Search NASA⌕ Search

SEARCH · Search NASA

Results for “biomedical data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Analysis of heat transfer and AuNPs-mediated photo-thermal inactivation of E. coli at varying laser powers using single-phase CFD modeling

In the wake of the COVID-19 pandemics, the demand for innovative and effective methods of bacterial inactivation has become a critical area of research, providing the impetus for this study. The purpose of this research is to analyze the AuNPs-mediated photothermal inactivation of E. coli. Gold nanoparticles irradiated by laser represent a promising technique for combating bacterial infection that combines high-tech and scientific progress. The intermediate aim of the work was to present the calibration of the model with respect to the gold nanorods experiment. The purpose of this work is to study the effect of initial concentration of E. coli bacteria, the design of the chamber and the laser power on heat transfer and inactivation of E. coli bacteria. Using the CFD simulation, the work combines three main concepts. 1. The conversion of laser light to heat has been described by a combination of three distinctive approximations: a- Discrete particle integration to take into account every nanoparticle within the system, b- Rayleigh-Drude approximation to determine the scattering and extinction coefficients and c- Lambert–Beer–Bourger law to describe the decrease in laser intensity across the AuNPs. 2. The contribution of the presence of E. coli bacteria to the thermal and fluid-dynamic fields in the microdevice was modeled by single-phase approach by determining the effective thermophysical properties of the water-bacteria mixture. 3. An approach based on a temperature threshold attained at which bacteria will be inactivated, has been used to predict bacterial response to temperature increases. The comparison of the thermal fields and temporal temperature changes obtained by the CFD simulation with those obtained experimentally confirms the accuracy of the light-heat conversion model derived from the aforementioned approximations. The results show a linear relationship between maximum temperature and variation in laser power over the range studied, which is in line with previous experimental results. It was also found that the temperature inside the microchamber can exceed 55 °C only when a laser power higher than 0.8 W is used, so bacterial inactivation begins. The experimental data allows to determinate the concentration of nanoparticles. This parameter is introduced into the mathematical model obtaining the same number of AuNPs. However, this assumption introduces a certain simplification, as in the mathematical model the distribution of nanoparticles is uniform. This work is directly connected to the use of gold nanoparticles for energy conversion, as well as the field of bacterial inactivation in microfluidic systems such as lab-on-a-chip. Presented mathematical and numerical models can be extended to the entire spectrum of wavelengths with particular use of white light in the inactivation of bacteria. This work represents a significant advancement in the field, as to the best of the authors’ knowledge, it is the first to employ a single-phase computational fluid dynamics (CFD) approach specifically combined with the thermal inactivation of bacteria. Moreover, this research pioneers the use of a numerical simulation to analyze the temperature threshold of photothermal inactivation of E. coli mediated by gold nanorods (AuNRs). The integration of these methodologies offers a new perspective on optimizing bacterial inactivation techniques, making this study a valuable contribution to both computational modeling and biomedical applications.

36 MATERIALS SCIENCE↗

A database of thermally activated delayed fluorescent molecules auto-generated from scientific literature with ChemDataExtractor

A database of thermally activated delayed fluorescent (TADF) molecules was automatically generated from the scientific literature. It consists of 25,482 data records with an overall precision of 82%. Among these, 5,349 records have chemical names in the form of SMILES strings which are represented with 91% accuracy; these are grouped in a subsidiary database. Each data record contains one of the following four properties: maximum emission wavelength (λ EM ), photoluminescence quantum yield (PLQY), singlet-triplet energy splitting (ΔE ST ), and delayed lifetime (τ D ). The databases were created through text mining using ChemDataExtractor, a chemistry-aware natural-language-processing toolkit, which has been adapted for TADF research. The text-mined corpus consisted of 2,733 papers from the Royal Society of Chemistry and Elsevier. To the best of our knowledge, these databases are the first databases that have been auto-generated for TADF molecules from existing publications. The databases have been publicly released for experimental and computational applications in the TADF research field.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A new clinical unit for digital radiography based on a thick amorphous Selenium plate: Physical and psychophysical characterization

