SU-E-T-362: Enhanced Dynamic Wedge Output Factors for Varian 2300CD and the Case for a Reference Database

Purpose: Dose inhomogeneity in treatment planning can be compensated using physical wedges. Enhanced dynamic wedges (EDW) were introduced by Varian to overcome some of the short comings of physical wedges. The objectives of this study were to measure EDW output factors for 6 MV and 20 MV photon energies for a Varian 2300CD. Secondly to review the literature in terms of published enhanced dynamic wedge output factors (EDWOF) for different Varian models and thereby adding credence to the case of the validity of reference databases. Methods: The enhanced dynamic wedge output factors were measured for the Varian 2300CD for both 6 MV and 20 MV photon energies. Twelve papers with published EDWOF for different Varian Linac models were found in the literature. Results: The EDWOF for 6 MV varied from 0.980 for a 5×5 cm 10 degree wedge to 0.424 for 20×20 cm 60 degree wedge. Similarly for 20 MV, the EDWOF varied from 0.986 for 5×5 cm 10 degree wedge to 0.529 for 20×20 cm 60 degree wedge. EDWOF are highly dependent on field size. Comparing our results with the published mean, we found an excellent agreement for 6 MV EDWOF with the percentage differences ranging from 0.01% to 0.57% with a mean of 0.03%. The coefficient of variation of published EDWOF ranged from 0.17% to 0.85% and 0.1% to 0.9% for the for 6 MV and 18MV photon energies respectively. This paper provides the first published EDWOF for 20 MV photon energy. In addition, we have provided the first compendium of EDWOFs for different Varian linac models. Conclusion: The consistency of EDWOF across models and institution provide further support that, a standard data set of basic photon and electron dosimetry could be established, as a guide for future commissioning, beam modeling and quality assurance purposes.

60 APPLIED LIFE SCIENCES↗

SU-F-207-14: Low Contrast Detectability (LCD) at Different Diagnostic Reference Levels for Adult Abdominal CT Procedures

Purpose Using diagnostic reference levels (DRL) to optimize CT protocols has potential to reduce radiation dose and meet regulatory requirements. However, DRL’s tend to be misconstrued as dose limits, are typically designed for specific patient populations, and are assumed to have acceptable image quality (AIQ) associated with them. To determine the image quality that is associated with established DRL’s for adult abdominal CT studies, a LCD phantom study was employed. Methods: A CT phantom (CIRS) containing three columns of 7 spherical targets, ranging from 10mm to 2.4 mm, that are 5, 10, and 20 HU below the background (HUBB) matrix was scanned with a GE HD750 64 slice scanner. The phantom was scanned at the NEXT 2006 25th CTDIvol of 12 mGy, the NCRP 172 achievable dose (AD) CTDIvol of 17 mGy and 75th CTDIvol of 25 mGy and at the ACR recommended CTDIvol of 25 mGy. It was also scanned at a CTDIvol 20% greater than the AD at 20 mGy and the ACR maximum threshold of 30 mGy. Results: At the NEXT 2006 25th percentile CTDIvol of 12 mGy, a 6.3 mm low contrast lesion was detectable in the 20 HUBB; 6.3 mm in the 10 HUBB and 10 mm in the 5 HUBB column. Increasing the CTDIvol to the NCRP 172 AD of 17 mGy, an additional 4.8 mm lesion was visualized in the 20 HUBB column. At 20 mGy, an additional 4.8 mm lesion was detectable in the 10 HUBB column. No further lesions were visible between 20 and 30 mGy. However, conspicuity of all lesions increased with each additional step up in CTDI. Conclusion: Optimizing radiation dose to achieve AIQ is a critical aspect of any dose optimization committee. Hence, judicious monitoring of radiation exposure to patients has to be balanced with diagnostic image quality.

