Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

The use of satellite altimetry in the study of weakly defined and variable oceanic gyres

Most of what is known about oceanic gyres comes from studies of the two main Northern Hemisphere subtropical gyres. Also important in the overall circulation of the world's oceans are the Southern Hemisphere subtropical gyres and the cyclonic Alaskan Gyre in the northern Pacific. Due in part to their weaker surface topography signatures and their variable character, these gyres have not been observed and studied as well as the northern subtropical gyres. The combination of satellite altimetry with in situ ocean measurements will lead to improved resolution of the interannual and seasonal change in the circulation of these ocean gyres. Also, it will provide initialization input and verification for numerical modeling work designed to better understand internal gyre dynamics. The objective of this proposal is to combine satellite and in situ data in a study dedicated to a better understanding of the basic structure and dynamics of the weakly defined Southern Hemisphere gyres and the Alaskan Gyre and their roles in oceanic heat and mass transport of the world ocean. Emphasis will be on description of the Alaskan Gyre.

Born, George H.↗

Verification and Validation Process for Progressive Damage and Failure Analysis Methods in the NASA Advanced Composites Consortium

The Advanced Composites Consortium is a US Government/Industry partnership supporting technologies to enable timeline and cost reduction in the development of certified composite aerospace structures. A key component of the consortium's approach is the development and validation of improved progressive damage and failure analysis methods for composite structures. These methods will enable increased use of simulations in design trade studies and detailed design development, and thereby enable more targeted physical test programs to validate designs. To accomplish this goal with confidence, a rigorous verification and validation process was developed. The process was used to evaluate analysis methods and associated implementation requirements to ensure calculation accuracy and to gage predictability for composite failure modes of interest. This paper introduces the verification and validation process developed by the consortium during the Phase I effort of the Advanced Composites Project. Specific structural failure modes of interest are first identified, and a subset of standard composite test articles are proposed to interrogate a progressive damage analysis method's ability to predict each failure mode of interest. Test articles are designed to capture the underlying composite material constitutive response as well as the interaction of failure modes representing typical failure patterns observed in aerospace structures.

Wanthal, Steven↗

Variation in GMC Association Properties across the Bars, Spiral Arms, Inter-arms, and Circumnuclear Region of M100 (NGC 4321) Extracted from ALMA Observations

We study the physical properties of giant molecular cloud associations (GMAs) in M100 (NGC 4321) using the ALMA Science Verification feathered (12 m+ACA) data in {sup 12}CO (1–0). To examine the environmental dependence of their properties, GMAs are classified based on their locations in various environments as circumnuclear ring (CNR), bar, spiral, and inter-arm GMAs. The CNR GMAs are massive and compact, while the inter-arm GMAs are diffuse, with low surface density. GMA mass and size are strongly correlated, as suggested by Larson. However, the diverse power-law index of the relation implies that the GMA properties are not uniform among the environments. The CNR and bar GMAs show higher velocity dispersion than those in other environments. We find little evidence for a correlation between GMA velocity dispersion and size, which indicates that the GMAs are in diverse dynamical states. Indeed, the virial parameter of the GMAs spans nearly two orders of magnitude. Only the spiral GMAs are generally self-gravitating. Star formation activity decreases in order over the CNR, spiral, bar, and inter-arm GMAs. The diverse GMA and star formation properties in different environments lead to variations in the Kennicutt–Schmidt relation. A combination of multiple mechanisms or gas phase change is necessary to explain the observed slopes. Comparisons of GMA properties acquired with the use of the 12 m array observations with those from the feathered data are also presented. The results show that the missing flux and extended emission cannot be neglected for the study of environmental dependence.

79 ASTRONOMY AND ASTROPHYSICS↗

The reduction, verification and interpretation of MAGSAT magnetic data over Canada

Procedures were established to select quiet, least-disturbed MAGSAT data in an effort to study the magnetic field originating in the solid Earth. A preliminary map of scalar field anomalies over Canada and adjacent regions was produced. Data from Fort Churchill magnetic observatory (an auroral zone station) were used in classifying MAGSAT passes as quiet, unsettled, or disturbed. Determinations of long-term quiet levels at Canadian magnetic observatories are being made. For the time interval of each MAGSAT pass, the deviations of the mean hourly values of the magnetic field components are determined from these quiet levels, in particular for Fort Churchill. Primary processing all CHRONINT tapes received to date, involved decoding orbit records, decimating data records, selecting time intervals and latitude intervals, and producing output tapes carrying records with data point time, position and magnetic information. Subsequent processing converts the coordinate system from geocentric to geodetic and removes a reference field.

