Search NASA⌕ Search

SEARCH · Search NASA

Results for “Signal Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Earth-Based Radio Tracking of the Galileo Probe for Jupiter Wind Estimation

Although the Galileo probe was designed to communicate only to the orbiter, the probe radio signal was detected at two Earth-based radio observatories where the signal was a billion times weaker. The measured signal frequency was used to derive a vertical profile of the jovian zonal wind speed. Due to the mission geometry, the Earth-based wind estimates are less sensitive to descent trajectory errors than estimates based on probe-orbiter Doppler measurements. The two estimates of wind profiles agree qualitatively; both show high wind speeds at all depths sampled.

Folkner, W. M.↗

Patient ECG recording control for an automatic implantable defibrillator

An implantable automatic defibrillator includes sensors which are placed on or near the patient's heart to detect electrical signals indicative of the physiology of the heart. The signals are digitally converted and stored into a FIFO region of a RAM by operation of a direct memory access (DMA) controller. The DMA controller operates transparently with respect to the microprocessor which is part of the defibrillator. The implantable defibrillator includes a telemetry communications circuit for sending data outbound from the defibrillator to an external device (either a patient controller or a physician's console or other) and a receiver for sensing at least an externally generated patient ECG recording command signal. The patient recording command signal is generated by the hand held patient controller. Upon detection of the patient ECG recording command, DMA copies the contents of the FIFO into a specific region of the RAM.

Fountain, Glen H.↗

Electrochemical sensing using voltage-current time differential

A device for signal processing. The device includes a signal generator, a signal detector, and a processor. The signal generator generates an original waveform. The signal detector detects an affected waveform. The processor is coupled to the signal detector. The processor receives the affected waveform from the signal detector. The processor also compares at least one portion of the affected waveform with the original waveform. The processor also determines a difference between the affected waveform and the original waveform. The processor also determines a value corresponding to a unique portion of the determined difference between the original and affected waveforms. The processor also outputs the determined value.

99 GENERAL AND MISCELLANEOUS↗

Electromagnetic Signals Following Stellar-mass Black Hole Mergers

It is often assumed that gravitational-wave (GW) events resulting from the merger of stellar-mass black holes are unlikely to produce electromagnetic (EM) counterparts. We point out that the progenitor binary has probably shed a mass ≳10 M {sub ⊙} during its prior evolution. If even a tiny fraction of this gas is retained in a circumbinary disk, the sudden mass loss and recoil of the merged black hole shocks and heats it within hours of the GW event. Whether the resulting EM signal is detectable is uncertain. The optical depth through the disk is likely to be high enough that the prompt emission consists only of photons from its optically thin skin, while the majority may take years to emerge. However, if some mechanism can release more photons in a time comparable to the few-hour energy production time, the peak luminosity of the EM signal could be detectable. For a disk retaining only ∼10{sup −3} of the mass shed in the earlier binary evolution, medium-energy X-rays to infrared emission would be observable hours after the GW event for source distances of ∼500 Mpc. Events like this may already have been observed, but ascribed to unidentified active galactic nuclei. Improved sky localization should eventually allow identification based on spatial coincidence. A detection would provide unique constraints on formation scenarios and potentially offer tests of strong-field general relativity. Accordingly, we argue that the high scientific payoff of an EM detection fully justifies search campaigns.

79 ASTRONOMY AND ASTROPHYSICS↗

Methods and Apparatus for Detecting Defects in an Object of Interest

A method for detecting defects in an object of interest comprises applying an ultrasonic signal including a tone burst having a predetermined frequency and number of cycles into an object of interest, receiving a return signal reflected from the object of interest, and processing the return signal to detect defects in at least one inner material. The object may have an outer material and the at least one inner material that have different acoustic impedances. An ultrasonic sensor system includes an ultrasonic sensor configured to generate an ultrasonic signal having a tone burst at a predetermined frequency corresponding to a resonant frequency of an outer material of an object of interest.

