Search NASA⌕ Search

SEARCH · Search NASA

Results for “data locality”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Effects of Nose Radius and Extreme Cooling on Boundary-Layer Transition for Three Smooth 15°-Cone-Cylinders in Free Flight at Mach Numbers to 8.50

Three highly polished 15°- included- angle cone- cylinders with hemispherical tips of several diameters ( 2, 3, and 4 in.) have been flown in order to obtain boundary- layer transition data at very low wall to local stream temperature ratios, and heat- transfer data. All surfaces had a 2-microinch average roughness height. Laminar flow existed over the entire hemispherical nose of the 2- and 3-inch-tip- diameter models throughout the complete flight history. Extreme cooling to wall to local stream temperature ratios at the sonic point as low as 0.20 did not cause transition on the nose for diameters as large as 3 inches. However, extreme cooling did cause early transition on the 4-inch model where it appears probable that transition occurred forward of the 45° station at a wall to local stream temperature ratio of about 0.26. Variations in tip diameter influenced transition downstream of the nose under conditions of extreme cooling. The 2-inch- tip model was laminar at all cone- cylinder stations at temperature ratios as low as 0.32 whereas the 3- and 4-inch-tip models were turbulent at the same local flow conditions but at higher wall to local temperature ratios. Transition on the cone and cylinder of the 3- and 4-inch- tip bodies appeared to be sensitive to local Mach number, and occurred at higher local temperature ratios when values of local Mach number were higher. Increasing the nose diameter from 2 to 3 inches significantly changed the local flow conditions for which laminar flow existed on the cone- cylinder afterbody. However, a further increase in tip size t o a 4-inch diameter had no discernable effect on the local flow conditions at transition. The transition results of the 3- and 4-inch-nose-diameter smooth bodies are similar to those observed on a 7/8-inch-nose-diameter body with roughened surfaces. Turbulent boundary layers resulted in both cases at very low wall to local stream temperature ratios. Both laminar and turbulent heat-transfer data were in good agreement with theoretical Stanton numbers when heat-transfer reduction due to tip blunting was considered.

CYLINDRICAL AFTERBODY↗

Detection and Characterization of Natural and Induced Fractures for the Development of Enhanced Geothermal Systems

The objective of this 3-year project is to use various geophysical methods for reservoir and fracture characterization. The targeted field is the Cove Fort-Sulphurdale Geothermal Field in Utah operated by ENEL North America (ENA). Our effort has been focused on 1) understanding the regional and local geological settings around the geothermal field; 2) collecting and assembling various geophysical data sets including heat flow, gravity, magnetotelluric (MT) and seismic surface and body wave data; 3) installing the local temporary seismic network around the geothermal site; 4) imaging the regional and local seismic velocity structure around the geothermal field using seismic travel time tomography; and (5) determining the fracture direction using the shear-wave splitting analysis and focal mechanism analysis. Various geophysical data sets indicate that beneath the Cove Fort-Sulphurdale Geothermal Field, there is a strong anomaly of low seismic velocity, low gravity, high heat flow and high electrical conductivity. These suggest that there is a heat source in the crust beneath the geothermal field. The high-temperature body is on average 150 °C – 200 °C hotter than the surrounding rock. The local seismic velocity and attenuation tomography gives a detailed velocity and attenuation model around the geothermal site, which shows that the major geothermal development target is a high velocity body near surface, composed mainly of monzonite. The major fracture direction points to NNE. The detailed velocity model along with the fracture direction will be helpful for guiding the geothermal development in the Cove Fort area.

15 GEOTHERMAL ENERGY↗

Coarse-grained modeling of DNA curvature

The interaction of DNA with proteins occurs over a wide range of length scales, and depends critically on its local structure. In particular, recent experimental work suggests that the intrinsic curvature of DNA plays a significant role on its protein-binding properties. In this work, we present a coarse grained model of DNA that is capable of describing base-pairing, hybridization, major and minor groove widths, and local curvature. The model represents an extension of the recently proposed 3SPN.2 description of DNA [D. M. Hinckley, G. S. Freeman, J. K. Whitmer, and J. J. de Pablo, J. Chem. Phys. 139, 144903 (2013)], into which sequence-dependent shape and mechanical properties are incorporated. The proposed model is validated against experimental data including melting temperatures, local flexibilities, dsDNA persistence lengths, and minor groove width profiles.

