Search NASA⌕ Search

SEARCH · Search NASA

Results for “System Operator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Hierarchical Engine for Large-scale Infrastructure Co-Simulation

HELICS is designed to support very-large-scale (100,000+ federates) cosimulations with off-the-shelf power-system, communication, market, and end-use tools. Other key features include cross platform operating system support, the integration of both event driven (e.g., packetized communication) and time-series (e.g., power flow) simulations, and the ability to co-iterate among federates to ensure physical model convergence at each time step.

Source record↗

Design of the HELICS High-Performance Transmission-Distribution-Communication-Market Co-Simulation Framework: Preprint

This paper describes the design rationale for a new cyber-physical-energy co-simulation framework for electric power systems. This new framework will support very large-scale (100,000+ federates) co-simulations with off-the-shelf power-systems, communication, and end-use models. Other key features include cross-platform operating system support, integration of both event-driven (e.g. packetized communication) and time-series (e.g. power flow) simulation, and the ability to co-iterate among federates to ensure model convergence at each time step. After describing requirements, we begin by evaluating existing co-simulation frameworks, including HLA and FMI, and conclude that none provide the required features. Then we describe the design for the new layered co-simulation architecture.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hiearchical Engine for Large Scale Infrastructure Simulation

HELICS ls a new open-source, cyber-physlcal-energy co-simulation framework for electric power systems. HELICS Is designed to support very-large-scale (100,000+ federates) co­simulations with off-the-shelf power-system, communication, market, and end-use tools. Other key features Include cross platform operating system support, the integration of both eventdrlven (e.g., packetlzed communication) and time-series (e.g.,power flow) simulations, and the ability to co-Iterate among federates to ensure physical model convergence at each time step.

Top, Philip↗

Situational Awareness of Grid Anomalies (SAGA)

The modern power industry becomes more vulnerable to cyber events due to the growing interconnectivity, interdependence, and complexity of the electric power grid. High-fidelity modeling and simulation tools that support the preventative risk analysis on potential cyber-relevant events is essential for ensuring the situational awareness of the system operator as it provides an inexpensive and risk-free environment to test the system responses under various cyber-relevant events and hereby can support research on cyber anomaly detection, optimal protective resource allocation, and mitigation measures. In this webinar, we will share NREL's cybersecurity research capabilities by highlighting the development of a scalable cyber-physical event test bed and demonstration with real hardware in the loop. The developed cyber-physical event test bed is backboned by an integrated transmission, distribution, and communication dynamic co-simulation framework and a plug-and-play cyber event generation module. It is designed to be modular and compatible with parallel computing, and thereby supports large-scale system simulations at an affordable computation cost. The test bed can capture millisecond-to-minutes dynamic frequency and voltage responses under cyber events from the bulk transmission system to the active distribution systems and distributed energy resources at the grid edge.

co-simulation↗

Smart Grid Integrity Attacks: Characterizations and Countermeasures

Real power injections at loads and generators, and real power flows on selected lines in a transmission network are monitored, transmitted over a SCADA network to the system operator, and used in state estimation algorithms to make dispatch, re-balance and other energy management system [EMS] decisions. Coordinated cyber attacks of power meter readings can be arranged to be undetectable by any bad data detection algorithm. These unobservable attacks present a serious threat to grid operations. Of particular interest are sparse attacks that involve the compromise of a modest number of meter readings. An efficient algorithm to find all unobservable attacks [under standard DC load flow approximations] involving the compromise of exactly two power injection meters and an arbitrary number of power meters on lines is presented. This requires O(n2m) flops for a power system with n buses and m line meters. If all lines are metered, there exist canonical forms that characterize all 3, 4, and 5-sparse unobservable attacks. These can be quickly detected in power systems using standard graph algorithms. Known secure phase measurement units [PMUs] can be used as countermeasures against an arbitrary collection of cyber attacks. Finding the minimum number of necessary PMUs is NP-hard. It is shown that p + 1 PMUs at carefully chosen buses are sufficient to neutralize a collection of p cyber attacks.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Radiation Mapping and Quantification using an Unmanned Ground Vehicle. Part II - Autonomous Navigation

