Search NASA⌕ Search

SEARCH · Search NASA

Results for “Performance Deviation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Pre-Transient Characterization of MLOF-1 Test Pin

This study focuses on the pre-transient characterization of U-10Zr test and sibling fuel pins for the THOR-M-LOF test series. Using neutron radiography, element contact profilometry (ECP), precise gamma scan (PGS), and gas assay, sampling, and recharge (GASR) analysis, it was confirmed that the fuel pins were intact and suitable for testing. Key fuel behaviors quantified include axial elongation, diametral strain, fluff structure geometry, axial isotope distribution, and fission gas release. Any deviations from historically expected behaviors were investigated and attributed to factors other than the irradiation behavior of the fuel pin. These pre-transient measurements establish a baseline for future post-transient analysis, which will be used to inform fuel performance models and safety criteria for sodium-cooled fast reactors (SFRs). The results will enhance understanding of transient fuel behavior and expand limited data on LOF scenarios.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Oversizing and Part-Load Problems

Oversizing, the common engineering practice of specifying devices with capacity exceeding the actual load requirement, is a widespread practice across virtually all building technologies end-use categories, including HVAC, electrical systems, lighting, appliances, and plug loads. This practice, driven by factors like design uncertainty, institutional pressures, and risk aversion, results in wasted capital investment, control difficulties, and excessive energy consumption due to inefficient part-load operation. Part-load operation, where devices run below maximum capacity, is the dominant operating mode in most energy systems and presents a complex design challenge. Solutions to match output to load fall into three broad categories: constraining the output, adjusting the device’s internal behavior, and linking output to energy storage or other waste-heat reuse applications. The energy implications of part-load are critical, as efficiency often drops sharply as load decreases across a wide diversity of devices. To quantify the extent of this problem, we derive a dimensionless Part-Load Metric (PLM) based on device efficiency and its frequency distribution of operating hours at various output levels. The PLM quantifies the deviation of a device's actual efficiency from its maximum design efficiency. This metric also serves as a measure of "capital inefficiency," enabling engineers to compare the impact of different part-load solutions and providing a unified framework for evaluating performance across various devices and systems.

Meier, Alan↗

Search for New Physics in the B0(s) mixing phase

The Collider Detector at Fermilab (CDF) experiment performed the first measurement of the time-evolution of flavor-tagged B{sub s}{sup 0} {yields} J/{psi}{phi} decays, which probes mixing-induced CP-violation in the B{sub s}{sup 0} sector. Any sizable deviation from zero of the phase {beta}{sub s}J/{psi}{phi}, accessible through interference of the {bar b} {yields} {bar c}c{bar s} quark-level process accompanied or not by B{sub s}{sup 0}-{bar B}{sub s}{sup 0} mixing, would be unambiguous indication of physics beyond the Standard Model. I report CDF results obtained in 1.35 fb{sup -1}, a recent extension to a larger dataset corresponding to 2.8 fb{sup -1}, and future projections.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Extension of the possibilities of a commercial digital camera in detecting spatial intensity distribution of laser radiation

Performance capabilities of commercial digital cameras are demonstrated by the example of a Canon EOS 400D camera in measuring and detecting spatial distributions of laser radiation intensity. It is shown that software extraction of linear data expands the linear dynamic range of the camera by a factor greater than 10, up to 58 dB. Basic measurement characteristics of the camera are obtained in the regime of linear data extraction: the radiometric function, deviation from linearity, dynamic range, temporal and spatial noises (both dark and those depending on the signal value). The parameters obtained correspond to those of technical measuring cameras. (measurement of laser radiation parameters)

42 ENGINEERING↗

Secondary particle emission from a ferromagnetic binary compound

Secondary ion emission from an ion-bombarded binary compound in the ferro- and paramagnetic states has been studied using experimental methods and molecular dynamics simulations. The experiments were performed with a widely used NiPd binary compound, which was bombarded by obliquely incident 10-keV Ar ions. It is established that the intensity of Ni{sup +} and Pd{sup +} ion emission from a polycrystalline NiPd sample decreases significantly when it passes from the ferromagnetic to paramagnetic state. This effect is explained by a change in the surface binding energy and density of surface states at the Fermi level and by a cumulative process related to sputtering. The energies and directions of emission of secondary particles from poly- and single-crystalline NiPd samples in the ferromagnetic state have been jointly studied. It is established that the maximum of the polar angular distribution of secondary particles deviates toward the normal to the irradiated surface with a decrease in their energy. A difference in the azimuthal distribution of emitted Ni and Pd particles has been observed during the bombardment of a (001)NiPd crystal face and explained by specific features of correlated collisions. The best agreement of experimental data with the results of molecular dynamics simulations is obtained if the calculations are performed with allowance for an experimentally established modified composition of the three uppermost surface layers [39].