60 APPLIED LIFE SCIENCES↗

Reference respiratory waveforms by minimum jerk model analysis

Purpose: CyberKnife{sup ®} robotic surgery system has the ability to deliver radiation to a tumor subject to respiratory movements using Synchrony{sup ®} mode with less than 2 mm tracking accuracy. However, rapid and rough motion tracking causes mechanical tracking errors and puts mechanical stress on the robotic joint, leading to unexpected radiation delivery errors. During clinical treatment, patient respiratory motions are much more complicated, suggesting the need for patient-specific modeling of respiratory motion. The purpose of this study was to propose a novel method that provides a reference respiratory wave to enable smooth tracking for each patient. Methods: The minimum jerk model, which mathematically derives smoothness by means of jerk, or the third derivative of position and the derivative of acceleration with respect to time that is proportional to the time rate of force changed was introduced to model a patient-specific respiratory motion wave to provide smooth motion tracking using CyberKnife{sup ®}. To verify that patient-specific minimum jerk respiratory waves were being tracked smoothly by Synchrony{sup ®} mode, a tracking laser projection from CyberKnife{sup ®} was optically analyzed every 0.1 s using a webcam and a calibrated grid on a motion phantom whose motion was in accordance with three pattern waves (cosine, typical free-breathing, and minimum jerk theoretical wave models) for the clinically relevant superior–inferior directions from six volunteers assessed on the same node of the same isocentric plan. Results: Tracking discrepancy from the center of the grid to the beam projection was evaluated. The minimum jerk theoretical wave reduced the maximum-peak amplitude of radial tracking discrepancy compared with that of the waveforms modeled by cosine and typical free-breathing model by 22% and 35%, respectively, and provided smooth tracking for radial direction. Motion tracking constancy as indicated by radial tracking discrepancy affected by respiratory phase was improved in the minimum jerk theoretical model by 7.0% and 13% compared with that of the waveforms modeled by cosine and free-breathing model, respectively. Conclusions: The minimum jerk theoretical respiratory wave can achieve smooth tracking by CyberKnife{sup ®} and may provide patient-specific respiratory modeling, which may be useful for respiratory training and coaching, as well as quality assurance of the mechanical CyberKnife{sup ®} robotic trajectory.

60 APPLIED LIFE SCIENCES↗

Correcting scan-to-scan response variability for a radiochromic film-based reference dosimetry system

Purpose: In radiochromic film dosimetry systems, measurements are usually obtained from film images acquired on a CCD-based flatbed scanner. The authors investigated factors affecting scan-to-scan response variability leading to increased dose measurement uncertainty. Methods: The authors used flatbed document scanners to repetitively scan EBT3 radiochromic films exposed to doses 0–1000 cGy, together with three neutral density filters and three blue optical filters. Scanning was performed under two conditions: scanner lid closed and scanner lid opened/closed between scans. The authors also placed a scanner in a cold room at 9 °C and later in a room at 22 °C and scanned EBT3 films to explore temperature effects. Finally, the authors investigated the effect of altering the distance between the film and the scanner’s light source. Results: Using a measurement protocol to isolate the contribution of the CCD and electronic circuitry of the scanners, the authors found that the standard deviation of response measurements for the EBT3 film model was about 0.17% for one scanner and 0.09% for the second. When the lid of the first scanner was opened and closed between scans, the average scan-to-scan difference of responses increased from 0.12% to 0.27%. Increasing the sample temperature during scanning changed the RGB response values by about −0.17, −0.14, and −0.05%/°C, respectively. Reducing the film-to-light source distance increased the RBG response values about 1.1, 1.3, and 1.4%/mm, respectively. The authors observed that films and film samples were often not flat with some areas up to 8 mm away from the scanner’s glass window. Conclusions: In the absence of measures to deal with the response irregularities, each factor the authors investigated could lead to dose uncertainty >2%. Those factors related to the film-to-light source distance could be particularly impactful since the authors observed many instances where the curl of film samples had the potential to cause dose uncertainty in excess of 5%. Two expedients will eliminate the uncertainties: a transparent sheet (preferably glass) placed over the scanned film keeps the film-to-light source distance constant, and an EBT3 reference film included in all scans provides correction factors for measured response values.

60 APPLIED LIFE SCIENCES↗

SU-F-J-180: A Reference Data Set for Testing Two Dimension Registration Algorithms

Purpose: To create and characterize a reference data set for testing image registration algorithms that transform portal image (PI) to digitally reconstructed radiograph (DRR). Methods: Anterior-posterior (AP) and Lateral (LAT) projection and DRR image pairs from nine cases representing four different anatomical sites (head and neck, thoracic, abdominal, and pelvis) were selected for this study. Five experts will perform manual registration by placing landmarks points (LMPs) on the DRR and finding their corresponding points on the PI using computer assisted manual point selection tool (CAMPST), a custom-made MATLAB software tool developed in house. The landmark selection process will be repeated on both the PI and the DRR in order to characterize inter- and -intra observer variations associated with the point selection process. Inter and an intra observer variation in LMPs was done using Bland-Altman (B&A) analysis and one-way analysis of variance. We set our limit such that the absolute value of the mean difference between the readings should not exceed 3mm. Later on in this project we will test different two dimension (2D) image registration algorithms and quantify the uncertainty associated with their registration. Results: Using one-way analysis of variance (ANOVA) there was no variations within the readers. When Bland-Altman analysis was used the variation within the readers was acceptable. The variation was higher in the PI compared to the DRR.ConclusionThe variation seen for the PI is because although the PI has a much better spatial resolution the poor resolution on the DRR makes it difficult to locate the actual corresponding anatomical feature on the PI. We hope this becomes more evident when all the readers complete the point selection. The reason for quantifying inter- and -intra observer variation tells us to what degree of accuracy a manual registration can be done. Research supported by William Beaumont Hospital Research Start Up Fund.

