Search NASA⌕ Search

SEARCH · Search NASA

Results for “References”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Sci-Thur PM – Colourful Interactions: Highlights 07: Canadian Computed Tomography Survey: National Diagnostic Reference Levels

Purpose: The Canadian Computed (CT) Tomography Survey sought to collect CT technology and dose index data (CTDI and DLP) at the national level in order to establish national diagnostic reference levels (DRLs) for seven common CT examinations of standard-sized adults and pediatric patients. Methods: A single survey booklet (consisting of four sections) was mailed to and completed for each participating CT scanner. Survey sections collected data on (i) General facility and scanner information, (ii) routine protocols (as available), (iii) individual patient data (as applied) and (iv) manual CTDI measurements. Results: Dose index (CTDIvol and DLP) and associated patient data from 24 280 individual patient exam sequences was analyzed for seven common CT examinations performed in Canada: Adult Head, Chest, Abdomen/Pelvis, and Chest/Abdomen/Pelvis, and Pediatric Head, Chest, and Abdomen. Pediatric examination data was sub-divided into three age ranges: 0–3, 3–7 and 7–13 years. DRLs (75th percentile of dose index distributions) were found for all thirteen groups. Further analysis also permitted segmentation of examination data into 8 sub-groups, whose dose index data was displayed along with group histograms – showing relative contribution of axial vs. helical, contrast use (C+ vs. C-), and application of fixed current vs. dose reduction (DR) – 75th percentiles of DR sub-groups were, in almost all cases, lower than whole group (examination) DRLs. Conclusions: The analysis and summaries presented in the pending survey report can serve to aid local CT imaging optimization efforts within Canada and also contribute further to international efforts in radiation protection of patients.

60 APPLIED LIFE SCIENCES↗

Poster - 19: Investigation of Electron Reference Dosimetry Based on Optimal Chamber Shift

An addendum/revision to AAPM TG-51 electron reference dosimetry is highly expected to meet the clinical requirement with the increasing usage of new ion chambers not covered in TG-51. A recent study, Med. Phys. 41, 111701, proposed a new fitting equation for the beam quality conversion factor k’{sub Q} to a wide spectrum of chambers. In the study, an optimal Effective Point of Measurement (EPOM) from Monte Carlo calculations was recommended and the fitting parameters to k’{sub Q} was based on it. We investigated the absolute dose obtained based on the optimal EPOM method and the original TG-51 method with k’{sub R50} determined differently. The results showed that using the Markus curve is a better choice than the well-guarded chamber fitting for an IBA PPC-05 parallel plate chamber if we need to strictly follow the AAPM TG-51 protocol. We also examined the usage of the new fitting equation with measurement performed at the physical EPOM, instead of the optimal EPOM. The former is more readily determined and more practical in clinics. Our study indicated that the k’{sub Q} fitting based on the optimal EPOM can be used to measurement at the physical EPOM with no significant clinical impact. The inclusion of Farmer chamber gradient correction P{sub gr} in k’{sub Q}, as in the mentioned study, asks for the precise positioning of chamber center at dref. It is not recommended in clinics to avoid over-correction for low electron energies, especially for an institute having matching Linacs implemented.

60 APPLIED LIFE SCIENCES↗

Sci-Fri AM: MRI and Diagnostic Imaging - 02: Quality Improvement: Diagnostic Reference Levels for Interior Health CT exams – L-Spine, Chest/Abdomen/pelvis, Abdomen/Pelvis, Head