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Technical Note: Image filtering to make computer-aided detection robust to image reconstruction kernel choice in lung cancer CT screening

Purpose: In lung cancer computed tomography (CT) screening, the performance of a computer-aided detection (CAD) system depends on the selection of the image reconstruction kernel. To reduce this dependence on reconstruction kernels, the authors propose a novel application of an image filtering method previously proposed by their group. Methods: The proposed filtering process uses the ratio of modulation transfer functions (MTFs) of two reconstruction kernels as a filtering function in the spatial-frequency domain. This method is referred to as MTF{sub ratio} filtering. Test image data were obtained from CT screening scans of 67 subjects who each had one nodule. Images were reconstructed using two kernels: f{sub STD} (for standard lung imaging) and f{sub SHARP} (for sharp edge-enhancement lung imaging). The MTF{sub ratio} filtering was implemented using the MTFs measured for those kernels and was applied to the reconstructed f{sub SHARP} images to obtain images that were similar to the f{sub STD} images. A mean filter and a median filter were applied (separately) for comparison. All reconstructed and filtered images were processed using their prototype CAD system. Results: The MTF{sub ratio} filtered images showed excellent agreement with the f{sub STD} images. The standard deviation for the difference between these images was very small, ∼6.0 Hounsfield units (HU). However, the mean and median filtered images showed larger differences of ∼48.1 and ∼57.9 HU from the f{sub STD} images, respectively. The free-response receiver operating characteristic (FROC) curve for the f{sub SHARP} images indicated poorer performance compared with the FROC curve for the f{sub STD} images. The FROC curve for the MTF{sub ratio} filtered images was equivalent to the curve for the f{sub STD} images. However, this similarity was not achieved by using the mean filter or median filter. Conclusions: The accuracy of MTF{sub ratio} image filtering was verified and the method was demonstrated to be effective for reducing the kernel dependence of CAD performance.

60 APPLIED LIFE SCIENCES↗

Impedance Characteristics and Polarization Behavior of a Microbial Fuel Cell in Response to Short-Term Changes in Medium pH

pH oppositely influences anode and cathode performance in microbial fuel cells. The differential electrochemical effects at each electrode and the resultant full-cell performance were analyzed in medium pH from 6.0 to 8.0. Potentials changed -60 mV/pH for the anode and -68 mV/pH for the cathode, coincident with thermodynamic estimations. Open circuit voltage reached a maximum (741 mV) at pH 7, and maximum power density was highest (712 mW/m{sup 2}) at pH 6.5 as the cathode performance improved at lower pH. Maximum current density increased and apparent half-saturation potential (E{sub KA}) decreased with increasing medium pH due to improved anode performance. An equivalent circuit model composed of two time constant processes accurately fit bioanode impedance data. One of these processes was consistently the rate-limiting step for acetate-oxidizing exoelectrogenesis, with its pH-varying charge transfer resistance R{sub 2} ranging from 2- to 321-fold higher than the pH-independent charge transfer resistance R{sub 1}. The associated capacitance C{sub 2} was 2-3 orders of magnitude larger than C{sub 1}. R{sub 2} was lowest near E{sub KA} and increased by several orders of magnitude at anode potentials above E{sub KA}, while R{sub 1} was nearly stable. However, fits deviated slightly at potentials above E{sub KA} due to emerging impedance possibly associated with diffusion and excessive potential.