60 APPLIED LIFE SCIENCES↗

SU-F-T-64: An Alternative Approach to Determining the Reference Air-Kerma Rate from Extrapolation Chamber Measurements

Purpose: Since 2008 the Physikalisch-Technische Bundesanstalt (PTB) has been offering the calibration of {sup 125}I-brachytherapy sources in terms of the reference air-kerma rate (RAKR). The primary standard is a large air-filled parallel-plate extrapolation chamber. The measurement principle is based on the fact that the air-kerma rate is proportional to the increment of ionization per increment of chamber volume at chamber depths greater than the range of secondary electrons originating from the electrode x{sub 0}. Methods: Two methods for deriving the RAKR from the measured ionization charges are: (1) to determine the RAKR from the slope of the linear fit to the so-called ’extrapolation curve’, the measured ionization charges Q vs. plate separations x or (2) to differentiate Q(x) and to derive the RAKR by a linear extrapolation towards zero plate separation. For both methods, correcting the measured data for all known influencing effects before the evaluation method is applied is a precondition. However, the discrepancy of their results is larger than the uncertainty given for the determination of the RAKR with both methods. Results: A new approach to derive the RAKR from the measurements is investigated as an alternative. The method was developed from the ground up, based on radiation transport theory. A conversion factor C(x{sub 1}, x{sub 2}) is applied to the difference of charges measured at the two plate separations x{sub 1} and x{sub 2}. This factor is composed of quotients of three air-kerma values calculated for different plate separations in the chamber: the air kerma Ka(0) for plate separation zero, and the mean air kermas at the plate separations x{sub 1} and x{sub 2}, respectively. The RAKR determined with method (1) yields 4.877 µGy/h, and with method (2) 4.596 µGy/h. The application of the alternative approach results in 4.810 µGy/h. Conclusion: The alternative method shall be established in the future.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-F-T-276: Source Modeling and VMAT Quality Assurance Referring to the TrueBeam Representative Beam Data for Eclipse

Purpose: To study quality assurance (QA) of volumetric modulated arc therapy (VMAT) after the 6MV and 10MV photon beam source modeling, referring to the Varian TrueBeam representative beam data for Eclipse. Methods: The source model needs specific measured beam data, such as PDDs and profiles, diagonal profile, output factors (OFs), and MLC transmission factor (TF) and dosimetric leaf gap (DLG), et al. We downloaded the representative data from myVarian website, which includes TrueBeam 4MV-15MV photon beam data and 6MeV-22MeV electron beam data in w2CAD file format for use with Eclipse and in Excel spreadsheet format for use in data comparison. The beam data in W2CAD format can be imported into the Eclipse system and calibrated for use, as appropriate. We used PTW MP3 water tank to measure the beam data in some typical field sizes, and compared the measured data with the representative data. We found that the PDDs, profiles and OFs are similar. However according to some papers and our measurements, we decided that our MLC TF and DLG are 1.58 and 1.33 (6MV), 1.79 and 1.57 (10MV), respectively. After we had configured the anisotropic analytical algorithm (AAA) with the representative data in Eclipse, we also have done dosimetric verification for 88 VMAT plans. Results: The end-to-end test procedures of VMAT were performed for 6MV and 10MV energy modes. The NE Farmer ion chamber mean measurements showed 1.2% (6MV, 38 cases) and 1.2% (10MV, 50 cases) between measurement and calculation; the Sun Nuclear ArcCheck mean measurements demonstrated gamma pass rates are as followings: 98.9%, 93.2%, 61.0% for 6MV, and 98.9%, 91.9%, 59.5% for 10MV, using 3%/3mm, 2%/2mm, 1%/1mm, 10% threshold criteria, respectively. Conclusion: The representative data is applicable to our TrueBeam for the VMAT plan, though our MLC factors are a little different, and its patientspecific QA is good.