Hartman, John K.↗

Peripheral and central localization of the nesfatin-1 receptor using autoradiography in rats

Nesfatin-1 was recently identified and introduced as food intake-regulatory hormone. Soon thereafter, mounting evidence indicated a much broader role for nesfatin-1 with an involvement in the regulation of food intake, gastrointestinal motility, glucose homeostasis, blood pressure and stress. Despite the growing knowledge on the physiological regulation and functions of nesfatin-1, the receptor mediating these effects remains to be characterized. Therefore, the aim of this study was to investigate the peripheral and central localization of the nesfatin-1 receptor by autoradiography. Male Sprague–Dawley rats were used and peripheral as well as brain tissue was processed for {sup 125}I-nesfatin-1 autoradiography. In peripheral tissues, an autoradiographic signal was observed in the gastric mucosa of corpus and antrum, in duodenum, jejunum and ileum, while no signal was detected in the colon. Preabsorption of {sup 125}I-nesfatin-1 with non-labeled nesfatin-1 greatly diminished the autoradiographic signal in the stomach indicating specificity (−32%, p < 0.001). A displacement assay showed an effective concentration by which 50% of {sup 125}I-nesfatin-1 bound to the receptor (EC{sub 50}) in the gastric corpus of 80 pM. Moreover, autoradiography was observed in endocrine tissues including the pituitary, pancreas, adrenal gland, testis and visceral adipose tissue. In addition, also heart, skeletal muscle, lung, liver and kidney showed autoradiographic signals. In the brain, strong {sup 125}I-nesfatin-1 autoradiography was detected in the cortex, paraventricular nucleus of the hypothalamus, area postrema, dorsal motor nucleus of the vagus nerve and cerebellum. Based on the distribution of nesfatin-1 autoradiography, nesfatin-1 is a pleiotropic hormone that is involved in the regulation of several homeostatic functions. - Highlights: • Although our knowledge on nesfatin-1 is increasing, the receptor is still unknown. • {sup 125}I-nesfatin-1 autoradiography was detected in (a.o.) the stomach and pancreas. • Central signals were observed in the hypothalamic paraventricular and dorsal motor nucleus. • Distribution data support the notion of nesfatin-1 being a pleiotropic hormone.

60 APPLIED LIFE SCIENCES↗

Chasing Gamma-Ray Signals from Binary Neutron Star Coalescences with the Cherenkov Telescope Array: Prospects and Observing Strategies

The detection of gravitational waves (GWs) from a binary neutron star (BNS) merger by Advanced LIGO and Advanced Virgo (GW170817), together with its electromagnetic counterpart, the short gamma-ray burst GRB 170817A, heralded the birth of multimessenger astronomy. The detection of TeV emission from GRBs motivates follow-up observations with the Cherenkov Telescope Array Observatory (CTAO), which is ideal for detecting such signals due to its unprecedented sensitivity, rapid response, and wide-field survey capabilities. The aim of this work is to evaluate GeV–TeV GW follow-up strategies for CTAO using a multistep simulation pipeline and to estimate the expected rate of joint GW–GRB detections during observing run O5. Using a simulated sample of BNS systems with corresponding GW detections, gamma-ray emission is simulated through phenomenological prescriptions based on the observed population of short GRBs, including off-axis jet scenarios. CTAO observations are simulated to account for instrument response, sky tiling strategies, integration times, and varying observing conditions. Strategies with variable and constant integration times are investigated. We find that, via an optimized follow-up strategy, about 5% of simulated GW-associated short GRBs produce GeV–TeV radiation detectable by CTAO. Detectability is strongly influenced by the jet opening angle and viewing angle, suggesting that even rough estimates of the viewing angle in GW alerts could enhance targeting. This framework motivates future follow-ups of GW-detectable events, including neutron star–black hole mergers, and further supports the development of advanced strategies incorporating galaxy distributions and synergies with future detectors such as the Einstein Telescope.

Abe, S. [University of Tokyo] (ORCID:0000000172503↗

High temperature ion channels and pores

The present invention includes an apparatus, system and method for stochastic sensing of an analyte to a protein pore. The protein pore may be an engineer protein pore, such as an ion channel at temperatures above 55.degree. C. and even as high as near 100.degree. C. The analyte may be any reactive analyte, including chemical weapons, environmental toxins and pharmaceuticals. The analyte covalently bonds to the sensor element to produce a detectable electrical current signal. Possible signals include change in electrical current. Detection of the signal allows identification of the analyte and determination of its concentration in a sample solution. Multiple analytes present in the same solution may also be detected.

