Search NASA⌕ Search

SEARCH · Search NASA

Results for “Space Simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Simultaneous thermal vacuum testing of GPS drives for NavStar

The solar array drive assemblies for the global positioning satellite (GPS) were built and the need to perform thermal vacuum acceptance testing on at least two complete units simultaneously is emphasized. The safety of the flight hardware is of primary importance. It is found that simultaneous space simulation testing of two complete drive packages requires only minor modification to the high vacuum pump stack. Attention is given to upgrading system safeties for high vacuum operation. Major modifications are designed and implemented for the thermal control system and supporting subsystems. The automated thermal control system and test bed hardware are of primary interest.

Brown, T. G.↗

Standardization in software conversion of (ROM) estimating

Technical problems and their solutions comprise by far the majority of work involved in space simulation engineering. Fixed price contracts with schedule award fees are becoming more and more prevalent. Accurate estimation of these jobs is critical to maintain costs within limits and to predict realistic contract schedule dates. Computerized estimating may hold the answer to these new problems, though up to now computerized estimating has been complex, expensive, and geared to the business world, not to technical people. The objective of this effort was to provide a simple program on a desk top computer capable of providing a Rough Order of Magnitude (ROM) estimate in a short time. This program is not intended to provide a highly detailed breakdown of costs to a customer, but to provide a number which can be used as a rough estimate on short notice. With more debugging and fine tuning, a more detailed estimate can be made.

Roat, G. H.↗

Fatigue induced cracking in aluminum LN-2 shroud of 39 foot vacuum chamber

Fourteen years after completion of Ford's 39-foot space simulation chamber, leaks began to appear in its LN2 shroud. Although the shroud had been tight since its acceptance, cracks appeared in 1983 in some of the field welds of the one inch tubes which interconnect the LN2 panels. The resulting leaks were large enough to prevent pump down to high vacuum and could be heard easily when the chamber was at ambient conditions. New cracks appeared during each thermal cycle making it impossible to utilize the chamber for thermal vacuum testing. The analysis presented here implies that many, if not all, of the aluminum LN2 shrouds now in use may be in various stages of fatigue failure. The probability is high that fatigue cracks are working through the aluminum tubing in heat-affected zones of some field welds. The cracks may not be apparent yet, but after the shroud has experienced a certain number of thermal cycles these cracks will work through the material and become serious leaks. Fortunately, appropriate planning, analysis, and checking can, with a relatively small expenditure of money, help to avoid large and unexpected shroud failures and keep the chamber operational as long as it is needed.

Edwards, A. A.↗

Wave emissions from dc and modulated electron beams on STS 3

During the third Space Shuttle Columbia flight (STS 3) in March 1982, investigations were conducted to assess the electrical, electromagnetic, and plasma environment of the orbiter and to diagnose wave emissions and related plasma effects due to the injection of an electron beam into the surrounding ionosphere. Attention is given to wave emissions and related plasma processes which were stimulated by the first electron beam emissions from the Space Shuttle. The on-orbit measurements are compared to measurements made in a space simulation chamber. Instrumentation and operations are considered along with the plasma effects of beam emissions, wave emissions from dc beams, wave emissions from VLF-modulated beams, and wave emissions from ELF-modulated beams.

Shawhan, S. D.↗

Evaluation and prediction of long-term environmental effects of nonmetallic materials

The properties of a number of nonmetallic materials were evaluated experimentally in simulated space environments in order to develop models for accelerated test methods useful for predicting such behavioral changes. Graphite-epoxy composites were exposed to thermal cycling. Adhesive foam tapes were subjected to a vacuum environment. Metal-matrix composites were tested for baseline data. Predictive modeling designed to include strength and aging effects on composites, polymeric films, and metals under such space conditions (including the atomic oxygen environment) is discussed. The Korel 8031-00 high strength adhesive foam tape was shown to be superior to the other two tested.

Papazian, H.↗

Cardiovascular Effects of Weightlessness

Physiological changes resulting from long term weightlessness are reviewed and activities conducted to study cardiovascular deconditioning at NASA Ames are discussed. Emphasis is on using monkeys in chair rest, water immersion, and tilt table studies to simulate space environment effects.