30 DIRECT ENERGY CONVERSION↗

Annual Summary Report for the Remote-Handled Low-Level Waste Disposal Facility—FY 2025

The U.S. Department of Energy (DOE) requires the performance assessment (PA) (Department of Energy Idaho Operations Office [DOE-ID] 2018a), composite analysis (CA) (DOE-ID 2012), and CA addendum (DOE-ID 2018b) for the Remote-Handled Low-Level Waste (RHLLW) Disposal Facility at the Idaho National Laboratory (INL) Site shall be maintained to evaluate changes that could affect the performance, design, and operating basis for the facility (DOE Manual 435.1-1 Change 3, “Radioactive Waste Management Manual,” Section IV.P. [4]). The RHLLW Disposal Facility became operational in September 2018 after the completion of operational readiness activities required by DOE Order 425.1D, “Verification of Readiness to Start Up or Restart Nuclear Facilities,” and the issuance of the startup authorization by the Startup Approval Authority (Boston 2018). The first waste disposals at the RHLLW Disposal Facility began in Fiscal Year (FY) 2019. In Fiscal Year (FY) 2025, no significant operational changes or other activities occurred that would cause deviation from the assumptions in the PA and CA pertaining to disposal geometry, verification of waste characteristics, tracking disposal inventories against total limits, facility closure design, or institutional controls. This FY 2025 annual summary report (ASR) documents the continued adequacy of the PA, CA, operating disposal authorization statement (ODAS) (ODAS 2018), ODAS technical-basis documents, and the radioactive waste management basis (RWMB) (INL 2024a) to meet DOE Order 435.1, “Radioactive Waste Management,” performance objectives for the RHLLW Disposal Facility. Annual review of the adequacy of the PA and CA at the RHLLW Disposal Facility ensures that conclusions of the analyses remain valid in accordance with requirements of DOE Order 435.1.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

FUNDAMENTAL PERFORMANCE OF A DISPERSED FIXED DELAY INTERFEROMETER IN SEARCHING FOR PLANETS AROUND M DWARFS

We present a new method to calculate fundamental Doppler measurement limits with a dispersed fixed delay interferometer (DFDI) in the near-infrared (NIR) wavelength region for searching for exoplanets around M dwarfs in the coming decade. It is based on calculating the Q factor, a measure of flux-normalized Doppler sensitivity in the fringing spectra created with DFDI. We calculate the Q factor as a function of spectral resolution R, stellar-projected rotational velocity Vsin i, stellar effective temperature T{sub eff}, and optical path difference (OPD) of the interferometer. We also compare the DFDI Q factor to that for the popular cross-dispersed echelle spectrograph method (the direct echelle (DE) method). We find that (1) Q{sub DFDI} is a factor of 1.5-3 higher than Q{sub DE} at R ranging from 5000 to 20,000; (2) Q{sub DFDI} and Q{sub DE} converge at a very high R (R {>=} 100,000); (3) Q{sub DFDI} increases as R increases and Vsin i deceases; (4) for a given R, Q{sub DFDI} increases as T{sub eff} drops from 3100 K to 2400 K (M4V to M9V). We also investigate how Q{sub DFDI} is affected by OPD and find that a 5 mm deviation from the optimal OPD does not significantly affect Q{sub DFDI} (10% or less) for a wide range of R. Given that the NIR Doppler measurement is likely to be detector-limited for a while, we introduce new merit functions, which is directly related to photon-limited radial velocity (RV) uncertainty, to evaluate Doppler performance with the DFDI and DE methods. We find that DFDI has strength in wavelength coverage and multi-object capability over the DE for a limited detector resource. We simulate the performance of the InfraRed Exoplanet Tracker (IRET) based on the DFDI design, being considered for the next generation IR Doppler measurements. The predicted photon-limited RV uncertainty suggests that IRET is capable of detecting Earth-like exoplanets in habitable zone around nearby bright M dwarfs if they exist. A new method is developed to quantitatively estimate the influence of telluric lines on RV uncertainty. Our study shows that photon-limited RV uncertainty can be reached if 99% of the strength of telluric lines can be removed from the measured stellar spectra. At low to moderate levels of telluric line strength removal (50%-90%), the optimal RV uncertainty is typically a factor of two to three times larger than photon-limited RV uncertainty.

