Search NASA⌕ Search

SEARCH · Search NASA

Results for “Sample geometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

IN-PILE MEASUREMENTS OF FUEL ROD DIMENSIONAL CHANGES UTILIZING THE TEST REACTOR LOOP PRESSURE FOR MOTION

Different types of materials are being considered for fuel, cladding, and structures in existing and advanced nuclear reactors. These materials can undergo significant dimensional and physical changes during irradiation. Currently in the US, such changes are measured with the ‘cook and look’ method (i.e. repeatedly irradiating a specimen for a specified period of time and then removing it from the reactor for evaluation). The time and labor to remove, examine, and return irradiated samples for each measurement makes this approach expensive. In addition, such techniques provide limited data, and handling may disturb the phenomena of interest. Therefore, in-pile detection of changes in geometry is sorely needed to understand real-time behavior during irradiation testing of fuels and materials in high flux US Material and Test Reactors (MTRs). This paper presents development results of an advanced Linear Variable Differential Transformer (LVDT)-based test rig capable of detecting real-time changes in diameter or length of fuel rods or other material samples during irradiation in US MTRs. This test rig is being developed at the Idaho National Laboratory (INL), and will provide experimenters with a unique capability to measure dimensional changes associated with fuel and clad swelling, pellet-clad interaction, and crud buildup. This novel LVDT design uses the MTR’s loop pressure to drive the test specimen at a constant rate. This leads to a simplified construction, that is, the use of fewer components than other diameter gauge test rigs. This simplified design only requires three pressure boundary penetrations. Further, a key component of this test rig is a leak tight hydraulic ram capable of actuating under low differential pressure, and is able to survive the high irradiation tests at Pressurized Water Reactor (PWR) conditions. The sensor has been proven on a benchtop scale, and shows repeatability and reliability. Measurement accuracies of ±3 µm for diameter and ±90 µm for length have been achieved.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NbTaV_BCC_SolidSolution_128atoms_VASP6

We performed density functional theory (DFT) calculations for body-centered-cubic (BCC) structures with 128 lattices sites of solid solution ternary alloys niobium-tantalum-vanadium (Nb-Ta-V). The first-principle code that has been used to run the calculations is the closed-source Vienna Ab-Initio Simulation Package (VASP). The calculations have been collected by sampling chemical compositions across the entire compositional range. The chemical compositions have been sampled by progressively changing the number of atoms per constituent by 8. For each chemical composition of binaries and ternaries, the first-principle calculations have been run for 100 randomized arrangements of the constituents on the BCC lattice sites. We collected data for a total of 10,500 randomized atomic structures over 105 chemical compositions. The calculations have been collected on NERSC-Perlmutter using the VASP 6.3.2. The VASP calculations for every atomic structure have been performed in 2 main steps: 1. Starting from an ideal body-centered-cubic (BCC) structure, geometry optimization with low precision has been executed to perform a preliminary optimization of the atomic structure. The output for this calculations is available in the files 0.CONTCAR, 0.OUTCAR, rlx1.out. 2. Using the atomic structure resulting from the preliminary geometry optimization, a second geometry optimization has been performed using normal precision. The output for this calculations is available in the files CONTCAR, OUTCAR, rlx2.out, vaspout.h5, and vasprun.xml. Every chemical composition sampled across the composition range in the dataset has its own directory. The convention used to name the directories for ternary alloys is AXBYCZ, where A, B, and C refer to the constituents, and X, Y, and Z are positive integers that represent the number of atoms for each constituent and their values still sum up to 128. Each atomic structure associated with a specific chemical composition has its own sub-directory within the directory of the corresponding chemical composition. The sub-directories for each atomic structure for each chemical composition are named 'case-*', where * is a positive integer that spans all the values from 1 through 100, extremes included. The files contained in each sub-directory 'case-*' for each atomic structure are as follows: 1. INCAR: input file that contains various parameters and settings for controlling the behavior of the electronic structure calculations 2. 0.POSCAR: input file that defines the atomic structure of a system 3. 0.CONTCAR: output file that provides the atomic positions and cell parameters after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 4. 0.OUTCAR: output file that contains detailed information about the progress of a calculation after the first geometry optimization has been run with the precision variable set to PREC=Low in the INCAR file 5. rlx1.out: file with diagnostic information about the execution of the first geometry optimization with precision variable set to PREC=Low in the INCAR file 6. POSCAR: input file that defines the atomic structure of a system after the first geometry optimization has been run at low precision. This represents the input for the second geometry optimization run with the precision variable set to PREC=Normal in the INCAR file 7. CONTCAR: output file that provides the atomic positions and cell parameters after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 8. OUTCARL: output file that contains detailed information about the progress of a calculation after the second geometry optimization has been run with the precision variable set to PREC=Normal in the INCAR file 9. rlx2.out: file with diagnostic information about the execution of the second geometry optimization with precision variable set to PREC=Normal in the INCAR file 10. vaspout.h5: hierarchical HDF5 file containing the inputs and outputs of a VASP calculation. To analyze the data in this file we recommend using py4vasp. This file is only produced if the VASP version used is compiled with HDF5 support 11. vasprun.xml: contains similar information to OUTCAR, but in an xml format. This research is sponsored by the Artificial Intelligence Initiative as part of the Laboratory Directed Research and Development (LDRD) Program of Oak Ridge National Laboratory, managed by UT-Battelle, LLC, for the US Department of Energy under contract DE-AC05-00OR22725. This work used resources of the Oak Ridge Leadership Computing Facility, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC05-00OR22725, under Directorate Discretionary awards MAT025 (Materials Science) and LRN026 (Machine Learning), and INCITE award MAT201. This work also used resources of the National Energy Research Scientific Computing Center, which is supported by the Office of Science of the U.S. Department of Energy under Contract No. DE-AC02-05CH11231, under award ERCAP0025216.