Freeman, Gordon S.↗

Digital Astronaut Project Biomechanical Models: Biomechanical Modeling of Squat, Single-Leg Squat and Heel Raise Exercises on the Hybrid Ultimate Lifting Kit (HULK)

The NASA Digital Astronaut Project (DAP) implements well-vetted computational models to predict and assess spaceflight health and performance risks, and to enhance countermeasure development. The DAP Musculoskeletal Modeling effort is developing computational models to inform exercise countermeasure development and to predict physical performance capabilities after a length of time in space. For example, integrated exercise device-biomechanical models can determine localized loading, which will be used as input to muscle and bone adaptation models to estimate the effectiveness of the exercise countermeasure. In addition, simulations of mission tasks can be used to estimate the astronaut's ability to perform the task after exposure to microgravity and after using various exercise countermeasures. The software package OpenSim (Stanford University, Palo Alto, CA) (Ref. 1) is being used to create the DAP biomechanical models and its built-in muscle model is the starting point for the DAP muscle model. During Exploration missions, such as those to asteroids and Mars, astronauts will be exposed to reduced gravity for extended periods. Therefore, the crew must have access to exercise countermeasures that can maintain their musculoskeletal and aerobic health. Exploration vehicles may have very limited volume and power available to accommodate such capabilities, even more so than the International Space Station (ISS). The exercise devices flown on Exploration missions must be designed to provide sufficient load during the performance of various resistance and aerobic/anaerobic exercises while meeting potential additional requirements of limited mass, volume and power. Given that it is not practical to manufacture and test (ground, analog and/or flight) all candidate devices, nor is it always possible to obtain data such as localized muscle and bone loading empirically, computational modeling can estimate the localized loading during various exercise modalities performed on a given device to help formulate exercise prescriptions and other operational considerations. With this in mind, NASA's Digital Astronaut Project (DAP) is supporting the Advanced Exercise Concepts (AEC) Project, Exercise Physiology and Countermeasures (ExPC) laboratory and NSBRI-funded researchers by developing and implementing well-validated computational models of exercises with advanced exercise device concepts. This report focuses specifically on lower-body resistance exercises performed with the Hybrid Ultimate Lifting Kit (HULK) device as a deliverable to the AEC Project.

health↗

Sulfur isotope analysis of microcrystalline iron sulfides using secondary ion mass spectrometry imaging: Extracting local paleo-environmental information from modern and ancient sediments

Rationale: Sulfur isotope ratio measurements of bulk sulfide from marine sediments have often been used to reconstruct environmental conditions associated with their formation. In situ microscale spot analyses by secondary ion mass spectrometry (SIMS) and laser ablation multiple-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) have been utilized for the same purpose. However, these techniques are often not suitable for studying small (≤10 μm) grains or for detecting intra-grain variability. Methods: In this work, we present a method for the physical extraction (using lithium polytungstate heavy liquid) and subsequent sulfur isotope analysis (using SIMS; CAMECA IMS 7f-GEO) of microcrystalline iron sulfides. SIMS sulfur isotope ratio measurements were made via Cs + bombardment of raster squares with sides of 20–130 μm, using an electron multiplier (EM) detector to collect counts of 32 S - and 34 S - for each pixel (128 × 128 pixel grids) for between 20 and 960 cycles. Results: The extraction procedure did not discernibly alter pyrite grain-size distributions. The apparent inter-grain variability in 34 S/ 32 S in 1–4 μm-sized pyrite and marcasite fragments from isotopically homogeneous hydrothermal crystals was ~ ±2‰ (1σ), comparable with the standard error of the mean for individual measurements (≤ ±2‰, 1σ). In contrast, grain-specific 34 S/ 32 S ratios in modern and ancient sedimentary pyrites and marcasites can have inter- and intra-grain variability >60‰. The distributions of intra-sample isotopic variability are consistent with bulk 34 S/ 32 S values. Conclusions: SIMS analyses of isolated iron sulfide grains yielded distributions that are isotopically representative of bulk 34 S/ 32 S values. Populations of iron sulfide grains from sedimentary samples record the evolution of the S-isotopic composition of pore water sulfide in their S-isotopic compositions. These data allow past local environmental conditions to be inferred.

