ICRF Specific Plasma Wall Interactions in JET with the ITER-Like Wall

A variety of plasma wall interactions (PWIs) during operation of the so-called A2 ICRF antennas is observed in JET with the ITER-like wall. Amongst effects of the PWIs, the W content increase is the most significant, especially at low plasma densities. No increase of W source from the main divertor and entrance of the outer divertor during ICRF compared to NBI phases was found by means of spectroscopic and WI (400.9 nm) imaging diagnostics. In contrary, the W flux there is higher during NBI. Charge exchange neutrals of hydrogen isotopes could be excluded as considerable contributors to the W source. The high W content in ICRF heated limiter discharges suggests the possibility of other W sources than the divertor alone. Dependencies of PWIs to individual ICRF antennas during q95-scans, and intensification of those for the 90 phasing, indicate a link between the PWIs and the antenna near-fields. The PWIs include heat loads and Be sputtering pattern on antenna limiters. Indications of some PWIs at the outer divertor entrance are observed which do not result in higher W flux compared to the NBI phases, but are characterized by small antenna-specific (up to 25% with respect to ohmic phases) bipolar variations of WI emission. The first TOPICA calculations show a particularity of the A2 antennas compared to the ITER antenna, due to the presence of long antenna limiters in the RF image current loop and thus high near-fields across the most part of the JET outer wall.

Bobkov, V.↗

Overview of TAE technologies’ HHFW project on LAPD

Simulation survey performed at TAE Technologies, has demonstrated that high harmonic fast wave (HHFW) heating is a promising scenario to heat core electrons of FRC plasma. To prepare the proposed experimental study of HHFW antenna-plasma coupling and wave propagation on LAPD machine at UCLA, a high-power-capable 4-strap antenna has been calculated and designed through collaboration among TAE, ORNL, ASIPP, and UCLA. This antenna was mechanically designed and fabricated by ASIPP and it has been installed recently on LAPD. Meanwhile, by using the Petra-M code, a newly developed generic electromagnetic simulation tool for modeling RF wave propagation, the RF-SciDAC team starts 3D full wave simulations. Detailed information on antenna electromagnetic simulations and mechanical design, as well as preliminary experimental results of wave propagation study with the newly installed phased- array antenna, will be presented in this paper.REFE

Yang, Xiaokang↗

Ion and electron cyclotron wall conditioning in stellarator and tokamak magnetic field configuration on WEGA

Discharge wall conditioning is an effective tool to improve plasma performance in tokamaks and stellarators. RF Discharge Conditioning (RFDC) techniques are envisaged for use during operational campaigns on superconducting devices like the ITER tokamak and W7-X stellarator, as alternative to DC Glow Discharge Conditioning which is inefficient in presence of magnetic fields. This contribution investigates RFDC in both the ion and electron cyclotron range of frequencies (ICRF and ECRF) on the WEGA device (Max-Planck-Institute for Plasma Physics, Greifswald, Germany) as preparation for W7-X operation. ECRF discharges produced by localised absorption of RF power at EC resonance layers suffer from poor radial discharge homogeneity in the tokamak vacuum magnetic field configuration, severely limiting the plasma wetted wall areas and consequently the conditioning efficiency. The non-localised production of ICRF discharges by collisional RF power absorption features much improved discharge homogeneity making Ion Cyclotron Wall Conditioning (ICWC) the favoured RFDC technique for superconducting tokamaks. RFDC with the stellarator vacuum magnetic field needs to aim at sufficient plasma densities at and outside the last closed flux surface (LCFS), maximising the convective plasma flux along the open field lines to the wall. Whereas for ICRF discharges this condition is easily fulfilled, on WEGA for He-ECRF discharges this could be achieved as well by off axis heating close to the LCFS. In stellarator magnetic field configuration it is found that He-ICWC for wall desaturation is at least one order of magnitude more efficient than He-ECWC. Novel ECWC methods are proposed that can decrease this efficiency gap with ICWC to a factor 2-3. The efficiency difference is less pronounced in case of H{sub 2}-ICWC and ECWC for isotopic exchange.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Upgrade of the Fermilab Spoke Test Cryostat for Testing of PIP-II 650 MHz 5-Cell Elliptical Cavities