Coles, R. L.↗

Investigation of Navier-Stokes Code Verification and Design Optimization

With rapid progress made in employing computational techniques for various complex Navier-Stokes fluid flow problems, design optimization problems traditionally based on empirical formulations and experiments are now being addressed with the aid of computational fluid dynamics (CFD). To be able to carry out an effective CFD-based optimization study, it is essential that the uncertainty and appropriate confidence limits of the CFD solutions be quantified over the chosen design space. The present dissertation investigates the issues related to code verification, surrogate model-based optimization and sensitivity evaluation. For Navier-Stokes (NS) CFD code verification a least square extrapolation (LSE) method is assessed. This method projects numerically computed NS solutions from multiple, coarser base grids onto a freer grid and improves solution accuracy by minimizing the residual of the discretized NS equations over the projected grid. In this dissertation, the finite volume (FV) formulation is focused on. The interplay between the xi concepts and the outcome of LSE, and the effects of solution gradients and singularities, nonlinear physics, and coupling of flow variables on the effectiveness of LSE are investigated. A CFD-based design optimization of a single element liquid rocket injector is conducted with surrogate models developed using response surface methodology (RSM) based on CFD solutions. The computational model consists of the NS equations, finite rate chemistry, and the k-6 turbulence closure. With the aid of these surrogate models, sensitivity and trade-off analyses are carried out for the injector design whose geometry (hydrogen flow angle, hydrogen and oxygen flow areas and oxygen post tip thickness) is optimized to attain desirable goals in performance (combustion length) and life/survivability (the maximum temperatures on the oxidizer post tip and injector face and a combustion chamber wall temperature). A preliminary multi-objective optimization study is carried out using a geometric mean approach. Following this, sensitivity analyses with the aid of variance-based non-parametric approach and partial correlation coefficients are conducted using data available from surrogate models of the objectives and the multi-objective optima to identify the contribution of the design variables to the objective variability and to analyze the variability of the design variables and the objectives. In summary the present dissertation offers insight into an improved coarse to fine grid extrapolation technique for Navier-Stokes computations and also suggests tools for a designer to conduct design optimization study and related sensitivity analyses for a given design problem.

Vaidyanathan, Rajkumar↗

Analysis of Harrell Monosodium Titanate Lot #050411

Harrell Industries is under contract with Savannah River Remediation to provide Monosodium titanate (MST) for use in the Actinide Removal Process (ARP). A 500-mL qualification sample for Lot 050411 was sent to the Savannah River National Laboratory (SRNL) to confirm the material meets the requirements specified in the purchase specification. The vendor is also obligated to send verification samples from {approx}10% or more of the pails of MST product for each lot (distributed roughly evenly through the entire lot of pails). For the verification of this lot, Harrell Industries sent 12 samples, one each from pails No.1, 10, 20, 30, 40, 60, 70, 80, 90, 100, 110, and 120 of 120 total pails. MST for use in the Actinide Removal Process (ARP) must be qualified and verified in advance. A single qualification sample for each batch of material is sent to SRNL for analysis, as well as a statistical sampling of verification samples. The Harrell Industries Lot 050411 qualification and 12 verification samples met all the requirements in the specification indicating the material is acceptable for use in the process.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-F-T-619: Dose Evaluation of Specific Patient Plans Based On Monte Carlo Algorithm for a CyberKnife Stereotactic Radiosurgery System

