Search NASA⌕ Search

SEARCH · Search NASA

Results for “PRISMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

ROSAT observations of the x ray binary HD 154791

We have been surveying the Taurus dark cloud for young stars using a variety of techniques. Two optical proper motion surveys identified 8 new pre-main sequence stars; an IRAS-based program discovered 6 new embedded sources and 4-6 new T Tauri stars. Finally, an optical objective prism survey found 12 new T Tauri stars. Our goal in this project is to examine and compare star formation in the dark clouds: Heiles cloud 2 (HCL2), L1537, L1538, and L1544. HCL2 is a very dense region actively forming young stars and contains 5-6 very young, deeply embedded sources; L1537 and L1538 have no known pre-main sequence stars; L1544 contains 7 optically visible T Tauri stars. These clouds appear roughly similar on optical sky survey plates. We would like to know why some of the clouds are active and why some are not. The first goal of the project is to survey the regions using IR photometry to identify very red pre-main sequence stars and X-ray imaging to identify solar-type young stars missed in the near-IR survey. We will follow up these observations with molecular line surveys to compare the conditions in various clouds with their star formation efficiencies.

Kenyon, Scott J.↗

High redshift QSOs and the x ray background

ROSAT pointed observations were made of 9 QSO's from the Large Bright Quasar Survey (LBQS). The LBQS is based on machine measurement of objective prism plates taken with the UK Schmidt Telescope. Software has been used to select QSO's by both color and by the presence of spectral features and continuum breaks. The probability of detection can be calculated as a function of magnitude, redshift and spectral features, and the completeness of the survey can be accurately estimated. Nine out of 1040 QSO's in the LBQS have z greater than 3. The observations will provide an important data point in the X-ray luminosity function of QSO's at high redshift. The QSO's with z greater than 3 span less than a magnitude in M(sub B), so can be combined as a homogeneous sample. This analysis is only possible with a sample drawn from a large and complete catalog such as the LBQS. Four of the 9 QSO's that were observed with the ROSAT PSPC for this proposal were detected, including one of the most luminous X-ray sources ever observed. The April 1992 version of the PROS DETECT package was used to reduce the data. The results have been used to search for evolution of the X-ray properties of QSO's in redshift. The 9 QSO's lie in the range -28.7 less than M(sub B) less than -27.8. When combined with data for 16 QSO's in a similar luminosity range at lower redshift correlations with luminosity and redshift can be separated out. The LBQS sample also yields a new constraint on the contribution of high redshift QSO's to the X-ray background. An initial requirement is knowledge of the X-ray properties (alpha(sub OX)) as a function of redshift. Integration over the evolving luminosity function of the LBQS then gives the QSO contribution to the source counts.

Impey, Chris↗

High resolution visible to short-wave near-infrared CCD spectra of Mars during 1990

The 0.4 to 1.0 micron spectrum of Mars is dominated by a steep red, relatively featureless spectral slope. Earlier lower spectral observations interpreted the red color and the lack of absorption features in the spectra as evidence of poorly crystalline ferric oxide minerals. More recent higher spectral resolution observations and reinterpretations of older data sets have revealed measureable spectral structure, however. For example, absorption features near 0.65 and 0.86 micron were detected and spatially mapped in data obtained during the 1988 opposition. These absorptions were interpreted as evidence for crystalline hematite on Mars, occuring as an accessory phase in abundances of 3 to 6 percent in the soil. We are attempting to verify the existence of these subtle crystalline Fe(3+) absorption features and to map their spatial distribution in regions of the planet not imaged in 1988. During the 1990 opposition, we obtained imaging spectroscopic data of Mars from the University of Hawaii 2.24 m telescope at Mauna Kea Observatory. The data were obtained with the Wide Field Grism Spectrograph (WFGS), which uses an 800 x 800 CCD and a transmission grating ruled on a prism. We used a grating blazed at 4800 A in first order to obtain data from 0.50 to 0.94 micron at a spectral resolution of R = 200 to 350. The moon/Mars slit design used had projected dimensions of 0.29 x 153 inches, allowing for high spectral resolution and adequate cross-slit spatial sampling of the Martian disk.