79 ASTRONOMY AND ASTROPHYSICS↗

Noise spatial nonuniformity and the impact of statistical image reconstruction in CT myocardial perfusion imaging

Purpose: To achieve high temporal resolution in CT myocardial perfusion imaging (MPI), images are often reconstructed using filtered backprojection (FBP) algorithms from data acquired within a short-scan angular range. However, the variation in the central angle from one time frame to the next in gated short scans has been shown to create detrimental partial scan artifacts when performing quantitative MPI measurements. This study has two main purposes. (1) To demonstrate the existence of a distinct detrimental effect in short-scan FBP, i.e., the introduction of a nonuniform spatial image noise distribution; this nonuniformity can lead to unexpectedly high image noise and streaking artifacts, which may affect CT MPI quantification. (2) To demonstrate that statistical image reconstruction (SIR) algorithms can be a potential solution to address the nonuniform spatial noise distribution problem and can also lead to radiation dose reduction in the context of CT MPI. Methods: Projection datasets from a numerically simulated perfusion phantom and an in vivo animal myocardial perfusion CT scan were used in this study. In the numerical phantom, multiple realizations of Poisson noise were added to projection data at each time frame to investigate the spatial distribution of noise. Images from all datasets were reconstructed using both FBP and SIR reconstruction algorithms. To quantify the spatial distribution of noise, the mean and standard deviation were measured in several regions of interest (ROIs) and analyzed across time frames. In the in vivo study, two low-dose scans at tube currents of 25 and 50 mA were reconstructed using FBP and SIR. Quantitative perfusion metrics, namely, the normalized upslope (NUS), myocardial blood volume (MBV), and first moment transit time (FMT), were measured for two ROIs and compared to reference values obtained from a high-dose scan performed at 500 mA. Results: Images reconstructed using FBP showed a highly nonuniform spatial distribution of noise. This spatial nonuniformity led to large fluctuations in the temporal direction. In the numerical phantom study, the level of noise was shown to vary by as much as 87% within a given image, and as much as 110% between different time frames for a ROI far from isocenter. The spatially nonuniform noise pattern was shown to correlate with the source trajectory and the object structure. In contrast, images reconstructed using SIR showed a highly uniform spatial distribution of noise, leading to smaller unexpected noise fluctuations in the temporal direction when a short scan angular range was used. In the numerical phantom study, the noise varied by less than 37% within a given image, and by less than 20% between different time frames. Also, the noise standard deviation in SIR images was on average half of that of FBP images. In the in vivo studies, the deviation observed between quantitative perfusion metrics measured from low-dose scans and high-dose scans was mitigated when SIR was used instead of FBP to reconstruct images. Conclusions: (1) Images reconstructed using FBP suffered from nonuniform spatial noise levels. This nonuniformity is another manifestation of the detrimental effects caused by short-scan reconstruction in CT MPI. (2) Images reconstructed using SIR had a much lower and more uniform noise level and thus can be used as a potential solution to address the FBP nonuniformity. (3) Given the improvement in the accuracy of the perfusion metrics when using SIR, it may be desirable to use a statistical reconstruction framework to perform low-dose dynamic CT MPI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Radiofrequency Ablation of Osteoid Osteomas with Use of Real-Time Needle Guidance for Accurate Needle Placement: A Pilot Study

Purpose: To evaluate the accuracy and technical success of positioning a radiofrequency ablation (RFA) electrode in osteoid osteomas by use of a new real-time needle guidance technology combining cone-beam computed tomography (CT) and fluoroscopy. Materials and Methods: Percutaneous RFA of osteoid osteomas was performed in five patients (median age 18 years), under general anesthesia, with the use of cone-beam CT and fluoroscopic guidance for electrode positioning. The outcome parameters were technical success, meaning correct needle placement in the nidus; accuracy defined as the deviation (in mm) from the center of the nidus; and clinical outcome at follow-up. Results: In all five cases, positioning was possible within 3 mm of the determined target location (median nidus size 6.8 mm; range 5-10.2 mm). All procedures were technically successful. All patients were free of pain at clinical follow-up. No complications were observed. Conclusion: Real-time fluoroscopy needle guidance based on cone-beam CT is a useful tool to accurately position radiofrequency needles for minimally invasive treatment of osteoid osteomas.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Kilovoltage Cone-Beam Computed Tomography With Megavoltage Projection Pairs for Paraspinal Radiosurgery Patient Alignment and Position Verification