Purpose: Here, we present a physical and psychophysical characterization of a new clinical unit (named AcSelerate) for digital radiography based on a thick a-Se layer. We also compared images acquired with and without a software filter (named CRF) developed for reducing sharpness and noise of the images and making them similar to images coming from traditional computed radiography systems. Methods: The characterization was achieved in terms of physical figures of merit [modulation transfer function (MTF), noise power spectra (NPS), detective quantum efficiency (DQE)], and psychophysical parameters (contrast-detail analysis with an automatic reading of CDRAD images). We accomplished measurements with four standard beam conditions: RAQ3, RQA5, RQA7, and RQA9. Results: The system shows an excellent MTF (about 50% at the Nyquist frequency). The DQE is about 55% at 0.5 lp/mm and above 20% at the Nyquist frequency and is almost independent from exposure. The contrast-detail curves are comparable to some of the best published data for other systems devoted to imaging in general radiography. The CRF filter influences both the MTF and NPS, but it does lead to very small changes on DQE. Also the visibility of CDRAD details is basically unaltered, when the filter is activated. Conclusions: As normally happens with detector based on direct conversion, the system presents an excellent MTF. The improved efficiency caused by the thick layer allows getting good noise characteristics and DQE results better (about 10% on average) than many of the computed radiography (CR) systems and comparable to those obtained by the best systems for digital radiography available on the market.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-09: A Dosimetric Analysis of Various Clinically Used Bolus Materials

Purpose: To evaluate the dosimetric effect of various clinically used bolus materials. Methods: Materials investigated include solid water, superflab, wet gauze, wet sheets, Play-Doh{sup ™}, and gauze embedded with petroleum jelly. Each bolusing material was scanned in a Philips CT to determine the Hounsfield unit (HU) and to verify uniformity throughout the material. Using the corresponding HU, boluses of 0.5 cm and 1.0 cm thicknesses were created in the Eclipse treatment planning system (TPS) on a solid water phantom. Dose was calculated at various depths for beam energies 6 MV, 6 MeV, 9 MeV, and 12 MeV to determine the effects of each material on deposition of dose. In addition, linac-based measurements at these energies were made using a farmer chamber in solid water. Wet sheets and wet gauze were measured with various water content to quantify the effects on dose. Results: Preliminary CT scans find a range in HU of bolus materials from −120 to almost 300. There is a trend in the dose at depth based on the HU of the material; however inconsistencies are found when the bolus materials have a negative HU value. The measured data indicates that there is a linear relationship between the mass of water in a material and the dose reading, the slope of which is material dependent. Conclusion: Due to the variation in HU of the bolus materials studied, it is recommended that any new bolus be evaluated before clinical use to determine physical and dosimetric properties. If possible, patients should have bolus included in their CT scans; or if the bolus is created in the TPS, the HU should correspond to the material used. For water-soaked materials, once the bolus material is selected (gauze or sheet), the bolusing effect is only dependent on the amount of water applied to the material.

60 APPLIED LIFE SCIENCES↗

TU-G-303-01: Radiomics: Quantitative Imaging in the Service of Improved Treatment Decision Making

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-02: Robust Radiomics Methods for PET and CT Imaging

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

TU-G-303-03: Machine Learning to Improve Human Learning From Longitudinal Image Sets

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

Safety and Effectiveness of UFE in Fibroids Larger than 10 cm

IntroductionEarly literature suggested that the size of the uterus, the size of the dominant fibroid, and the amount of applied embolization particles would be the risk factors for major postprocedural complications, but recent publications have confuted these early results. The purpose of our study was to evaluate whether the size of the dominant fibroid would influence the complication rate and effectiveness in a large single-center cohort.Patients and MethodsFrom 28 April 2008 until 31 December 2012, 303 patients had uterine artery embolization (UAE). 262 patients had small [largest diameter <10 cm (Group 1)], 41 patients had large [largest diameter >10 cm (Group 2)] fibroid. UAE was performed from unilateral femoral access using 500–710 and 355–500 µm polyvinyl alcohol particles. Periprocedural and postprocedural complications and numerical analog quality-of-life scores (0—unbearable symptoms; 100—perfect quality of life) were listed and statistically analyzed.ResultsDuring the mean follow-up time [7.79 ± 5.16 (SD) month], data on 275 patients (275/303 = 90.8 %) were available. Quality-of-life score was 33.3 ± 23.5 and 33.5 ± 24.1 before, whereas 85.6 ± 16.0 and 81.5 ± 23.5 after UAE in Group 1 and Group 2, respectively, (Mann–Whitney U test one-sided, p = 0.365). There were 4 myoma expulsions, 1 acute myomectomy, and 2 acute hysterectomies reported from Group 1, meanwhile 1 myoma expulsion, 1 acute myomectomy, and 2 acute hysterectomies were documented from Group 2 (NS differences).ConclusionThere was no significant difference in the effectiveness and in the number of minor and major complications between fibroids with <10 cm largest diameter compared to those >10 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-G-303-04: Radiomics and the Coming Pan-Omics Revolution