Purpose: This study will use Monte Carlo to simulate the Cyberknife system, and intend to develop the third-party tool to evaluate the dose verification of specific patient plans in TPS. Methods: By simulating the treatment head using the BEAMnrc and DOSXYZnrc software, the comparison between the calculated and measured data will be done to determine the beam parameters. The dose distribution calculated in the Raytracing, Monte Carlo algorithms of TPS (Multiplan Ver4.0.2) and in-house Monte Carlo simulation method for 30 patient plans, which included 10 head, lung and liver cases in each, were analyzed. The γ analysis with the combined 3mm/3% criteria would be introduced to quantitatively evaluate the difference of the accuracy between three algorithms. Results: More than 90% of the global error points were less than 2% for the comparison of the PDD and OAR curves after determining the mean energy and FWHM.The relative ideal Monte Carlo beam model had been established. Based on the quantitative evaluation of dose accuracy for three algorithms, the results of γ analysis shows that the passing rates (84.88±9.67% for head,98.83±1.05% for liver,98.26±1.87% for lung) of PTV in 30 plans between Monte Carlo simulation and TPS Monte Carlo algorithms were good. And the passing rates (95.93±3.12%,99.84±0.33% in each) of PTV in head and liver plans between Monte Carlo simulation and TPS Ray-tracing algorithms were also good. But the difference of DVHs in lung plans between Monte Carlo simulation and Ray-tracing algorithms was obvious, and the passing rate (51.263±38.964%) of γ criteria was not good. It is feasible that Monte Carlo simulation was used for verifying the dose distribution of patient plans. Conclusion: Monte Carlo simulation algorithm developed in the CyberKnife system of this study can be used as a reference tool for the third-party tool, which plays an important role in dose verification of patient plans. This work was supported in part by the grant from Chinese Natural Science Foundation (Grant No. 11275105). Thanks for the support from Accuray Corp.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 33: The Influence of a Modeled Treatment Couch on Dose Distributions During IMRT and RapidArc Treatment Delivery

Treatment couches have been known to perturb dose delivery in patients. This effect is most pronounced in techniques such as IMRT and RapidArc. Although modern treatment planning systems (TPS) include data for a “default” treatment couch, actual couches are not manufactured identically. Thus, variations in their Hounsfield Unit (HU) values may exist. This study demonstrates a practical and simple method of acquiring reliable HU data for any treatment couch. We also investigate the effects of both the default and modeled treatment couches on absorbed dose. Experimental verifications show that by neglecting to incorporate the treatment couch in the TPS, dose differences of up to 9.5% and 7.3% were present for 4 MV and 10 MV photon beams, respectively. Furthermore, a clinical study based on a cohort of 20 RapidArc and IMRT (brain, pelvis and abdominal) cases is performed. 2D dose distributions show that without the couch in the planning phase, differences ≤ 4.6% and 5.9% for RapidArc and IMRT cases are present for the same cases that the default couch was added to. Additionally, in comparison to the default couch, employing the modeled couch in the calculation process influences dose distributions by ≤ 2.7% and 8% for RapidArc and IMRT cases, respectively. This result was found to be site specific; where an accurate couch proves to be preferable for IMRT brain plans. As such, adding the couch during dose calculation decreases dose calculation errors, and a precisely modeled treatment couch offers higher dose delivery accuracy for brain treatment using IMRT.

60 APPLIED LIFE SCIENCES↗

Intelligent Leak Detection System

apability of underground carbon dioxide storage to confine and sustain injected CO2 for a very long time is the main concern for geologic CO2 sequestration. If a leakage from a geological CO2 sequestration site occurs, it is crucial to find the approximate amount and the location of the leak in order to implement proper remediation activity. An overwhelming majority of research and development for storage site monitoring has been concentrated on atmospheric, surface or near surface monitoring of the sequestered CO2. This study aims to monitor the integrity of CO2 storage at the reservoir level. This work proposes developing in-situ CO2 Monitoring and Verification technology based on the implementation of Permanent Down-hole Gauges (PDG) or “Smart Wells” along with Artificial Intelligence and Data Mining (AI&DM). The technology attempts to identify the characteristics of the CO2 leakage by de-convolving the pressure signals collected from Permanent Down-hole Gauges (PDG). Citronelle field, a saline aquifer reservoir, located in the U.S. was considered for this study. A reservoir simulation model for CO2 sequestration in the Citronelle field was developed and history matched. The presence of the PDGs were considered in the reservoir model at the injection well and an observation well. High frequency pressure data from sensors were collected based on different synthetic CO2 leakage scenarios in the model. Due to complexity of the pressure signal behaviors, a Machine Learning-based technology was introduced to build an Intelligent Leakage Detection System (ILDS). The ILDS was able to detect leakage characteristics in a short period of time (less than a day) demonstrating the capability of the system in quantifying leakage characteristics subject to complex rate behaviors. The performance of ILDS was examined under different conditions such as multiple well leakages, cap rock leakage, availability of an additional monitoring well, presence of pressure drift and noise in the pressure sensor and uncertainty in the reservoir model.