Kang, Xiaofeng↗

High temperature ion channels and pores

The present invention includes an apparatus, system and method for stochastic sensing of an analyte to a protein pore. The protein pore may be an engineer protein pore, such as an ion channel at temperatures above 55° C. and even as high as near 100° C. The analyte may be any reactive analyte, including chemical weapons, environmental toxins and pharmaceuticals. The analyte covalently bonds to the sensor element to produce a detectable electrical current signal. Possible signals include change in electrical current. Detection of the signal allows identification of the analyte and determination of its concentration in a sample solution. Multiple analytes present in the same solution may also be detected.

Kang, Xiaofeng↗

Constraints on the polarization angle oscillations of the Crab Nebula with the Simons Array and its applications to the search for axionlike particles

Here, we present a search for polarization oscillation of the Crab Nebula, also known as Tau A, at millimeter wavelengths using observations with the Simons Array, the successor experiment to POLARBEAR. We follow up on previous work by POLARBEAR using 90 GHz band data of the 2023 observing season of the Simons Array to evaluate the variability of Tau A’s polarization angle. Tau A is widely used as a polarization angle calibration source in millimeter-wave astronomy, and thus it is necessary to validate the stability. Additionally, an interesting application of the time-resolved polarimetry of Tau A is to search for axionlike particles (ALPs). We do not detect a global signal across the frequencies considered in this analysis and place a median 95% upper bound of polarization oscillation amplitude A < 0.12° over oscillation frequencies from 3.39 yr -1 to 1.50 day -1 . This constrains the ALP-photon coupling at a median 95% upper bound of g aγγ < 3.84 × 10 -12 × (m a /10 -21 eV) in the mass range from 4.4 × 10 -22 to 7.2 × 10 -20 eV, assuming the ALP constitutes all of dark matter, its field is a stochastic Gaussian field, and it is the sole source of Tau A’s polarization angle oscillation. Additionally, we do not detect signal at the frequencies where 2.5σ hints were previously reported by POLARBEAR, but we do not exclude these signals at the 95% confidence level.

Adkins, Tylor [University of California, Berkeley]↗

June 2017 Ancho Canyon RF Collects: Final Report

We report the results from the June 8, 2017, Ancho Canyon RF collection. While bright, electromagnetic signals were seen close to the firing point, there were no detections of signals from the explosively-fired fuse (EFF) at a collection point about 600m distant on the East Mesa. The East Mesa site was unable to collect data because the uninterruptible power supply (UPS) was exhausted by the time of the shot. We did see signals from the EFF at the Bunker 57 antennas, about 123m distant from the Point 88 firing point. The strength of these signals is consistent with our limited knowledge of the collection antenna performance and the use of the standard model to predict the electric field strength. From our knowledge of the geometry of the EFF loop and the current in the loop in this test, and from measurements at the Bunker 57 site, we predict that we would have seen signals of about 50mV at 3.67MHz in a 100 kHz channel on the Rohde & Schwarz HE010 antennas at the East Mesa location. The noise oor there is about 0.113mV (based on the March 2017 collects). Thus we would have had an SNR of 53 dB from the collect, had the data collection system been running.

58 GEOSCIENCES↗

Laboratory simulation of Venusian lightning

Evidence of lightning activity in the Venusian atmosphere has been obtained from the Venera 9, 11, and 12 spacecraft, and from the Pioneer Venus Orbiter (PVO). However, a search for optical pulses expected from Venusian lightning using the star sensor on the PVO did not detect any signals. It has been suggested that the star sensor did not detect lightning because Venusian lightning does not radiate in the 500- to 900-nm spectral region detected by the star sensor. In this paper, spectra obtained from a laboratory simulation of Venusian lightning are discussed. Both the laboratory spectrum and the results of a theoretical calculation of line intensities show that Venusian lightning can be expected to radiate strongly in the 600- to 900-nm spectral region. Hence, the failure of the star sensor to detect lightning must be caused by the low flashing rate or by the low intensity of Venusian lightning.