Purpose: Implanted gold markers and megavoltage (MV) portal imaging are commonly used for setup verification of paraspinal tumors treated with high-dose, single-fraction radiotherapy. We investigated whether the use of kilovoltage cone-beam computed tomography (CBCT) imaging eliminates the need for marker implantation. Methods and Materials: Patients with paraspinal disease who were eligible for single-fraction stereotactic body radiotherapy were accrued to an institutional review board-approved protocol. Each of 16 patients underwent implantation of fiducial markers near the target. The markers were visible on the MV images. Three MV image pairs were acquired for each patient (initial, verification, and final) and were registered to the reference images. Every MV pair was complemented by a CBCT scan. CBCT image registration was performed automatically by maximizing the mutual information using a region of interest that excluded the markers. The corrections, as determined from the MV images, were compared with these from CBCT and were used for actual patient setup. Results: The mean and standard deviation of the absolute values of the differences between the CBCT and MV corrections were 1.0 {+-} 0.7, 1.0 {+-} 0.6, and 1.0 {+-} 0.8 mm for the left-right, anteroposterior, and superoinferior directions, respectively. The absolute differences between the corresponding pre- and post-treatment kilovoltage CBCT image registration were 0.6 {+-} 0.5, 0.6 {+-} 0.5, and 1.0 {+-} 0.8 mm. Conclusion: The setup corrections found using CBCT without the use of implanted markers were consistent with the marker registration on MV projections. CBCT has additional advantages, including better positioning precision and robust automatic three-dimensional registration, as well as eliminating the need for invasive marker implantation. We have adopted CBCT for the setup of all single-fraction paraspinal patients. Our data have also demonstrated that target displacements during treatment are insignificant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of the {sup 3}He-{eta} interaction

We present a summary of measurements of the dp{yields}{sup 3}HeX,(X {pi}{sup 0},{eta}) reactions performed with the COSY-11 facility. Our results for the dp{yields}{sup 3}He{eta} total cross sections confirm a strong enhancement observed in previous experiments close to the kinematical threshold. The forward-backward asymmetries of the differential cross sections deviate clearly from zero for center of mass momenta above 50 MeV/c indicating the presence of higher partial waves in the final state. The excitation function for the reaction dp{yields}{sup 3}He{pi}{sup 0} does not show any structure which could originate from the decay of the {sup 3}He-{eta} bound state. Our measurements do not confirm the cusp structure observed in the threshold excitation curve measured with the SPES-4 spectrometer in the vicinity of the {eta} production threshold.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dimensional Control of Micro Components with Synchrotron Computed Tomography

An advantage of Computed Tomography (CT) is the coordinate measurement capability of small inner structures, which are not accessible with classical measurement techniques. Using the advantages of synchrotron radiation CT measurements of parts with sizes of a few millimeters are performed at BAMline of BESSY II and are expected to be used as references for further dimensional measurements with micro CT. Previous investigations were focused on external gears, which are accessible with standard Coordinate Measurement Machines (CMMs). To obtain information about the accuracy of dimensional measurements of internal gears with CT, reference data have been measured by a tactile-optical CMM. This information is used to evaluate the performance of the CT. In addition to the first results for the evaluation of internal gear flanks, new measurements of different gear materials (steel and zirconium dioxide) will be presented. For functional evaluation, gear flanks are a matter of particular interest. Form deviations are analyzed with respect to the different gear materials to establish CT measurements as technology in the field of quality assurance and to compare the different manufacturing processes.

07 ISOTOPE AND RADIATION SOURCES↗

Estimation Of Charge Transport Parameters And Equivalent Circuit For Poly Alkyl Thiophene Field-Effect Transistors

The small signal ac response is measured across the source-drain terminals of organic field-effect transistors (OFET) under dc bias to obtain the equivalent circuit parameters of poly (2,5-bis(3-tetradecylthiophen-2-yl)thieno[3,2-b]thiophene)(PBTTT) and poly(3-hexyl thiophene)(P3HT) based devices. The numerically simulated response based on these parameters is in good agreement with the experimental data for PBTTT-FET except at low frequencies, while the P3HT-FET data show significant deviations. This indicates that the interface with the metal electrode is rather complex for the latter, involving additional circuit elements arising from contact impedance or charge injection processes. Such an investigation can help in identifying the operational bottlenecks and to improve the performance of OFETs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Raman scattering by the E{sub 2h} and A{sub 1}(LO) phonons of In{sub x}Ga{sub 1-x}N epilayers (0.25 < x < 0.75) grown by molecular beam epitaxy