Mohaghegh, Shahab D.↗

High Dose-Per-Fraction Irradiation of Limited Lung Volumes Using an Image-Guided, Highly Focused Irradiator: Simulating Stereotactic Body Radiotherapy Regimens in a Small-Animal Model

Purpose: To investigate the underlying biology associated with stereotactic body radiotherapy (SBRT), both in vivo models and image-guided, highly focal irradiation systems are necessary. Here, we describe such an irradiation system and use it to examine normal tissue toxicity in a small-animal model at lung volumes similar to those associated with human therapy. Methods and Materials: High-dose radiation was delivered to a small volume of the left lung of C3H/HeJCr mice using a small-animal stereotactic irradiator. The irradiator has a collimation mechanism to produce focal radiation beams, an imaging subsystem consisting of a fluorescent screen coupled to a charge-coupled device camera, and a manual positioning stage. Histopathologic examination and micro-CT were used to evaluate the radiation response. Results: Focal obliteration of the alveoli by fibrous connective tissue, hyperplasia of the bronchiolar epithelium, and presence of a small number of inflammatory cells are the main reactions to low-volume/high-dose irradiation of the mouse lung. The tissue response suggested a radiation dose threshold for early phase fibrosis lying between 40 and 100 Gy. The irradiation system satisfied our requirements of high-dose-rate, small beam diameter, and precise localization and verification. Conclusions: We have established an experimental model and image-guided animal irradiation system for the study of high dose per fraction irradiations such as those used with SBRT at volumes analogous to those used in human beings. It will also allow the targeting of specific anatomical structures of the thorax or ultimately, orthotopic tumors of the lung.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical Application of In-Room Positron Emission Tomography for In Vivo Treatment Monitoring in Proton Radiation Therapy

Purpose: The purpose of this study is to evaluate the potential of using in-room positron emission tomography (PET) for treatment verification in proton therapy and for deriving suitable PET scan times. Methods and Materials: Nine patients undergoing passive scattering proton therapy underwent scanning immediately after treatment with an in-room PET scanner. The scanner was positioned next to the treatment head after treatment. The Monte Carlo (MC) method was used to reproduce PET activities for each patient. To assess the proton beam range uncertainty, we designed a novel concept in which the measured PET activity surface distal to the target at the end of range was compared with MC predictions. The repositioning of patients for the PET scan took, on average, approximately 2 minutes. The PET images were reconstructed considering varying scan times to test the scan time dependency of the method. Results: The measured PET images show overall good spatial correlations with MC predictions. Some discrepancies could be attributed to uncertainties in the local elemental composition and biological washout. For 8 patients treated with a single field, the average range differences between PET measurements and computed tomography (CT) image-based MC results were <5 mm (<3 mm for 6 of 8 patients) and root-mean-square deviations were 4 to 11 mm with PET-CT image co-registration errors of approximately 2 mm. Our results also show that a short-length PET scan of 5 minutes can yield results similar to those of a 20-minute PET scan. Conclusions: Our first clinical trials in 9 patients using an in-room PET system demonstrated its potential for in vivo treatment monitoring in proton therapy. For a quantitative range prediction with arbitrary shape of target volume, we suggest using the distal PET activity surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simulation Study of Toroidal Shear Flow Generation by a Local ICRF Heating

The toroidal shear flow generation by a local ICRF heating is studied using GNET code, in which the drift kinetic equation is solved in 5D phase-space. Verification of the Ohkawa model [T. Ohkawa and Miller, Phys. Plasmas 12(2005) 094506.] predicting the toroidal shear flow generation is done including the finite orbit effect of energetic ions in a tokamak configuration. The Alcator C-mod plasma is assumed as a first step. A co-directional toroidal flow outside of the power absorption region (resonance position) is observed. The dominant part of toroidal flow dose not depend on the sign k{sub ||} and this fact indicates that the driving mechanism of the dominant part is different from that proposed by the Ohkawa model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Anomalous magnetic behavior at the graphene/Co interface