Short, K.↗

Effects of high energy radiation on the mechanical properties of epoxy-graphite fiber reinforced composites

In an effort to elucidate the changes in molecular structural and mechanical properties of epoxy/graphite fiber composites upon exposure to ionizing radiation in a simulated space environment, spectroscopic and surface properties of tetraglycidyl-4,4'-diamino diphenyl methane (TGDDM) red with diamino diphenyl sulfone (DDS) and T-300 graphite fiber were investigated following exposure to ionizing radiation. Cobalt-60 gamma radiation and 1/2 MeV electrons were used as radiation sources. The system was studied using electron spin resonance (ESR) spectroscopy, infrared absorption spectroscopy, contact angle measurements, and electron spectroscopy for chemical analysis.

Fornes, R. E.↗

Oxidation and emittance of superalloys in heat shield applications

Recently developed superalloys that form alumina coatings have a high potential for heat shield applications for advanced aerospace vehicles at temperatures above 1095C. Both INCOLOY alloy MA 956 (of the Inco Alloys International, Inc.), an iron-base oxide-dispersion-strengthened alloy, and CABOT alloy No. 214 (of the Cabot Corporation), an alumina-forming nickel-chromium alloy, have good oxidation resistance and good elevated temperature strength. The oxidation resistance of both alloys has been attributed to the formation of a thin alumina layer (alpha-Al2O3) at the surface. Emittance and oxidation data were obtained for simulated Space Shuttle reentry conditions using a hypersonic arc-heated wind tunnel. The surface oxides and substrate alloys were characterized using X-ray diffraction and scanning and transmission electron microscopy with an energy-dispersive X-ray analysis unit. The mass loss and emittance characteristics of the two alloys are discussed.

Wiedemann, K. E.↗

Oxidation and embrittlement of Ti-6Al-2Sn-4Zr-2Mo alloy

A thermogravimetric analysis monitoring study has been conducted for Ti-6Al-2Sn-4Zr-2Mo in the 593-760 C range, with a view to its total oxidation kinetics in laboratory air. In addition, tensile elongation was obtained for selected foil specimens after their exposure to simulated Space Shuttle reentry conditions. The total weight gain with time exhibited two parabolic stages separated by a transient region which is the result of a simultaneous increase in the parabolic growth rate constant for the oxide and in oxygen solubility at the oxide-metal interface. A model for the total oxidation kinetics accounting for the two individual components (oxide growth and solid solution formation) is proposed; the activation energy for oxygen diffusion in the alpha-solid solution is shown to approximate the activation energy for the degradation of tensile elongation of the alloy in its foil gage condition.

Shenoy, R. N.↗

Plasma contactors for electrodynamic tether

The role plasma contactors play in effective electrodynamic tether operation is discussed. Hollow cathodes and hollow cathode-based plasma sources have been identified as leading candidates for the electrodynamic tether plasma contactor. Present experimental efforts to evaluate the suitability of these devices as plasma contactors, conducted concurrently at NASA Lewis Research Center and Colorado State University, are reviewed. These research programs include the definition of preliminary plasma contactor designs, and the characterization of their operation both as electron emitters and electron collectors to and from a simulated space plasma. Results indicate that ampere-level electron currents, sufficient for electrodynamic tether operation, can be exchanged between hollow cathode-based plasma contactors and a dilute plasma.

Patterson, Michael J.↗

Hollow cathode-based plasma contactor experiments for electrodynamic tether

The role plasma contactors play in effective electrodynamic tether operation is discussed. Hollow cathodes and hollow cathode-based plasma sources have been identified as leading candidates for the electrodynamic tether plasma contactor. Present experimental efforts to evaluate the suitability of these devices as plasma contactors are reviewed. This research includes the definition of preliminary plasma contactor designs, and the characterization of their operation as electron collectors from a simulated space plasma. The discovery of an 'ignited mode' regime of high contactor efficiency and low impedance is discussed, as well as is the application of recent models of the plasma coupling process to contactor operation. Results indicate that ampere-level electron currents can be exchanged between hollow cathode-based plasma contactors and a dilute plasma in this regime. A discussion of design considerations for plasma contactors is given which includes expressions defining the total mass flow rate and power requirements of plasma contactors operating in both the cathodic and anodic regimes, and correlation of this to the tether current. Finally, future ground and spaceflight experiments are proposed to resolve critical issues of plasma contactor operation.

