Search NASA⌕ Search

SEARCH · Search NASA

Results for “depth”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,099 records · Page 61

Development of a novel depth of interaction PET detector using highly multiplexed G-APD cross-strip encoding

Purpose: The aim of this study was to develop a prototype PET detector module for a combined small animal positron emission tomography and magnetic resonance imaging (PET/MRI) system. The most important factor for small animal imaging applications is the detection sensitivity of the PET camera, which can be optimized by utilizing longer scintillation crystals. At the same time, small animal PET systems must yield a high spatial resolution. The measured object is very close to the PET detector because the bore diameter of a high field animal MR scanner is limited. When used in combination with long scintillation crystals, these small-bore PET systems generate parallax errors that ultimately lead to a decreased spatial resolution. Thus, we developed a depth of interaction (DoI) encoding PET detector module that has a uniform spatial resolution across the whole field of view (FOV), high detection sensitivity, compactness, and insensitivity to magnetic fields. Methods: The approach was based on Geiger mode avalanche photodiode (G-APD) detectors with cross-strip encoding. The number of readout channels was reduced by a factor of 36 for the chosen block elements. Two 12 × 2 G-APD strip arrays (25μm cells) were placed perpendicular on each face of a 12 × 12 lutetium oxyorthosilicate crystal block with a crystal size of 1.55 × 1.55 × 20 mm. The strip arrays were multiplexed into two channels and used to calculate the x, y coordinates for each array and the deposited energy. The DoI was measured in step sizes of 1.8 mm by a collimated {sup 18}F source. The coincident resolved time (CRT) was analyzed at all DoI positions by acquiring the waveform for each event and applying a digital leading edge discriminator. Results: All 144 crystals were well resolved in the crystal flood map. The average full width half maximum (FWHM) energy resolution of the detector was 12.8% ± 1.5% with a FWHM CRT of 1.14 ± 0.02 ns. The average FWHM DoI resolution over 12 crystals was 2.90 ± 0.15 mm. Conclusions: The novel DoI PET detector, which is based on strip G-APD arrays, yielded a DoI resolution of 2.9 mm and excellent timing and energy resolution. Its high multiplexing factor reduces the number of electronic channels. Thus, this cross-strip approach enables low-cost, high-performance PET detectors for dedicated small animal PET and PET/MRI and potentially clinical PET/MRI systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined time-of-flight and depth-of-interaction detector for total-body positron emission tomography

Purpose: In support of a project to build a total-body PET scanner with an axial field-of-view of 2 m, the authors are developing simple, cost-effective block detectors with combined time-of-flight (TOF) and depth-of-interaction (DOI) capabilities. Methods: This work focuses on investigating the potential of phosphor-coated crystals with conventional PMT-based block detector readout to provide DOI information while preserving timing resolution. The authors explored a variety of phosphor-coating configurations with single crystals and crystal arrays. Several pulse shape discrimination techniques were investigated, including decay time, delayed charge integration (DCI), and average signal shapes. Results: Pulse shape discrimination based on DCI provided the lowest DOI positioning error: 2 mm DOI positioning error was obtained with single phosphor-coated crystals while 3–3.5 mm DOI error was measured with the block detector module. Minimal timing resolution degradation was observed with single phosphor-coated crystals compared to uncoated crystals, and a timing resolution of 442 ps was obtained with phosphor-coated crystals in the block detector compared to 404 ps without phosphor coating. Flood maps showed a slight degradation in crystal resolvability with phosphor-coated crystals; however, all crystals could be resolved. Energy resolution was degraded by 3%–7% with phosphor-coated crystals compared to uncoated crystals. Conclusions: These results demonstrate the feasibility of obtaining TOF–DOI capabilities with simple block detector readout using phosphor-coated crystals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Choroidal vasculature characteristics based choroid segmentation for enhanced depth imaging optical coherence tomography images