59 BASIC BIOLOGICAL SCIENCES↗

Communications protocols for a fault tolerant, integrated local area network for Space Station applications

The evolutionary growth of the Space Station and the diverse activities onboard are expected to require a hierarchy of integrated,local area networks capable of supporting data, voice and video communications. In addition, fault tolerant network operation is necessary to protect communications between critical systems attached to the net and to relieve the valuable human resources onboard Space Station of day-to-day data system repair tasks. An experimental, local area network is being developed which will serve as a testbed for investigating candidate algorithms and technologies for a fault tolerant, integrated network. The establishment of a set of rules or protocols which govern communications on the net is essential to obtain orderly and reliable operation. A hierarchy of protocols for the experimental network is presented and procedures for data and control communications are described.

Meredith, B. D.↗

Comparing Low-Cost Sensors with Ground-Based and Airborne In-Situ and Column Observations of NO2 and HCHO during the FRAPPE Field Campaign in Colorado, USA

Even in the presence of more reliable air quality tools, low-cost sensors have the benefit of recording data on highly localized spatial and temporal scales, allowing for multiple measurements within a single satellite pixel and on pixel boundaries. However, they are less accurate than their regulatory-grade counterparts, requiring regular co-locations with accepted instruments to ensure their validity. Thus, the addition of low-cost sensors to a field campaign – where reference-grade air quality instruments are abundant – not only provides ample opportunities for low-cost sensor co-location and calibration, but also allows the low-cost instruments to be used for sub-pixel validation, covering more surface area than the regulatory instruments alone with a network of sensors. During the summer of 2014, our low-cost sensor network was deployed during the Front Range Air Pollution and Photochemistry Experiment (FRAPPÉ) campaign conducted to sample the composition of air at and above ground level in northeastern Colorado, USA. The low-cost sensor platform included a suite of gas-phase sensors, notably NO2 and two generalized volatile organic compound (VOC) sensors, which were leveraged together to quantify speciated hydrocarbons such as formaldehyde. These key pollutants were chosen for their impacts on human health and climate change, as well as their inclusion on the TEMPO satellite launching this year. Airborne campaign measurements included slant column optical observations of formaldehyde (HCHO), nitrogen dioxide (NO2), and ozone (O3). Myriad additional in-situ instruments described chemical composition up to approximately 5 km above surface level. Ground-based instrumentation included both stationary and mobile regulatory-grade instruments, which were used for sensor calibration. Machine learning techniques such as artificial neural networks (ANNs) were used to match the low-cost signals to that of the reference-grade instruments. Here, we compare calibrated low-cost sensor data collected at ground level in a variety of locations along Colorado’s Front Range to various data sources from the FRAPPÉ campaign to better understand how well airborne and regulatory ground-based measurements can be extrapolated to other locations. Further, as the slant column measurements act as satellite simulators, we explore how low-cost instruments can be used for satellite validation purposes. Comparisons among these different data types also have important implications in data fusion.

