Search NASA⌕ Search

SEARCH · Search NASA

Results for “Phased Array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Ultrananocrystalline diamond films with optimized dielectric properties for advanced RF MEMS capacitive switches

An efficient deposition process is provided for fabricating reliable RF MEMS capacitive switches with multilayer ultrananocrystalline (UNCD) films for more rapid recovery, charging and discharging that is effective for more than a billion cycles of operation. Significantly, the deposition process is compatible for integration with CMOS electronics and thereby can provide monolithically integrated RF MEMS capacitive switches for use with CMOS electronic devices, such as for insertion into phase array antennas for radars and other RF communication systems.

36 MATERIALS SCIENCE↗

An Empirical Study on Ultrasonic Testing in Lieu of Radiography for Nuclear Power Plants

Research is being conducted for the U.S. Nuclear Regulatory Commission (NRC) at the Pacific Northwest National Laboratory (PNNL) to assess the capability, effectiveness, and reliability of ultrasonic testing (UT) as a replacement method for radiographic testing (RT) for inspecting nuclear power plant (NPP) components. A primary objective of this work is to evaluate UT techniques to assess their ability to detect, locate, size, and characterize fabrication flaws in typical NPP weldments. This particular study focused on the evaluation of four carbon steel pipe-to-pipe welds on specimens that ranged in thicknesses from 19.05 mm (0.75 in.) to 27.8 mm (1.094 in.) and were 355.6 mm (14.0 in.) or 406.4 mm (16.0 in.) in diameter. The pipe welds contained both implanted (intentional) fabrication flaws as well as bonus (unintentional) flaws throughout the entire thickness of the weld and the adjacent base material. The fabrication flaws were a combination of planar and volumetric flaw types, including incomplete fusion, incomplete penetration, cracks, porosity, and slag inclusions. The examinations were conducted using phased-array UT (PA UT) techniques applied primarily for detection and length sizing of the flaws. Radiographic examinations were also conducted on the specimens with RT detection and length sizing results being used to establish true state. This paper will discuss the comparison of UT and RT (true state) detection results conducted to date along with a discussion on the technical gaps that need to be addressed before these methods can be used interchangeably for repair and replacement activities for NPP components.

NDE reliability↗

Primary Water Stress Corrosion Cracks in Nickel Alloy Dissimilar Metal Welds: Detection and Sizing Using Established and Emerging Nondestructive Examination Techniques

The U.S. Nuclear Regulatory Commission has established the Program to Assess the Reliability of Emerging Nondestructive Techniques (PARENT) as a follow-on to the international cooperative Program for the Inspection of Nickel Alloy Components (PINC). The goal of PINC was to evaluate the capabilities of various nondestructive evaluation (NDE) techniques to detect and characterize surface-breaking primary water stress corrosion cracks in dissimilar-metal welds (DMW) in bottom-mounted instrumentation (BMI) penetrations and small-bore (≈400-mm diameter) piping components. A series of international blind round-robin tests were conducted by commercial and university inspection teams. Results from these tests showed that a combination of conventional and phased-array ultrasound techniques provided the highest performance for flaw detection and depth sizing in dissimilar metal piping welds. The effective detection of flaws in BMIs by eddy current and ultrasound shows that it may be possible to reliably inspect these components in the field. The goal of PARENT is to continue the work begun in PINC and apply the lessons learned to a series of open and blind international round-robin tests that will be conducted on a new set of piping components including large-bore (≈900-mm diameter) DMWs, small-bore DMWs, and BMIs. Open round-robin testing will engage universities and industry worldwide to investigate the reliability of emerging NDE techniques to detect and accurately size flaws having a wide range of lengths, depths, orientations, and locations. Blind round-robin testing will invite testing organizations worldwide, whose inspectors and procedures are certified by the standards for the nuclear industry in their respective countries, to investigate the ability of established NDE techniques to detect and size flaws whose characteristics range from easy to very difficult to detect and size. This paper presents highlights of PINC and reports on the plans and progress for PARENT round-robin tests.

cracks↗

On Success Probability of Eavesdropping Attack in 802.11ad mmWave WLAN

Next generation wireless communication networks utilizing 60 GHz millimeter wave (mmWave) frequency bands are expected to achieve multi-gigabit throughput with the use of highly directional phased-array antennas. These directional signal beams provide enhanced security to the legitimate networks due to the increased difficulties of eavesdropping. However, there still exists significant possibility of eavesdropping since (i) the reflections of the signal beam from ambient reflectors enables opportunistic stationary eavesdropping attacks; and (ii) carefully designed beam exploration strategy enables active nomadic eavesdropping attack. This paper discusses eavesdropper attack strategies for 802.11ad mmWave systems and provides the first analytical model to characterize the success possibility of eavesdropping in both opportunistic stationary attacks and active nomadic attacks.