Purpose: In clinical research, it is important to measure choroidal thickness when eyes are affected by various diseases. The main purpose is to automatically segment choroid for enhanced depth imaging optical coherence tomography (EDI-OCT) images with five B-scans averaging. Methods: The authors present an automated choroid segmentation method based on choroidal vasculature characteristics for EDI-OCT images with five B-scans averaging. By considering the large vascular of the Haller’s layer neighbor with the choroid-sclera junction (CSJ), the authors measured the intensity ascending distance and a maximum intensity image in the axial direction from a smoothed and normalized EDI-OCT image. Then, based on generated choroidal vessel image, the authors constructed the CSJ cost and constrain the CSJ search neighborhood. Finally, graph search with smooth constraints was utilized to obtain the CSJ boundary. Results: Experimental results with 49 images from 10 eyes in 8 normal persons and 270 images from 57 eyes in 44 patients with several stages of diabetic retinopathy and age-related macular degeneration demonstrate that the proposed method can accurately segment the choroid of EDI-OCT images with five B-scans averaging. The mean choroid thickness difference and overlap ratio between the authors’ proposed method and manual segmentation drawn by experts were −11.43 μm and 86.29%, respectively. Conclusions: Good performance was achieved for normal and pathologic eyes, which proves that the authors’ method is effective for the automated choroid segmentation of the EDI-OCT images with five B-scans averaging.

60 APPLIED LIFE SCIENCES↗

SU-F-J-140: Using Handheld Stereo Depth Cameras to Extend Medical Imaging for Radiation Therapy Planning

Purpose: A correct body contour is essential for the accuracy of dose calculation in radiation therapy. While modern medical imaging technologies provide highly accurate representations of body contours, there are times when a patient’s anatomy cannot be fully captured or there is a lack of easy access to CT/MRI scanning. Recently, handheld cameras have emerged that are capable of performing three dimensional (3D) scans of patient surface anatomy. By combining 3D camera and medical imaging data, the patient’s surface contour can be fully captured. Methods: A proof-of-concept system matches a patient surface model, created using a handheld stereo depth camera (DC), to the available areas of a body contour segmented from a CT scan. The matched surface contour is then converted to a DICOM structure and added to the CT dataset to provide additional contour information. In order to evaluate the system, a 3D model of a patient was created by segmenting the body contour with a treatment planning system (TPS) and fabricated with a 3D printer. A DC and associated software were used to create a 3D scan of the printed phantom. The surface created by the camera was then registered to a CT model that had been cropped to simulate missing scan data. The aligned surface was then imported into the TPS and compared with the originally segmented contour. Results: The RMS error for the alignment between the camera and cropped CT models was 2.26 mm. Mean distance between the aligned camera surface and ground truth model was −1.23 +/−2.47 mm. Maximum deviations were < 1 cm and occurred in areas of high concavity or where anatomy was close to the couch. Conclusion: The proof-of-concept study shows an accurate, easy and affordable method to extend medical imaging for radiation therapy planning using 3D cameras without additional radiation. Intel provided the camera hardware used in this study.

60 APPLIED LIFE SCIENCES↗

Climbing the crustal ladder: Magma storage-depth evolution during a volcanic flare-up

Very large eruptions (>50 km 3 ) and supereruptions (>450 km 3 ) reveal Earth’s capacity to produce and store enormous quantities (>1000 km 3 ) of crystal-poor, eruptible magma in the shallow crust. We explore the interplay between crustal evolution and volcanism during a volcanic flare-up in the Taupo Volcanic Zone (TVZ, New Zealand) using a combination of quartz-feldspar-melt equilibration pressures and time scales of quartz crystallization. Over the course of the flare-up, crystallization depths became progressively shallower, showing the gradual conditioning of the crust. Yet, quartz crystallization times were invariably very short (<100 years), demonstrating that very large reservoirs of eruptible magma were transient crustal features. We conclude that the dynamic nature of the TVZ crust favored magma eruption over storage. Episodic tapping of eruptible magmas likely prevented a supereruption. Instead, multiple very large bodies of eruptible magma were assembled and erupted in decadal time scales.

58 GEOSCIENCES↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Draft Genome Sequence of Pseudoalteromonas sp. Strain ND6B, an Oil-Degrading Isolate from Eastern Mediterranean Sea Water Collected at a Depth of 1,210 Meters

We report the draft genome of Pseudoalteromonas sp. strain ND6B, which is able to grow with crude oil as a carbon source. Strain ND6B was isolated from eastern Mediterranean Sea deep water at a depth of 1,210 m. The genome of strain ND6B provides insight into the oil-degrading ability of the Pseudoalteromonas species.

02 PETROLEUM↗

Draft Genome Sequence of Thalassotalea sp. Strain ND16A Isolated from Eastern Mediterranean Sea Water Collected from a Depth of 1,055 Meters

Thalassotalea sp. strain ND16A belongs to the family Colwelliaceae and was isolated from eastern Mediterranean Sea water at a depth of 1,055 m. Members of Colwelliaceae are ubiquitous marine heterotrophs. Lastly, here we report the draft genome sequence of Thalassotalea sp. strain ND16A, a member of the newly described genus Thalassotalea.

