Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Diagnostic evaluations of a beam-shielded 8-cm mercury ion thruster

An engineering model thruster fitted with a remotely actuated graphite fiber polyimide composite beam shield was tested in a 3- by 6.5-meter vacuum facility for in-situ assessment of beam shield effects on thruster performance. Accelerator drain current neutralizer floating potential and ion beam floating potential increased slightly when the shield was moved into position. A target exposed to the low density regions of the ion beam was used to map the boundaries of energetic fringe ions capable of sputtering. The particle efflux was evaluated by measurement of film deposits on cold, heated, bare, and enclosed glass slides.

Nakanishi, S.↗

Diagnostic evaluations of a beam-shielded 8-cm mercury ion thruster

An engineering model thruster fitted with a remotely actuated graphite fiber polyimide composite beam shield was tested in a 3- by 6.5-meter vacuum facility for in-situ assessment of beam shield effects on thruster performance. Accelerator drain current neutralizer floating potential and ion beam floating potential increased slightly when the shield was moved into position. A target exposed to the low density regions of the ion beam was used to map the boundaries of energetic fringe ions capable of sputtering. The particle efflux was evaluated by measurement of film deposits on cold, heated, bare, and enclosed glass slides.

Nakanishi, S.↗

Investigation of mechanism of anode plasma formation in ion diode with dielectric anode

The results of investigation of the anode plasma formation in a diode with a passive anode in magnetic insulation mode are presented. The experiments have been conducted using the BIPPAB-450 ion accelerator (350–400 kV, 6–8 kA, 80 ns) with a focusing conical diode with B{sub r} external magnetic field (a barrel diode). For analysis of plasma formation at the anode and the distribution of the ions beam energy density, infrared imaging diagnostics (spatial resolution of 1–2 mm) is used. For analysis of the ion beam composition, time-of-flight diagnostics (temporal resolution of 1 ns) were used. Our studies have shown that when the magnetic induction in the A-C gap is much larger than the critical value, the ion beam energy density is close to the one-dimensional Child-Langmuir limit on the entire working surface of the diode. Formation of anode plasma takes place only by the flashover of the dielectric anode surface. In this mode, the ion beam consists primarily of singly ionized carbon ions, and the delay of the start of formation of the anode plasma is 10–15 ns. By reducing the magnetic induction in the A-C gap to a value close to the critical one, the ion beam energy density is 3–6 times higher than that calculated by the one-dimensional Child-Langmuir limit, but the energy density of the ion beam is non-uniform in cross-section. In this mode, the anode plasma formation occurs due to ionization of the anode material with accelerated electrons. In this mode, also, the delay in the start of the formation of the anode plasma is much smaller and the degree of ionization of carbon ions is higher. In all modes occurred effective suppression of the electronic component of the total current, and the diode impedance was 20–30 times higher than the values calculated for the mode without magnetic insulation of the electrons. The divergence of the ion beam was 4.5°–6°.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An overview of the new test stand for H{sup −} ion sources at FNAL

A new test stand at Fermi National Accelerator Laboratory (FNAL) is being constructed to carry out experiments to develop and upgrade the present magnetron-type sources of H{sup −} ions of up to 80 mA at 35 keV in the context of the Proton Improvement Plan. The aim of this plan is to provide high-power proton beams for the experiments at FNAL. The technical details of the construction and layout of this test stand are presented, along with a prospective set of diagnostics to monitor the sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

3D Tracking of a Single Electron in IOTA

High-resolution observations of single-particle dynamics have potential as a powerful tool in the diagnostics, tuning and design of storage rings. We are presenting the results of experiments with single electrons that were conducted at Fermilab’s IOTA ring to explore the feasibility of this approach. A set of sensitive, high-resolution digital cameras was used to detect the synchrotron radiation emitted by an electron, and the resulting images were used to reconstruct the time evolution of oscillation amplitudes in all three degrees of freedom. From the evolution of the oscillation amplitudes, we deduce transverse emittances, momentum spread, damping times, beam energy and estimated residual-gas density and composition. To our knowledge, this is the first time that the dynamics of a single particle in a storage ring has been tracked in all three dimensions. We discuss farther development of a single particle diagnostics that may allow reconstruction of its turn-by-turn coordinates over macroscopic periods of time facilitating ultra-precise lattice diagnostics and direct benchmarking of tracking codes.

43 PARTICLE ACCELERATORS↗

First Measurements of the Longitudinal Bunch Profile at SLAC Using Coherent Smith-Purcell Radiation at 28GeV

Coherent Smith-Purcell radiation has been demonstrated as a technique for measuring the longitudinal profile of charged particles bunches in the low to intermediate energy range. However, with the advent of the International Linear Collider, the need has arisen for a non-invasive method of measuring the bunch profile at extremely high energies. Smith-Purcell radiation has been used for the first time in the multi-GeV regime to measure the longitudinal profile of the 28GeV SLAC beam. The experiment has both successfully determined the bunch length, and has also demonstrated its sensitivity to bunch profile changes. The challenges associated with this technique, and its prospects as a diagnostic tool are reported here.