Diagnostic Reference Levels are used to optimize patient dose and image quality in the clinical setting. It is assumed that the majority of exams are of diagnostic quality, or the radiologists would request protocol adjustments. By investigating the dose indicator distributions from all scanners, the upper DRL can be set to the 75th percentile of the distribution and a lower DRL can be set to the 10th percentile. Scanners using doses consistently outside the upper/lower DRL range can be adjusted accordingly. 11 CT scanners, all contributing to the American College of Radiology Dose Index Registry (ACR DIR) were used in this study. Dose indicator data were compiled from the ACR DIR data and local DRLs established. Scanners with median doses outside the upper/lower DRL were followed-up with. Using effective dose and exam volumes, collective dose was determined before and after protocol adjustments to evaluate the effect of this quality improvement effort. The quality initiative is complete for L-spine and Chest/Abdomen/Pelvis exams and only initial surveys were completed for Head and Abdomen/Pelvis examsg. Median Scanner Dose reductions were 8.8 and 4.9 % for L-spine and Chest/Abdomen/Pelvis exams, respectively, resulting with collective dose reductions of 0.7 and 3.2 person•Sv/yr. Follow-up is ongoing for Abdomen/Pelvis and Head exams.

60 APPLIED LIFE SCIENCES↗

Sci-Sat AM: Radiation Dosimetry and Practical Therapy Solutions - 12: Suitability of plan class specific reference fields for estimating dosimeter correction factors for small clinical CyberKnife fields

Purpose: The purpose of this work is to investigate the utility of plan class specific reference (PCSR) fields for predicting dosimeter response within isocentric and non-isocentric composite clinical fields using the smallest fields employed by the CyberKnife radiosurgery system. Methods: Monte Carlo dosimeter response correction factors (CFs) were calculated for a plastic scintillator and microchamber dosimeter in 21 clinical fields and 9 candidate plan-class PCSR fields which employ the 5, 7.5 and 10 mm diameter collimators. Measurements were performed in 5 PCSR fields to confirm the predicted relative response of detectors in the same field. Results: Ratios of corrected measured dose in the PCSR fields agree to within 1% of unity. Calculated CFs for isocentric fields agree within 1.5% of those for PCSR fields. Large and variable microchamber CFs are required for non-isocentric fields, with differences as high as 5% between different clinical fields in the same plan class and 4% within the same field depending on the point of measurement. Non-isocentric PCSR fields constructed to have relatively homogenous dose over a region larger than the detector have very different ion chamber CFs from clinical fields. The plastic scintillator detector has much more consistent response within each plan class but still require 3–4% corrections in some fields. Conclusions: While the PCSR field concept is useful for small isocentric fields, this approach may not be appropriate for non-isocentric clinical fields which exhibit large and variable ion chamber CFs which differ significantly from CFs for homogenous field PCSRs.

61 RADIATION PROTECTION AND DOSIMETRY↗

Complete Genome Assembly of Reference Strain Ochrobactrum anthropi ATCC 49687

Ochrobactrum anthropi is an occasional cause of nosocomial infections; however, interest in the organism lies in its phylogenetic proximity to the genus Brucella. Here, we present the 4.9-Mb finished genome of Ochrobactrum anthropi ATCC 49687, most commonly used as an exclusionary reference organism.

59 BASIC BIOLOGICAL SCIENCES↗

Complete Genome Assembly of Enterococcus faecalis 29212, a Laboratory Reference Strain

Enterococcus faecalis is a nonmotile Gram-positive coccus, found both as a commensal organism in healthy humans and animals and as a causative agent of multiple diseases, in particular endocarditis. We sequenced the genome of E. faecalis ATCC 29212, a commonly used reference strain in laboratory studies, to complete “finished” annotated assembly (3 Mb).