60 APPLIED LIFE SCIENCES↗

MO-FG-CAMPUS-IeP1-03: Establishment of Provincial Diagnostic Reference Levels in Pediatric Imaging

Purpose: To establish provincial diagnostic reference levels (DRLs) in pediatric general radiography and computed tomography (CT) as a tool for the optimization of exposure parameters. Methods: Patient dose survey was conducted in the only pediatric hospital in the province of Nova Scotia. The DRLs were established as the 75th percentile of patient dose distributions in different age groups. For routine radiography projections the DRLs were determined in terms of entrance surface dose (ESD) calculated from the radiation output measurements and the tube current-exposure time product (mAs) recorded for each examination. Patient thickness was measured by the technologist during the examination. The CR and DR systems, employing respectively a fixed technique and phototiming, were evaluated separately; a two-tailed Student’s t-test was used to determine the significance of differences between the means of dose distributions. The CT studies included routine head, chest, abdomen/pelvis, and chest/abdomen/pelvis. The volume CT dose index (CTDIvol) and dose-length product (DLP) values were extracted retrospectively from PACS. The correction factors based on the effective diameter of the patient were applied to the CT dosimetry metrics based on the standard phantoms. Results: The provincial DRLs were established in the following age groups: newborn, 1, 5, 10, and 15 year olds. In general radiography the DR systems demonstrated slightly lower dose than the CR for all views, however the differences were not statistically significant (p > 0.05) for all examinations. In CT the provincial DRLs were lower than the published data, except for head DLPs in all age categories. This might be due to the small patient sample size in the survey. Future work will include additional CT data collection over an extended period of time. Conclusion: Provincial DRLs were established in the dedicated children’s hospital to provide guidance for the other facilities in examinations of pediatric patients.

60 APPLIED LIFE SCIENCES↗

TH-AB-201-06: Examining the Influence of Humidity On Reference Ion Chamber Performance

Purpose: International dosimetry protocols require measurements made with a vented ionization chamber to be corrected for the influence of air density by using the standard temperature-pressure correction factor. The effect of humidity, on the other hand, is generally ignored with the provision that the relative humidity is between certain limits (15% to 80%). However, there is little experimental data in the published literature as to the true effect of humidity on modern reference-class ion chambers. This investigation used two different radiation beams – a Co-60 irradiator and a Sr-90 check source – to examine the effect of humidity on several versions of the standard Farmer-type ion chamber. Methods: An environmental cabinet controlled the humidity. For the Co-60 beam, the irradiation was external, whereas for the Sr-90 measurements, the source itself was placed within the cabinet. Extensive measurements were carried out to ensure that the experimental setup provided reproducible readings. Four chamber types were investigated: IBA FC65-G (×2), IBA FC65-P, PTW30013 & Exradin A19. The different wall materials provided potentially different mechanical responses (i.e., in terms of expansion/contraction) to the water content in the air. The relative humidity was varied between 8 % and 97 % and measurements were made with increasing and decreasing humidity to investigate possible hysteresis effects. Results: Measurements in Co-60 were consistent with the published data obtained with primary standard cavity chambers in ICRU Report 31. Ionization currents with Sr-90 showed no dependence with the relative humidity, within the measurement uncertainties. Very good repeatability of the ionization current was obtained over successive wet/dry cycles, no hysteresis was observed, and there was no dependence on chamber type. Conclusion: This null result is very encouraging as it indicates that humidity has no significant effect on these particular types of ionization chambers, consistent with recommendations in current megavoltage dosimetry protocols.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Colourful Interactions: Highlights 07: Canadian Computed Tomography Survey: National Diagnostic Reference Levels

Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data from 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.

60 APPLIED LIFE SCIENCES↗

Poster - 19: Investigation of Electron Reference Dosimetry Based on Optimal Chamber Shift