99 GENERAL AND MISCELLANEOUS↗

Overview of TAE technologies’ HHFW project on LAPD

Simulation survey performed at TAE Technologies, has demonstrated that high harmonic fast wave (HHFW) heating is a promising scenario to heat core electrons of FRC plasma. To prepare the proposed experimental study of HHFW antenna-plasma coupling and wave propagation on LAPD machine at UCLA, a high-power-capable 4-strap antenna has been calculated and designed through collaboration among TAE, ORNL, ASIPP, and UCLA. This antenna was mechanically designed and fabricated by ASIPP and it has been installed recently on LAPD. Meanwhile, by using the Petra-M code, a newly developed generic electromagnetic simulation tool for modeling RF wave propagation, the RF-SciDAC team starts 3D full wave simulations. Detailed information on antenna electromagnetic simulations and mechanical design, as well as preliminary experimental results of wave propagation study with the newly installed phased- array antenna, will be presented in this paper.REFE

Yang, Xiaokang↗

An Innovative Secure mmWave M2M Communication Network for Operating Drones

Analyze RF (Radio Frequency) coverage in the sky with the innovative use of mmWave phased arrays aimed towards the drone corridor to harness the power of 5G – multiplicative improvement in data throughput & reduction in latency, and support of massive M2M communications. Apply MA (Multiple Access) technology to increase the spectral efficiency by covering a swarm of drones with a single mmWave beam and associated radio resources. Design energy efficient low-bit quantization to form mmWave beams for drone operation. Use drones’ navigation capabilities to significantly improve security by e.g. evading attackers. Utilize intra-drone communication to improve reliability as well as security. Demonstrate the simulated recovery of a critical infrastructure such as a power grid that requires a black restart with mmWave modeling and experiments .

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Sub-nanosecond RF synchronization for MIMO software defined radio sensor networks

This disclosure presents distributed and decentralized synchronization for wireless transceivers. The disclosed system, device, and method achieve sub-nanosecond synchronization using low-cost commercial off the shelf software defined radios. By providing a decentralized mechanism that does not rely on a hierarchical master-slave structure, networks constructed as disclosed are robust to sensor drop-out in contested or harsh environments. Such networks may be used to create phased array radars and communication systems without requiring wired connections to distribute a common clock or local oscillator reference.

Moghaddam, Mahta↗

Inspection Technology Advancements for Hanford Double Shell Tank Integrity Verification - 16150

The Hanford double-shell tanks (DSTs) were constructed in southeastern Washington State between 1968 and 1986 to store nuclear waste. Most of the tank waste came from the Hanford nuclear weapons program, which has been stopped for more than 25 years. The tanks will be needed for many years to come until suitable vitrification and permanent storage solutions are developed. These tanks are nominally 45 ft. deep from the dome peak to the floor. The inner tank is nominally 75 ft. dia. and the outer tank is nominally 80 ft. dia., leaving a 2.5 ft. annulus between the two side tank walls. The waste management program (under direction of Washington River Protection Solutions, WRPS) manages inspections of these DSTs from the annulus to justify their continued safe service and to avoid the high cost of new replacement tanks. Over time, the Hanford Tank Farm contractors, currently WRPS, have increased their ultrasound inspections of these tanks. Pacific Northwest National Laboratory has worked with the Hanford Tank Farm contractors for more than 15 years to advance applicable tank nondestructive inspection technology for improved performance and cost reduction. Past, present, and planned technology advancements are addressed in this paper, including tank wall ultrasonic testing examination, extreme value statistical analysis, phased array for the tank wall, transmit/receive tandem synthetic aperture focusing technique knuckle examination, and electromagnetic acoustic transducer screening of the tank wall including mill-scale compensation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Progress on Advancing Robotic Ultrasonic Volumetric Inspection Technology for Hanford Under-tank Inspection - 19474