43 PARTICLE ACCELERATORS↗

Beam Test of a High Pressure Cavity for a Muon Collider

To demonstrate the feasibility of a high pressure RF cavity for use in the cooling channel of a muon collider, an experimental setup that utilizes 400-MeV Fermilab linac proton beam has been developed. In this paper, we describe the beam diagnostics and the collimator system for the experiment, and report the initial results of the beam commissioning. The transient response of the cavity to the beam is measured by the electric and magnetic pickup probes, and the beam-gas interaction is monitored by the optical diagnostic system composed of a spectrometer and two PMTs.

43 PARTICLE ACCELERATORS↗

Palm top plasma focus device as a portable pulsed neutron source

Development of a palm top plasma focus device generating (5.2 {+-} 0.8) Multiplication-Sign 10{sup 4} neutrons/pulse into 4{pi} steradians with a pulse width of 15 {+-} 3 ns is reported for the first time. The weight of the system is less than 1.5 kg. The system comprises a compact capacitor bank, a triggered open air spark gap switch, and a sealed type miniature plasma focus tube. The setup is around 14 cm in diameter and 12.5 cm in length. The energy driver for the unit is a capacitor bank of four cylindrical commercially available electrolytic capacitors. Each capacitor is of 2 {mu}F capacity, 4.5 cm in diameter, and 9.8 cm in length. The cost of each capacitor is less than US$ 10. The internal diameter and the effective length of the plasma focus unit are 2.9 cm and 5 cm, respectively. A DC to DC converter power supply powered by two rechargeable batteries charges the capacitor bank to the desired voltage and also provides a trigger pulse of -15 kV to the spark gap. The maximum energy of operation of the device is 100 J (8 {mu}F, 5 kV, 59 kA) with deuterium gas filling pressure of 3 mbar. The neutrons have also been produced at energy as low as 36 J (3 kV) of operation. The neutron diagnostics are carried out with a bank of {sup 3}He detectors and with a plastic scintillator detector. The device is portable, reusable, and can be operated for multiple shots with a single gas filling.

43 PARTICLE ACCELERATORS↗

Undergraduate education at the University of Kentucky accelerator laboratory

The University of Kentucky accelerator laboratory provides undergraduate students an opportunity to experience scientific research in nuclear physics. They are introduced to our research program, which focuses on the examination of basic nuclear properties using the 7 MV CN Van de Graaff accelerator and the time-of-flight facility to perform inelastic neutron scattering measurements with g-ray and neutron detection. Furthermore, students are given a series of projects to support the measurements including experimental equipment setup, kinematic calculations, data collection, experimental diagnostics, MCNP simulations, analysis code development, and preliminary analysis of the data. Undergraduate physics majors from the University of Dallas took part in (n,n'g) measurements for LiF. Neutron scattering cross sections for these nuclei, which are of significant interest in coolant designs for molten salt reactors, were determined for incident neutron energies between 0.8 and 4.5 MeV. By measuring the g-ray production cross sections and feeding contributions from higher-lying levels, students extracted the neutron level cross sections for Li and F. Additional (n,n'g) measurements for Li metal will be performed in the near future to supplement the g-ray data.

43 PARTICLE ACCELERATORS↗

The DCU laser ion source

Laser ion sources are used to generate and deliver highly charged ions of various masses and energies. We present details on the design and basic parameters of the DCU laser ion source (LIS). The theoretical aspects of a high voltage (HV) linear LIS are presented and the main issues surrounding laser-plasma formation, ion extraction and modeling of beam transport in relation to the operation of a LIS are detailed. A range of laser power densities (I{approx}10{sup 8}-10{sup 11} W cm{sup -2}) and fluences (F=0.1-3.9 kJ cm{sup -2}) from a Q-switched ruby laser (full-width half-maximum pulse duration {approx}35 ns, {lambda}=694 nm) were used to generate a copper plasma. In ''basic operating mode,'' laser generated plasma ions are electrostatically accelerated using a dc HV bias (5-18 kV). A traditional einzel electrostatic lens system is utilized to transport and collimate the extracted ion beam for detection via a Faraday cup. Peak currents of up to I{approx}600 {mu}A for Cu{sup +} to Cu{sup 3+} ions were recorded. The maximum collected charge reached 94 pC (Cu{sup 2+}). Hydrodynamic simulations and ion probe diagnostics were used to study the plasma plume within the extraction gap. The system measured performance and electrodynamic simulations indicated that the use of a short field-free (L=48 mm) region results in rapid expansion of the injected ion beam in the drift tube. This severely limits the efficiency of the electrostatic lens system and consequently the sources performance. Simulations of ion beam dynamics in a ''continuous einzel array'' were performed and experimentally verified to counter the strong space-charge force present in the ion beam which results from plasma extraction close to the target surface. Ion beam acceleration and injection thus occur at ''high pressure.'' In ''enhanced operating mode,'' peak currents of 3.26 mA (Cu{sup 2+}) were recorded. The collected currents of more highly charged ions (Cu{sup 4+}-Cu{sup 6+}) increased considerably in this mode of operation.