Design of the high beta 650 MHz prototype cryomodule for PIP-II is currently undergoing at Fermilab. The cryomodule includes six 5-cell elliptical SRF cavities with accelerating voltage up to 20 MV and low heat dissipation (Q₀ > 3·10^{z}EhNZeHn). Characterization of performance of fully integrated jacketed cavities with high power coupler and tuner is crucial for the project. Such a characterization of jacketed cavity requires a horizontal test cryostat. Existing horizontal testing facilities at Fermilab, Horizontal Test Stand (HTS) and Spoke Test Cryostat (STC), are not large enough to accommodate jacketed 650 MHz 5-cell cavity. An upgrade of the STC is proposed to install extension to the cryostat and modify cryogenic connections and RF infrastructure to provide testing of 650 MHz cavities. In this paper we describe STC upgrade and commissioning of the upgraded facility. We discuss mitigation of issues and problems specific for testing of high Q₀ 650 MHz cavities, which require low residual magnetic field and low acoustic and mechanical vibrations environment.

43 PARTICLE ACCELERATORS↗

Fast, high sensitivity dewpoint hygrometer

A dewpoint/frostpoint hygrometer that uses a surface moisture-sensitive sensor as part of an RF oscillator circuit with feedback control of the sensor temperature to maintain equilibrium at the sensor surface between ambient water vapor and condensed water/ice. The invention is preferably implemented using a surface acoustic wave (SAW) device in an RF oscillator circuit configured to generate a condensation-dependent output signal, a temperature sensor to measure the temperature of the SAW device and to distinguish between condensation-dependent and temperature-dependent signals, a temperature regulating device to control the temperature of the SAW device, and a feedback control system configured to keep the condensation-dependent signal nearly constant over time in the presence of time-varying humidity, corrected for temperature. The effect of this response is to heat or cool the surface moisture-sensitive device, which shifts the equilibrium with respect to evaporation and condensation at the surface of the device. The equilibrium temperature under feedback control is a measure of dewpoint or frostpoint.

Hoenk, Michael E.↗

Wide-frequency range, dynamic matching network and power system for the “Shoelace” radio frequency antenna on the Alcator C-Mod tokamak

A wide-frequency range (50–300 kHz) power system has been implemented for use with a new RF antenna – the “Shoelace” antenna – built to drive coherent plasma fluctuations in the edge of the Alcator C-Mod tokamak. A custom, dynamically tunable matching network allows two commercial 1 kW, 50-Ω RF amplifiers to drive the low-impedance, inductive load presented by the antenna. This is accomplished by a discretely variable L-match network, with 81 independently selected steps available for each of the series and parallel legs of the matching configuration. A compact programmable logic device provides a control system that measures the frequency with better than 1 kHz accuracy and transitions to the correct tuning state in less than 1 ms. At least 85% of source power is dissipated in the antenna across the operational frequency range, with a minimum frequency slew rate of 1 MHz/s; the best performance is achieved in the narrower band from 80 to 150 kHz which is of interest in typical experiments. The RF frequency can be run with open-loop control, following a pre-programmed analog waveform, or phase-locked to track a plasma fluctuation diagnostic signal in real time with programmable phase delay; the amplitude control is always open-loop. The control waveforms and phase delay are programmed remotely. These tools have enabled first-of-a-kind measurements of the tokamak edge plasma system response in the frequency range and at the wave number at which coherent fluctuations regulate heat and particle transport through the plasma boundary.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effect of External Magnetic Fields on the Operation of RF Cavities