‘Radiomics’ refers to studies that extract a large amount of quantitative information from medical imaging studies as a basis for characterizing a specific aspect of patient health. Radiomics models can be built to address a wide range of outcome predictions, clinical decisions, basic cancer biology, etc. For example, radiomics models can be built to predict the aggressiveness of an imaged cancer, cancer gene expression characteristics (radiogenomics), radiation therapy treatment response, etc. Technically, radiomics brings together quantitative imaging, computer vision/image processing, and machine learning. In this symposium, speakers will discuss approaches to radiomics investigations, including: longitudinal radiomics, radiomics combined with other biomarkers (‘pan-omics’), radiomics for various imaging modalities (CT, MRI, and PET), and the use of registered multi-modality imaging datasets as a basis for radiomics. There are many challenges to the eventual use of radiomics-derived methods in clinical practice, including: standardization and robustness of selected metrics, accruing the data required, building and validating the resulting models, registering longitudinal data that often involve significant patient changes, reliable automated cancer segmentation tools, etc. Despite the hurdles, results achieved so far indicate the tremendous potential of this general approach to quantifying and using data from medical images. Specific applications of radiomics to be presented in this symposium will include: the longitudinal analysis of patients with low-grade gliomas; automatic detection and assessment of patients with metastatic bone lesions; image-based monitoring of patients with growing lymph nodes; predicting radiotherapy outcomes using multi-modality radiomics; and studies relating radiomics with genomics in lung cancer and glioblastoma. Learning Objectives: Understanding the basic image features that are often used in radiomic models. Understanding requirements for reliable radiomic models, including robustness of metrics, adequate predictive accuracy, and generalizability. Understanding the methodology behind radiomic-genomic (’radiogenomics’) correlations. Research supported by NIH (US), CIHR (Canada), and NSERC (Canada)

60 APPLIED LIFE SCIENCES↗

Earth benefits from space life sciences

Contributions of space exploration which are widely recognized are those dealing with the impact of space technology on public health and medical services in both urban and remote rural areas. Telecommunications, image enhancement, 3-dimensional image reconstructions, miniaturization, automation, and data analysis, have transformed the delivery of medical care and have brought about a new impetus to the field of biomedicine. Many areas of medical care and biological research have been affected. These include technological breakthroughs in such areas as: (1) diagnosis, treatment, and prevention of cardiovascular diseases, (2) new approaches to the understanding of osteoporosis, (3) early detection of genetic birth defects, (4) emergency medical care, and (5) treatment of chronic metabolic disorders. These are but a few examples where technology originally developed to support space medicine or space research has been applied to solving medical and health care delivery problems on Earth.

NASA Center HQS↗

Effects of orbital spaceflight on human osteoblastic cell physiology and gene expression

During long-term spaceflight, astronauts lose bone, in part due to a reduction in bone formation. It is not clear, however, whether the force imparted by gravity has direct effects on bone cells. To examine the response of bone forming cells to weightlessness, human fetal osteoblastic (hFOB) cells were cultured during the 17 day STS-80 space shuttle mission. Fractions of conditioned media were collected during flight and shortly after landing for analyses of glucose utilization and accumulation of type I collagen and prostaglandin E(2) (PGE(2)). Total cellular RNA was isolated from flight and ground control cultures after landing. Measurement of glucose levels in conditioned media indicated that glucose utilization occurred at a similar rate in flight and ground control cultures. Furthermore, the levels of type I collagen and PGE(2) accumulation in the flight and control conditioned media were indistinguishable. The steady-state levels of osteonectin, alkaline phosphatase, and osteocalcin messenger RNA (mRNA) were not significantly changed following spaceflight. Gene-specific reductions in mRNA levels for cytokines and skeletal growth factors were detected in the flight cultures using RNase protection assays. Steady-state mRNA levels for interleukin (IL)-1alpha and IL-6 were decreased 8 h following the flight and returned to control levels at 24 h postflight. Also, transforming growth factor (TGF)-beta(2) and TGF-beta(1) message levels were modestly reduced at 8 h and 24 h postflight, although the change was not statistically significant at 8 h. These data suggest that spaceflight did not significantly affect hFOB cell proliferation, expression of type I collagen, or PGE(2) production, further suggesting that the removal of osteoblastic cells from the context of the bone tissue results in a reduced ability to respond to weightlessness. However, spaceflight followed by return to earth significantly impacted the expression of cytokines and skeletal growth factors, which have been implicated as mediators of the bone remodeling cycle. It is not yet clear whether these latter changes were due to weightlessness or to the transient increase in loading resulting from reentry.