The Hanford River Protection Project is reliant on safe interim storage of high-level waste at the Hanford site and will continue to depend on it until the waste has been treated and vitrified by the Hanford Waste Treatment and Immobilization Plant (WTP). The Hanford double-shell tanks (DSTs) have provided interim storage since the DSTs were put into service (1971 - 1986) and the RPP will continue to rely on their service until least 2050, at which time the 27 in-service DSTs will be 14-54 years beyond their original design lives. As the DSTs continue to age and be operated beyond design life, reliable leak integrity assessments of primary tanks and secondary liners will become increasingly important in order to provide situational awareness to tank operations personnel and to support risk-informed decisions on the selection of DSTs as waste feed staging tanks and the order and timing of future DST refurbishment or, alternatively, DST retrieval sequence. This paper summarizes progress made in fiscal year (FY) 2018 on the engineering of a robotic air-slot volumetric inspection system (RAVIS) that is designed to perform ultrasonic (volumetric) leak integrity inspections of physically inaccessible primary tank bottom plates and welds. Leak integrity inspections performed with the RAVIS will supplement today's primary tank leak integrity inspections, which are currently limited to physically accessible sidewall plates and welds. The RAVIS will be deployed into air slots of the insulating concrete (refractory) pad beneath the primary tanks and use its ultrasonic guided wave phased-array (GWPA) sensor to electronically steer an ultrasonic beam 360-degrees around the sensor to volumetrically examine adjacent carbon steel plates and welds covered by refractory pad material. Deployments of RAVIS down multiple air-slots will be performed to determine which regions of a tank bottom have sound leak integrity or which regions are in need of future wall thickness restoration or weld repair due to pitting corrosion, general corrosion, or heat/stress-induced cracks. The initial RAVIS design and the flaw detection test results for the first air-slot GWPA sensor that was designed to fit inside the air-slots will be presented in this paper. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimating Transmitted-Signal Phase Variations for Uplink Array Antennas

A method of estimating phase drifts of microwave signals distributed to, and transmitted by, antennas in an array involves the use of the signals themselves as phase references. The method was conceived as part of the solution of the problem of maintaining precise phase calibration required for proper operation of an array of Deep Space Network (DSN) antennas on Earth used for communicating with distant spacecraft at frequencies between 7 and 8 GHz. The method could also be applied to purely terrestrial phased-array radar and other radio antenna array systems. In the DSN application, the electrical lengths (effective signal-propagation path lengths) of the various branches of the system for distributing the transmitted signals to the antennas are not precisely known, and they vary with time. The variations are attributable mostly to thermal expansion and contraction of fiber-optic and electrical signal cables and to a variety of causes associated with aging of signal-handling components. The variations are large enough to introduce large phase drifts at the signal frequency. It is necessary to measure and correct for these phase drifts in order to maintain phase calibration of the antennas. A prior method of measuring phase drifts involves the use of reference-frequency signals separate from the transmitted signals. A major impediment to accurate measurement of phase drifts over time by the prior method is the fact that although DSN reference-frequency sources separate from the transmitting signal sources are stable and accurate enough for most DSN purposes, they are not stable enough for use in maintaining phase calibrations, as required, to within a few degrees over times as long as days or possibly even weeks. By eliminating reliance on the reference-frequency subsystem, the present method overcomes this impediment. In a DSN array to which the present method applies (see figure), the microwave signals to be transmitted are generated by exciters in a signal-processing center, then distributed to the antennas via optical fibers. At each antenna, the signals are used to drive a microwave power-amplifier train, the output of which is coupled to the antenna for transmission. A small fraction of the power-amplifier-train output is sent back to the signal-processing center along another optical fiber that is part of the same fiber-optic cable used to distribute the transmitted signal to the antenna. In the signal-processing center, the signal thus returned from each antenna is detected and its phase is compared with the phase of the signal sampled directly from the corresponding exciter. It is known, from other measurements, that the signal-propagation path length from the power-amplifier-train output port to the phase center of each antenna is sufficiently stable and, hence, that sampling the signal at the power-amplifier-train output port suffices for the purpose of characterizing the phase drift of the transmitted signal at the phase center of the antenna