Nuclear sites across the Unites States and other nations in the world, are prone to extreme radiation effects. To understand the radiation hazards, plan the cleanup efforts; and to meet the quality standards and guidelines, it is important to accurately characterize any nuclear facility. One of the current methods in characterizing facilities is the use of advanced autonomous systems. These are safe, efficient, and cost-effective tools, which can safely deploy state-of-the-art instrumentation without exposing workers to radiation risks. Conventional methods of taking radiation measurements by hand within or around the containment areas, and analyzing the collected data to obtain the result are: Ineffective, Puts scientists at risk of Radiation, Not cost-effective. The platform uses the Robotic Operating Systems (ROS) to integrate multiple sensors seamlessly. It can operate near real time by using a distributed processing system to handle large amounts of data: Surrounding cameras, A multi-channel 3D Lidar, Manipulator arm, High-performance gamma-ray spectrometer.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Foundations for the Future Power System: Inverter-Based Resource Interconnection Standards

As power systems evolve to become reliant on solar, wind, batteries, and other inverter-based resources (IBRs), it is essential that those resources meet certain minimum performance and capability criteria designed to ensure the power system operates stably and reliably. Because those criteria, as enshrined in interconnection standards, take years to develop and are very long lived, they need to account for not only the present state of the power system but also its expected future state over the lifetime of the power plants to which they will apply. In addition, they need to be specific enough to ensure reliability without over specifying and, thereby, impeding innovation. Because power systems are shifting rapidly from a state where IBRs make up a small to medium portion of generation to one where the generation will, at times, come predominantly from IBRs, interconnection standards are especially challenging to develop today. Good interconnection standards can make the power system more reliable and less costly to operate, whereas poorly designed standards can lead to major problems, like the famous German 50.2-Hz problem, which introduced a risk of losing many gigawatts of solar on a frequency excursion and resulted in many IBRs being retrofitted at great cost to mitigate a major system reliability risk. Readying the power system by specifying forward-looking technical minimum functional capabilities for IBRs can be an effective approach to avoid future retrofits.

data models↗

Precursor Analysis Report: Industroyer2 and Wiper Malware Targeting Ukrainian Energy Provider 2022

The Industroyer2 and Wiper Malware Targeting Ukrainian Energy Provider 2022 Precursor Analysis Report leverages publicly available information about the Industroyer2 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. An adversary attempted to cause a blackout in Ukraine in April 2022 by using the Industroyer2 malware against a regional Ukrainian energy provider. The adversary targeted eight high-voltage electrical substations and utilized the malware in tandem with disk wipers for Windows, Linux, and Solaris operating systems in an attempt to make response and recovery efforts more difficult. The adversary reused a piece of the original Industroyer malware designed to open circuit breakers and de-energize target substations. The adversary gained initial access to the victim’s enterprise network through unknown means in February 2022 and was able to perform reconnaissance, pivot to the operations network, and reside in the system for at least 51 days. This gave the adversary a detailed understanding of the environment and allowed them to customize the Industroyer2 malware to the victim’s operations network. However, defenders detected and stopped the attack before the adversary could achieve their intended impact. Had the Industroyer2 attack been successful, it could have caused a blackout for more than two million people during the early stages of Russia’s invasion of Ukraine. Researchers and analysts identified 22 unique techniques (used in a sequence of 31 steps) utilized during the attack with a total of 297 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Twenty-three of the identified techniques used during the Industroyer2 cyber attack were precursors to the triggering event. Analysis identified 224 observables associated with these precursor techniques, 122 of which were assessed to have an increased likelihood of being perceived in the 51 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Impact of High Penetration Distributed Energy Resources on the Bulk Electric System

The growth of distributed energy resources (DERs), mostly generation using intermittent renewable energy sources, along with the retirement of central generation (mostly conventional power plants using fossil-fuel-based resources) has implications for the steady-state and dynamic performance of the bulk electric system (BES). Among the DERs connected to the distribution system, photovoltaic (PV) systems are the most prevalent and have been installed at an increasing rate. Until recently, the penetration levels of DERs have not been high enough to create significant impacts on the reliability and security of power system operation. However, in recent years, the penetration levels of DERs have risen to a level that their impacts on the bulk electric system should be considered in a detailed fashion in planning and operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Thermosyphon Cooler Hybrid System for Water Savings in an Energy-Efficient HPC Data Center: Modeling and Installation: Preprint