Bell, James F., III↗

Indications for common origin and gravitational interaction in three binary LMC clusters

Three close pair clusters of the LMC, NGC 2006/SL 538, NGC 2011 a/b, and NGC 2042 a/b, have been studied in order to establish their binarity. The stellar content in the outer region of each cluster has been investigated by means of low resolution objective UK Schmidt prism spectra, the cores of the clusters have been examined using low resolution integrated IUE spectra, whereas their density profiles and their observed dynamical parameters have been derived by means of star counts. The integrated spectra of their cores and the stellar content of their outer cluster regions have shown a common origin and a very young age (less than 2 x 10 exp 7 yr) for each member of the pairs, whereas their dynamical study has shown that they are gravitationally interacting. Comparing the age of their stellar content with their dynamical and relaxation times, it has been found that these clusters are physically associated and had no time to relax by stellar encounters, no time to merge, and no time to be destroyed by dynamical friction.

Kontizas, E.↗

Laser velocimeter for near-surface measurements

The present invention relates to a laser Doppler velocimeter for near-wall measurements which includes at least one beam-turning device. The beam-turning device receives laser light, reflects and redirects the light at various angles in order to obtain measurements for all three velocity components at grazing incident angles. The beam-turning device includes a mirror or prism at one end which reflects the received light in a particular direction. A collector lens receives the particle scattered light from which the relevant velocity components are determined. The beam-turning device can also be a miniature fiber optic head which outputs laser light and can be turned in any direction.

Johnson, Dennis A.↗

Higher order finite element analysis of thick composite laminates

A higher order, sub-parametric, laminated, 3D solid finite element was used for the analysis of very thick laminated composite plates. The geometry of this element is defined by four nodes in the X-Y plane which define a prism of material through the thickness of the laminate. There are twenty-four degrees of freedom at each node; translations at the upper and lower surfaces of the laminate in each of the three coordinate directions, and the derivatives of these translations with respect to each coordinate. This choice of degrees of freedom leads to displacement and strain compatibility at the corners. Stacking sequence effects are accounted for by explicitly integrating the strain energy density through the thickness of the element. The laminated solid element was combined with a gap-contact element to analyze thick laminated composite lugs loaded through flexible pins. The resulting model accounts for pin bending effects that produce non-uniform bearing stresses through the thickness of the lug. A thick composite lug experimental test program was performed, and provided data that was used to validate the analytical model. Two lug geometries and three stacking sequences were tested.

Goering, J.↗

Simulation of patch and slot antennas using FEM with prismatic elements and investigations of artificial absorber mesh termination schemes

Year 1 progress can be characterized with four major achievements which are crucial toward the development of robust, easy to use antenna analysis code on doubly conformal platforms. (1) A new FEM code was developed using prismatic meshes. This code is based on a new edge based distorted prism and is particularly attractive for growing meshes associated with printed slot and patch antennas on doubly conformal platforms. It is anticipated that this technology will lead to interactive, simple to use codes for a large class of antenna geometries. Moreover, the codes can be expanded to include modeling of the circuit characteristics. An attached report describes the theory and validation of the new prismatic code using reference calculations and measured data collected at the NASA Langley facilities. The agreement between the measured and calculated data is impressive even for the coated patch configuration. (2) A scheme was developed for improved feed modeling in the context of FEM. A new approach based on the voltage continuity condition was devised and successfully tested in modeling coax cables and aperture fed antennas. An important aspect of this new feed modeling approach is the ability to completely separate the feed and antenna mesh regions. In this manner, different elements can be used in each of the regions leading to substantially improved accuracy and meshing simplicity. (3) A most important development this year has been the introduction of the perfectly matched interface (PMI) layer for truncating finite element meshes. So far the robust boundary integral method has been used for truncating the finite element meshes. However, this approach is not suitable for antennas on nonplanar platforms. The PMI layer is a lossy anisotropic absorber with zero reflection at its interface. (4) We were able to interface our antenna code FEMA_CYL (for antennas on cylindrical platforms) with a standard high frequency code. This interface was achieved by first generating equivalent magnetic currents across the antenna aperture using the FEM code. These currents were employed as the sources in the high frequency code.