36 MATERIALS SCIENCE↗

Variance Estimation in Monte Carlo Eigenvalue Simulations Using Spectral Analysis Method

The Monte Carlo (MC) method is the 'gold standard' for performing nuclear reactor calculations and criticality safety analyses because of its ability to handle complex geometries and physics. Reactor and criticality safety analyses require solving eigenvalue problems in complex nuclear systems. Once a stationary fission source distribution is obtained in MC simulations, the sample mean of many stationary cycles is calculated. The MC simulation sample mean is typically referred to as a tally. Variance, or standard deviation, of the sample mean/tally is needed to indicate the level of statistical uncertainty in the simulation and to understand the convergence of the sample mean. Current MC codes typically use sample variance to estimate the statistical uncertainty of the simulation and assume that the MC stationary cycles are independent. However, it is known that cycles are correlated, and estimators of the variance that ignore these correlations systematically underestimate the variance. In this paper, we propose a novel method in the Fourier frequency domain to estimate the variance of the sample mean in MC eigenvalue calculations. Results indicate that the proposed estimator can be unbiased compared to the real variance. The proposed estimator requires minimal additional computing effort.

42 ENGINEERING↗

Stochastic generation of explicit pore structures by thresholding Gaussian random fields

We provide a description and computational investigation of an efficient method to stochastically generate realistic pore structures. Smolarkiewicz and Winter introduced this specific method in pores resolving simulation of Darcy flows (Smolarkiewicz and Winter, 2010 [1]) without giving a complete formal description or analysis of the method, or indicating how to control the parameterization of the ensemble. We address both issues in this paper. The method consists of two steps. First, a realization of a correlated Gaussian field, or topography, is produced by convolving a prescribed kernel with an initial field of independent, identically distributed random variables. The intrinsic length scales of the kernel determine the correlation structure of the topography. Next, a sample pore space is generated by applying a level threshold to the Gaussian field realization: points are assigned to the void phase or the solid phase depending on whether the topography over them is above or below the threshold. Hence, the topology and geometry of the pore space depend on the form of the kernel and the level threshold. Manipulating these two user prescribed quantities allows good control of pore space observables, in particular the Minkowski functionals. Extensions of the method to generate media with multiple pore structures and preferential flow directions are also discussed. To demonstrate its usefulness, the method is used to generate a pore space with physical and hydrological properties similar to a sample of Berea sandstone. -- Graphical abstract: -- Highlights: •An efficient method to stochastically generate realistic pore structures is provided. •Samples are generated by applying a level threshold to a Gaussian field realization. •Two user prescribed quantities determine the topology and geometry of the pore space. •Multiple pore structures and preferential flow directions can be produced. •A pore space based on Berea sandstone is generated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Brazil disc Testing of LX-17-1