Borucki, W. J.↗

Multi-Sensor Mud Detection

Robust mud detection is a critical perception requirement for Unmanned Ground Vehicle (UGV) autonomous offroad navigation. A military UGV stuck in a mud body during a mission may have to be sacrificed or rescued, both of which are unattractive options. There are several characteristics of mud that may be detectable with appropriate UGV-mounted sensors. For example, mud only occurs on the ground surface, is cooler than surrounding dry soil during the daytime under nominal weather conditions, is generally darker than surrounding dry soil in visible imagery, and is highly polarized. However, none of these cues are definitive on their own. Dry soil also occurs on the ground surface, shadows, snow, ice, and water can also be cooler than surrounding dry soil, shadows are also darker than surrounding dry soil in visible imagery, and cars, water, and some vegetation are also highly polarized. Shadows, snow, ice, water, cars, and vegetation can all be disambiguated from mud by using a suite of sensors that span multiple bands in the electromagnetic spectrum. Because there are military operations when it is imperative for UGV's to operate without emitting strong, detectable electromagnetic signals, passive sensors are desirable. JPL has developed a daytime mud detection capability using multiple passive imaging sensors. Cues for mud from multiple passive imaging sensors are fused into a single mud detection image using a rule base, and the resultant mud detection is localized in a terrain map using range data generated from a stereo pair of color cameras.

Rankin, Arturo L.↗

On The Processing of Log Files for Monitoring Antenna Health

In order to improve the quality of geodetic results, we have developed an infrastructure for timely processing of telemetry from IVS observing stations. We check every hour for new log files with telemetry from both VLBI observing sessions, single dish experiments, and stow-in data collection and automatically process them. The telemetry data we use is the system temperature, phase calibration phases and amplitudes, system equivalent flux density, and the differences between formatter clock and GPS clock. For the system temperature and phase calibration, processing includes filtering out outliers and computing averages and rms of the scatter in each scan. Furthermore, for the phase calibration we also compute the group delay and detect spurious signals. Cleaned and post-processed telemetry is archived. Our process detects abnormalities, such as, anomalously high system temperature, unstable phase calibration phases, jumps in the GPS and formatter clock differences, and others. With our procedure, the latency of detection of station abnormalities is reduced to less than two hours. Early detection of abnormalities reduces the amount of affected data since station personnel get early alerts. We discuss our experience of running this system since 2022.

Phase Calibration↗

On The Processing of Log Files for Monitoring Antenna Health

In order to improve the quality of geodetic results, we have developed an infrastructure for timely processing of telemetry from IVS observing stations. We check every hour for new log files with telemetry from both VLBI observing sessions, single dish experiments, and stow-in data collection and automatically process them. The telemetry data we use is the system temperature, phase calibration phases and amplitudes, system equivalent flux density, and the differences between formatter clock and GPS clock. For the system temperature and phase calibration, processing includes filtering out outliers and computing averages and rms of the scatter in each scan. Furthermore, for the phase calibration we also compute the group delay and detect spurious signals. Cleaned and post-processed telemetry is archived. Our process detects abnormalities, such as, anomalously high system temperature, unstable phase calibration phases, jumps in the GPS and formatter clock differences, and others. With our procedure, the latency of detection of station abnormalities is reduced to less than two hours. Early detection of abnormalities reduces the amount of affected data since station personnel get early alerts. We discuss our experience of running this system since 2022.

VLBI↗

F and Cl detection limits in secondary ion mass spectrometry measurements of Si and SiO{sub 2} samples

Usually, F and Cl negative secondary ion currents forming background signals determine detection limits for these elements in secondary ion mass spectrometry (SIMS) measurements. Technique involving changing the primary-ion current was used to determine that the ''memory effect'' is the main source of the background signal for these elements. It is shown that energy distributions of F and Cl ions forming background signals are distinctly narrower than energy distributions of these ions reflecting element bulk concentration in a Si wafer. Using this fact, the F and Cl detection limits in Si were improved by energy filtering of secondary ions. For experimental conditions used, the filtering of the secondary ion energy in a region around 60-70 eV improves the F and Cl detection limits by a factor of more than 6. The effect of an electron beam used for charge neutralization of insulator samples in a negative SIMS mode on the F and Cl detection limits was also investigated. It is shown that the simultaneous use of the primary ion and electron beams causes a synergistic increase of the background signals. It was determined that both F and Cl detection limits for the SiO{sub 2} sample are almost the same as for the Si sample when the electron and ion beams are applied simultaneously. The possible mechanism of this effect is discussed.