Gong, J.↗

A unified multigrid solver for the Navier-Stokes equations on mixed element meshes

A unified multigrid solution technique is presented for solving the Euler and Reynolds-averaged Navier-Stokes equations on unstructured meshes using mixed elements consisting of triangles and quadrilaterals in two dimensions, and of hexahedra, pyramids, prisms, and tetrahedra in three dimensions. While the use of mixed elements is by no means a novel idea, the contribution of the paper lies in the formulation of a complete solution technique which can handle structured grids, block structured grids, and unstructured grids of tetrahedra or mixed elements without any modification. This is achieved by discretizing the full Navier-Stokes equations on tetrahedral elements, and the thin layer version of these equations on other types of elements, while using a single edge-based data-structure to construct the discretization over all element types. An agglomeration multigrid algorithm, which naturally handles meshes of any types of elements, is employed to accelerate convergence. An automatic algorithm which reduces the complexity of a given triangular or tetrahedral mesh by merging candidate triangular or tetrahedral elements into quadrilateral or prismatic elements is also described. The gains in computational efficiency afforded by the use of non-simplicial meshes over fully tetrahedral meshes are demonstrated through several examples.

Mavriplis, D. J.↗

The high-resolution cross-dispersed echelle white-pupil spectrometer of the McDonald Observatory 2.7-m telescope

A new high-resolution cross-dispersed echelle spectrometer has been installed at the coude focus of the McDonald Observatory 2.7-m telescope. Its primary goal was simultaneously to gather spectra over as much of the spectral range 3400 A to 1 micrometer as practical, at a resolution R identical with lambda/Delta lambda which approximately = 60,000 with signal-to-noise ratio of approximately 100 for stars down to magnitude 11, using 1-h exposures. In the instrument as built, two exposures are all that are needed to cover the full range. Featuring a white-pupil design, fused silica prism cross disperser, and folded Schmidt camera with a Tektronix 2048x2048 CCD used at either of two foci, it has been in regularly scheduled operation since 1992 April. Design details and performance are described.

Tull, Robert G.↗

Dual Telecentric Lens System For Projection Onto Tilted Toroidal Screen

System of two optical assemblies for projecting image onto tilted toroidal screen. One projection lens optimized for red and green spectral region; other for blue. Dual-channel approach offers several advantages which include: simplified color filtering, simplified chromatic aberration corrections, less complex polarizing prism arrangement, and increased throughput of blue light energy. Used in conjunction with any source of imagery, designed especially to project images formed by reflection of light from liquid-crystal light valve (LCLV).

Gold, Ronald S.↗

Method To Display Data On A Face Mask

Proposed electronic instrument displays information on diver's or firefighter's face mask. Includes mask, prism, electronic readouts, transceiver and control electronics. Mounted at periphery of diver's field of view to provide data on elapsed time, depth, pressure, and temperature. Provides greater safety and convenience to user.

Moore, Kevin-Duron↗

Airborne spectrograph for the thermal IR: Broadband Array Spectrograph System

Spectroscopic studies in the 'fingerprint' region of the thermal IR from 3 to 14 microns of celestial dust components and the overall energy distribution of the sources are best served by moderate spectral resolution (R = lambda/Delta lambda approximately 30 to 200), high sensitivity observations. Spectral purity and the reproducibility of the spectral shape are critical as well, when using the spectral shape to assign temperatures to dust grains or to gas clouds based on the wavelength and shape of molecular bands. These sensor attributes are also important to the use of wavelengths and ratios of solid state features to derive compositions of dust grains in celestial sources. The advent of high quality linear arrays of blocked impurity band (BIB) detectors of Si:As permitted the development of a state-of-the-art, patented, cooled prism spectrograph. Developed at The Aerospace Corporation largely with in-house funds, the Broadband Array Spectrograph System (BASS) has been used for a variety of remote sensing applications, but especially for IR astronomical studies on the Kuiper Airborne Observatory and at the NASA Infrared Telescope Facility (IRTF). The attributes of the spectrograph, specifically having the pupil imaged onto the 2 linear 58 element detector arrays so that the effects of guiding errors are minimized, being able to maximally exploit the limited observing time by acquiring all 116 spectral channels simultaneously, and having all spectral channels imaged through the same aperture so that spectral mapping is readily and reliably accomplished, afford the scientist with a unique opportunity to conduct both surveys of examples of many different types of sources as well as in-depth studies of a given class of object by thoroughly sampling the class members. This duality was demonstrated with the BASS through a combination of KAO flights where spectral maps were obtained as part of in-depth studies of specific source regions (such as Orion and W3) and flights where up to 21 legs/flight were used to survey many different sources of different types.