When considering alternate test methods for assessing the tensile performance of insensitive plastic bonded explosive (PBX) materials, Brazil disc tensile testing is attractive from several standpoints. First, compared to the traditional dog-bone shaped specimen normally used in the direct tensile test, the Brazil test specimen is considerably easier to produce. Second, the Brazil specimen is compact, with a low aspect ratio that allows it to be machined from a wide variety of pressed geometries. Assuming test results are consistent and interpretable, the method could open up possibilities for rapid assessment of ultimate tensile strengths, and might be especially attractive when a large number of samples are to be tested. The trade-off for specimen simplicity is, however, that interpretation of the results from Brazil tests is inherently far less intuitive, and more difficult, than is the case with traditional tensile testing, since the method involves complex stress loading. As a result, the derivation of what one hopes are equivalent tensile failure stresses from Brazil testing necessitates some fairly involved calculations, requiring parameters that are not always readily obtained. In addition to some significant uncertainties, the specimen geometry does not lend itself easily to the accommodation of traditional strain measurement devices such as extensometers. As a consequence, optical techniques such as digital image correlation (DIC) are preferred when stress-strain curves are needed. In this test series we performed a sequence of experiments using Brazil discs made from LX-17-1. Tests were performed on samples at two different scaled sizes: discs that were 0.5 inches in diameter and 0.25 inch thick, and discs that were 1 inch in diameter and a 0.5 inch thick. Each of the specimen sets was tested using matching, equivalently scaled test fixtures, each with anvils whose radii were 0.25% greater than their respective specimen radii. All specimens tested were machined from billet pressed material made from Holston #851009 (LLNL tag #C-329) LX-17-1 molding powder. Tests were performed at two temperatures, +23 °C and +50 °C, with three each test redundancies at each condition. Based on data from this set of experiments we hoped to provide preliminary answers to a number of questions, including: 1) Roughly, what is the level of scatter in the data? 2) Are results scale independent, at least within the limited range of specimen sizes tested? 3) Using a consistent set of parameters, can we use the equations given by Sato and Awaji1 to calculate peak tensile stresses that are nearly equivalent to those measured using traditional dog-bone tensile testing methods.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

SU-E-I-100: Heterogeneity Studying for Primary and Lymphoma Tumors by Using Multi-Scale Image Texture Analysis with PET-CT Images

Purpose: The purpose of this research is studying tumor heterogeneity of the primary and lymphoma by using multi-scale texture analysis with PET-CT images, where the tumor heterogeneity is expressed by texture features. Methods: Datasets were collected from 12 lung cancer patients, and both of primary and lymphoma tumors were detected with all these patients. All patients underwent whole-body 18F-FDG PET/CT scan before treatment.The regions of interest (ROI) of primary and lymphoma tumor were contoured by experienced clinical doctors. Then the ROI of primary and lymphoma tumor is extracted automatically by using Matlab software. According to the geometry size of contour structure, the images of tumor are decomposed by multi-scale method.Wavelet transform was performed on ROI structures within images by L layers sampling, and then wavelet sub-bands which have the same size of the original image are obtained. The number of sub-bands is 3L+1.The gray level co-occurrence matrix (GLCM) is calculated within different sub-bands, thenenergy, inertia, correlation and gray in-homogeneity were extracted from GLCM.Finally, heterogeneity statistical analysis was studied for primary and lymphoma tumor using the texture features. Results: Energy, inertia, correlation and gray in-homogeneity are calculated with our experiments for heterogeneity statistical analysis.Energy for primary and lymphomatumor is equal with the same patient, while gray in-homogeneity and inertia of primaryare 2.59595±0.00855, 0.6439±0.0007 respectively. Gray in-homogeneity and inertia of lymphoma are 2.60115±0.00635, 0.64435±0.00055 respectively. The experiments showed that the volume of lymphoma is smaller than primary tumor, but thegray in-homogeneity and inertia were higher than primary tumor with the same patient, and the correlation with lymphoma tumors is zero, while the correlation with primary tumor isslightly strong. Conclusion: This studying showed that there were effective heterogeneity differences between primary and lymphoma tumor by multi-scale image texture analysis. This work is supported by National Natural Science Foundation of China (No. 61201441), Research Fund for Excellent Young and Middle-aged Scientists of Shandong Province (No. BS2012DX038), Project of Shandong Province Higher Educational Science and Technology Program (No. J12LN23), Jinan youth science and technology star (No.20120109)

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mechanisms of material removal and mass transport in focused ion beam nanopore formation