Kristen Okorn↗

Integration of a Decentralized Linear-Quadratic-Gaussian Control into GSFC's Universal 3-D Autonomous Formation Flying Algorithm

A decentralized control is investigated for applicability to the autonomous formation flying control algorithm developed by GSFC for the New Millenium Program Earth Observer-1 (EO-1) mission. This decentralized framework has the following characteristics: The approach is non-hierarchical, and coordination by a central supervisor is not required; Detected failures degrade the system performance gracefully; Each node in the decentralized network processes only its own measurement data, in parallel with the other nodes; Although the total computational burden over the entire network is greater than it would be for a single, centralized controller, fewer computations are required locally at each node; Requirements for data transmission between nodes are limited to only the dimension of the control vector, at the cost of maintaining a local additional data vector. The data vector compresses all past measurement history from all the nodes into a single vector of the dimension of the state; and The approach is optimal with respect to standard cost functions. The current approach is valid for linear time-invariant systems only. Similar to the GSFC formation flying algorithm, the extension to linear LQG time-varying systems requires that each node propagate its filter covariance forward (navigation) and controller Riccati matrix backward (guidance) at each time step. Extension of the GSFC algorithm to non-linear systems can also be accomplished via linearization about a reference trajectory in the standard fashion, or linearization about the current state estimate as with the extended Kalman filter. To investigate the feasibility of the decentralized integration with the GSFC algorithm, an existing centralized LQG design for a single spacecraft orbit control problem is adapted to the decentralized framework while using the GSFC algorithm's state transition matrices and framework. The existing GSFC design uses both reference trajectories of each spacecraft in formation and by appropriate choice of coordinates and simplified measurement modeling is formulated as a linear time-invariant system. Results for improvements to the GSFC algorithm and a multiple satellite formation will be addressed. The goal of this investigation is to progressively relax the assumptions that result in linear time-invariance, ultimately to the point of linearization of the non-linear dynamics about the current state estimate as in the extended Kalman filter. An assessment will then be made about the feasibility of the decentralized approach to the realistic formation flying application of the EO-1/Landsat 7 formation flying experiment.

Folta, David C.↗

Design of 3D Oxide–Metal Hybrid Metamaterial for Tailorable Light–Matter Interactions in Visible and Near-Infrared Region

Dielectric–metallic hybrid metamaterials exhibit extraordinary optical properties due to the light–matter interactions at the dielectric–metallic interfaces. The ability in precision control of the light–matter interactions in nanoscale is key to tailor the optical properties of hybrid metamaterials. In this work, a complex 3D framework of multilayered self-assembled BaTiO 3 (BTO)-Au hybrid thin films is demonstrated with such precision control of the light–matter interaction in nanoscale. Here, unique “bamboo-like” Au nanostructures are formed via the bilayer and trilayer stacking of BTO-Au hybrid layers with interlayers of SrTiO 3 , CeO 2 , or MgO. Different film strain states introduced by the three interlayers result in variable diameter and density of Au nanopillars. Both simulated and experimental optical data demonstrate the localized surface plasmon resonance change and hyperbolic dispersion wavelength shift in visible to near-infrared because of the effective tuning of the Au nanopillar aspect ratio and free electron density. The highly tunable optical properties along with the ferroelectric behavior and thermal robustness of the 3D hybrid film enable it to be a great candidate for multifunctional applications. This study demonstrates a unique 3D approach for precision optical property tuning and combined functionalities in oxide–metal metamaterial systems toward future integrated photonic and electronic devices.

36 MATERIALS SCIENCE↗

Dynamic In‐Plane Heterogeneous and Inverted Response of Graphite to Fast Charging and Discharging Conditions in Lithium‐Ion Pouch Cells

Solutions for improving fast charging of lithium‐ion batteries have largely focused on alleviating through‐plane lithiation gradients while little is understood about in‐plane heterogeneities and how to resolve them. Herein, high‐speed synchrotron X‐ray diffraction (XRD) resolves graphite lithiation spatially and temporally during 6 C charging and 2 C discharging. At every point during operation, considerable differences in the state of lithiation across the pouch cell are present. Some regions are more responsive to operation than others, reaching full lithiation early during charge and full delithiation during discharge. Other regions within the cell never fully delithiate during discharge, despite a prolonged voltage hold at 2.8 V. Using time‐resolved XRD data, the calculated local current density (mA cm −2 ) at the graphite surface shows an unexpected occurrence of local inverted current densities where regions of graphite are observed to delithiate during charging and lithiate during discharging. A pseudo‐3D model is developed for the graphite electrode with spatially varying microstructural tortuosity to show how microstructural heterogeneity could influence spatial charge dynamics. The model could not predict the complex in‐plane charge behavior observed within the cell. Consequently physics‐based charging protocols based on homogeneous electrode assumptions may underestimate the local variations in charge dynamics and occurrence of lithium plating.

