPT)

Purpose: Recurrent chordomas are difficult to control locally. This dosimetric study investigates the feasibility of dose escalation to hypoxic regions, visualized on FMISO-PET, while respecting the dose constraints to the neighboring normal tissues/organs. We propose to deliver a higher dose to the areas of hypoxia (84.5Gy) using IMPT with the goal of improving local control. Methods: We currently have four patients with hypoxic subvolumes (HSV) greater than 10cc from the FMISO-PET image. The HSV was delineated based on the standardized uptake values of greater than 1.4 times of the muscle mean. Gross tumor volume (GTV) was delineated using planning CT with the assistance of MRI fusion. The dose scheme is 50.4Gy RBE to CTV in 1.8Gy fractions, followed by an integrated boost of 27.0Gy RBE to GTV in 1.8Gy fractions and 34.5Gy RBE to HSV in 2.3Gy fractions. IMPT integrated boost plans were optimized with multi-criteria optimization (MCO). Posterior-anterior beam angles were used for these plans. We also propose using two posterior oblique fields to boost HSV to spare the skin folding. A medium spot size with 8mm to 15 mm (σ) in air at isocenter with energies from 220 MeV down to 90 MeV was used. Aperture was used for the medium spot size. A small spot size of 2.5 mm to 4.5 mm (σ) in air at isocenter with energies from 240 MeV down to 70 MeV was also proposed. Target coverage and dose to OARs were evaluated. Results: For the sacral chordoma patient that has been planned, the target homogeneity index is 3.2% for HSV, 55.9% for CTV and 11.9% for GTV. The max dose is 77GyRBE to rectum, 86.2GyRBE to sacral nerves and 73.9GyRBE to cauda equina. Conclusion: IMPT with integrated high dose boost to HSV determined from FMISO PET image is feasible. OAR dose constraints were met.

60 APPLIED LIFE SCIENCES↗

Measurement techniques using the electron beam profile scanner at the Fermilab Main Injector

This work presents techniques for non-invasive transverse profile measurements of high-intensity proton beams using an Electron Beam Profile Scanner (EBPS). The EBPS utilizes low-energy electrons as a probe to analyze the transverse size of proton beams, allowing for potential analysis on a single-bunch basis. Recent upgrades to the Fermilab Main Injector have enhanced beam power on target to 1 MW, with future developments targeting 2 MW. The higher beam power has increased the demand for non-invasive diagnostics, as invasive methods can disrupt operations.The techniques presented include 1) the slow scan technique, which serves as a proof of concept for the probe beam, 2) the one-shot scan technique for measuring horizontal beam profiles, and 3) the raster scan technique for analyzing horizontal beam profiles as a function of the longitudinal distribution of the beam. The profiles obtained will be crucial for studying and understanding instabilities in high-power, high-intensity proton beams. This will contribute to optimizing the operation of high-power proton accelerators by minimizing beam loss, activation, and damage to both the diagnostics and the accelerator components.

Mwaniki, Matilda [IIT, Chicago]↗

Improved InGaN LED System Efficacy and Cost via Droop Reduction

Efficiency droop is a non-thermal process intrinsic to indium gallium nitride light emitting diodes (LEDs) in which the external quantum efficiency (EQE) decreases with increasing drive current density. Mitigating droop would allow one to reduce the size of LEDs driven at a given current or to drive LEDs of given size at higher current while maintaining high efficiencies. In other words, droop mitigation can lead to significant gains in light output per dollar and/or light output per watt of input power. This project set an EQE improvement goal at high drive current density which was to be attained by improving the LED active region design and growth process following a droop mitigation strategy. The interactions between LED active region design parameters and efficiency droop were studied by modeling and experiments. The crystal defects that tend to form in more complex LED designs intended to mitigate droop were studied with advanced characterization methods that provided insight into the structural and electronic properties of the material. This insight was applied to improve the epitaxy process both in terms of active region design and optimization of growth parameters. The final project goals were achieved on schedule and an epitaxy process leading to LEDs with EQE exceeding the project target was demonstrated.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Absorber Column CFD model validation against PNNL’s device-scale absorber column on the LCFS unit