We use Raman scattering to investigate the composition behavior of the E{sub 2h} and A{sub 1}(LO) phonons of In{sub x}Ga{sub 1-x}N and to evaluate the role of lateral compositional fluctuations and in-depth strain/composition gradients on the frequency of the A{sub 1}(LO) bands. For this purpose, we have performed visible and ultraviolet Raman measurements on a set of high-quality epilayers grown by molecular beam epitaxy with In contents over a wide composition range (0.25 < x < 0.75). While the as-measured A{sub 1}(LO) frequency values strongly deviate from the linear dispersion predicted by the modified random-element isodisplacement (MREI) model, we show that the strain-corrected A{sub 1}(LO) frequencies are qualitatively in good agreement with the expected linear dependence. In contrast, we find that the strain-corrected E{sub 2h} frequencies exhibit a bowing in relation to the linear behavior predicted by the MREI model. Such bowing should be taken into account to evaluate the composition or the strain state of InGaN material from the E{sub 2h} peak frequencies. We show that in-depth strain/composition gradients and selective resonance excitation effects have a strong impact on the frequency of the A{sub 1}(LO) mode, making very difficult the use of this mode to evaluate the strain state or the composition of InGaN material.

36 MATERIALS SCIENCE↗

On the use of the proximity force approximation for deriving limits to short-range gravitational-like interactions from sphere-plane Casimir force experiments

We discuss the role of the proximity force approximation in deriving limits to the existence of Yukawian forces--predicted in the submillimeter range by many unification models--from Casimir force experiments using the sphere-plane geometry. Two forms of this approximation are discussed, the first used in most analyses of the residuals from the Casimir force experiments performed so far, and the second recently discussed in this context in R. Decca et al.[Phys. Rev. D 79, 124021 (2009)]. We show that the former form of the proximity force approximation overestimates the expected Yukawa force and that the relative deviation from the exact Yukawa force is of the same order of magnitude, in the realistic experimental settings, as the relative deviation expected between the exact Casimir force and the Casimir force evaluated in the proximity force approximation. This implies both a systematic shift making the actual limits to the Yukawa force weaker than claimed so far, and a degree of uncertainty in the {alpha}-{lambda} plane related to the handling of the various approximations used in the theory for both the Casimir and the Yukawa forces. We further argue that the recently discussed form for the proximity force approximation is equivalent, for a geometry made of a generic object interacting with an infinite planar slab, to the usual exact integration of any additive two-body interaction, without any need to invoke approximation schemes. If the planar slab is of finite size, an additional source of systematic error arises due to the breaking of the planar translational invariance of the system, and we finally discuss to what extent this may affect limits obtained on power-law and Yukawa forces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Möbius domain-wall fermions on gradient-flowed dynamical HISQ ensembles

We report on salient features of a mixed lattice QCD action using valence Möbius domain-wall fermions solved on the dynamical 𝑁 𝑓 = 2 + 1 + 1 highly improved staggered quark sea-quark ensembles generated by the MILC Collaboration. The approximate chiral symmetry properties of the valence fermions are shown to be significantly improved by utilizing the gradient-flow scheme to first smear the highly improved staggered quark configurations. The greater numerical cost of the Möbius domain-wall inversions is mitigated by the highly efficient QUDA library optimized for NVIDIA GPU accelerated compute nodes. We have created an interface to this optimized QUDA solver in Chroma. We provide tuned parameters of the action and performance of QUDA using ensembles with the lattice spacings 𝑎 ≃ {0.15,0.12,0.09} fm and pion masses 𝑚 𝜋 ≃ {310,220,130} MeV. We have additionally generated two new ensembles with 𝑎 ∼ 0.12 fm and 𝑚 𝜋 ∼ {400,350} MeV. Furthermore, with a fixed flow time of 𝑡 𝑔⁡𝑓 =1 in lattice units, the residual chiral symmetry breaking of the valence fermions is kept below 10% of the light quark mass on all ensembles, 𝑚 res ≲ 0.1 × 𝑚 𝑙 , with moderate values of the fifth dimension 𝐿 5 and a domain-wall height 𝑀 5 ≤ 1.3. As a benchmark calculation, we perform a continuum, infinite volume, physical pion and kaon mass extrapolation of 𝐹 𝐾 ±⁡ /𝐹 𝜋 ± and demonstrate our results are independent of flow time and consistent with the FLAG determination of this quantity at the level of less than one standard deviation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