Non-NASA Center↗

An effective “three-in-one” screening assay for testing drug and nanoparticle toxicity in human endothelial cells

Evaluating nanoparticle (NP) toxicity in human cell systems is a fundamental requirement for future NP biomedical applications. In this study, we have designed a screening assay for assessing different types of cell death induced by NPs in human umbilical vein endothelial cell (HUVEC) culture. This assay consists of WST-8, LDH and Hoechst 33342 staining, all performed in one well, which enables an evaluation of cell viability, necrosis and apoptosis, respectively, in the same cell sample. The 96-well format and automated processing of fluorescent images enhances the assay rapidity and reproducibility. After testing the assay functionality with agents that induced different types of cell death, we investigated the endothelial toxicity of superparamagnetic iron oxide nanoparticles (SPIONs, 8 nm), silica nanoparticles (SiNPs, 7–14 nm) and carboxylated multiwall carbon nanotubes (CNTCOOHs, 60 nm). Our results indicated that all the tested NP types induced decreases in cell viability after 24 hours at a concentration of 100 μg/ml. SPIONs caused the lowest toxicity in HUVECs. By contrast, SiNPs induced pronounced necrosis and apoptosis. A time course experiment showed the gradual toxic effect of all the tested NPs. CNTCOOHs inhibited tetrazolium derivatives at 100 μg/ml, causing false negative results from the WST-8 and LDH assay. In summary, our data demonstrate that the presented “three-in-one” screening assay is capable of evaluating NP toxicity effectively and reliably. Due to its simultaneous utilization of two different methods to assess cell viability, this assay is also capable of revealing, if NPs interfere with tetrazolium salts.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-U-02: The Development of a Practical Ultrasonic System for Cross-Sectional Imaging of Small Animals

Purpose: To test the feasibility of developing a practical medium frequency ultrasound tomography method for small animal imaging. The ability to produce cross-sectional or full body images of a live small animal using a low-cost tabletop ultrasound scanner without any special license would be very beneficial to long term biological studies, where repeated scanning is often required over an extended period of time. Methods: The cross sectional images were produced by compounding multiple B-scans of a laboratory phantom or an animal acquired at different projection angles. Two imaging systems were used to test the concept. The first system included a programmable 64-channel phased array controller driving a 128-channel, 5–10 MHz linear probe to produce 143 B-Mode projections of the spinning object. The second system designed and manufactured in house, produced 64 or 128 B-Mode projections with a single unfocused 8 MHz transducer scanning with a 0.116 mm step size. Results: The phased array system provided good penetration through the phantoms/mice (with the exception of the lungs) and allowed to acquire data in a very short time. The cross-sectional images have enough resolution and dynamic range to detect both high- and low-contrast organs. The single transducer system takes longer to scan, and the data require more sophisticated processing. To date, our images allow seeing details as small as 1–2 mm in the phantoms and in small animals, with the contrast mostly due to highly reflecting bones and air inclusions. Conclusion: The work indicates that very detailed and anatomically correct images can be created by relatively simple and inexpensive means. With more advanced algorithms and improved system design, scan time can be reduced considerably, enabling high-resolution full 3D imaging. This will allow for quick and easy scans that can help monitor tumor growth and/or regression without contributing any dose to the animal. The authors would like to acknowledge the financial and engineering support from Tessonics.