Russell, Ray W.↗

Use of prismatic films to control light distribution

Piping light for illumination purposes is a concept which has been around for a long time. In fact, it was the subject of an 1881 United States patent which proposed the use of mirrors inside a tube to reflect light from wall to wall down the tube. The use of conventional mirrors for this purpose, however, has not worked because mirrors do not reflect well enough. On the other hand, optical fibers composed of certain glasses or plastics are known to transport light much more efficiently. The light that enters is reflected back and forth within the walls of the fiber until it reaches the other end. This is possible by means of a principle known as 'total internal reflection'. No light escapes through the walls and very little is absorbed in the bulk of the fiber. However, while optical fibers are very efficient in transporting light, they are impractical for transporting large quantities of light. Lorne Whitehead, as a student at the University of British Columbia, recognized that prismatic materials could be used to create a 'prism light guide', a hollow structure that can efficiently transport large quantities of light. This invention is a pipe whose transparent walls are formed on the outside into precise prismatic facets. The facets are efficient total internal reflection mirrors which prevent light travelling down the guide from escaping. Very little light is absorbed by the pipe because light travels primarily in the air space within the hollow guide. And, because the guide is hollow, weight and cost factors are much more favorable than would be the case with very large solid fibers. Recent advances in precision micromachining, polymer processing, and certain other manufacturing technologies have made the development of OLF (Optical Lighting Film) possible. The process is referred to as 'microreplication' and has been found to have broad applicability in a number of diverse product areas.

Kneipp, K. G.↗

Experiment K-7-31: Studies of Vestibular Primary Afferents and Eye Movements in Normal, Hypergravity and Hypogravity - Axon Cosmos Flight 2044

Fourteen days of active head movements in microgravity appear to modify the gain and neural adaptation properties of the horizontal semicircular canals in the rhesus monkey. This is the first demonstration of adaptive plasticity in the sensory receptor. Reversing prisms, for example, do not modify the gain of the primary afferent response. Pulse yaw rotation, sinusoidal rotation, and sum of sinusoidal rotation testing during the first day following recovery revealed that the gain of a sample of afferents was significantly greater than the gain derived from afferent responses obtained during pre-flight and control monkey testing. There was no strong evidence of tilt sensitivity in the sample of afferents that we tested either during the pre-flight or control tests or during the first day post-flight. Two irregular afferents tested on postflight day 2 showed changes with tilt but the responses were not systematic. The spontaneous discharge did not change following flight. Mean firing rate and coefficient of variation remained constant during the post flight tests and was near the value measured during pre flight tests. The change in gain of horizontal canal afferents might be adaptive. The animals were required to look at a target for food. This required active head and eye movements. Active head movements have been shown to be hypometric and eye movements have been shown to be hypermetric during the first few days of past Cosmos flights (see introduction). It might be that the increased gain in the horizontal semicircular canals permit accurate target acquisition during hypometric head movements by driving the eyes to greater angles for smaller angles of head movement. The mechanism by which the semicircular canals recalibrate (increase their gain) is unknown. The efferent vestibular system is a logical candidate. Horizontal nystagmus during rotation about an earth vertical axis with the horizontal semicircular canals in the plane of rotation produced the same response during postflight day 1 and post-flight day 9. But when the head was pitched down 45? the nystagmus slow phase velocity was greater and the duration was about twice during post-flight day 1. Apparently, this response involving the interaction of the horizontal and vertical semicircular canals and the otoliths did not recalibrate during post-flight day 1. The 'DC' bias of the slow phase velocity of the horizontal nystagmus during constant velocity horizontal axis rotation was roughly 4 times for one flight monkey and roughly 2 times for the other on post-flight day 1 compared to post-flight day 9. These results suggest that the otolith mediated response during constant velocity rotation also did not recalibrate on post-flight day 1.

Correia, M. J.↗

Planetary Hyperspectral Imager (PHI)

A hyperspectral imaging spectrometer was breadboarded. Key innovations were use of a sapphire prism and single InSb focal plane to cover the entire spectral range, and a novel slit optic and relay optics to reduce thermal background. Operation over a spectral range of 450 - 4950 nm (approximately 3.5 spectral octaves) was demonstrated. Thermal background reduction by a factor of 8 - 10 was also demonstrated.