Absorber column has been widely used for CO 2 capture in the coal-fired power plants. High-fidelity CFD models play an important role in absorber column design and solvents optimization, which help enhance the CO 2 capture efficiency and reduce the operation cost. This report provides a comprehensive description of the development of CFD absorber models at two different levels, the design and implementation of PNNL’s device-scale absorber column experiment, and the methodology to combine the CFD results, experiment data, and Aspen model for a better understanding of the interface area in packed column. A composite model is firstly proposed in the Discrete Element Method (DEM) packing process, which can model the complex geometry of various packing elements. This generates a realistic packing pattern and accurate packing porosity ε and specific area a p compared to the actual values for absorber column used in LCFS. Two level of CFD absorber models were developed, namely the full-size column model (FCM) to simulate the entire packed column with a focus on the wall/entrance effects, and the representative column model (RCM) to simulate a section of column with a focus on the sensitivity study of interface area. A Design of Experiment (DoE) plan was developed to guide the collection of 100 run CFD data and 12 experiment runs. The 100 CFD runs were carried out in the RCM with Pro-Pak packing and cover a wide operation range and solvent properties. Impact of influential factors on the interface area in packed column were investigated in details. The CFD interface area was then combined with the experimental data and Aspen model to infer some information of the effective contact angle in the column. The accuracy and uncertainties in the interface area and contact angle can be quantified.

01 COAL, LIGNITE, AND PEAT↗

Production of Particle Reference and Quality Control Materials

Maintaining the superior performance of new analytical instrumentation and pushing the boundaries of ever-smaller particle analysis by methods such as secondary ion mass spectrometry (SIMS) has become limited by the availability of certified particle standards for calibration, quality control, and validation. To meet this growing demand for a reliable and universal approach to the generation of uranium particle reference material, the Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL) are collaborating on a joint venture that establishes a number of chemical pathways to the fabrication, purification, and stabilization of uranium particle material to within a fixed particle size range, and well-characterized isotopics. PNNL particle standards are designed and tailored to meet the criteria essential to the calibration and benchmarking of instruments used in both the non-destructive and destructive assay of particulate material, typically collected from environmental swipe sampling. Previous testing and optimization of this colloidal approach to particulate material has centred on tight size distributions, singular composition and density, uniform morphology, and tailored isotopic abundances. Extensive validation of this material has since been performed, both at the National Institute of Standards and Technology (NIST) and the International Atomic Energy Agency (IAEA), demonstrating its suitability for quality control needs of large geometry (LG)-SIMS analysis. Building on this momentum, the production of low-enriched uranium particle reference material, with specially tailored isotopics, has moved from development to full operation. Herein, various aspects of the production cycle will be discussed, including detailed accounts of the technical methodologies being employed, as well as insights into the sample characterization and acceptance testing requirements.

Nuclear Safeguards, Particle Standards, IAEA↗

SU-E-I-49: Simulation Study for Removing Scatter Radiation in Cesium-Iodine Based Flat Panel Detector System