60 APPLIED LIFE SCIENCES↗

Near-infrared spectral imaging of the female breast for quantitative oximetry in optical mammography

We present a hybrid continuous-wave, frequency-domain instrument for near-infrared spectral imaging of the female breast based on a tandem, planar scanning of one illumination optical fiber and one collection optical fiber configured in a transmission geometry. The spatial sampling rate of 25 points/cm{sup 2} is increased to 400 points/cm{sup 2} by postprocessing the data with a 2D cubic spline interpolation. We then apply a previously developed spatial second-derivative algorithm to an edge-corrected intensity image (N-image) to enhance the visibility and resolution of optical inhomogeneities in breast tissue such as blood vessels and tumors. The spectral data at each image pixel consist of 515-point spectra over the 650-900 nm wavelength range, thus featuring a spectral density of two data points per nanometer. We process the measured spectra with a paired-wavelength spectral analysis method to quantify the oxygen saturation of detected optical inhomogeneities, under the assumption that they feature a locally higher hemoglobin concentration. Our initial measurements on two healthy human subjects have generated high-resolution optical mammograms displaying a network of blood vessels with values of hemoglobin saturation typically falling within the 60%-95% range, which is physiologically reasonable. This approach to spectral imaging and oximetry of the breast has the potential to efficiently exploit the high intrinsic contrast provided by hemoglobin in breast tissue and to contribute a useful tool in the detection, diagnosis, and monitoring of breast pathologies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Automated detection of microcalcification clusters for digital breast tomosynthesis using projection data only: A preliminary study

Digital breast tomosynthesis (DBT) is a promising modality for breast imaging in which an anisotropic volume image of the breast is obtained. We present an algorithm for computerized detection of microcalcification clusters (MCCs) for DBT. This algorithm operates on the projection views only. Therefore it does not depend on reconstruction, and is computationally efficient. The algorithm was developed using a database of 30 image sets with microcalcifications, and a control group of 30 image sets without visible findings. The patient data were acquired on the first DBT prototype at Massachusetts General Hospital. Algorithm sensitivity was estimated to be 0.86 at 1.3 false positive clusters, which is below that of current MCC detection algorithms for full-field digital mammography. Because of the small number of patient cases, algorithm parameters were not optimized and one linear classifier was used. An actual limitation of our approach may be that the signal-to-noise ratio in the projection images is too low for microcalcification detection. Furthermore, the database consisted of predominantly small MCC. This may be related to the image quality obtained with this first prototype.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-G-BRD-02: Characterizing Information Loss in a Sparse-Sampling-Based Dynamic MRI Sequence (k-T BLAST) for Lung Motion Monitoring

Purpose: Rapid MRI is an attractive, non-ionizing tool for soft-tissue-based monitoring of respiratory motion in thoracic and abdominal radiotherapy. One big challenge is to achieve high temporal resolution while maintaining adequate spatial resolution. K-t BLAST, sparse-sampling and reconstruction sequence based on a-priori information represents a potential solution. In this work, we investigated how much “true” motion information is lost as a-priori information is progressively added for faster imaging. Methods: Lung tumor motions in superior-inferior direction obtained from ten individuals were replayed into an in-house, MRI-compatible, programmable motion platform (50Hz refresh and 100microns precision). Six water-filled 1.5ml tubes were placed on it as fiducial markers. Dynamic marker motion within a coronal slice (FOV: 32×32cm{sup 2}, resolution: 0.67×0.67mm{sup 2}, slice-thickness: 5mm) was collected on 3.0T body scanner (Ingenia, Philips). Balanced-FFE (TE/TR: 1.3ms/2.5ms, flip-angle: 40degrees) was used in conjunction with k-t BLAST. Each motion was repeated four times as four k-t acceleration factors 1, 2, 5, and 16 (corresponding frame rates were 2.5, 4.7, 9.8, and 19.1Hz, respectively) were compared. For each image set, one average motion trajectory was computed from six marker displacements. Root mean square error (RMS) was used as a metric of spatial accuracy where measured trajectories were compared to original data. Results: Tumor motion was approximately 10mm. The mean(standard deviation) of respiratory rates over ten patients was 0.28(0.06)Hz. Cumulative distributions of tumor motion frequency spectra (0–25Hz) obtained from the patients showed that 90% of motion fell on 3.88Hz or less. Therefore, the frame rate must be a double or higher for accurate monitoring. The RMS errors over patients for k-t factors of 1, 2, 5, and 16 were.10(.04),.17(.04), .21(.06) and.26(.06)mm, respectively. Conclusions: K-t factor of 5 or higher can cover the high frequency component of tumor respiratory motion, while the estimated error of spatial accuracy was approximately.2mm.