43 PARTICLE ACCELERATORS↗

Improved design of proton source and low energy beam transport line for European Spallation Source

The design update of the European Spallation Source (ESS) accelerator is almost complete and the construction of the prototype of the microwave discharge ion source able to provide a proton beam current larger than 70 mA to the 3.6 MeV Radio Frequency Quadrupole (RFQ) started. The source named PS-ESS (Proton Source for ESS) was designed with a flexible magnetic system and an extraction system able to merge conservative solutions with significant advances. The ESS injector has taken advantage of recent theoretical updates and new plasma diagnostics tools developed at INFN-LNS (Laboratori Nazionali del Sud, Istituto Nazionale di Fisica Nucleare). The design strategy considers the PS-ESS and the low energy beam transport line as a whole, where the proton beam behaves like an almost neutralized non-thermalized plasma. Innovative solutions have been used as hereinafter described. Thermo-mechanical optimization has been performed to withstand the chopped beam and the misaligned focused beam over the RFQ input collimator; the results are reported here.

43 PARTICLE ACCELERATORS↗

Wire Scanner Assessment of Transverse Beam Size in the Fermilab Side-Coupled Linac

The Fermilab Side-Coupled Linac contains seven 805 MHz modules accelerating H- beam from 116 MeV to 400 MeV. Each module contains at least one wire scanner, yielding beam intensity at positions along a transverse direction. These wire scanners each contain three wires, mounted at different angles: "X", "Y", and 45° between "X" and "Y" to analyze coupling. Recently, a significant amount of transverse X-Y coupling was identified within wire scanner data from the Side-Coupled Linac, which has been present in data from the past decade. This realization has prompted an investigation into the wire scanner's utility as a diagnostic tool in the Fermilab Linac. This work presents efforts to better characterize the wire scanners' limitations and the phenomenon occurring in the Side-Coupled Linac.

43 PARTICLE ACCELERATORS↗

Experimental capabilities of the LMJ-PETAL facility

In this study, recent progress in the experimental capabilities of the LMJ-PETAL laser facility is reviewed. Updates on the indirect-drive D 2 implosion experiments and equation-of-state experiments using the LMJ laser are presented, including the commissioning of new plasma diagnostics. Several recent campaigns using the PETAL laser alone are also presented, namely the development of a platform using high-resolution and high-energy X-ray sources for radiography experiments, laser wakefield acceleration studies in the self-modulated regime, and neutron generation using a Target Normal Sheath Accelerated proton beam in a pitcher-catcher configuration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement and modeling of proton-induced reactions on arsenic from 35 to 200 MeV

72 As is a promising positron emitter for diagnostic imaging that can be employed locally using a 72 Se generator. However, current reaction pathways to 72 Se have insufficient nuclear data for efficient production using regional 100–200 MeV high-intensity proton accelerators. In order to address this deficiency, stacked-target irradiations were performed at LBNL, LANL, and BNL to measure the production of the 72 Se/ 72 As positron emission tomography (PET) generator system via 75 As (p, x) between 35 and 200 MeV. This work provides the most well-characterized excitation function for 75 As ( p , 4 n ) 72 Se starting from threshold. Additional focus was given to report the first measurements of 75 As (p, x) 68 Ge and bolster an already robust production capability for the highly valuable 68 Ge/ 68 Ga PET generator. Thick target yield comparisons with prior established formation routes to both generators are made. In total, high-energy proton-induced cross sections are reported for 55 measured residual products from 75 As, nat Cu , and nat Ti targets, where the latter two materials were present as monitor foils. These results were compared with literature data as well as the default theoretical calculations of the nuclear model codes TALYS, COH, EMPIRE, and ALICE. Reaction modeling at these energies is typically unsatisfactory due to few prior published data and many interacting physics models. Therefore, a detailed assessment of the talys code was performed with simultaneous parameter adjustments applied according to a standardized procedure. Particular attention was paid to the formulation of the two-component exciton model in the transition between the compound and preequilibrium regions, with a linked investigation of level density models for nuclei off of stability and their impact on modeling predictive power. This paper merges experimental work and evaluation techniques for high-energy charged-particle isotope production in an extension to an earlier study of this kind.

43 PARTICLE ACCELERATORS↗

Advanced Diagnostics of Broad Spectrum Multipactor

Multipactor is a resonance event between electron emission and RF fields causing exponential secondary electron re-emission growth when the secondary electron yield of the primary electron impact energy exceeds unity. Multipactor is a serious problem in vacuum electron devices (VEDs) such as particle accelerators, radars, electronic warfare systems, directed energy devices, and even Hall effect thrusters. It also poses an even greater threat to space communication systems where high power, multi-channel links are required. The UC Davis and SLAC team will conduct basic research to advance the fundamental understanding of multipactor physics by developing and carrying out full spectrum, radio frequency (RF) laboratory tests aimed at understanding both single and two-surface multipactor phenomena and at evaluating novel multipactor mitigation approaches for accelerator, space-based RF systems, as well as high power microwave (HPM) applications.

36 MATERIALS SCIENCE↗