The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device, the thermosyphon cooler (TSC), with an open cooling tower. A combination of equipment and controls, this new heat rejection system embraces the 'smart use of water,' using evaporative cooling when it is most advantageous and then saving water and modulating toward increased dry sensible cooling as system operations and ambient weather conditions permit. Innovative fan control strategies ensure the most economical balance between water savings and parasitic fan energy. The unique low-pressure-drop design of the TSC allows water to be cooled directly by the TSC evaporator without risk of bursting tubes in subfreezing ambient conditions. Johnson Controls partnered with the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories to deploy the TSC as a test bed at NREL's high-performance computing (HPC) data center in the first half of 2016. Located in NREL's Energy Systems Integration Facility (ESIF), this HPC data center has achieved an annualized average power usage effectiveness rating of 1.06 or better since 2012. Warm-water liquid cooling is used to capture heat generated by computer systems direct to water; that waste heat is either reused as the primary heat source in the ESIF building or rejected using evaporative cooling. This data center is the single largest source of water and power demand on the NREL campus, using about 7,600 m3 (2.0 million gal) of water during the past year with an hourly average IT load of nearly 1 MW (3.4 million Btu/h) -- so dramatically reducing water use while continuing efficient data center operations is of significant interest. Because Sandia's climate is similar to NREL's, this new heat rejection system being deployed at NREL has gained interest at Sandia. Sandia's data centers utilize an hourly average of 8.5 MW (29 million Btu/h) and are also one of the largest consumers of water on Sandia's site. In addition to describing the installation of the TSC and its integration into the ESIF, this paper focuses on the full heat rejection system simulation program used for hourly analysis of the energy and water consumption of the complete system under varying operating scenarios. A follow-up paper will detail the test results. The evaluation of the TSC's performance at NREL will also determine a path forward at Sandia for possible deployment in a large-scale system not only for data center use but also possibly site wide.

97 MATHEMATICS AND COMPUTING↗

Instrumentation status of the low-b magnet systems at the Large Hadron Collider (LHC)

The low-{beta} magnet systems are located in the Large Hadron Collider (LHC) insertion regions around the four interaction points. They are the key elements in the beams focusing/defocusing process allowing proton collisions at luminosity up to 10{sup 34}cm{sup -2}s{sup -1}. Those systems are a contribution of the US-LHC Accelerator project. The systems are mainly composed of the quadrupole magnets (triplets), the separation dipoles and their respective electrical feed-boxes (DFBX). The low-{beta} magnet systems operate in an environment of extreme radiation, high gradient magnetic field and high heat load to the cryogenic system due to the beam dynamic effect. Due to the severe environment, the robustness of the diagnostics is primordial for the operation of the triplets. The hardware commissioning phase of the LHC was completed in February 2010. In the sake of a safer and more user-friendly operation, several consolidations and instrumentation modifications were implemented during this commissioning phase. This paper presents the instrumentation used to optimize the engineering process and operation of the final focusing/defocusing quadrupole magnets for the first years of operation.

43 PARTICLE ACCELERATORS↗

LCOE reduction through proactively optimized monitoring of PV Systems (Final Technical Report)

The project demonstrates the value proposition for a high-resolution monitoring system (HRMS) with diagnostic-prognostic capability and determine its impact on LCOE. The HRMS differs from conventional monitoring systems in a number of ways. First it will include the capability to automatically measure IV curves at the string and module levels. This provides a much richer view into the DC performance of the PV system and allows classification of many typical failure and degradation modes. Second, it will incorporate software capable of quantifying power and energy losses in the field as well as define the location and mechanism of the power and energy loss. Moreover, we aimed to deliver a prognostic system that is capable of predicting certain failures before they occur and giving system operators the opportunity to more efficiently plan operations and maintenance (O&M) activity in order to lower costs and increase yield over the life of the system. The research identifies cost targets required for different monitoring stages, including at the string combiner, at the individual string, and at the module level, to lower the levelized cost of energy (LCOE). Finally, a comprehensive guide determines the value PV monitoring brings to PV field operations. The guide assists plant operators in maximizing value from existing plants and identify the trade-offs of different monitoring solutions for future plants depending on the size, location, and expected system lifetime.