59 BASIC BIOLOGICAL SCIENCES↗

New regions of diffraction reflection in apodized one-dimensional photonic crystals with a large modulation depth

Particular features of the band structure of one-dimensional apodized photonic crystals based on metamaterials are studied in the case in which the medium is simultaneously inhomogeneous with respect to both the dielectric and the magnetic properties. It is shown that in the case of oblique incidence of light at large values of the modulation depth, a new region of diffraction reflection appears. This new region of diffraction reflection is also observed at magnetic permeability μ = const = 1. The particular features of the absorption and localization of light in these structures are examined.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation of singularities on the charged surface of a liquid-helium layer with a finite depth

The dynamics of the development of an instability of a charged surface of a liquid-helium layer with a finite depth is investigated. The equations describing the evolution of the free surface are derived with the use of conformal variables for the case in which the charge completely screens the electric field above the liquid. A model of the evolution of a spatially localized perturbation of a liquid-helium surface is proposed for the strong-field limit where the dynamics of the liquid is predominantly determined by the effect of electrostatic forces. This model describes the development of an instability of the initially planar boundary to the point of the formation of cuspidal dimples. The limit of an infinitely deep liquid is considered. The stability of the previously revealed liquid flow regime described by the Laplacian growth equations is proved without significant constraints on the surface geometry.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determination of the cascade-curve maximum depth from the muon component on the Yakutsk EAS array

The lateral distribution of muons with a threshold E{sub µ} secθ GeV in extensive air showers with E{sub 0} ≥ 10{sup 17} eV over the period of observations on the Yakutsk array from November 2011 to June 2013 has been investigated. It follows from this distribution that the cascade-curve maximum depth X{sub m} in the energy range (1–5) × 10{sup 17} eV increases relatively rapidly, because the cosmic-ray composition changes from iron nuclei dominating at E{sub 0} ≈ 10{sup 17} eV to protons.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Depth of the maximum of extensive air showers and mass composition of primary cosmic radiation at an energy of 4 x 10{sup 17} eV according to data on radioemission from extensive air showers

The results of a reanalysis of experimental data on extensive-air-shower radioemission that were obtained previously at the Moscow State University array for studying extensive air showers are presented. The lateral distribution of radioemission is given for showers characterized by a primary energy of 4 x 10{sup 17} eV and a zenith angle of {theta} = 35 deg. On the basis of an analysis of a lateral distribution of radioemission, the average value of the shower-maximum depth at a primary energy of 4 x 10{sup 17} eV is estimated at X{sub max} = 655 {+-} 13 g/cm{sup 2}. Estimates of themass content of primary radiation that were obtained from an analysis of the distribution of X{sub max} are compatible with the hypothesis that the role of light nuclei becomes more pronounced at energies above 10{sup 17} eV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Electrical and optical properties of near-surface AlGaAs/InGaAs/AlGaAs quantum wells with different quantum-well depths

A series of AlGaAs/InGaAs/AlGaAs quantum-well heterostructures with different quantum-well depths and approximately the same concentrations of two-dimensional electrons is grown by molecular-beam epitaxy. The built-in electric field in the grown samples is determined from the photoreflectance data and, on this basis, the energy-band structure in the quantum-well region is calculated. It is found that the highest mobility {mu}{sub e} of two-dimensional electrons is attained in the sample with a barrier-layer thickness of L{sub b} = 11 nm. Measurements of the photoluminescence spectra and the band-structure calculations demonstrate that, as the quantum well becomes closer to the surface, the doping profile broadens due to diffusion and segregation processes. The nonmonotonic dependence of {mu}{sub e} on the distance between the surface and the quantum well is explained.

36 MATERIALS SCIENCE↗

Dependence of the electron capture velocity on the quantum-well depth in semiconductor lasers

Three laser structures with a single strained InGaAs quantum well of different depths and a GaAs or Al{sub 0.1}Ga{sub 0.9}As waveguide region are grown by metal-organic chemical vapor deposition. Using the experimentally determined values of the threshold current density and internal differential quantum efficiency, the velocity of electron capture into the quantum well is calculated for each of these structures. It is found that the capture velocity into deep quantum wells is significantly lower than into shallow ones.