An addendum/revision to AAPM TG-51 electron reference dosimetry is highly expected to meet the clinical requirement with the increasing usage of new ion chambers not covered in TG-51. A recent study, Med. Phys. 41, 111701, proposed a new fitting equation for the beam quality conversion factor k’{sub Q} to a wide spectrum of chambers. In the study, an optimal Effective Point of Measurement (EPOM) from Monte Carlo calculations was recommended and the fitting parameters to k’{sub Q} was based on it. We investigated the absolute dose obtained based on the optimal EPOM method and the original TG-51 method with k’{sub R50} determined differently. The results showed that using the Markus curve is a better choice than the well-guarded chamber fitting for an IBA PPC-05 parallel plate chamber if we need to strictly follow the AAPM TG-51 protocol. We also examined the usage of the new fitting equation with measurement performed at the physical EPOM, instead of the optimal EPOM. The former is more readily determined and more practical in clinics. Our study indicated that the k’{sub Q} fitting based on the optimal EPOM can be used to measurement at the physical EPOM with no significant clinical impact. The inclusion of Farmer chamber gradient correction P{sub gr} in k’{sub Q}, as in the mentioned study, asks for the precise positioning of chamber center at dref. It is not recommended in clinics to avoid over-correction for low electron energies, especially for an institute having matching Linacs implemented.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used in this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.

60 APPLIED LIFE SCIENCES↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 12: Suitability of plan class specific reference fields for estimating dosimeter correction factors for small clinical CyberKnife fields

Purpose: The purpose of this work is to investigate the utility of plan class specific reference (PCSR) fields for predicting dosimeter response within isocentric and non-isocentric composite clinical fields using the smallest fields employed by the CyberKnife radiosurgery system. Methods: Monte Carlo dosimeter response correction factors (CFs) were calculated for a plastic scintillator and microchamber dosimeter in 21 clinical fields and 9 candidate plan-class PCSR fields which employ the 5, 7.5 and 10 mm diameter collimators. Measurements were performed in 5 PCSR fields to confirm the predicted relative response of detectors in the same field. Results: Ratios of corrected measured dose in the PCSR fields agree to within 1% of unity. Calculated CFs for isocentric fields agree within 1.5% of those for PCSR fields. Large and variable microchamber CFs are required for non-isocentric fields, with differences as high as 5% between different clinical fields in the same plan class and 4% within the same field depending on the point of measurement. Non-isocentric PCSR fields constructed to have relatively homogenous dose over a region larger than the detector have very different ion chamber CFs from clinical fields. The plastic scintillator detector has much more consistent response within each plan class but still require 3–4% corrections in some fields. Conclusions: While the PCSR field concept is useful for small isocentric fields, this approach may not be appropriate for non-isocentric clinical fields which exhibit large and variable ion chamber CFs which differ significantly from CFs for homogenous field PCSRs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Complete Genome Assembly of Reference Strain Ochrobactrum anthropi ATCC 49687

Ochrobactrum anthropi is an occasional cause of nosocomial infections; however, interest in the organism lies in its phylogenetic proximity to the genus Brucella. Here, we present the 4.9-Mb finished genome of Ochrobactrum anthropi ATCC 49687, most commonly used as an exclusionary reference organism.

59 BASIC BIOLOGICAL SCIENCES↗

Complete Genome Assembly of Enterococcus faecalis 29212, a Laboratory Reference Strain

Enterococcus faecalis is a nonmotile Gram-positive coccus, found both as a commensal organism in healthy humans and animals and as a causative agent of multiple diseases, in particular endocarditis. We sequenced the genome of E. faecalis ATCC 29212, a commonly used reference strain in laboratory studies, to complete “finished” annotated assembly (3 Mb).

59 BASIC BIOLOGICAL SCIENCES↗

Elementary reference for the analysis of high-energy nuclear collisions

In this contribution we shall discuss some aspects of the role of elementary reference data for the interpretation of the results from nuclear collisions and show in particular that neutron-proton interactions play a significant role. Furthermore we point out that a complete set of elementary data is desirable, because most theoretical concepts for the interpretation of nuclear collisions rely on such data as input for their calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling of reference operating scenario of GOL-NB multiple-mirror trap

Currently, the GOL-NB multiple-mirror trap is being developed at the Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences. The main scientific goal pursued by building GOL-NB is direct demonstration of suppression of longitudinal losses of particles and energy from the trap by using sections with a multiple-mirror magnetic field, which can be attached to the central gas-dynamic trap. Plasma heating in GOL-NB will be accomplished by neutral beam injection with a power of up to 1.5MW. The paper presents the first results of modeling the dynamics of the plasma parameters and fast ions under the reference operating scenario of the trap in which traditional short magnetic mirrors, rather than multiple-mirror sections, are attached to the central trap. In such a configuration, the plasma lifetime in the trap is expected to be minimal. The modeling was performed by using the DOL kinetic code. As a result, the initial conditions of the experiments are refined and the requirements to the system of maintaining the particle balance in the trap are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