Recent experiments have shown severe surface damage and a reduction of the maximum accelerating gradient for an rf cavity that is operating under external magnetic fields. This implies that serious problems may occur in lattices where rf cavities and external magnetic fields coexist, such as those of the proposed neutrino factory and muon collider. Although existing data suggest that this magnetic field dependent breakdown is associated with the emission of electrons from locally enhanced field regions on the cavity surface, the mechanism that drives this effect is not yet well understood. Here, we show that such field emitted electrons are accelerated by the cavity and focused by the magnetic field to the other side of the cavity where they heat its surface. We show that if the magnetic field is strong, significant surface deformation can occur that eventually could limit the accelerating gradient of the cavity. Results of our model are compared to the existing experimental data from an 805 MHz cavity. The geometry of the pillbox cavity in our case is more complicated, and the analysis depends on the electron energies, focused dimensions, and angle of impact, but damage may reasonably be expected with similar cyclical heating above 40 C. However, it is not yet known what the mechanism is for such surface damage to cause a cavity to breakdown. One possibility is that if electrons are focused on a location with a high surface gradient, then the local damage will generate new asperities with higher FN enhancement factors, thus initiating breakdown. While our preliminary analysis offers some quantification on the effects of the magnetic fields on the cavity's operation, other theoretical issues were not addressed. For instance, emission from secondary electrons was disregarded, the asperity was placed on axis, the magnetic field was assumed as uniform, the thermal-diffusion calculation ignored the shape of the rise time, and adopted an approximate calculation. On the theoretical level, it will be interesting to pursue additional simulations exploring these effects in detail. Experimentally, there is a clear need for more well-designed experiments to study, systematically, the effect of external fields on the cavity's operation.

43 PARTICLE ACCELERATORS↗

DESIGN AND PRELIMINARY TEST OF THE 1500 MHZ NSLS-II PASSIVE SUPERCONDUCTING RF CAVITY

NSLS-II is a new ultra-bright 3 GeV 3rd generation synchrotron radiation light source. The performance goals require operation with a beam current of 500mA and a bunch current of at least 0.5mA. Ion clearing gaps are required to suppress ion effects on the beam. The natural bunch length of 3mm is planned to be lengthened by means of a third harmonic cavity in order to increase the Touschek limited lifetime. Earlier work described the design alternatives and the geometry selected for a copper prototype. We subsequently have iterated the design to lower the R/Q of the cavity and to increase the diameter of the beam pipe ferrite HOM dampers to reduce the wakefield heating. A niobium cavity and full cryomodule including LN2 shield, magnetic shield and insulating vacuum vessel have been fabricated and installed. A passive SRF 3rd harmonic cavity consisting of two tightly coupled cells has been designed and fabricated for NSLS-II. Initial cold tests of this cavity are very promising. These tests have verified that the cavity frequency and mode separation between the 0 and {pi}-modes can be set at manufacture. Further, the frequency separation can be maintained over wide tuning ranges necessary for operation. Future work includes HOM damper and motorized tuner development.

3 GeV 3rd generation synchrotron↗

Study of Conduction-Cooled Superconducting Quadrupole Magnets Combined with Dipole Correctors for the ILC Main Linac

A superconducting rf (SRF) cryomodule for International Linear Collider(ILC) Main Linac equips focus/steering magnets. The magnets are "superferric" magnets with four superconducting (SC) race track coils conductively cooled from the cryomodule LHe supply pipe. The quadrupole field gradient and dipole field are 40 T/m and 0.1 T, respectively. The magnet length and iron-pole radius are 1 m and 0.045 m, respectively. It is known that dark current is generated at SRF cavities and accelerated through the following linac string. The dark current reaches and heats the SC magnets. It is estimated that the power deposition in the magnet may reach more than a few watts and temperature of the SC coils may locally reach to critical temperature of NbTi. It is important to make the magnet not reach quench with sufficient conduction cooling. We aim to realize the SC magnet which can stably operate under such condition. We plan to develop test coils made of three types of SC materials, NbTi, Nb₃Sn, and MgB₂ and study thermal characteristics and stability . We will develop a short model magnet, based on the test coil results. Here, we will present the magnet design study and the R&D plan.

43 PARTICLE ACCELERATORS↗

Solid-State Ultra-High Power Amplifier Modules Based on 100 V RF GaN Technology for LINACS Operating at 325 and 650 MHz