Paal, Leslie↗

Preparation N-F-codoped TiO{sub 2} nanorod array by liquid phase deposition as visible light photocatalyst

Research highlights: {yields} The formation of N, F-codoped TiO{sub 2} nanorod arrays via the LPD. {yields} Calcination temperature greatly effects the incorporation of N and F into TiO{sub 2}. {yields} TNRAs calcined at 450 {sup o}C showed highest visible light photocatalytic activity. {yields} A synergetic effect of 1D nanorod arrays and appropriate amount of N and F codoping. -- Abstract: An efficient method for the preparation of N-F-codoped visible light active TiO{sub 2} nanorod arrays is reported. In the process, simultaneous nitrogen and fluorine doped TiO{sub 2} nanorod arrays on the glass substrates were achieved by liquid phase deposition method using ZnO nanorod arrays as templates with different calcination temperature. The as-prepared samples were characterized by Raman spectroscopy, scanning electron microscopy (SEM), transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS) and UV-vis absorption spectra measurements. It was found that calcination temperature is an important factor influencing the microstructure and the amount of N and F in TiO{sub 2} nanorod arrays samples. The visible light photocatalytic properties were investigated using methylene blue (MB) dye as a model system. The results showed that N-F-codoped TiO{sub 2} nanorod arrays sample calcined at 450 {sup o}C demonstrated the best visible light activity in all samples, much higher than that of TiO{sub 2} nanoparticles and P25 particles films.

36 MATERIALS SCIENCE↗

Coherent summation of spatially distorted laser Doppler signals by using a two-dimensional heterodyne detector array

Phase-sensitive coherent summation of individual heterodyne detector array signals was demonstrated for the enhanced detection of spatially distorted laser Doppler returns. With the use of a 2 x 2 heterodyne detector array, the phase and amplitude of a time-varying speckle pattern was detected, and the signal-to-noise ratio of the Doppler shift estimate was shown to be improved by a factor of 2, depending on the extent of spatial coherence loss. These results are shown to agree with a first-order analysis and indicate the advantage of coherent summation for both short-range laser Doppler velocimetry and long-range atmospheric coherent lidar.

Chan, Kin P.↗

Almost perfect in-phase and anti-phase chaotic and periodic phase synchronization in large arrays of diode lasers

In this paper we study phase synchronization in large arrays of weakly coupled single mode semiconductor laser diodes. We show that if the coupling topology is chosen appropriately, the laser array exhibits robust phase synchrony (including chaotic and non-chaotic phase synchrony). Furthermore, one can define coupling topologies that lead to chaotic anti-phase synchronization. To the best of our knowledge, chaotic anti-phase synchronization has not been observed in large arrays of coupled nonlinear oscillators. Additionally, when diodes are coupled via a decayed non-local coupling scheme, the leading spatial mode can be stable. This leads to an almost-perfect phase synchronous state where the phases are synchronized, but the system is not set exactly on the synchronization manifold. This almost-perfect phase synchronous state is robust to noise and frequency disorder and can be realized under periodic (fixed-intensity limit cycle) continuous-wave and chaotic behavior. The presented result is an example of the broader phenomenon of linear transverse mode selection taking place in a coupled oscillator system with nonlinear dynamics.

47 OTHER INSTRUMENTATION↗

Diffraction coupled phase-locked semiconductor laser array

A new monolithic, diffraction coupled phase-locked semiconductor laser array has been fabricated. Stable narrow far-field patterns (approximately 3 deg) and peak power levels of 1 W have been obtained for 100-micron-wide devices with threshold currents as low as 250 mA. Such devices may be useful in applications where high power levels and stable radiation patterns are needed.

Katz, J.↗

Separate-contact phase-locked semiconductor laser arrays

The novel optoelectronic devices discussed, phase-locked semiconductor laser arrays with separate contacts can perform a variety of near field and far field pattern tailoring functions and control mutual coherence among array elements, as well as lasing wavelength selectivity and tunability. Attention is presently given to experimental results from such arrays, which indicate that the threshold currents of the 4-micron wide lasers employed are typically 60 mA. The separate contacts to each one of them are provided by means of two-level metallization.

Katz, J.↗