36 MATERIALS SCIENCE↗

TH-CD-201-06: Experimental Characterization of Acoustic Signals Generated in Water Following Clinical Photon and Electron Beam Irradiation

Purpose: Previous work has demonstrated the detectability of acoustic waves induced following the irradiation of high density metals with radiotherapy linac photon beams. This work demonstrates the ability to experimentally detect such acoustic signals following both photon and electron irradiation in a more radiotherapy relevant material. The relationship between induced acoustic signal properties in water and the deposited dose distribution is explored, and the feasibility of exploiting such signals for radiotherapy dosimetry is demonstrated. Methods: Acoustic waves were experimentally induced in a water tank via the thermoacoustic effect following a single pulse of photon or electron irradiation produced by a clinical linac. An immersion ultrasound transducer was used to detect these acoustic waves in water and signals were read out on an oscilloscope. Results: Peaks and troughs in the detected acoustic signals were found to correspond to the location of gradients in the deposited dose distribution following both photon and electron irradiation. Signal amplitude was linearly related to the dose per pulse deposited by photon or electron beams at the depth of detection. Flattening filter free beams induced large acoustic signals, and signal amplitude decreased with depth after the depth of maximum dose. Varying the field size resulted in a temporal shift of the acoustic signal peaks and a change in the detected signal frequency. Conclusion: Acoustic waves can be detected in a water tank following irradiation by linac photon and electron beams with basic electronics, and have characteristics related to the deposited dose distribution. The physical location of dose gradients and the amount of dose deposited can be inferred from the location and magnitude of acoustic signal peaks. Thus, the detection of induced acoustic waves could be applied to photon and electron water tank and in vivo dosimetry. This work was supported in part by CIHR grants MOP-114910 and MOP-136774. S.H. acknowledges support by the NSERC CREATE Medical Physics Research Training Network grant 432290.

60 APPLIED LIFE SCIENCES↗

Precision Kinematic Sunyaev--Zel'dovich Measurements Across Halo Mass and Redshift with DESI DR2 and ACT DR6: Part I. Luminous Red Galaxies

We present the most precise measurements of the kinetic Sunyaev-Zel'dovich (kSZ) effect around luminous red galaxies to date, detecting the signal at $18σ$ significance in both harmonic and configuration space. Our analysis cross-correlates 2.4 million spectroscopic LRGs from the Dark Energy Spectroscopic Instrument (DESI) DR2 sample with Data Release 6 (DR6) of the Atacama Cosmology Telescope (ACT). We develop a novel harmonic-space cross-correlation approach using momentum-weighted kSZ templates, yielding nearly uncorrelated bandpowers within a framework consistent with other large-scale structure analyses. By incorporating the LRG halo occupation distribution (HOD) and its uncertainty, we convert measured galaxy gas profiles into halo gas profiles and provide generalized Navarro-Frenk-White (GNFW) fitting profiles, providing empirical targets for tuning feedback efficiency in hydrodynamical simulations and for baryonic modeling in large-scale structure analyses. We find strong evidence that gas profiles do not trace dark matter, providing direct evidence for gas redistribution beyond gravitational collapse. Comparing to hydrodynamical simulations, our measurements favor feedback efficiencies exceeding those in the Battaglia profile, suggesting more efficient gas ejection in group-scale halos than previously predicted. Splitting by redshift, we detect the kSZ signal at SNR $\approx 5$--$10$ in each of four bins and find amplitude evolution consistent with the expected decline in mean halo mass at fixed comoving number density. Splitting by stellar mass, we study the scaling of kSZ amplitude with galaxy properties. Together with BGS and ELG measurements in Paper II, these results span $0.1 \lesssim z \lesssim 1.6$ across three galaxy populations, demonstrating the potential of spectroscopic kSZ to map circumgalactic gas and constrain baryonic feedback.

Qu, F. J. [KIPAC, Menlo Park; Stanford U., HEPL; S↗