Purpose / objectives. This research project explores the groundwork for developing a new high efficiency, high reliability and cost effective radio frequency technology to be used in power sources for future linear accelerators. The frequencies of operation are 650 and 325 MHz, in use at Fermi National Laboratory. The technology can be extended to other frequencies. Brief Description. In this research work ultra-high power solid-state radio frequency sources are proposed operating at the stated frequencies of interest. The approach employs high voltage Gallium Nitride radio frequency transistors, operating at 100 V or higher, to achieve 5-kilowatts continuous-wave and 10 kilowatts pulse power level in a small form factor. The 5 kilowatts building block reduces the required number of combiners and related losses to achieve megawatts power levels. The design employs harmonic tuning techniques as used in class E, F and inverse F power amplifiers to achieve >70% efficiency and assembly techniques that overcome heat dissipation in such high power density systems. Solid-state technology achieves million hour operating lifetime compared to 10 – 100 thousand hours for incumbent technology based on vacuum tubes. Additionally, the modular approach afforded by a solid-state solution avoids complete system shutdown when one module fails. Overall, the approach reduces capital and operating cost. Research Results. During Phase I radio frequency Gallium Nitride building block transistors with 50 mm gate periphery were designed and built which achieve ~600 W continuous-wave when operating at 100 V bias and 1-kW pulsed when operating at 150V. This level of performance has been demonstrated with operation at 325 and 650 MHz, and in both cases measured efficiency exceeded 70%. Potential Applications. The technology identified as suitable for high efficiency power sources in particle accelerators can also be applied in megawatt class radars and several industrial, scientific and medical applications such as microwave sintering, radio frequency and microwave ablation, oil percolation, MRI scanners and Nuclear Magnetic Resonance spectrometers, etc… The high efficiency of these devices also translates into reduced electrical power consumption and lower cost of operation.

100 VDC↗

Superconducting DC and RF properties of ingot Niobium used in SRF cavity fabrication

Bulk niobium (Nb) has been the material of choice for the superconducting radiofrequency (SRF) cavity used in particle accelerator because of its highest transition temperature (Tc) and highest lower critical field (Hc1~ 190 mT) among the elemental type-II superconductors. The overall performance of these SRF cavities is measured by its quality factor, Q0 as a function of the accelerating gradient, Eacc. Higher Q0 for the reduction of cryogenic loss and higher Eacc for the use of high energy accelerators are desired. SRF cavities fabricated from ingot niobium have become a viable alternative to standard high-purity fine-grain Nb for the fabrication of high-performing SRF cavities with the possibility of significant cost reduction. In this contribution, we present the results on DC, low-frequency and RF measurements of Nb rods machined from ingots with different impurity concentrations, provided by CBMM, Brazil. The rods have been subjected to different treatments typically applied to SRF cavities. In addition, single-cell cavities are being fabricated from the same ingot material and initial results on one of them showed high Q0-values at 2 K up to peak surface magnetic fields of about 110 mT. Residual resistance values below 5 n have been consistently achieved on this cavity. A new induction furnace was commissioned for the heat treatment of these single-cells, which allows avoiding subsequent chemical etching of the cavity surface.

Myneni, Ganapati↗

ICRF-enhanced plasma potentials in the SOL of Alcator C-Mod

We performed an extensive survey of the plasma potential in the scrape-off layer (SOL) of Ion Cyclotron Range-of Frequencies (ICRF)-heated discharges on Alcator C-Mod. Our results show that plasma potentials are enhanced in the presence of ICRF power and plasma potential values of >100 V are often observed. Such potentials are high enough to induce sputtering of high-Z molybdenum (Mo) plasma facing components by deuterium ions on C-Mod. For comparison, the plasma potential in Ohmic discharges is typically less than 10 V, well below the threshold needed to induce Mo sputtering by deuterium ions. ICRF-enhanced plasma potentials are observed in the SOL regions that both magnetically map and do not map to active ICRF antennas. Regions that magnetically map to active ICRF antennas are accessible to slow waves directly launched by the antennas and these regions experience plasma potential enhancement that is partially consistent with the slow wave rectification mechanism. One of the most defining features of the slow wave rectification is a threshold appearance of significant plasma potentials (>100 V) when the dimensionless rectification parameter Λ{sub −o} is above unity and this trend is observed experimentally. We also observe ICRF-enhanced plasma potentials >100 V in regions that do not magnetically map to the active antennas and, hence, are not accessible for slow waves launched directly by the active antennas. However, unabsorbed fast waves can reach these regions. The general trend that we observe in these 'un-mapped' regions is that the plasma potential scales with the strength of the local RF wave fields with the fast wave polarization and the highest plasma potentials are observed in discharges with the highest levels of unabsorbed ICRF power. Similarly, we find that core Mo levels scale with the level of unabsorbed ICRF power suggesting a link between plasma potentials in the SOL and the strength of the impurity source.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design workflow of a symmetric traveling wave antenna for fast ion production on DD tokamaks