Patterson, Michael J.↗

An approach to multivariable control of manipulators

The paper presents simple schemes for multivariable control of multiple-joint robot manipulators in joint and Cartesian coordinates. The joint control scheme consists of two independent multivariable feedforward and feedback controllers. The feedforward controller is the minimal inverse of the linearized model of robot dynamics and contains only proportional-double-derivative (PD2) terms - implying feedforward from the desired position, velocity and acceleration. This controller ensures that the manipulator joint angles track any reference trajectories. The feedback controller is of proportional-integral-derivative (PID) type and is designed to achieve pole placement. This controller reduces any initial tracking error to zero as desired and also ensures that robust steady-state tracking of step-plus-exponential trajectories is achieved by the joint angles. Simple and explicit expressions of computation of the feedforward and feedback gains are obtained based on the linearized model of robot dynamics. This leads to computationally efficient schemes for either on-line gain computation or off-line gain scheduling to account for variations in the linearized robot model due to changes in the operating point. The joint control scheme is extended to direct control of the end-effector motion in Cartesian space. Simulation results are given for illustration.

Seraji, H.↗

Vacuum pumps and systems: A review of current practice

A review of the fundamental characteristics of the many types of vacuum pumps and vacuum pumping systems is given. The optimum pumping range, relative cost, performance limitations, maintenance problems, system operating costs and similar subjects are discussed. Experiences from the thin film deposition, chemical processing, material handling, food processing and other industries, as well as space simulation are used to support conclusions and recommendations.

Giles, Stuart↗

Radiation and temperature effects on the time-dependent response of T300/934 graphite/epoxy

A time-dependent characterization study was performed on T300/934 graphite/epoxy in a simulated space environment. Creep tests on irradiated and nonirradiated graphite/epoxy and bulk resin specimens were carried out at temperatures of 72 and 250 F. Irradiated specimens were exposed to dosages of penetrating electron radiation equal to 30 years exposure at GEO-synchronous orbit. Radiation was shown to have little effect on the creep response of both the composite and bulk resin specimens at 72 F while radiation had a significant effect at 250 F. A healing process was shown to be present in the irradiated specimens where broken bonds in the epoxy due to radiation recombined over time to form cross-links in the 934 resin structure. An analytical micromechanical model was also developed to predict the viscoelastic response of fiber reinforced composite materials. The model was shown to correlate well with experimental results for linearly viscoelastic materials with relatively small creep strains.

Yancey, Robert N.↗

Electrically conductive, black thermal control coatings for spacecraft applications. III - Plasma-deposited ceramic matrix

Five black, electrically-conductive thermal control coatings have been formulated and tested for application on the Galileo spacecraft. The coatings consist of both organic and inorganic systems applied on titanium, aluminum, and glass/epoxy composite surfaces. The coatings were tested under simulated space environment conditions. Coated specimens were subjected to thermal radiation, convective and combustive heating, and cryogenic conditions over a temperature range between -196 C and 538 C. Mechanical, physical, thermal, electrical, and thermooptical properties are presented for one of these coatings. This paper describes the preparation, characteristics, and spraying of iron titanate on titanium and aluminum, and presents performance results.

Hribar, V. F.↗

Plasma contactor design for electrodynamic tether applications

The plasma contacting process is described and experiments are discussed that suggest the key role that cold ions play in establishing a low impedance plasma bridge that can conduct current in either direction between a contactor electrode and a dilute plasma. A ring cusp contactor is shown to provide from 1000-mA of electron emission to 500-mA of electron collection as its bias relative to a simulated space plasma is varied through an 80-v range.

Wilbur, Paul J.↗

IRIS thermal balance test within ESTEC LSS

The Italian Research Interim Stage (IRIS) thermal balance test was successfully performed in the ESTEC Large Space Simulator (LSS) to qualify the thermal design and to validate the thermal mathematical model. Characteristics of the test were the complexity of the set-up required to simulate the Shuttle cargo bay and allowing IRIS mechanism actioning and operation for the first time in the new LSS facility. Details of the test are presented, and test results for IRIS and the LSS facility are described.

Messidoro, Piero↗

Cost effective alternative to low irradiance measurements

Martin Marietta's Space Simulation Laboratory (SSL) has a Thermal Environment Simulator (TES) with 56 individually controlled heater zones. The TES has a temperature range of approximately minus 129 C to plus 149 C. Because of the ability of TES to provide complex irradiance distributions, it is necessary to be able to measure a wide range of irradiance levels. SSL currently uses ambient temperature controlled radiometers with the capacity to measure sink irradiance levels of approximately 42.6 mw/sq cm, sink temperature equals 21 C and up. These radiometers could not be used to accurately measure the lower irradiance levels of the TES. Therefore, it was necessary to obtain a radiometer or develop techniques which could be used to measure lower irradiance levels.

Oleary, Scott T.↗