Purpose: This study aims to identify the feasibility of a novel cesium-iodine (CsI)-based flat-panel detector (FPD) for removing scatter radiation in diagnostic radiology. Methods: The indirect FPD comprises three layers: a substrate, scintillation, and thin-film-transistor (TFT) layer. The TFT layer has a matrix structure with pixels. There are ineffective dimensions on the TFT layer, such as the voltage and data lines; therefore, we devised a new FPD system having net-like lead in the substrate layer, matching the ineffective area, to block the scatter radiation so that only primary X-rays could reach the effective dimension.To evaluate the performance of this new FPD system, we conducted a Monte Carlo simulation using MCNPX 2.6.0 software. Scatter fractions (SFs) were acquired using no grid, a parallel grid (8:1 grid ratio), and the new system, and the performances were compared.Two systems having different thicknesses of lead in the substrate layer—10 and 20μm—were simulated. Additionally, we examined the effects of different pixel sizes (153×153 and 163×163μm) on the image quality, while keeping the effective area of pixels constant (143×143μm). Results: In case of 10μm lead, the SFs of the new system (∼11%) were lower than those of the other system (∼27% with no grid, ∼16% with parallel grid) at 40kV. However, as the tube voltage increased, the SF of new system (∼19%) was higher than that of parallel grid (∼18%) at 120kV. In the case of 20μm lead, the SFs of the new system were lower than those of the other systems at all ranges of the tube voltage (40–120kV). Conclusion: The novel CsI-based FPD system for removing scatter radiation is feasible for improving the image contrast but must be optimized with respect to the lead thickness, considering the system’s purposes and the ranges of the tube voltage in diagnostic radiology. This study was supported by a grant(K1422651) from Institute of Health Science, Korea University.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Contact pressure analysis to allow improved design for the clearing plate in a biomass comminution system

For biomass processing systems, feedstocks with small but equal sizes can improve flowability and thermochemical outputs. The Crumbler rotary shear system was designed to achieve such ideal feedstocks to reduce costs and energy throughout the biomass supply chain. Improving the wear resistance of major components in this system is important to decrease the cost. Accelerating the feedstock flow through the rotary shear machine plays an equivalent role of improving its efficiency. An analytical analysis and a finite-element analysis of the stationary clearing plate are presented in this work. Here, these tools are used to investigate the effect of contact surface curvature on the impact pressure. The optimized new clearing plate design is expected to improve the component’s lifetime and wood chips flowability. The field tests confirm that the trend of the new clearing plate design guided by FEA. The optimization method, model verification, and validation experience applied in this work can also be applied to other static components with similar simple contact wear problems.

09 BIOMASS FUELS↗

Insights into Waterflooding in Hydrocarbon-Bearing Nanochannels of Varying Cross Sections from Mesoscopic Multiphase Flow Simulations

Waterflooding is one of the geotechnique used to recover fuel sources from nanoporous geological formations. The scientific understanding of the process that involves the multiphase flow of nanoconfined fluids, however, has lagged, mainly due to the complex nanopore geometries and chemical compositions. To enable benchmarked flow of nanoconfined fluids, the architected geomaterials, such as synthesized mesoporous silica with tunable pore shapes and surface chemical properties, are used for designing and conducting experiments and simulations. This work uses a modified many-body dissipative particle dynamics (mDPD) model with accurately calibrated parameters to perform parametric flow simulations for studying the influences of waterflooding driven power, pore shape, surface roughness, and surface wettability on the multiphase flow in heptane-saturated silica nanochannels. Remarkably, up to 80\% reduction in the effective permeability is found for water-driven heptane flow in a baseline 4.5 nm-wide slit channel, when compared with the Hagen–Poiseuille equation. In the 4.5 nm-wide channels with architected surface roughness, the flow rate is found either higher or lower than the baseline case, depending on the shape and size of cross-sections. High wettability of the solid surface to water is essential for achieving high recovery of heptane, regardless of surface roughness. When the solid surface is less wetting or non-wetting to water, the existence of an optimal waterflooding driven power is found to allow for the highest possible recovery. A detailed analysis on the evolution of the transient water-heptane interface in those nanochannels is presented to elucidate the underlying mechanisms that impact or dictate the multiphase flow behaviors.