14 SOLAR ENERGY↗

Self-Organizing Map-Based Resilience Quantification and Resilient Control of Distribution Systems Under Extreme Events

Due to climate change, extreme weather events are occurring more frequently and with increasing impact. This trend poses a significant challenge for distribution system operators (DSO) to ensure that there is uninterrupted power supply to critical loads in their networks. To embed resilience into DSO's decision-making, resilience needs to be first quantified and then integrated into the system-level optimization. Therefore, this paper first develops a novel self-organizing map (SOM) based method (called SomRes) to quantify the time-varying resilience index of a system that can leverage the powerful classification property of SOMs and removes some of the disadvantages of subjective weight assignment methods. Using SomRes, a resilient resource allocation and operational dispatch algorithm is further developed to enhance system resilience against extreme events by considering the SomRes resilience index directly as the feedback. Here, the proposed resilience quantification approach is benchmarked with a state-of-the-art approach and the efficacy of the proposed resilient dispatch algorithm is demonstrated through several deterministic and statistical case studies on the IEEE 123-bus distribution system. Simulation studies show that the proposed SomRes quantification method is an appropriate indicator of system resilience, and the resilient resource allocation and dispatch strategy can significantly reduce critical load shedding under varying event propagation scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Joint Seasonal ARMA Approach for Modeling of Load Forecast Errors in Planning Studies

To make informed and robust decisions in the probabilistic power system operation and planning process, it is critical to conduct multiple simulations of the generated combinations of wind and load parameters and their forecast errors to handle the variability and uncertainty of these time series. In order for the simulation results to be trustworthy, the simulated series must preserve the salient statistical characteristics of the real series. In this paper, we analyze day-ahead load forecast error data from multiple balancing authority locations and characterize statistical properties such as mean, standard deviation, autocorrelation, correlation between series, time-of-day bias, and time-of-day autocorrelation. We then construct and validate a seasonal autoregressive moving average (ARMA) model to model these characteristics, and use the model to jointly simulate day-ahead load forecast error series for all BAs.

Power system planning, Operations, Probabilistic m↗

A Decentralized Market Mechanism for Energy Communities under Operating Envelopes

Here, we propose an operating envelopes (OEs) aware energy community market mechanism that dynamically charges/rewards its members based on two-part pricing. The OEs are imposed exogenously by a regulated distribution system operator (DSO) on the energy community's revenue meter and is subject to a generalized net energy metering (NEM) tariff design. By formulating the interaction of the community operator and its members as a Stackelberg game, we show that the proposed two-part pricing achieves a Nash equilibrium and maximizes the community's social welfare in a decentralized fashion while ensuring that the community's operation abides by the OEs. The market mechanism conforms with the cost-causation principle and guarantees community members a surplus level no less than their maximum surplus when they autonomously face the DSO. The dynamic and uniform community price is a monotonically decreasing function of the community's aggregate renewable generation. We also analyze the impact of exogenous parameters such as NEM rates and OEs on the value of joining the community. Lastly, through numerical studies, we showcase the community's welfare, and pricing, and compare its members' surplus to customers under the DSO's regime.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine (Final Report)