Initial computational plasma physics scoping and a finite element method antenna modeling design workflow for a symmetric center-fed high-field side high harmonic fast wave traveling wave array (TWA) antenna are reported here. The TWA is designed to generate a test population of fast deuterium ions in an existing D–D tokamak by heating neutral beam deuterium ions, accelerating them from 80 keV to several hundred keV. The resulting fast particles are tailored to mimic key reactor energetic particle parameters with regards to exciting Alfven eigenmode instabilities, allowing for a D–D tokamak like DIII-D or ASDEX-U to replicate reactor-relevant conditions experimentally. Initial scenario scoping for high single-pass absorption as well as good preferential fast ion damping relative to electron damping was completed using the ray-tracing/Fokker–Planck codes GENRAY and CQL3D. Python RF network analysis packages were used to create a custom TWA optimization tool to inform a COMSOL flat antenna design, and Petra-M was used to study cold plasma effects. The TWA produced by this workflow has several novel features when compared to previous TWA studies, including symmetric center feeding, and passive end straps for image current cancellation for reduced impurity production. We show here that the antenna design workflow can readily produce TWA antennas optimized for reflection coefficient, image current cancellation, and launched power spectrum shape; and that a population of fast ions can be generated in the correct region of parameter space, warranting future more detailed studies.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Paramagnetic Attraction of Impurity-Helium Solids

Impurity-helium solids are formed when a mixture of impurity and helium gases enters a volume of superfluid helium. Typical choices of impurity gas are hydrogen deuteride, deuterium, nitrogen, neon and argon, or a mixture of these. These solids consist of individual impurity atoms and molecules as well as clusters of impurity atoms and molecules covered with layers of solidified helium. The clusters have an imperfect crystalline structure and diameters ranging up to 90 angstroms, depending somewhat on the choice of impurity. Immediately following formation the clusters aggregate into loosely connected porous solids that are submerged in and completely permeated by the liquid helium. Im-He solids are extremely effective at stabilizing high concentrations of free radicals, which can be introduced by applying a high power RF dis- charge to the impurity gas mixture just before it strikes the super fluid helium. Average concentrations of 10(exp 19) nitrogen atoms/cc and 5 x 10(exp 18) deuterium atoms/cc can be achieved this way. It shows a typical sample formed from a mixture of atomic and molecular hydrogen and deuterium. It shows typical sample formed from atomic and molecular nitrogen. Much of the stability of Im-He solids is attributed to their very large surface area to volume ratio and their permeation by super fluid helium. Heat resulting from a chance meeting and recombination of free radicals is quickly dissipated by the super fluid helium instead of thermally promoting the diffusion of other nearby free radicals.