Despite the widespread use of focused ion beam (FIB) processing as a material removal method for applications ranging from electron microscope sample preparation to nanopore processing for DNA sequencing, the basic material removal mechanisms of FIB processing are not well understood. We present the first complete atomistic simulation of high-flux FIB using large-scale parallel molecular dynamics (MD) simulations of nanopore fabrication in freestanding thin films. We focus on the root mechanisms of material removal and rearrangement and describe the role of explosive boiling in forming nanopores. FIB nanopore fabrication is typically understood to occur via sputter erosion. This can be shown to be the case in low flux systems, where individual ion impacts are sufficiently separated in time that they may be considered as independent events. But our detailed MD simulations show that in high flux FIB processing, above a threshold level at which thermal effects become significant, the primary mechanism of material removal changes to a significantly accelerated, thermally dominated process. Under these conditions, the target is heated by the ion beam faster than heat is conducted away by the material, leading quickly to melting, and then continued heating to nearly the material critical temperature. This leads to explosive boiling of the target material with spontaneous bubble formation and coalescence. Mass is rapidly rearranged at the atomistic scale, and material removal occurs orders of magnitude faster than would occur by simple sputtering. While the phenomenology is demonstrated computationally in silicon, it can be expected to occur at lower beam fluxes in other cases where thermal conduction is suppressed due to material properties, geometry, or ambient thermal conditions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Magnetotransport Properties of High Quality Co:ZnO and Mn:ZnO Single Crystal Pulsed Laser Deposition films: Pitfalls Associated with Magnetotransport on High Resistivity Materials

The electrical resistivity values for a series of pure and doped (Co, Mn, Al) ZnO epitaxial films grown by pulsed laser deposition were measured with equipment designed for determining the DC resistivity of high resistance samples. Room-temperature resistances ranging from 7x10^1 ohms/square to 4x10^8 ohms/square were measured on vacuum-reduced cobalt-doped ZnO, (Al,Co) co-doped ZnO, pure cobalt-doped ZnO, Mn-doped ZnO, and undoped ZnO. Using a four-point collinear geometry with gold spring-pin contacts, resistivities were measured from 295 to 5 K for resistances of < ~10^12 ohms/square. In addition, magnetoresistance (MR) and Hall effect were measured as a function of temperature for select samples. Throughout the investigation, samples were also measured on commercially available instrumentation with good agreement. The challenges of transport measurements on high resistivity samples are discussed, along with some offered solutions to those challenges.

36 MATERIALS SCIENCE↗

ELISA: A Tool for Optimization of Rotor Hover Performance at Low Reynolds Number in the Mars Atmosphere

The Evolutionary aLgorithm for Iterative Studies of Aeromechanics (ELISA) was developed in support of the Rotorcraft Optimization for the Advancement of Mars eXploration (ROAMX) project. ELISA was developed to enable aerodynamic rotor hover optimization for low Reynolds number flows in the Mars atmosphere. The first objective of the algorithm allows for unconventional airfoil parameterization and multi-objective airfoil geometry optimization using OVERFLOW. The Pareto-optimal airfoil sets are converted to a set of Pareto-optimal airfoil decks, providing the lowest drag air foil geometry for each angle of attack, removing the need to arbitrarily select the airfoils to be used in the rotor optimization. The second objective allows for rotor geometry optimization with simultaneous maximization of blade loading and minimization of rotor power using the comprehensive analysis CAMRADII. The result is a Pareto-optimal rotor set, providing the lowest power rotor for each attainable blade loading, and one of the first tools for hover-optimized rotors for high-subsonic low Reynolds number conditions. The airfoil thickness can be modified after the airfoil optimization is complete, allowing for a post-airfoil-optimization adjustment of blade thickness to facilitate conforming to external structural analyses requirements. The relevance of the code is demonstrated with case studies for the ROAMX rotor optimization for Ingenuity-sized single rotors in the Mars atmosphere, a performance study optimizing the chord and twist of Ingenuity’s coaxial rotor resulting in the Sample Recovery Helicopters candidate rotor, and high-subsonic low Reynolds number airfoil optimization providing novel insights for higher-efficiency low Reynolds number airfoil geometries and flow physics.