58 GEOSCIENCES↗

Quantum-Inspired Power System Reliability Assessment

To enable an in-depth study of power system operation and planning, the assessment of standard reliability indices is inevitable. The Monte Carlo Simulation (MCS) approach is a broadly used method in replacing the analytical methods in reliability indices assessment. The accuracy of MCS, however, highly depends on the sampling size, and hence, a complicated system with large number of components requires a large sampling size and daunting computational effort. To address this shortcoming, we, in this paper attempt to take advantage of potentials of the quantum computing (QC) for power system reliability assessment by realizing the following contributions: 1) an innovative quantum model designed for reliability assessment; 2) a quantum circuit that achieves the quadratic speed up compared to the classical MCS method; 3) an efficient quantum amplitude estimation (QAE) algorithm to accurately evaluate the reliability indices. The accuracy and efficacy of the quantum reliability method are extensively verified and demonstrated on both radial and mesh distribution systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

An analysis of the spatio-temporal resolution of the immersed boundary method with direct forcing

The immersed boundary method (IBM) with direct forcing is very popular in the simulation of rigid particulate flows. In the IBM, an interaction force is introduced at the interface between fluid and particle in order to approximate the no-slip boundary condition. The interaction force is calculated through dividing the velocity difference (or error) between fluid and particle at the interface by the time step. Here, a dynamic equation for the velocity difference is derived. Additionally, analyses on the dynamic equation provide a few new findings: (i) The interaction force is the solution of a least-squares error problem, with the direct implication that the Lagrangian marker distribution has no effect on the large scale flow structure once the distribution of Lagrangian markers become saturated along the interface (i.e., each marker remains properly correlated with all its neighbors); (ii) The Lagrangian volume-weight is a relaxation factor to control how fast the velocity error decays to the ideal value of zero; (iii) The optimal choice of the Lagrangian volume-weight is the largest value permissible by a stability condition. A comprehensive convergence analysis with regard to the spatial and temporal resolution is presented for the velocity error and also for the shear-stress and surface pressure. In three simple canonical problems, it is analytically and numerically shown that the IBM results converge to the theoretical solutions obtained with precise imposition of no-slip and no-penetration boundary conditions. It is observed that it is not necessary to match the Lagrangian marker volume-weight to that of the local Eulerian cell volume and in fact this matching leads to lower than optimal computational efficiency. However, it is found that extremely high Eulerian grid resolution and small time step have to be used to obtain high precision simulation results. Especially, the time step should be inversely proportional to the particle Reynolds number for low Reynolds number flows. For high frequency oscillation problems, the grid size needs to be reduced by a factor of the square root of the frequency, and the time step to be reduced by a factor of the frequency. The theoretical findings here can be used to alleviate the technical difficulties in simulating non-spherical particles by not requiring the Lagrangian marker distribution to match the Eulerian grids and also in the implementation of IBM on non-uniform Eulerian grids. The present work also provides simple practical guidance on the choice of temporal and spatial resolution so as to control the simulation error a priori.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Using the Stix finite element RF code to investigate operation optimization of the ICRF antenna on Alcator C-Mod

Abstract As the Ion Cyclotron Radio Frequency range (ICRF) heating becomes more favorable in fusion devices, the urgency of predicting and mitigating impurity generation that arises from it becomes more pressing. In the ICRF regime, rectified Radio Frequency (RF) sheaths are known to form at antenna and material edges that influence negative effects like sputtering and a decrease in heating efficiency. Methods to mitigate the formation of these RF sheaths through RF image currents cancellation have been experimentally studied. A power-phasing scan done on Alcator C-Mod in which the amount of power on the two inner straps ( P in ) versus the total 4 straps ( P tot ) was varied showed a minimization of enhanced potentials between P in / P tot ∼ 0.7–0.9 while impurities were minimized for P in / P tot ∼ 0.5–0.8. New capabilities in the realm of representing the RF sheath numerically now allow for these experiments to be simulated. Given the size of the sheath relative to the scale of the device, it can be approximated as a Boundary Condition (BC). A new parallelized cold-plasma wave equation solver called Stix implements a non-linear sheath impedance model BC formulated by Myra et al (2015 Phys. Plasmas 22 062507) through the method of finite elements using the MFEM library [ http://mfem.org ]. It is seen that Stix shows qualitative agreement with the measured C-Mod enhanced potentials.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Thermal Stability of the Dot-in-Well Gain Medium for Photonic Crystal Surface Emitting Lasers