25 ENERGY STORAGE↗

Employment access assessed using the mobility energy productivity (MEP) metric

Transit agencies, local governments, employers, and job-seekers have a shared interest in connecting residents with jobs in an affordable and time efficient manner, with public agencies also caring about energy efficiency and air quality. Employment hubs are an opportunity to solve the spatial mismatch between homes of job-seekers and the locations of desirable jobs. Such is the case in Columbus, Ohio, between Rickenbacker Industrial Park and the Linden neighborhood, which has experienced persistent poverty. Using the mobility energy productivity (MEP) metric to examine travel time, cost, and energy efficiency, we show current transit service is undesirable due to excessive travel time (70 min, MEP = 0), while driving alone (MEP = 0.20) may be less desirable than a hypothetical, fare-free microtransit service (MEP = 0.23). Updating MEP to use locally-derived input data can help identify parameters under which providing microtransit service in a specific place has compelling benefits in terms of vehicle energy efficiency as well as cost and travel time for riders.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Cone-Beam CT-Based Delineation of Stereotactic Lung Targets: The Influence of Image Modality and Target Size on Interobserver Variability

Purpose: It is generally agreed that the safe implementation of stereotactic body radiotherapy requires image guidance. The aim of this work was to assess interobserver variability in the delineation of lung lesions on cone-beam CT (CBCT) images compared with CT-based contouring for adaptive stereotactic body radiotherapy. The influence of target size was also evaluated. Methods and Materials: Eight radiation oncologists delineated gross tumor volumes in 12 patient cases (non-small cell lung cancer I-II or solitary metastasis) on planning CTs and on CBCTs. Cases were divided into two groups with tumor diameters of less than (Group A) or more than 2 cm (Group B). Comparison of mean volumes delineated by all observers and range and coefficient of variation were reported for each case and image modality. Interobserver variability was assessed by means of standard error of measurement, conformity index (CI), and its generalized observer-independent approach. The variance between single observers on CT and CBCT images was measured via interobserver reliability coefficient. Results: Interobserver variability on CT images was 17% with 0.79 reliability, compared with 21% variability on CBCT and 0.76 reliability. On both image modalities, values of the intraobserver reliability coefficient (0.99 for CT and 0.97 for CBCT) indicated high reproducibility of results. In general, lower interobserver agreement was observed for small lesions (CI{sub genA} = 0.62 {+-} 0.06 vs. CI{sub genB} = 0.70 {+-} 0.03, p < 0.05). The analysis of single patient cases revealed that presence of spicules, diffuse infiltrations, proximity of the tumors to the vessels and thoracic wall, and respiration motion artifacts presented the main sources of the variability. Conclusion: Interobserver variability for Stage I-II non-small cell lung cancer and lung metastasis was slightly higher on CBCT compared with CT. Absence of significant differences in interobserver variability suggests that CBCT imaging provides an effective tool for tumor localization, and image data could be also used for target volume delineation purposes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Health-Related Quality of Life After Stereotactic Body Radiation Therapy for Localized Prostate Cancer: Results From a Multi-institutional Consortium of Prospective Trials