An intensive theoretical study on the interaction between graphene and transition metal atom has been carried out; however, its experimental verification is still lacking. To explore the theoretical prediction of antiferromagnetic coupling due to charge transfer between graphene and cobalt, epitaxial layer of cobalt is grown on graphene surface. Predicted antiferromagnetic interaction with Neel temperature (T{sub N} ∼ 32 K) which anomalously shifts to higher temperature (34 K) and becomes more prominent under application of magnetic field of 1 T is reported. Lowering of magnetoresistance as a consequence of this antiferromagnetic coupling at the interface is also observed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparison of the dose distribution obtained from dosimetric systems with intensity modulated radiotherapy planning system in the treatment of prostate cancer

The aim of this study is to compare Intensity Modulated Radiation Therapy (IMRT) plan of prostate cancer patients with different dose verification systems in dosimetric aspects and to compare these systems with each other in terms of reliability, applicability and application time. Dosimetric control processes of IMRT plan of three prostate cancer patients were carried out using thermoluminescent dosimeter (TLD), ion chamber (IC) and 2D Array detector systems. The difference between the dose values obtained from the dosimetric systems and treatment planning system (TPS) were found to be about % 5. For the measured (TLD) and calculated (TPS) doses %3 percentage differences were obtained for the points close to center while percentage differences increased at the field edges. It was found that TLD and IC measurements will increase the precision and reliability of the results of 2D Array.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparative analysis of numerical models of pipe handling equipment used in offshore drilling applications

Design of offshore drilling equipment is a task that involves not only analysis of strict machine specifications and safety requirements but also consideration of changeable weather conditions and harsh environment. These challenges call for a multidisciplinary approach and make the design process complex. Various modeling software products are currently available to aid design engineers in their effort to test and redesign equipment before it is manufactured. However, given the number of available modeling tools and methods, the choice of the proper modeling methodology becomes not obvious and – in some cases – troublesome. Therefore, we present a comparative analysis of two popular approaches used in modeling and simulation of mechanical systems: multibody and analytical modeling. A gripper arm of the offshore vertical pipe handling machine is selected as a case study for which both models are created. In contrast to some other works, the current paper shows verification of both systems by benchmarking their simulation results against each other. Such criteria as modeling effort and results accuracy are evaluated to assess which modeling strategy is the most suitable given its eventual application.

97 MATHEMATICS AND COMPUTING↗

Laser optical frequency combs and their applications in optical fibre communication systems and astrophysics

This paper examines the generation and applications of laser optical frequency combs (LOFCs). The unique properties of LOFCs are widely used in spectroscopy and metrology, in particular for making ultra-accurate optical clocks. The use of LOFCs contributes to advances in optical fibre communication systems and studies pertaining to fundamental problems of astrophysics, such as the search for and investigation of exoplanets and verification of the hypothesis that physical constants vary with time. (invited paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coupled modeling of wake steering and platform offsets for floating wind arrays

Wake effects are a key challenge in the design and analysis of wind farms. For floating wind farms, the platforms offset under the aerodynamic loading of the turbine and are constrained by mooring systems that can vary significantly in allowable offsets. When considering wake steering, the crosswind offset of the turbine can counteract the lateral deflection of the wake. This work presents a tool to efficiently model the coupled impacts of wake steering and platform offsets for floating wind farms. The tool relies on the frequency-domain wind farm model RAFT and the steady-state wake model FLORIS. A verification with FAST.Farm is presented, then the tool is applied to a simple two-turbine case study. A range of mooring systems with increasing platform offsets and varied yaw misalignment angles are considered while comparing the impact on turbine power. Additional sensitivities to turbine spacing and mooring system orientation are explored. The results show that there is a least-optimal watch circle width for downwind turbine power production that varies with yaw misalignment angle and turbine spacing. Additionally, the turbine offsets under yaw-misaligned conditions vary significantly depending on mooring system orientation relative to the rotor plane, which in turn impacts the optimal misalignment angle. These results highlight the importance of including floating platform offsets and mooring systems in the evaluation of wake steering strategies for floating wind arrays.

17 WIND ENERGY↗