60 APPLIED LIFE SCIENCES↗

SU-F-J-150: Development of An End-To-End Chain Test for the First-In-Man MR-Guided Treatments with the MRI Linear Accelerator by Using the Alderson Phantom

The Alderson phantom is a human shaped quality assurance tool that has been used for over 30 years in radiotherapy. The phantom can provide integrated tests of the entire chain of treatment planning and delivery. The purpose of this research was to investigate if this phantom can be used to chain test a treatment on the MRI linear accelerator (MRL) which is currently being developed at the UMC Utrecht, in collaboration with Elekta and Philips. The latter was demonstrated by chain testing the future First-in-Man treatments with this system.An Alderson phantom was used to chain test an entire treatment with the MRL. First, a CT was acquired of the phantom with additional markers that are both visible on MR and CT. A treatment plan for treating bone metastases in the sacrum was made. The phantom was consecutively placed in the MRL. For MRI imaging, an 3D volume was acquired. The initially developed treatment plan was then simulated on the new MRI dataset. For simulation, both the MR and CT data was used by registering them together. Before treatment delivery a MV image was acquired and compared with a DRR that was calculated form the MR/CT registration data. Finally, the treatment was delivered. Figure 1 shows both the T1 weighted MR-image of the phantom and the CT that was registered to the MR image. Figure 2 shows both the calculated and measured MV image that was acquired by the MV panel. Figure 3 shows the dose distribution that was simulated. The total elapsed time for the entire procedure excluding irradiation was 13:35 minutes.The Alderson Phantom yields sufficient MR contrast and can be used for full MR guided radiotherapy treatment chain testing. As a result, we are able to perform an end-to-end chain test of the future First-in-Man treatments.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP1-15: Towards Accurate Cerebral Blood Flow Quantification with Distortion- Corrected Pseudo-Continuous Arterial Spin Labeling

Purpose: Traditional arterial spin labeling (ASL) acquisitions with echo planar imaging (EPI) readouts suffer from image distortion due to susceptibility effects, compromising ASL’s ability to accurately quantify cerebral blood flow (CBF) and assess disease-specific patterns associated with CBF abnormalities. Phase labeling for additional coordinate encoding (PLACE) can remove image distortion; our goal is to apply PLACE to improve the quantitative accuracy of ASL CBF in humans. Methods: Four subjects were imaged on a 3T Philips Ingenia scanner using a 16-channel receive coil with a 21/21/10cm (frequency/phase/slice direction) field-of-view. An ASL sequence with a pseudo-continuous ASL (pCASL) labeling scheme was employed to acquire thirty dynamics of single-shot EPI data, with control and label datasets for all dynamics, and PLACE gradients applied on odd dynamics. Parameters included a post-labeling delay = 2s, label duration = 1.8s, flip angle = 90°, TR/TE = 5000/23.5ms, and 2.9/2.9/5.0mm (frequency/phase/slice direction) voxel size. “M0” EPI-reference images and T1-weighted spin-echo images with 0.8/1.0/3.3mm (frequency/phase/slice directions) voxel size were also acquired. Complex conjugate image products of pCASL odd and even dynamics were formed, a linear phase ramp applied, and data expanded and smoothed. Data phase was extracted to map control, label, and M0 magnitude image pixels to their undistorted locations, and images were rebinned to original size. All images were corrected for motion artifacts in FSL 5.0. pCASL images were registered to M0 images, and control and label images were subtracted to compute quantitative CBF maps. Results: pCASL image and CBF map distortions were removed by PLACE in all subjects. Corrected images conformed well to the anatomical T1-weighted reference image, and deviations in corrected CBF maps were evident. Conclusion: Eliminating pCASL distortion with PLACE can improve CBF quantification accuracy using minimal pulse sequence modifications and no additional scan time, improving ASL’s clinical applicability.

60 APPLIED LIFE SCIENCES↗