ELISA↗

Modular Design of High Temperature and Pressure Heat Exchangers Using 3D Printing

Functionally graded material (FGM), leveraged by latest additive manufacturing (AM) technologies, can add significant values to high temperature applications such as the HTR in supercritical sCO2 Brayton cycles. The project was focused on fabricating FGMs with complex geometries such as flow channels using DED and L-PBF technologies to support the modular design concept in achieving high-performance and low-cost high temperature recuperators for the sCO2 Brayton cycle. Samples printed from the base materials including both SS 316 and Inconel 625 have mostly met the material standards. L-PBF samples have achieved the fine feature sizes with good geometrical accuracy. In addition, DED has demonstrated its printability on LPBF part with both direct transition and using 50/50 mixed powders. Despite various challenging, the project helped advance the current state-of-the-art of DED technology in terms of printing fine geometries.

14 SOLAR ENERGY↗

An Open-Cell Environmental Transmission Electron Microscopy Technique for In Situ Characterization of Samples in Aqueous Liquid Solutions

The desire to image specimens in liquids has led to the development of open-cell and closed-cell techniques in transmission electron microscopy (TEM). The closed-cell approach is currently more common in TEM and has yielded new insights into a number of biological and materials processes in liquid environments. The open-cell approach, which requires an environmental TEM (ETEM), is technically challenging but may be advantageous in certain circumstances due to fewer restrictions on specimen and detector geometry. Here, we demonstrate a novel approach to open-cell liquid TEM, in which we use salt particles to facilitate the in situ formation of droplets of aqueous solution that envelope specimen particles coloaded with the salt. This is achieved by controlling sample temperature between 1 and 10°C and introducing water vapor to the ETEM chamber above the critical pressure for the formation of liquid water on the salt particles. Our use of in situ hydration enables specimens to be loaded into a microscope in a dry state using standard 3 mm TEM grids, allowing specimens to be prepared using trivial sample preparation techniques. Furthermore, our future aim will be to combine this technique with an in situ light source to study photocorrosion in aqueous environments.

47 OTHER INSTRUMENTATION↗

Digital Twin Model for Advanced Manufacture of a Rotating Detonation Engine Injector

A digital twin material model (DTMM) of an additive manufacturing (AM) process was created to advance the state of the art in rotating detonation engine (RDE) injector design. Current RDE injectors are designed with large pressure drops, enabling a stable and repeatable combustion process. However, this comes at the cost of system efficiency. For the technology to transition to commercial fossil-based power generation, it is important to develop injectors with reduced flow losses. Low-loss injectors are difficult to design and manufacture with conventional manufacturing techniques. AM enables new design options, but the AM manufacturing process must be thoroughly understood to result in a robust design. A DTMM provides the necessary insight by defining the cause-effect relationships between process parameters, microstructure features, and properties. Therefore, a DTMM to support the design and manufacturing process was developed and applied to the design of a new additively manufactured low-loss injector. The injector combustion behavior was characterized through hot-fire tests, and mechanical performance was compared to the DTMM predictions. The two project goals were the successful development of the DTMM and the demonstration of an improved RDE injector design. The RDE injector design and DTMM developments occurred on parallel but dependent paths. The injector was designed to reduce pressure drop by increasing the cross-sectional flow area ratio between the injector air passages and the combustor annulus. This resulted in less structural material, raising the concern that thin members would be susceptible to high-cycle fatigue (HCF) under the periodic loading inherent to an RDE. It was most important for the DTMM to predict behavior in these features; therefore, the injector design concept guided the material thicknesses used in fatigue tests. The DTMM development started by manufacturing a series of coupons over the range of possible AM process variations. A design-of-experiment approach was used to select which process variable combinations gave the most efficient coverage relevant to the injector design space. The microstructure in each of these coupons was characterized, and then computational methods were used to create a numerical model of the correlation between process variables and microstructure. Next, a set of HCF samples were tested to calibrate existing models that map microstructure to HCF performance. Together, these two links formed the DTMM that calculates HCF behavior from AM process variables. Two injector prototypes were additively manufactured. The first injector design strategy aggressively pursued low-loss performance by substantially increasing the oxidizer flow area. The combination of manufacturing lead times and the fatigue testing schedule meant that the DTMM was not available when building this first prototype. Therefore, its process parameters were chosen based on a manual review of the available coupon data. This prototype was built successfully and evaluated in 58 combustion tests. Sustained detonation was achieved with remarkably reduced pressure loss, and some tests even displayed pressure loss characteristics similar to conventional gas turbine combustors. This achieved the project goal of improving RDE injector design. The second injector was manufactured according to the optimized parameters predicted by the DTMM. The flow area modifications of this injector were less aggressive than the first injector since demonstrating low pressure loss was not an objective of the second hot-fire test series. Rather, the test objective was to cause high cycle fatigue failure in the part due to periodic loading from the rotating detonation wave. The observed number of cycles to failure was to be compared to the number predicted by the DTMM and thereby assess the utility of the DTMM in component design. However, the required level of vibration was not obtained during combustion. Therefore, high cycle fatigue was not experienced in the hot-fire tests of the second injector. Fatigue data was obtained by further testing the second injector in a conventional HCF test apparatus. The injector demonstrated HCF strength above the DTMM prediction. In fact, it did not fail and testing was only discontinued due to reaching the end of the period of performance. This points to some success in the project’s primary goal of successfully developing and applying the DTMM to a component design. Implementing the DTMM recommendations for optimal processing parameters led to a part with acceptable properties. The DTMM was also shown to be an efficient correlator of data and to provide insight into the relationship between process settings, microstructure, and property performance. However, the failure of the DTMM prediction to match the experimental result of the injector fatigue test also points to the need to include significantly more data in the model development. In this project, coupons made with identical processing parameters exhibited drastically different properties from each other and from the injector part, which clearly influences the accuracy of a model that predicts performance based on parameters. Uncertainties in the build process must be quantified to develop more robust models. A denser and broader matrix of coupon process and geometry variations, several repeated builds of every point, more in-situ build process measurements, and direct observation of tensile and HCF sample microstructure (as opposed to separate microstructure specimens) are recommendations to improve future AM modeling efforts.