36 MATERIALS SCIENCE↗

Escape Depth of Secondary and Photoelectrons from CdTe Films with a Ba Film

Escape zone depths λ' for true-secondary electrons and photoelectrons from pure CdTe and CdTe with a Ba film of thickness θ ≤ 1 monolayer have been estimated for the first time. It is shown that upon a decrease of the work function of the surface by 2 eV, the value of λ' increases by 1.2–1.3 times.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the Muon Production Depths at the Pierre Auger Observatory

The muon content of extensive air showers is an observable sensitive to the primary composition and to the hadronic interaction properties. The Pierre Auger Observatory uses water-Cherenkov detectors to measure particle densities at the ground and therefore is sensitive to the muon content of air showers. We present here a method which allows us to estimate the muon production depths by exploiting the measurement of the muon arrival times at the ground recorded with the Surface Detector of the Pierre Auger Observatory. The analysis is performed in a large range of zenith angles, thanks to the capability of estimating and subtracting the electromagnetic component, and for energies between $10^{19.2}$ and $10^{20}$ eV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of Triethanolamine as an Additive for Rechargeable Alkaline Zn/MnO 2 Batteries under Limited Depth of Discharge Conditions

Rechargeable alkaline Zn/MnO 2 batteries are being developed for use as cost-effective grid-scale energy storage devices. Previous studies have shown that limiting the depth of discharge (DOD) of the MnO 2 cathode extends cell lifetime while still providing a cost-effective battery system. Herein, a comprehensive study of triethanolamine (TEA) as an additive in Zn/MnO 2 limited DOD batteries is provided by examining the effect of TEA in full cells as well as independently on the cathode, anode, separator, and electrolyte. Improvement in cycle-ability of the cathode (on average, 80% of cycled capacity remains after 191 cycles without TEA, 568 cycles with TEA) and a decrease in ionic zinc mobility across Celgard 3501 (7.91 × 10 -5 cm 2 /min without TEA, 3.56 × 10 -5 cm 2 /min with TEA) and Cellophane 350P00 (3.26 × 10 -5 cm 2 /min without TEA, 4.74 × 10 -6 cm 2 /min with TEA) separators upon the addition of TEA are demonstrated. However, TEA increased both the reduction potential of Zn (-0.68 V vs. Hg/HgO without TEA, -0.76 V with TEA) and the solubility of Zn 2+ (0.813 M without TEA, 1.023 M with TEA). Overall, the addition of TEA extended the lifetime of limited DOD cells on average by 297%.

25 ENERGY STORAGE↗

Detailed Aerosol Optical Depth Intercomparison between Brewer and Li-Cor 1800 Spectroradiometers and a Cimel Sun Photometer

We present here representative results about a comparison of aerosol optical depth (AOD) using different instruments during three short and intensive campaigns carried out from 1999 to 2001 at El Arenosillo (Huelva, Spain). The specific aim of this study is to determine the level of agreement between three different instruments operating at our station. This activity, however, is part of a broader objective to recover an extended data series of AOD in the UV range obtained from a Brewer spectroradiometer. This instrument may be used to obtain AOD at the same five UV wavelengths used during normal operation for ozone content determination. As part of the validation of the Brewer AOD data recovery process, a Cimel sun photometer and another spectroradiometer, a Licor1800, were used. The Licor1800 spectroradiometer (which covers the spectral range 300-1100 nm) was the first instrument used at this station for aerosol monitoring (1996-99) and it was operated during these intercomparison campaigns (1999-2001) specifically to assess the continuity of the AOD data series. The Cimel sunphotometer was installed at our station at the beginning of 2000 as part of AERONET to provide AOD data over the visible and near infrared spectrum. A detailed comparison of these three instruments is carried out by means of near-simultaneous measurements, with particular emphasis on examining any diurnal AOD variability that may be linked with calibration and/or measurement errors or real atmospheric variability. Because the comparison is carried out from UV (320nm) to near infrared (1020nm) wavelengths under all possible atmospheric conditions (including clouds), AOD values range from near zero up to 1. Absolute AOD uncertainties range from 0.02 for the Cimel to 0.08 for the Brewer, with intermediate values for the Licor1800. All the values during the comparison are in reasonable agreement, when taking into account the different performance characteristics of each instrument. The comparison also demonstrates current deficiencies in the Brewer data and thus the difficulty to determine AOD values with low errors.

54 ENVIRONMENTAL SCIENCES↗