Self-assembled quantum dots (QDs) embedded in InGaAs quantum wells (QWs) are used as active regions for photonic-crystal surface-emitting lasers (PCSELs). An epitaxial regrowth method is developed to fabricate the dot-in-well (DWELL) PCSELs. Here, the epitaxial regrowth starts with the growth of a partial laser structure containing bottom cladding, waveguide, active region, and the photonic crystal (PC) layer. The PC layer is patterned to realize the cavity. Subsequently a top cladding layer is regrown to complete the laser structure. During the regrowth of the top cladding layer, the partial laser structure is subjected to high growth temperatures in excess of 600 °C resulting in an unintentional annealing of the active region. This annealing of the active region can alter the QDs by changing their size resulting in a blue shift in photoluminescence (PL) and narrowing PL emission. This effect results in the misaligning of the gain peak and the cavity resonance, resulting in sub-optimal lasing performance. DWELL active regions are known to have better thermal stability compared to both QDs and QWs and could be an ideal candidate for regrown PCSELs. We successfully demonstrate an optically-pumped epitaxially-regrown DWELL PCSEL with an emission wavelength of 1230 nm operating at room temperature. Furthermore, the DWELL active region shows excellent emission wavelength stability and intensity despite the high temperature regrowth process.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

SU-E-T-560: Monte Carlo Simulation of the Neutron Radiation Field Around a Medical 18 MV Linac

Purpose: Today the majority of radiation therapy treatments are performed at medical electron linear accelerators (linacs). The accelerated electrons are used for the generation of bremsstrahlung photons. The use of higher electron respectively photon energies has some advantages over lower energies such as the longer dose build-up. However photons with energies higher than ∼7 MeV can additionally to the interaction with bound electrons undergo inelastic reactions with nuclei. These photonuclear reactions lead to the emission of fast neutrons which contaminate the primary photon field. The neutrons might penetrate through the collimators and deliver out-of-field dose to the patient. Furthermore the materials inside the linac head as well as the air inside the treatment room get activated which might deliver dose to the medical employees even when the linac is not in operation. A detailed knowledge of these effects is essential for adequate radiation protection of the employees and an optimal patient treatment. Methods: It is a common method to study the radiation fields of such linacs by means of Monte Carlo simulations. For the investigation of the effects caused by photonuclear reactions a typical linac in high energy mode (Varian Clinac 18 MV-X) as well as the surrounding bunker were modelled and simulated using the Monte Carlo code FLUKA which includes extensive nuclear reaction and neutron transport models additional to electron-photon transport as well as capabilities for a detailed study of effective dose distributions and activation yields. Results: Neutron spectra as well as neutron effective dose distributions within the bunker were obtained, reaching up to some mSv/Gy in the patient’s plane. The results are normalized per Gy in the depth dose maximum at 10×10 cm{sup 2} field size. Therefore an absolute interpretation is possible. Conclusion: The obtained data gives a better understanding of the photonuclear reaction caused effects.

61 RADIATION PROTECTION AND DOSIMETRY↗

Application of Proliferation Resistance Optimization (PRO-X) Methodology to a Generic Research Reactor

The Proliferation Resistance Optimization Program (PRO-X) has been established by the NNSA to provide a framework for evaluating and integrating proliferation resistance into nuclear reactor system (core, fuel, and auxiliary facilities) designs that also maintain the safety and peaceful use missions of those systems. The research reactor (PRO-RR) area is the component of PRO-X that supports the program objectives by applying state-of-the-art analysis methods to research reactor systems. This report details the results of using a defined set of analytical tools to evaluate the neutronics, thermal hydraulics and proliferation risk characteristics of a set of parametric cores based on a generic 10 MW materials test reactor that uses a plate-type low enriched uranium (LEU) fuel. The analysis shows that by suitable adjustment of the core size, reflector configuration and power level, mission performance and safety margins can be maintained or improved while reducing the potential for production of special nuclear material.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