59 BASIC BIOLOGICAL SCIENCES↗

Elementary reference for the analysis of high-energy nuclear collisions

In this contribution we shall discuss some aspects of the role of elementary reference data for the interpretation of the results from nuclear collisions and show in particular that neutron-proton interactions play a significant role. Furthermore we point out that a complete set of elementary data is desirable, because most theoretical concepts for the interpretation of nuclear collisions rely on such data as input for their calculations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Modeling of reference operating scenario of GOL-NB multiple-mirror trap

Currently, the GOL-NB multiple-mirror trap is being developed at the Budker Institute of Nuclear Physics, Siberian Branch, Russian Academy of Sciences. The main scientific goal pursued by building GOL-NB is direct demonstration of suppression of longitudinal losses of particles and energy from the trap by using sections with a multiple-mirror magnetic field, which can be attached to the central gas-dynamic trap. Plasma heating in GOL-NB will be accomplished by neutral beam injection with a power of up to 1.5MW. The paper presents the first results of modeling the dynamics of the plasma parameters and fast ions under the reference operating scenario of the trap in which traditional short magnetic mirrors, rather than multiple-mirror sections, are attached to the central trap. In such a configuration, the plasma lifetime in the trap is expected to be minimal. The modeling was performed by using the DOL kinetic code. As a result, the initial conditions of the experiments are refined and the requirements to the system of maintaining the particle balance in the trap are determined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Evaluation of Compton suppression for enhancing trace element identification in neutron activation analysis of reference materials

Neutron activation analysis (NAA) is a powerful technique for identifying and quantifying trace elements in materials. However, challenges such as high dead times, spectral interferences, and high Compton continuum often arise. This study employs a Compton suppression system (CSS) to enhance NAA sensitivity by reducing the Compton continuum, thereby improving the peak-to-Compton ratio. National Institute of Standards and Technology certified reference materials 1632d, 1633c, and Canadian National Research Council TORT-1 were irradiated in a thermal and epithermal neutron flux under various irradiation, decay and counting times and analyzed using high-resolution gamma-ray spectroscopy with and without Compton suppression. The reduction factor was calculated to evaluate the effectiveness of the CSS, demonstrating significant background reduction and improved detection limits for trace elements. Additional experiments with a 137Cs point source demonstrated the impact of detector-source geometry on system performance, showing a decrease in the reduction factor as the source was moved further from the NaI detector. An optimum distance between the source and HPGe detector was observed, yielding the highest peak-to-Compton ratio. The results highlight the CSS's ability to minimize spectral interference and enhance elemental identification.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Open SHMEM Reference Implementation

OpenSHMEM is an effort to create a specification for a standardized API for parallel programming in the Partitioned Global Address Space. Along with the specification the project is also creating a reference implementation of the API. This implementation attempts to be portable, to allow it to be deployed in multiple environments, and to be a starting point for implementations targeted to particular hardware platforms. It will also serve as a springboard for future development of the API.

Pritchard, Howard↗

Norms, Norm Sets, and Reference Groups: Implications for Household Interest in Energy Technologies

Household adoption of rooftop solar panels and battery storage can potentially reduce the negative environmental impacts of the electric grid. We argue that the number of socially close (friends and family) and geographically close (neighbors) others who have rooftop solar panels will affect norm expectations regarding how much others approve of solar panels and battery storage and expectations about how personally beneficial those technologies are likely to be. We test our hypotheses using survey data collected from California homeowners and find partial support. We find evidence for the significance of socially close others (rather than neighbors), highlighting the importance of identifying the appropriate reference groups when studying norms. Our results also provide insight into how one category of behavior (adoption of solar panels) can influence norm expectations about another less visible behavior (battery storage), suggesting a mechanism that may contribute to norms regulating private behaviors.