Bernard, E. P.↗

NASA Tech Briefs, May 2013

Topics include: Test Waveform Applications for JPL STRS Operating Environment; Pneumatic Proboscis Heat-Flow Probe; Method to Measure Total Noise Temperature of a Wireless Receiver During Operation; Cursor Control Device Test Battery; Functional Near-Infrared Spectroscopy Signals Measure Neuronal Activity in the Cortex; ESD Test Apparatus for Soldering Irons; FPGA-Based X-Ray Detection and Measurement for an X-Ray Polarimeter; Sequential Probability Ratio Test for Spacecraft Collision Avoidance Maneuver Decisions; Silicon/Carbon Nanotube Photocathode for Splitting Water; Advanced Materials and Fabrication Techniques for the Orion Attitude Control Motor; Flight Hardware Packaging Design for Stringent EMC Radiated Emission Requirements; RF Reference Switch for Spaceflight Radiometer Calibration; An Offload NIC for NASA, NLR, and Grid Computing; Multi-Scale CNT-Based Reinforcing Polymer Matrix Composites for Lightweight Structures; Ceramic Adhesive and Methods for On-Orbit Repair of Re-Entry Vehicles; Self-Healing Nanocomposites for Reusable Composite Cryotanks; Pt-Ni and Pt-Co Catalyst Synthesis Route for Fuel Cell Applications; Aerogel-Based Multilayer Insulation with Micrometeoroid Protection; Manufacturing of Nanocomposite Carbon Fibers and Composite Cylinders; Optimized Radiator Geometries for Hot Lunar Thermal Environments; A Mission Concept: Re-Entry Hopper-Aero-Space-Craft System on-Mars (REARM-Mars); New Class of Flow Batteries for Terrestrial and Aerospace Energy Storage Applications; Reliability of CCGA 1152 and CCGA 1272 Interconnect Packages for Extreme Thermal Environments; Using a Blender to Assess the Microbial Density of Encapsulated Organisms; Mixed Integer Programming and Heuristic Scheduling for Space Communication; Video Altimeter and Obstruction Detector for an Aircraft; Control Software for Piezo Stepping Actuators; Galactic Cosmic Ray Event-Based Risk Model (GERM) Code; Sasquatch Footprint Tool; and Multi-User Space Link Extension (SLE) System.

Source record↗

Preparation and Characterization of YBa 2 Cu 4 O 8 Superconductor

Solid-state reaction of appropriate amounts of Y 2 O 3 , BaCOs, and CuO for 2 h at 800°C in flowing oxygen with a total pressure of 2.7 x 10 2 Pa (2 mm Hg), followed by cooling and annealing at 750°C for 10 h in oxygen at ambient pressure, has produced orthorhombic YBa 2 Cu 4 O 8 (124) as the main phase with YBa 2 Cu 3 O x (123) as an impurity phase. After the as-calcined powder was annealed in oxygen at 800°C for 24 h under ambient pressure, the phase purity improved considerably. Calcined 124 powder was pressed into pellets and rapidly annealed at temperatures from 870°C to 935°C. At these temperatures, the 124 decomposed into 123. The superconducting transition temperature, T c , of the annealed samples depended upon the annealing temperature and atmosphere. The decomposed samples have been characterized by low field RF SQUID magnetometer and high resolution transmission electron microscopy.

36 MATERIALS SCIENCE↗

Simulations of ICRF Heating for SPARC during First Campaign and Primary Reference-Like Discharge using the Stix Code

High magnetic field tokamaks, like SPARC, rely on ion cyclotron radio frequency heating (ICRF) to reach fusion relevant temperatures. The SPARC tokamak will have 14 ICRF antennas in 7 toroidal locations delivering > 20 MW of power to the plasma. New capabilities with the full wave cold plasma solver, Stix, now allow for resolving the wave-particle resonances using lower order thermal corrections to capture core absorption of Landau damping and ion resonances in devices like SPARC. Favorable comparisons to the TORIC codes give confidence in the single pass absorption of this model to accurately capture the strength of edge interactions of the RF. Using this new dielectric formulation in the Stix code, simulations of the 2D poloidal cross section of SPARC are completed for the first campaign and primary reference-like discharges (PRD-like). A scan of the minority ion concentrations of helium-3 is performed and shows the expected behavior that as the helium-3 decreases the amount of single pass absorption also decreases which is seen in both scenarios. Additionally, both scenarios show only slight differences in single-pass absorption for the range of 3% to 5% helium-3 allowing for more flexibility in experiments. This study also highlights the differences between the first campaign and PRD-like with the first campaign discharges showing much more multi-pass absorption and an effect of confining the wave to a smaller portion of the cross-section due to the fast wave cut-off. This latter result suggests that far-field sheath rectification at the high-field side would be minimal for the first campaign scenario.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High Harmonic Fast Wave experiments on TST-2 and UTST

HHFW experiments on TST-2 and UTST were performed. In the TST-2 HHFW experiment, the pickup probe mounted on the inboard wall detected the same PDI lower sideband peak as probes on the outboard side. Since the frequency difference from the pump wave corresponds to the ion cyclotron frequency on the low field side, the lower sideband wave is believed to be generated at the plasma edge on the low field side, and propagated to the high field side. This component may be the FW. In the UTST HHFW experiment, direct measurements of the RF fields in the plasma were made successfully.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