As the nation continues to encourage, through market structures and financial incentives, the proliferation of intermittent renewable electricity, how to optimize the ever-changing electric grid and identify means to retain and improve resilience, while ensuring continued reductions in GHG emissions, will be critical. According to Bloomberg, wind & solar generated 10.5% of US electricity in 2020 and that percentage continues to grow. In support of expanding renewable energy use, and to address its intermittent nature, this project will develop the Hydrogen Storage for Flexible Fossil Fuel Power Generation platform that is dispatchable, reliable, repeatable and have the ability to produce zero or negative carbon power while interfacing with geology capable of CO2 and hydrogen storage. GTI Energy (GTIE) and team members Illinois State Geological Survey (ISGS), Mitsubishi Heavy Industries America (MHIA), Ameren Illinois, Hexagon Purus, and the Low Carbon Resources Initiative (LCRI) completed a Phase I Conceptual Study under contract DE-FE0032012 for Hydrogen Storage for Flexible Fossil Fuel Power Generation: Integration of Underground Hydrogen Storage with Gas Turbine. The Hydrogen Storage for Flexible Fossil Fuel Power Generation platform addresses the intermittent nature of the expanding use of Variable Renewable Energy (VRE) generation. The low cost of the electricity (COE) generated results in greater dispatch and more operation at higher power levels (higher efficiency), fewer short intervals, and fewer start/stop cycles. The reliable, resilient system can produce zero carbon power and store hydrogen. It will demonstrate hydrogen storage in geologic formations like those used in natural gas underground storage thus enabling large scale storage of hydrogen in sedimentary strata across the United States rather than in geographically restricted salt caverns. The Phase I study confirmed the system is feasible and generates power at lower cost than other low carbon approaches. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production. The study advanced the maturity of the H 2 storage-based system with flexible power generation by completing a Pre-FEED study (Phase II). The Pre-FEED focused on the selected Energy Farm on the University of Illinois Urbana-Champaign (UIUC) site that includes above ground and underground hydrogen storage, low-carbon hydrogen production (GTI’s Compact Hydrogen Generator, CHG) with underground CO2 sequestration, and a 40-MW class gas turbine. The Pre-FEED addressed the entire system and its interconnection to the natural gas and electric grid and mitigation of key risks, such as storage behavior, load-following, and system operation. During Phase 1 of the project, the team completed key tasks, which moved the entire demonstration project, specific components and approaches closer to commercialization. These Phase I Accomplishments include: Completing System Requirements Review; Completing System Layout and Modeling - Heat & Mass Balance and Process Flow Diagram; Completing modelling of 9 turbine performance cases; Evaluating rock strata for underground storage of hydrogen and sequestration of carbon dioxide; Completing initial modelling of underground storage of hydrogen and withdrawal with evaluation of loss and water production; Identifying roadable storage for above ground hydrogen storage; Identifying existing electrical infrastructure for receiving/delivering electricity; Identifying existing gas supply infrastructure for receiving natural gas; Document concept design/development plans in required reports. Conclusions: The 12-month Feasibility study in Phase I study was completed and confirmed the system is feasible and generates power at lower cost than other low carbon approaches and even lower cost than the reference NGCC plant without carbon capture when taking advantage of 45Q carbon credits. The study enabled the fidelity of the concept to be improved and allowed identification of the requirements for the system. Defining the individual system and component requirements was performed via the system requirements review with the whole team. These requirements were then incorporated into and iterated with our Heat & Mass Balance process model and process flow diagrams were generated to reflect the overall system. This information was then used to complete the TEA and show economic feasibility. Large scale non-salt geologic storage of hydrogen is an enabling technology for a hydrogen-fired turbine that can be retrofitted into large-scale electric generating units (EGU). Our demonstration will include 428 MWh or ~4 hours full load of hydrogen storage (above and underground). Carbon capture inherent to the CHG process can capture 90% CO 2 (with upgrades to >98%). This system provides a COE of 23% savings relative to an NGCC with a post combustion amine system. Our proposed storage system decouples carbon capture and hydrogen production from power production; therefore, we expect our proposed system’s efficiency and variable COE to be superior resulting in overall higher dispatch and reduced deep cycling. Our demonstration will be full to multi-day hydrogen storage and has the potential for longer (seasonal) duration commercially. The demonstration defines the pathway for broad commercial application and will accelerate the development of larger systems suitable for centralized utility scale electricity production.

03 NATURAL GAS↗

Assessment of transport performance index for urban transport development strategies — Incorporating residents' preferences

The performance of urban transport depends on a variety of factors related to metropolitan structure; in particular, the patterns of commuting, roads and public transport (PT) systems. To evaluate urban transport planning efforts, there is a need for a metric expressing the aggregate performance of the city's transport systems which should relate to residents' preferences. The existing metrics have typically focused on a measure to express the proximity of job locations to residences. A Transport Performance Index (TPI) is proposed in which the total cost of transportation system (operational and environmental costs) is divided by willingness to pay (WTP) for transport plus the willingness to accept (WTA) the environmental effects on residents. Transport operational as well as the environmental costs are derived from a simulation of all transport systems, to particular designs of spatial development. Willingness to pay for transport and willingness to accept the environmental effects are derived from surveys among residents. Simulations were modelled of Surabaya's spatial structure and public transport expansion. The results indicate that the current TPI is high, which will double by 2030. With a hypothetical polycentric city structure and adjusted job housing balance, a lower index occurs because of the improvements in urban transport performance. A low index means that the residents obtain much benefit from the alternative proposed. This illustrates the importance of residents' preferences in urban spatial planning in order to achieve efficient urban transport. Applying the index suggests that city authorities should provide fair and equitable public transport systems for suburban residents in the effort to control the phenomenon of urban sprawl. This index is certainly a good tool and prospective benchmark for measuring sustainability in relation to urban development.

54 ENVIRONMENTAL SCIENCES↗