20 FOSSIL-FUELED POWER PLANTS↗

Intensity-Modulated Radiotherapy Optimization in a Quasi-Periodically Deforming Patient Model

Purpose: To present the implementation of a probability-based, four-dimensional (4D) intensity-modulated radiotherapy (IMRT) planning approach that explicitly optimizes the accumulated dose to moving tissue, estimated using the patient's probability density function (pdf) of respiratory motion. This is termed 'optimization in tissue's-eye-view'. Methods and Materials: The method incorporates 4D Monte Carlo dose calculation in multiple geometries of a respiratory-correlated CT dataset. The instance doses are weighted according to the breathing pdf and accumulated in a common reference geometry, which involves dose warping based on deformable registration. The algorithm produces deliverable multileaf collimator segments and was tested on a sample lung cancer patient dataset with large target excursion. Accumulated doses of the moving target and organs at risk of this plan were compared with those of corresponding margin-based static IMRT plans for free-breathing and gated treatment, as well as target tracking. Results: Target tracking provided best target coverage. Both the presented 4D IMRT approach for free-breathing treatment and gated treatment gave similar results for target coverage and lung dose, with significantly better target coverage than the margin-based static IMRT plan for free-breathing treatment. Conclusions: The presented 4D planning concept offers an alternative to gating by providing the optimal dose for free-breathing IMRT treatment. Although the focus of this study was 4D lung planning, the approach can be generally applied for IMRT optimization in randomly deforming patient models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of Geant4 Monte Carlo simulation in dose calculations for small radiosurgical fields

The Geant4 toolkit was used to develop a Monte Carlo (MC)-based engine for accurate dose calculations in small radiation field sizes. The Geant4 toolkit (version 10.1.p02) was used to simulate 6-MV photon beam of a Varian2100C linear accelerator that is being used for stereotactic radiosurgery (SRS) treatment with small radiation fields. Geometric models of 3 in-house designed radiosurgical divergent cones, with the diameters of their projections at the isocenter being 10, 20, and 30 mm, were simulated. The accuracy of the MC simulation technique was examined by reproducing several different simulated dosimetric parameters of the primary beams with the experimental data. The dose distributions are first checked for single beams for each cone, then standard multiple field (SMF) techniques are applied. A sample set of DICOM files from computed tomography (CT) scan imaging of a patient's head was converted to the Geant4 geometry format to implement MC-based engine for a clinical test. To validate the accuracy of the MC-based calculations for SMF arrangements, the isodose lines from MC simulation in water phantom were compared with the measured isodose lines using EBT3 Gafchromic film in Solid Water phantoms. Agreements between measured and simulated depth dose values and beam profiles for SRS cones were generally within 2%/2 mm. For output factors, the largest discrepancy was observed for 10 mm SRS cone, which was 1.7%. For SMF techniques, in SRS cones, the MC simulation and EBT3 Gafchromic film dosimetry were in acceptable agreement (5%/5 mm). Excellent agreement between the results of the MC-based and measured dose values for both single and SMF techniques in SRS cones indicates the ability of the Geant4 toolkit to be applied as the platform for treatment planning of advanced radiotherapy techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Crystal Structures, Optical Behavior, and Magnetic Properties in Hydrated Lanthanide Iron Sulfates