Silvergate, Peter↗

Waveguides in Thin Film Polymeric Materials

Results on the fabrication of integrated optical components in polymeric materials using photo printing methods will be presented. Optical waveguides were fabricated by spin coating preoxidized silicon wafers with organic dye/polymer solution followed by soft baking. The waveguide modes were studied using prism coupling technique. Propagation losses were measured by collecting light scattered from the trace of a propagation mode by either scanning photodetector or CCD camera. We observed the formation of graded index waveguides in photosensitive polyimides after exposure of UV light from a mercury arc lamp. By using a theoretical model, an index profile was reconstructed which is in agreement with the profile reconstructed by the Wentzel-Kramers-Brillouin calculation technique using a modal spectrum of the waveguides. Proposed mechanism for the formation of the graded index includes photocrosslinking followed by UV curing accompanied with optical absorption increase. We also developed the prototype of a novel single-arm double-mode interferometric sensor based on our waveguides. It demonstrates high sensitivity to the chance of ambient temperature. The device can find possible applications in aeropropulsion control systems.

Sakisov, Sergey↗

Towards and FVE-FAC Method for Determining Thermocapillary Effects on Weld Pool Shape

Several practical materials processes, e.g., welding, float-zone purification, and Czochralski crystal growth, involve a pool of molten metal with a free surface, with strong temperature gradients along the surface. In some cases, the resulting thermocapillary flow is vigorous enough to convect heat toward the edges of the pool, increasing the driving force in a sort of positive feedback. In this work we examine this mechanism and its effect on the solid-liquid interface through a model problem: a half space of pure substance with concentrated axisymmetric surface heating, where surface tension is strong enough to keep the liquid free surface flat. The numerical method proposed for this problem utilizes a finite volume element (FVE) discretization in cylindrical coordinates. Because of the axisymmetric nature of the model problem, the control volumes used are torroidal prisms, formed by taking a polygonal cross-section in the (r, z) plane and sweeping it completely around the z-axis. Conservation of energy (in the solid), and conservation of energy, momentum, and mass (in the liquid) are enforced globally by integrating these quantities and enforcing conservation over each control volume. Judicious application of the Divergence Theorem and Stokes' Theorem, combined with a Crank-Nicolson time-stepping scheme leads to an implicit algebraic system to be solved at each time step. It is known that near the boundary of the pool, that is, near the solid-liquid interface, the full conduction-convection solution will require extremely fine length scales to resolve the physical behavior of the system. Furthermore, this boundary moves as a function of time. Accordingly, we develop the foundation of an adaptive refinement scheme based on the principles of Fast Adaptive Composite Grid methods (FAC). Implementation of the method and numerical results will appear in a later report.

Canright, David↗

The Extinction Properties of Heavily-Reddened Lines of Sight in the Galaxy

Recent studies of the 3.4 micron C-H stretch absorption feature indicate a strong correlation between it and the 10 micron silicate band over a wide range of extinctions (A(sub v) = 3.9-31 magnitudes), but the relationships between their optical depths and the visual extinction are particularly poorly constrained at intermediate extinctions between 15 and 20 magnitudes. The objective prism survey published by Stephenson may help to alleviate this difficulty. It lists more than 400 extremely red stars lacking molecular absorption bands, suggesting that these are hot blue stars reddened by long path lengths of the Galactic ISM. The intrinsic properties of these stars are unfortunately only loosely constrained, and JHK photometry therefore does not accurately determine the interstellar extinction. Using the POSS I plates, we have attempted to produce self-consistent spectral types, luminosity classes and extinctions for the stars which Stephenson claims to be most heavily reddened. 14 out of 25 sources studied are consistent with OB supergiants. The results are highly sensitive to upper limits in the blue plate, and are not always consistent with Stephenson's claims of much higher reddening than that of a typical member of the Cygnus OB2 association. For the most heavily-reddened sources studied, a B-magnitude based on the faintest measurable value on the blue plate yielded a lower limit of about 9 magnitudes on the extinction.

Rawlings, M. G.↗