Purpose: To evaluate the early and late health-related quality of life (QOL) outcomes among prostate cancer patients following stereotactic body radiation therapy (SBRT). Methods and Materials: Patient self-reported QOL was prospectively measured among 864 patients from phase 2 clinical trials of SBRT for localized prostate cancer. Data from the Expanded Prostate Cancer Index Composite (EPIC) instrument were obtained at baseline and at regular intervals up to 6 years. SBRT delivered a median dose of 36.25 Gy in 4 or 5 fractions. A short course of androgen deprivation therapy was given to 14% of patients. Results: Median follow-up was 3 years and 194 patients remained evaluable at 5 years. A transient decline in the urinary and bowel domains was observed within the first 3 months after SBRT which returned to baseline status or better within 6 months and remained so beyond 5 years. The same pattern was observed among patients with good versus poor baseline function and was independent of the degree of early toxicities. Sexual QOL decline was predominantly observed within the first 9 months, a pattern not altered by the use of androgen deprivation therapy or patient age. Conclusion: Long-term outcome demonstrates that prostate SBRT is well tolerated and has little lasting impact on health-related QOL. A transient and modest decline in urinary and bowel QOL during the first few months after SBRT quickly recovers to baseline levels. With a large number of patients evaluable up to 5 years following SBRT, it is unlikely that unexpected late adverse effects will manifest themselves.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A high order Cartesian grid, finite volume method for elliptic interface problems

We present a higher-order finite volume method for solving elliptic PDEs with jump conditions on interfaces embedded in a 2D Cartesian grid. Second, fourth, and sixth order accuracy is demonstrated on a variety of tests including problems with high-contrast and spatially varying coefficients, large discontinuities in the source term, and complex interface geometries. We include a generalized truncation error analysis based on cell-centered Taylor series expansions, which then define stencils in terms of local discrete solution data and geometric information. In the process, we develop a simple method based on Green's theorem for computing exact geometric moments directly from an implicit function definition of the embedded interface. This approach produces stencils with a simple bilinear representation, where spatially-varying coefficients and jump conditions can be easily included and finite volume conservation can be enforced.

97 MATHEMATICS AND COMPUTING↗

Proteomic Profiling of Intra-Islet Features Reveals Substructure-Specific Protein Signatures

Despite their diminutive size, islets of Langerhans play a large role in maintaining systemic energy balance in the body. New technologies have enabled us to go from studying the whole pancreas, to isolated whole islets, to partial islet sections, and now to islet substructures isolated from within the islet. Using a microfluidic nanodroplet-based proteomics platform coupled with laser capture microdissection (LCM), we present an in-depth investigation of protein profiles specific to regions within the islet. These regions studied include the vascular tissue containing interface boundary, micro-vascular tissue internal to the islet, isolated endocrine cells, islet sections with vasculature intact, and finally acinar tissue from around the islet. Unique protein signatures observed in the inner vasculature potentially indicate increased innervation and intra-islet neuron-like crosstalk compared to external vasculature. We also demonstrate the utility of these data for isolating localized structure-specific drug-target interactions using existing protein/drug binding databases.

59 BASIC BIOLOGICAL SCIENCES↗

Systematic measurement of fast neutron background fluctuations in an urban area using a mobile detection system

Neutron background measurements using a mobile trailer-based system were conducted in Knoxville, Tennessee. The 0.5 m 2 system consisting of 8 EJ-301 liquid scintillation detectors was used to collect neutron background measurements in order to better understand the systematic background variations that depend solely on the street-level measurement position in a local, downtown area. Data was collected along 5 different streets in the downtown Knoxville area, and the measurements were found to be repeatable. Using 10-min measurements, fractional uncertainty in each measured data point was <2%. Compared with fast neutron background count rates measured away from downtown Knoxville, a reduction in background count rates ranging from 10-50% was observed in the downtown area, sometimes varying substantially over distances of tens of meters. These reductions are attributed to the shielding of adjacent buildings, quantified in part here by the metric angle-of-open-sky. The adjacent buildings may serve to shield cosmic ray neutron flux.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance of asynchronous optimized Schwarz with one-sided communication

In asynchronous iterative methods on distributed-memory computers, processes update their local solutions using data from other processes without an implicit or explicit global synchronization that corresponds to advancing the global iteration counter. Here in this work, we test the asynchronous optimized Schwarz domain-decomposition iterative method using various one-sided (remote direct memory access) communication schemes with passive target completion. The results show that when one-sided communication is well-supported, the asynchronous version of optimized Schwarz can outperform the synchronous version even for perfectly balanced partitionings of the problem on a supercomputer with uniform nodes.

97 MATHEMATICS AND COMPUTING↗