Horne, Christine↗

IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms

To date, the estimated radiation-absorbed dose to organs and tissues in patients undergoing diagnostic examinations in nuclear medicine is derived via calculations based on models of the human body and the biokinetic behaviour of the radiopharmaceutical. An internal dosimetry computer program, IDAC-Dose2.1, was developed based on the International Commission on Radiological Protection (ICRP)-specific absorbed fractions and computational framework of internal dose assessment given for reference adults in ICRP Publication 133. The program uses the radionuclide decay database of ICRP Publication 107 and considers 83 different source regions irradiating 47 target tissues, defining the effective dose as presented in ICRP Publications 60 and 103. The computer program was validated against another ICRP dosimetry program, Dose and Risk Calculation (DCAL), that employs the same computational framework in evaluation of occupational and environmental intakes of radionuclides. IDAC-Dose2.1 has a sub-module for absorbed dose calculations in spherical structures of different volumes and composition; this sub-module is intended for absorbed dose estimates in radiopharmaceutical therapy. For nine specific alpha emitters, the absorbed dose contribution from their decay products is also included in the committed absorbed dose calculations. The absorbed doses and effective dose of 131 I-iodide determined by IDAC-Dose2.1 were validated against the dosimetry program DCAL, showing identical results. IDAC-Dose2.1 was used to calculate absorbed doses for intravenously administered 18 F-FDG and orally administered 99m Tc-pertechnetate and 131 I-iodide, three frequently used radiopharmaceuticals. Using the tissue weighting factors from ICRP Publication 103, the effective dose per administered activity was estimated to be 0.016 mSv/MBq for 18 F-FDG, 0.014 mSv/MBq for 99m Tc-pertechnetate, and 16 mSv/MBq for 131 I-iodide. The internal dosimetry program IDAC-Dose2.1 was developed and applied to three radiopharmaceuticals for validation against DCAL and to generate improved absorbed dose estimations for diagnostic nuclear medicine using specific absorbed fraction values of the ICRP computational voxel phantoms. The sub-module for absorbed dose calculations in spherical structures 1 mm to 9 cm in diameter and different tissue composition was included to broaden the clinical usefulness of the program. The IDAC-Dose2.1 program is free software for research and available for download at http://www.idac-dose.org.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reference solutions for linear radiation transport: the Hohlraum and Lattice Benchmarks

Radiation transport describes the propagation of energetic particles through space as they interact with a surrounding material medium. In a kinetic description, radiation transport is modeled by a radiation transport equation (RTE) that prescribes the density of the radiation in position-momentum phase space. The purpose of this dataset is to provide highly resolved solutions to two benchmark problems. These two benchmarks do not possess exact solutions; moreover, the construction of a manufactured solution may require a non-physical source that is not desirable, especially if it spoils the physical nature of the solution. Thus the goal of this computational study is to provide a highly resolved reference solution for testing newer, more cost efficient methods that are currently being developed in the research community.

97 MATHEMATICS AND COMPUTING↗

Highly accurate Michelson type wavelength meter that uses a rubidium stabilized 1560 nm diode laser as a wavelength reference

We investigated the accuracy limitation of a wavelength meter installed in a vacuum chamber to enable us to develop a highly accurate meter based on a Michelson interferometer in 1550 nm optical communication bands. We found that an error of parts per million order could not be avoided using famous wavelength compensation equations. Chromatic dispersion of the refractive index in air can almost be disregarded when a 1560 nm wavelength produced by a rubidium (Rb) stabilized distributed feedback (DFB) diode laser is used as a reference wavelength. We describe a novel dual-wavelength self-calibration scheme that maintains high accuracy of the wavelength meter. The method uses the fundamental and second-harmonic wavelengths of an Rb-stabilized DFB diode laser. Consequently, a highly accurate Michelson type wavelength meter with an absolute accuracy of 5x10{sup -8} (10 MHz, 0.08 pm) over a wide wavelength range including optical communication bands was achieved without the need for a vacuum chamber.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Value of Information References

This file contains a list of relevant references on value of information (VOI) in RIS format. VOI provides a quantitative analysis to evaluate the outcome of the combined technologies (seismology, hydrology, geodesy) used to monitor Brady's Geothermal Field.

15 GEOTHERMAL ENERGY↗

Poroelastic references

This file contains a list of relevant references on the Biot theory (forward and inverse approaches), the double-porosity and dual-permeability theory, and seismic wave propagation in fracture porous media, in RIS format, to approach seismic monitoring in a complex fractured porous medium such as Brady?s Geothermal Field.

15 GEOTHERMAL ENERGY↗