Single crystals of LnFe(SO 4 ) 3 (H 2 O) 2 (Ln = La, Ce, Pr, Nd, Sm, Eu, Gd, Dy, Ho, Er, Tm; compounds 1–11) and LnFe(SO 4 ) 3 (H 2 O) (Ln = Tm, Yb, Lu; compounds 12–14) were synthesized under hydrothermal conditions. Single-crystal X-ray diffraction (SCXRD) analysis revealed that the dihydrated compounds (1–11) crystallize in centrosymmetric (CS) structures, with the lanthanide ions adopting eight-coordinate geometries. In contrast, the monohydrated compounds (12–14) exhibit noncentrosymmetric (NCS) structures, where the lanthanide ions are seven-coordinated. Vibrating sample magnetometry (VSM) confirmed that compounds 2, 4, and 7–11 are paramagnetic below 400 K, with compound 8 displaying the highest magnetic susceptibility. Compounds 1, 5, 6, 13, and 14 show a sharp increase in magnetic susceptibility at Néel temperatures ( T N ) of approximately 72, 76, 70, 58, and 56 K, respectively, indicating antiferromagnetic ordering. High-temperature magnetic susceptibility measurements further support the presence of antiferromagnetic transitions in these compounds. Second harmonic generation (SHG) measurements showed that the noncentrosymmetric Yb (compound 13) and Lu (compound 14) compounds exhibit SHG intensities of 0.3× and 1.6× that of potassium dihydrogen phosphate (KDP), respectively.

anions↗

Analysis of Individual Terrestrial Gamma‐Ray Flashes With Lightning Leader Models and Fermi Gamma‐Ray Burst Monitor Data

Abstract The Gamma‐ray Burst Monitor (GBM) onboard the Fermi spacecraft has observed many tens of sufficiently bright events, which are suitable for individual analysis. In our previous study, we fit individual, bright terrestrial gamma‐ray flashes (TGFs) with Relativistic Runaway Electron Avalanche (RREA) models for the first time. For relativistic‐feedback‐based models, the TGF‐producing electrons, which are seeded internally by a positive feedback effect, are usually accelerated in a large‐scale field with fully developed RREAs. Alternatively, lightning leader models may apply to either a large‐scale thunderstorm fields with fully developed RREAs or to inhomogeneous fields in front of lightning leaders where RREAs only develop partially. The predictions of the latter, inhomogeneous models for the TGF‐beaming geometry show some differences from estimations of the relativistic feedback models in homogeneous fields. In this work, we analyze a large sample of 66 bright Fermi GBM TGFs in the framework of lightning leader models, making comparisons with previous results from the homogeneous‐field RREA models. In most cases, the spectral analysis does not strongly favor one mechanism over the other, with 59% of the TGF events being best fit with the fully developed RREA mechanism, which corresponds to high‐potential leader models. The majority of the GBM‐measured TGFs can be best fit if the source altitude is below 15 km and 70% of events best fit by leader models cannot be satisfactorily modeled unless a tilted photon beam is used. For several spectrally soft TGFs, the tilted beam low‐potential leader model can best fit the data.

Mailyan, B. G.↗

Use of a multichannel collimator for structural investigation of low-Z dense liquids in a diamond anvil cell: Validation on fluid H{sub 2} up to 5 GPa

We report the first application of a multichannel collimator (MCC) to perform quantitative structure factor measurements of dense low-Z fluids in a diamond anvil cell (DAC) using synchrotron x-ray diffraction. The MCC design, initially developed for the Paris-Edinburgh large volume press geometry, has been modified for use with diamond anvil cells. A good selectivity of the diffracted signal of the dense fluid sample is obtained due to a large rejection of the Compton diffusion from the diamond anvils. The signal to background ratio is significantly improved. We modify previously developed analytical techniques for quantitative measurement of the structure factor of fluids in DACs [J. H. Eggert, G. Weck, P. Loubeyre, and M. Mezouar, Phys. Rev. B 65, 174105 (2002)] to account for the contribution of the MCC. We present experimental results on liquids argon and hydrogen at 296 K to validate our method and test its limits, respectively.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